Aaron J. Young
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Aaron J. Young has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Levi J. Hargrove
Center for Bionic Medicine, Shirley Ryan AbilityLab, Chicago, IL, USA
4 shared publications - Elliott J. Rouse
Robotics Department, University of Michigan, Ann Arbor, USA
2 shared publications - Lauren H. Smith
Department of Biomedical Engineering, Northwestern University, Chicago, IL, USA
2 shared publications Levi J. Hargrove
The Rehabilitation Institute of Chicago
2 shared publications- Todd Kuiken
Genetic Engineering and Society Center, North Carolina State University, Raleigh, USA
2 shared publications A.M. Simon
1 shared publication
Latest Publications
- 1 May 2016
- Published by Elsevier in Journal of Vascular Surgery
- Vol. 63 (5) , 1405-1406
Intuitive Control of a Powered Prosthetic Leg During Ambulation: A Randomized Clinical Trial
- 1 May 2016
- Published by Elsevier in Journal of Vascular Surgery
- Vol. 63 (5) , 1405-1406
Intuitive Control of a Powered Prosthetic Leg During Ambulation: A Randomized Clinical Trial
- Open Access
- 1 January 2014
- Published by Springer Nature in Journal of NeuroEngineering and Rehabilitation
- Vol. 11 (1) , 5
A comparison of the real-time controllability of pattern recognition to conventional myoelectric control for discrete and simultaneous movements
Myoelectric control has been used for decades to control powered upper limb prostheses. Conventional, amplitude-based control has been employed to control a single prosthesis degree of freedom (DOF) such as closing and opening of the hand. Within the last decade, new and advanced arm and hand prostheses have been constructed that are capable of actuating numerous DOFs. Pattern recognition control has been proposed to control a greater number of DOFs than conventional control, but has traditionally been limited to sequentially controlling DOFs one at a time. However, able-bodied individuals use multiple DOFs simultaneously, and it may be beneficial to provide amputees the ability to perform simultaneous movements. In this study, four amputees who had undergone targeted motor reinnervation (TMR) surgery with previous training using myoelectric prostheses were configured to use three control strategies: 1) conventional amplitude-based myoelectric control, 2) sequential (one-DOF) pattern recognition control, 3) simultaneous pattern recognition control. Simultaneous pattern recognition was enabled by having amputees train each simultaneous movement as a separate motion class. For tasks that required control over just one DOF, sequential pattern recognition based control performed the best with the lowest average completion times, completion rates and length error. For tasks that required control over 2 DOFs, the simultaneous pattern recognition controller performed the best with the lowest average completion times, completion rates and length error compared to the other control strategies. In the two strategies in which users could employ simultaneous movements (conventional and simultaneous pattern recognition), amputees chose to use simultaneous movements 78% of the time with simultaneous pattern recognition and 64% of the time with conventional control for tasks that required two DOF motions to reach the target. These results suggest that when amputees are given the ability to control multiple DOFs simultaneously, they choose to perform tasks that utilize multiple DOFs with simultaneous movements. Additionally, they were able to perform these tasks with higher performance (faster speed, lower length error and higher completion rates) without losing substantial performance in 1 DOF tasks.
- 1 January 2014
- Published by Springer Nature in Journal of NeuroEngineering and Rehabilitation
- Vol. 11 (1) , 5
Open AccessA comparison of the real-time controllability of pattern recognition to conventional myoelectric control for discrete and simultaneous movements
Myoelectric control has been used for decades to control powered upper limb prostheses. Conventional, amplitude-based control has been employed to control a single prosthesis degree of freedom (DOF) such as closing and opening of the hand. Within the last decade, new and advanced arm and hand prostheses have been constructed that are capable of actuating numerous DOFs. Pattern recognition control has been proposed to control a greater number of DOFs than conventional control, but has traditionally been limited to sequentially controlling DOFs one at a time. However, able-bodied individuals use multiple DOFs simultaneously, and it may be beneficial to provide amputees the ability to perform simultaneous movements. In this study, four amputees who had undergone targeted motor reinnervation (TMR) surgery with previous training using myoelectric prostheses were configured to use three control strategies: 1) conventional amplitude-based myoelectric control, 2) sequential (one-DOF) pattern recognition control, 3) simultaneous pattern recognition control. Simultaneous pattern recognition was enabled by having amputees train each simultaneous movement as a separate motion class. For tasks that required control over just one DOF, sequential pattern recognition based control performed the best with the lowest average completion times, completion rates and length error. For tasks that required control over 2 DOFs, the simultaneous pattern recognition controller performed the best with the lowest average completion times, completion rates and length error compared to the other control strategies. In the two strategies in which users could employ simultaneous movements (conventional and simultaneous pattern recognition), amputees chose to use simultaneous movements 78% of the time with simultaneous pattern recognition and 64% of the time with conventional control for tasks that required two DOF motions to reach the target. These results suggest that when amputees are given the ability to control multiple DOFs simultaneously, they choose to perform tasks that utilize multiple DOFs with simultaneous movements. Additionally, they were able to perform these tasks with higher performance (faster speed, lower length error and higher completion rates) without losing substantial performance in 1 DOF tasks.
