LWLunan Wang

Lunan Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Lunan Wang has a total of 29 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Improvements in CYP2C9 Genotyping Accuracy Are Needed

    by Guigao Lin, Lang Yi, Kuo Zhang, Yu Sun, Lunan Wang, Rui Zhang, Jiehong Xie, Jinming Li

    Warfarin is the most commonly used oral anticoagulant in clinical practice. The cytochrome P450 2C9 (CYP2C9) and vitamin K epoxide reductase complex 1 (VKORC1) genotypes have been confirmed to be associated with warfarin dose requirements. Accurate genotyping results are of particular importance for the obtaining of reliable genotype-guided warfarin dosing information. This study aims to determine analytic performance of laboratories offering CYP2C9 and VKORC1 testing in China. A proficiency panel of 15 validated cell samples covering common CYP2C9 and VKORC1 genetic polymorphisms was provided to 31 participating laboratories and their genotyping results were evaluated. Fourteen data sets (45.2%) performed well with the entire panel of samples, and 17 data sets (54.8%) reported at least one genotyping error. For VKORC1 (-1639G>A), participating laboratories were 100% successful in detecting genotypes of GG, GA and AA. For CYP2C9, participants were greater than 90% successful in detecting genotypes of *1/*1, *1/*2, *1/*3, *2/*3, and *3/*3. However, 15 laboratories failed to detect rarely encountered variant genotype *2/*2. The poor performance of CYP2C9 genotyping may be due to the limitation of methodologies used for detecting CYP2C9*2 allele. The proficiency testing (PT) survey highlighted the need for improving genotyping accuracy for some laboratories in this field.


  • Open Access

    Identification of EBV infection in adults with egg specific food allergy

    by Yang Pan, Zhiyang Nie, Yuan Zhang, Kuo Zhang, Jinming Li, Lunan Wang

    Background: Food allergy has been reported increasingly around the world during the past several decades. Epstein-Barr virus (EBV), a common herpesvirus with high infection rate, is now suspected to be a risk or protective factor in food allergy. The aim of the study was to investigate the possible role of EBV infection in IgE-mediated food allergy. Methods: 34 patients with an egg allergy and 34 healthy controls participated in this study. Egg allergy was confirmed by open-food challenge. Serum anti-viral capsid antigen (VCA), anti-Epstein-Barr nuclear antigen 1 (EBNA-1) IgG and egg specific (yolk and white)-IgE levels were evaluated by enzyme linked immunosorbent assay (ELISA). At the same time, EBV DNA as well as viral miRNAs in these samples was quantified by real-time PCR. Results: The results showed that serum anti EBNA-1 IgG and two viral miRNAs (miR-BART1-5p and miR-BART7) were highly expressed in patients with egg allergy compared with healthy controls (p < 0.05, < 0.001 and < 0.01, respectively). Moreover, the expressions of anti EBNA-1 specific IgG, miR-BART1-5p and miR-BART7 positively correlated with the level of egg-specific IgE (p < 0.05, < 0.01 and < 0.01, respectively). The differences in anti VCA IgG concentration and EBV DNA copy number between the allergy patients and control individuals were not statistically significant. Conclusions: The high expression of EBV-specific antibody and miRNAs indicated that EBV infection might play a promoting role in IgE-mediated egg food allergy, and viral miRNAs-related immunomodulatory pathway was likely involved in this allergy process.


  • Open Access

    MS2 VLP-based delivery of microRNA-146a inhibits autoantibody production in lupus-prone mice

    by Yang Pan, Tingting Jia, Zhang, Jinming Li, Lunan Wang, Yuan Zhang, Kuo Zhang, Rui Zhang

    Background: Systemic lupus erythematosus (SLE) is a chronic autoimmune disease characterized by the presence of pathogenic autoantibodies. Recent studies suggest that microRNAs (miRNAs) play an essential role in immunoregulation and may be involved in the pathogenesis of SLE. Therefore, it was of interest to investigate the potential therapeutic application of miRNAs in SLE, a concept that has not been thoroughly investigated thus far. Virus-like particles (VLPs) are a type of recombinant nanoparticle enveloped by certain proteins derived from the outer coat of a virus. Herein, we describe a novel miRNA-delivery approach via bacteriophage MS2 VLPs and investigate the therapeutic effects of miR-146a, a well-studied and SLE-related miRNA, in BXSB lupus-prone mice. Methods: VLPs containing miR-146a, and the control VLPs, were prepared using an Escherichia coli expression system and then administered to lupus-prone mice over a 12-day period. We performed an enzyme-linked immunosorbent assay to evaluate the anti-dsDNA antibody, autoantibody to nuclear antigen (ANA), total IgG and total IgM levels in serum. The expression of miR-146a was analyzed by qRT-PCR. SLE-related cytokines as well as some toll-like receptor signaling pathway molecules were also measured. Results: Treatment with MS2-miR146a VLP showed profound effects on lupus-prone BXSB mice, including an increased level of mature miR-146a, which led to a significant reduction in the expression of autoantibodies and total IgG. Remarkably, these mice also exhibited reduced levels of proinflammatorycytokines, including IFN-Interferon-α (IFN-α), Interleukin-1β (Il-1β) and Interleukin-6 (Il-6). Moreover, we showed that the toll-like receptor pathway was involved in this regulation. Conclusion: Restoring the loss of miR-146a was effective in eliminating the production of autoantibodies and ameliorating SLE progression in lupus-prone mice. Thus, the induction of dysregulated miRNAs by an MS2 VLP-based delivery system may lead to novel therapies.


    • 18 October 2012
      • Vol. 44  (5) , 737-41

    [Construction and expression of virus-like particles containing rotavirus NSP3 gene].

    by Le Chang, Kuo Zhang, Rui Zhang, Jie-Hong Xie, Jin-Ming Li, Lu-Nan Wang

    To construct and express ribonuclease-resistant virus-like particles containing rotavirus NSP3 gene by changing the affinity of MS2 bacteriophage coat protein pac site and to discuss the stability. In the study, 1 049 bp rotavirus NSP3 gene fragments were amplified by PCR using the primers containing PvuI and KpnI restriction enzyme sites and the uridine at position -5 in the pac site was replaced with cytosine to increase the affinity. The gel-purified PCR-amplified DNA fragments and pACYC-MS2 vector were digested with PvuI and KpnI and then ligated to generate recombinant plasmid pACYC-MS2-NSP3. The expression vector was transformed into competent Escherichia coli strain TOP 10, and was verified by PCR and sequencing. The positive bacteria were transformed into competent E.coli strain BL21(DE3). Then the cells were lysed by ultrasonic disruption, virus like particles (VLPs) were harvested after purification and their stability was discussed. The expression plasmid containing mutant pac site (uridine at position -5 in the pac site replaced with cytosine) was constructed successfully and the ribonuclease-resistant virus-like particles containing rotavirus NSP3 gene were expressed successfully. The VLPs were resistant to ribonuclease and deoxyribonuclease, and were stable at -20 °C, 4 °C and room temperature(25 °C), respectively. The methods used to increase the affinity of pac site could successfully construct and express the VLPs. The VLPs containing rotavirus NSP3 gene are stable and could be used as surrogates for positive controls and standards in rotavirus real time fluorescent quantitative reverse transcription-PCR kits.

  • Open Access

    Development of a microRNA delivery system based on bacteriophage MS2 virus‐like particles

    by Yang Pan, Yuan Zhang, Tingting Jia, Kuo Zhang, Jinming Li, Lunan Wang

    Recently, microRNA (miRNA)‐mediated RNA interference has been developed as a useful tool in gene function analysis and gene therapy. A major obstacle in miRNA‐mediated RNAi is cellular delivery, which requires an efficient and flexible delivery system. The self‐assembly of the MS2 bacteriophage capsids has been used to develop virus‐like particles (VLPs) for RNA and drug delivery. However, MS2 VLP‐mediated miRNA delivery has not yet been reported. We therefore used an Escherichia coli expression system to produce the pre‐miR 146a contained MS2 VLPs, and then conjugated these particles with HIV‐1 Tat47–57 peptide. The conjugated MS2 VLPs effectively transferred the packaged pre‐miR146a RNA into various cells and tissues, with 0.92–14.76‐fold higher expression of miR‐146a in vitro and about two‐fold higher expression in vivo, and subsequently suppressed its targeting gene. These findings suggest that MS2 VLPs can be used as a novel vehicle in miRNA delivery systems, and may have applications in gene therapy.