- 20 September 2013
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 42 (3) , 631-641
Intent Recognition in a Powered Lower Limb Prosthesis Using Time History Information
New computerized and powered lower limb prostheses are being developed that enable amputees to perform multiple locomotion modes. However, current lower limb prosthesis controllers are not capable of transitioning these devices automatically and seamlessly between locomotion modes such as level-ground walking, stairs and slopes. The focus of this study was to evaluate different intent recognition interfaces, which if configured properly, may be capable of providing more natural transitions between locomotion modes. Intent recognition can be accomplished using a multitude of different signals from mechanical sensors on the prosthesis. Since these signals are non-stationary over any given stride, and gait is cyclical, time history information may improve locomotion mode recognition. The authors propose a dynamic Bayesian network classification strategy to incorporate prior sensor information over the gait cycle with current sensor information. Six transfemoral amputees performed locomotion circuits comprising level-ground walking and ascending/descending stairs and ramps using a powered knee and ankle prosthesis. Using time history reduced steady-state misclassifications by over half (p < 0.01), when compared to strategies that did not use time history, without reducing intent recognition performance during transitions. These results suggest that including time history information across the gait cycle can enhance locomotion mode intent recognition performance.
- 20 September 2013
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 42 (3) , 631-641
Intent Recognition in a Powered Lower Limb Prosthesis Using Time History Information
New computerized and powered lower limb prostheses are being developed that enable amputees to perform multiple locomotion modes. However, current lower limb prosthesis controllers are not capable of transitioning these devices automatically and seamlessly between locomotion modes such as level-ground walking, stairs and slopes. The focus of this study was to evaluate different intent recognition interfaces, which if configured properly, may be capable of providing more natural transitions between locomotion modes. Intent recognition can be accomplished using a multitude of different signals from mechanical sensors on the prosthesis. Since these signals are non-stationary over any given stride, and gait is cyclical, time history information may improve locomotion mode recognition. The authors propose a dynamic Bayesian network classification strategy to incorporate prior sensor information over the gait cycle with current sensor information. Six transfemoral amputees performed locomotion circuits comprising level-ground walking and ascending/descending stairs and ramps using a powered knee and ankle prosthesis. Using time history reduced steady-state misclassifications by over half (p < 0.01), when compared to strategies that did not use time history, without reducing intent recognition performance during transitions. These results suggest that including time history information across the gait cycle can enhance locomotion mode intent recognition performance.
- 10 December 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 60 (5) , 1250-1258
Classification of Simultaneous Movements Using Surface EMG Pattern Recognition
Advanced upper limb prostheses capable of actuating multiple degrees of freedom (DOFs) are now commercially available. Pattern recognition algorithms that use surface electromyography (EMG) signals show great promise as multi-DOF controllers. Unfortunately, current pattern recognition systems are limited to activate only one DOF at a time. This study introduces a novel classifier based on Bayesian theory to provide classification of simultaneous movements. This approach and two other classification strategies for simultaneous movements were evaluated using nonamputee and amputee subjects classifying up to three DOFs, where any two DOFs could be classified simultaneously. Similar results were found for nonamputee and amputee subjects. The new approach, based on a set of conditional parallel classifiers was the most promising with errors significantly less ( p <; 0.05) than a single linear discriminant analysis (LDA) classifier or a parallel approach. For three-DOF classification, the conditional parallel approach had error rates of 6.6% on discrete and 10.9% on combined motions, while the single LDA had error rates of 9.4% on discrete and 14.1% on combined motions. The low error rates demonstrated suggest than pattern recognition techniques on surface EMG can be extended to identify simultaneous movements, which could provide more life-like motions for amputees compared to exclusively classifying sequential movements.