  • Open Access

    Development of a new duplex real-time polymerase chain reaction assay for hepatitis B viral DNA detection

    by Shipeng Sun, Shuang Meng, Rui Zhang, Kuo Zhang, Lunan Wang, Jinming Li

    Background: Quantification of hepatitis B virus (HBV) DNA can be used for diagnosing HBV infection and monitoring the effect of antiviral therapy. However, probably because of mismatches between the template and primer/probe, HBV DNA in some HBV infections could not be detected using currently available commercial assays with single primer/probe. By aligning the HBV sequences, we developed a duplex real-time polymerase chain reaction (PCR) assay using two sets of primers/probes and a specific armored DNA as internal control (IC). Results: The limit of the duplex real-time PCR assay was 29.5 IU/ml, whereas the specificity was 100%. The within-run precision coefficient of variation (CV) ranged from 1.02% to 2.73%, while the between-run CV ranged from 0.83% to 1.25%. The optimal concentration of armored DNA IC in the HBV DNA duplex real-time PCR assay was 1 000 copies/ml. Data from 69 serum samples with HBV infection showed that the performance of the duplex real-time PCR assay was comparable to that of the COBAS Ampliprep/Cobas Taqman (CAP/CTM) HBV assay and was superior to those of the domestic commercial HBV assays. Conclusions: The duplex real-time PCR assay is sufficiently sensitive, specific, accurate, reproducible and cost-effective for the detection of HBV DNA. It is suitable for high throughput screening and frequent HBV DNA level monitoring.


  • Open Access

    Synthetic rabbit-human antibody conjugate as a control in immunoassays for immunoglobulin M specific to hepatitis E virus

    by Kuo Zhang, Lunan Wang, Min Liu, Rui Zhang, Jinming Li

    Background: In assays for anti-hepatitis E virus (HEV) immunoglobulin M (IgM), large volumes of the patient's sera cannot be easily obtained for use as a positive control. In this study, we investigated an alternative chemical method in which rabbit anti-HEV IgG was conjugated with human IgM and was used as a positive control in the anti-HEV IgM assay. Rabbit anti-HEV IgG was isolated from immune sera by chromatography on protein A-Sepharose and was conjugated with human IgM by using 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide (EDC) as a crosslinker. Results: The specific anti-HEV IgG antibody titer was 100,000 times that of the negative control, i.e., prebleed rabbit serum. The results of anti-HEV IgM enzyme-linked immunosobent assay showed that the antibody conjugate was similar to anti-HEV IgM antibodies produced in humans. The results of a stability experiment showed that the antibody conjugate was stable for use in external quality assessment or internal quality control trials. Conclusions: We concluded that the chemically conjugated rabbit-human antibody could be used instead of the traditional serum control as a positive control in the anti-HEV IgM assay.


    • 1 February 2007
      • Vol. 15  (2) , 107-10

    [Establishment of the first national standards for nucleic acid amplification technology assay for HBV DNA].

    by Lu-Nan Wang, Wei Deng, Zi-Yu Shen, Wen-Xiang Chen, Jin-Ming Li

    To establish a Chinese national standard for a nucleic acid test (NAT) for HBV DNA. The candidate sample of HBV DNA positive plasma was diluted with HBV-negative human plasma. The sample was lyophilised with a concentration of approximately 300,000 copies/ml. The measurement methods used included Roche Amplicor assay (version 2.0) and real-time PCR. The lyophilised preparation was calibrated by the international standard (NIBSC code: 97/746) from NIBSC. The quantity of this lyophilised preparation was (1.29+/-0.24) x 10(5)IU/ml in comparison with the international standard for HBV DNA 97/746. The stability test indicated that the sample was stable at room temperature (20 to 25 degrees C) for 2 weeks and at 37 degrees C for at least 1 week. Long-term stability was observed at 2 to 8 degrees C for 6 months and at -20 degrees C for more than 2 years with no significant changes. The vial-to-vial imprecision rate was 3.53%. Based on the results of this study, our lyophilized sample can be used as a standard in China for the nucleic acid test (NAT) for HBV DNA.

    • 1 August 2004
      • Vol. 12  (8) , 501-2

    [External quality assessment for detection of hepatitis B virus DNA in clinical laboratories of China].

    by Lu-Nan Wang, Jin-Ming Li, Wei Deng, Huai-Jing Zheng