- 10 December 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 60 (5) , 1250-1258
Classification of Simultaneous Movements Using Surface EMG Pattern Recognition
Advanced upper limb prostheses capable of actuating multiple degrees of freedom (DOFs) are now commercially available. Pattern recognition algorithms that use surface electromyography (EMG) signals show great promise as multi-DOF controllers. Unfortunately, current pattern recognition systems are limited to activate only one DOF at a time. This study introduces a novel classifier based on Bayesian theory to provide classification of simultaneous movements. This approach and two other classification strategies for simultaneous movements were evaluated using nonamputee and amputee subjects classifying up to three DOFs, where any two DOFs could be classified simultaneously. Similar results were found for nonamputee and amputee subjects. The new approach, based on a set of conditional parallel classifiers was the most promising with errors significantly less ( p <; 0.05) than a single linear discriminant analysis (LDA) classifier or a parallel approach. For three-DOF classification, the conditional parallel approach had error rates of 6.6% on discrete and 10.9% on combined motions, while the single LDA had error rates of 9.4% on discrete and 14.1% on combined motions. The low error rates demonstrated suggest than pattern recognition techniques on surface EMG can be extended to identify simultaneous movements, which could provide more life-like motions for amputees compared to exclusively classifying sequential movements.
- 29 November 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 59 (3) , 645-652
Improving Myoelectric Pattern Recognition Robustness to Electrode Shift by Changing Interelectrode Distance and Electrode Configuration
Pattern recognition of myoelectric signals for prosthesis control has been extensively studied in research settings and is close to clinical implementation. These systems are capable of intuitively controlling the next generation of dexterous prosthetic hands. However, pattern recognition systems perform poorly in the presence of electrode shift, defined as movement of surface electrodes with respect to the underlying muscles. This paper focused on investigating the optimal interelectrode distance, channel configuration, and electromyography feature sets for myoelectric pattern recognition in the presence of electrode shift. Increasing interelectrode distance from 2 to 4 cm improved pattern recognition system performance in terms of classification error and controllability ( p <; 0.01). Additionally, for a constant number of channels, an electrode configuration that included electrodes oriented both longitudinally and perpendicularly with respect to muscle fibers improved robustness in the presence of electrode shift ( p <; 0.05). We investigated the effect of the number of recording channels with and without electrode shift and found that four to six channels were sufficient for pattern recognition control. Finally, we investigated different feature sets for pattern recognition control using a linear discriminant analysis classifier and found that an autoregressive set significantly ( p <; 0.01) reduced sensitivity to electrode shift compared to a traditional time-domain feature set.
- 29 November 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 59 (3) , 645-652
Improving Myoelectric Pattern Recognition Robustness to Electrode Shift by Changing Interelectrode Distance and Electrode Configuration
Pattern recognition of myoelectric signals for prosthesis control has been extensively studied in research settings and is close to clinical implementation. These systems are capable of intuitively controlling the next generation of dexterous prosthetic hands. However, pattern recognition systems perform poorly in the presence of electrode shift, defined as movement of surface electrodes with respect to the underlying muscles. This paper focused on investigating the optimal interelectrode distance, channel configuration, and electromyography feature sets for myoelectric pattern recognition in the presence of electrode shift. Increasing interelectrode distance from 2 to 4 cm improved pattern recognition system performance in terms of classification error and controllability ( p <; 0.01). Additionally, for a constant number of channels, an electrode configuration that included electrodes oriented both longitudinally and perpendicularly with respect to muscle fibers improved robustness in the presence of electrode shift ( p <; 0.05). We investigated the effect of the number of recording channels with and without electrode shift and found that four to six channels were sufficient for pattern recognition control. Finally, we investigated different feature sets for pattern recognition control using a linear discriminant analysis classifier and found that an autoregressive set significantly ( p <; 0.01) reduced sensitivity to electrode shift compared to a traditional time-domain feature set.
- 1 August 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2011 (1094687X) , 3873-3879
Effects of interelectrode distance on the robustness of myoelectric pattern recognition systems
Myoelectric pattern recognition control can potentially provide upper limb amputees with intuitive control of multiple prosthetic functions. However, the lack of robustness of myoelectric pattern recognition algorithms is a barrier for clinical implementation. One issue that can contribute to poor system performance is electrode shift, which is a change in the location of the electrodes with respect to the underlying muscles that occurs during donning and doffing and daily use. We investigated the effects of interelectrode distance and feature choice on system performance in the presence of electrode shift. Increasing the interelectrode distance from 2 cm to 4 cm significantly (p<;0.01) improved classification accuracy in the presence of electrode shifts of up to 2 cm. In a controllability test, increasing the interelectrode distance from 2 cm to 4 cm improved the user's ability to control a virtual prosthesis in the presence of electrode shift. Use of an autoregressive feature set significantly (p<;0.01) reduced sensitivity to electrode shift when compared to use of a traditional time-domain feature set.
- 1 August 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2011 (1094687X) , 3873-3879
Effects of interelectrode distance on the robustness of myoelectric pattern recognition systems
Myoelectric pattern recognition control can potentially provide upper limb amputees with intuitive control of multiple prosthetic functions. However, the lack of robustness of myoelectric pattern recognition algorithms is a barrier for clinical implementation. One issue that can contribute to poor system performance is electrode shift, which is a change in the location of the electrodes with respect to the underlying muscles that occurs during donning and doffing and daily use. We investigated the effects of interelectrode distance and feature choice on system performance in the presence of electrode shift. Increasing the interelectrode distance from 2 cm to 4 cm significantly (p<;0.01) improved classification accuracy in the presence of electrode shifts of up to 2 cm. In a controllability test, increasing the interelectrode distance from 2 cm to 4 cm improved the user's ability to control a virtual prosthesis in the presence of electrode shift. Use of an autoregressive feature set significantly (p<;0.01) reduced sensitivity to electrode shift when compared to use of a traditional time-domain feature set.
- 9 June 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 58 (9) , 2537-2544
The Effects of Electrode Size and Orientation on the Sensitivity of Myoelectric Pattern Recognition Systems to Electrode Shift
Myoelectric pattern recognition systems for prosthesis control are often studied in controlled laboratory settings, but obstacles remain to be addressed before they are clinically viable. One important obstacle is the difficulty of maintaining system usability with socket misalignment. Misalignment inevitably occurs during prosthesis donning and doffing, producing a shift in electrode contact locations. We investigated how the size of the electrode detection surface and the placement of electrode poles (electrode orientation) affected system robustness with electrode shift. Electrodes oriented parallel to muscle fibers outperformed electrodes oriented perpendicular to muscle fibers in both shift and no-shift conditions (p <; 0.01). Another finding was the significant difference (p <; 0.01) in performance for the direction of electrode shift. Shifts perpendicular to the muscle fibers reduced classification accuracy and real-time controllability much more than shifts parallel to the muscle fibers. Increasing the size of the electrode detection surface was found to help reduce classification accuracy sensitivity to electrode shifts in a direction perpendicular to the muscle fibers but did not improve the real-time controllability of the pattern recognition system. One clinically important result was that a combination of longitudinal and transverse electrodes yielded high controllability with and without electrode shift using only four physical electrode pole locations.
- 9 June 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 58 (9) , 2537-2544
The Effects of Electrode Size and Orientation on the Sensitivity of Myoelectric Pattern Recognition Systems to Electrode Shift
Myoelectric pattern recognition systems for prosthesis control are often studied in controlled laboratory settings, but obstacles remain to be addressed before they are clinically viable. One important obstacle is the difficulty of maintaining system usability with socket misalignment. Misalignment inevitably occurs during prosthesis donning and doffing, producing a shift in electrode contact locations. We investigated how the size of the electrode detection surface and the placement of electrode poles (electrode orientation) affected system robustness with electrode shift. Electrodes oriented parallel to muscle fibers outperformed electrodes oriented perpendicular to muscle fibers in both shift and no-shift conditions (p <; 0.01). Another finding was the significant difference (p <; 0.01) in performance for the direction of electrode shift. Shifts perpendicular to the muscle fibers reduced classification accuracy and real-time controllability much more than shifts parallel to the muscle fibers. Increasing the size of the electrode detection surface was found to help reduce classification accuracy sensitivity to electrode shifts in a direction perpendicular to the muscle fibers but did not improve the real-time controllability of the pattern recognition system. One clinically important result was that a combination of longitudinal and transverse electrodes yielded high controllability with and without electrode shift using only four physical electrode pole locations.