Sabina Giusti
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Sabina Giusti has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
Carlo Bartolozzi
Department of Radiology, University of Pisa, Pisa, Italy
4 shared publications- Davide Caramella
Department of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, Pisa, Italy
4 shared publications Elena Fruzzetti
Department of Radiology, University of Pisa, Pisa, Italy
3 shared publications- Lorenzo Faggioni
Academic Radiology, Department of Translational Research and of New Surgical and Medical Technologies, University of Pisa, 56126 Pisa, Italy
2 shared publications A. Paolicchi
1 shared publicationAdele Tognetti
Division of Pathology,University of Pisa,Pisa,Italy
1 shared publication
Latest Publications
- 4 April 2012
- Published by Springer Nature in Abdominal Radiology
- Vol. 37 (6) , 1110-1121
Anatomical localization of deep infiltrating endometriosis: 3D MRI reconstructions
Purpose The goal of this study was to determine the accuracy of three-dimensional (3D) MRI reconstructions obtained with segmentation technique in the preoperative assessment of deep infiltrating endometriosis (DIE) and in particular to evaluate rectosigmoid and bladder wall involvement. Materials and methods Institutional review board approval for this study was obtained, and each patient gave written informed consent. Fifty-seven consecutive patients with diagnosis of DIE who had undergone pelvic MRI at 1.5 T before surgery between 2007 and 2011, were retrospectively evaluated and 3D post-processed in order to obtain a detailed mapping of DIE. A blinded reader interpreted images. MRI results were compared with surgical findings and were scored by using a four-point scale (0_3 score). Results 36/57 patients with symptomatic DIE underwent surgery: 18/36 had endometriotic nodules infiltrating the rectouterine pouch, 12/36 the vesicouterine pouch, and 6/36 the rectovaginal pouch. The sensitivity of MRI and 3D MRI vs. surgery was, respectively, 64% vs. 83%; diagnostic accuracy of 3D MRI respect to MRI alone was 86% vs. 67% for localization; 86% vs. 67% for dimension; 79% vs. 58% for rectosigmoid infiltration; 92% vs. 75% for bladder infiltration. Conclusions In this preliminary study, 3D MRI reconstructions obtained with semi-automatic method of segmentation provided encouraging results for staging DIE preoperatively. In fact, the addition of 3D MRI reconstructions improved diagnostic accuracy and staging of DIE providing the exact volume of the lesions and enabling a precise mapping of these before surgery.
- 4 April 2012
- Published by Springer Nature in Abdominal Radiology
- Vol. 37 (6) , 1110-1121
Anatomical localization of deep infiltrating endometriosis: 3D MRI reconstructions
Purpose The goal of this study was to determine the accuracy of three-dimensional (3D) MRI reconstructions obtained with segmentation technique in the preoperative assessment of deep infiltrating endometriosis (DIE) and in particular to evaluate rectosigmoid and bladder wall involvement. Materials and methods Institutional review board approval for this study was obtained, and each patient gave written informed consent. Fifty-seven consecutive patients with diagnosis of DIE who had undergone pelvic MRI at 1.5 T before surgery between 2007 and 2011, were retrospectively evaluated and 3D post-processed in order to obtain a detailed mapping of DIE. A blinded reader interpreted images. MRI results were compared with surgical findings and were scored by using a four-point scale (0_3 score). Results 36/57 patients with symptomatic DIE underwent surgery: 18/36 had endometriotic nodules infiltrating the rectouterine pouch, 12/36 the vesicouterine pouch, and 6/36 the rectovaginal pouch. The sensitivity of MRI and 3D MRI vs. surgery was, respectively, 64% vs. 83%; diagnostic accuracy of 3D MRI respect to MRI alone was 86% vs. 67% for localization; 86% vs. 67% for dimension; 79% vs. 58% for rectosigmoid infiltration; 92% vs. 75% for bladder infiltration. Conclusions In this preliminary study, 3D MRI reconstructions obtained with semi-automatic method of segmentation provided encouraging results for staging DIE preoperatively. In fact, the addition of 3D MRI reconstructions improved diagnostic accuracy and staging of DIE providing the exact volume of the lesions and enabling a precise mapping of these before surgery.
- Open Access
- 5 March 2012
- Published by Springer Nature in Radiation Oncology
- Vol. 7 (1) , 29
Preoperative rectal cancer staging with phased-array MR
We retrospectively reviewed magnetic resonance (MR) images of 96 patients with diagnosis of rectal cancer to evaluate tumour stage (T stage), involvement of mesorectal fascia (MRF), and nodal metastasis (N stage).
- 5 March 2012
- Published by Springer Nature in Radiation Oncology
- Vol. 7 (1) , 29
Open AccessPreoperative rectal cancer staging with phased-array MR
We retrospectively reviewed magnetic resonance (MR) images of 96 patients with diagnosis of rectal cancer to evaluate tumour stage (T stage), involvement of mesorectal fascia (MRF), and nodal metastasis (N stage).
- 28 May 2010
- Published by Springer Nature in Abdominal Radiology
- Vol. 35 (6) , 646-653
Dynamic MRI of the small bowel: usefulness of quantitative contrast-enhancement parameters and time–signal intensity curves for differentiating between active and inactive Crohn’s disease
Purpose To assess Crohn’s disease (CD) activity through analysis of time–signal intensity curves and quantitative contrast-enhancement parameters on dynamic contrast-enhanced MRI. Materials and methods 70 patients (male:female = 44:26, age 15–45 years, mean 27.8 years) with biopsy-proven clinically active or inactive CD, underwent dynamic contrast-enhanced MRI after oral administration of iso-osmotic solution. Time–signal intensity curves were classified according to their shape as type I (early upslope with late plateau) and type II (slow contrast material wash-in with late wash-out). Curve parameters such as maximum enhancement (ME), the ratio between late and ME (LE/ME), and UpSlope (US) were compared between patients with active and inactive CD (two-tailed Mann–Whitney test). Sensitivity, specificity, and cut-off for each parameter were calculated by means of receiver operating characteristic curve (ROC) analysis. Results 53/53 patients with active CD and 17/17 with inactive CD showed type I and type II curves, respectively. ME, LE/ME, and US were significantly higher in active than in inactive CD. ME, LE/ME, and US had sensitivity and specificity of 100%:100%:100% and 100%:83%:100% with cut-offs of 135.5:0.8909:2, respectively. Conclusions Qualitative and quantitative analysis of time–signal intensity curves obtained with dynamic contrast-enhanced MRI allow reliable noninvasive differentiation between active and inactive CD.
- 28 May 2010
- Published by Springer Nature in Abdominal Radiology
- Vol. 35 (6) , 646-653
Dynamic MRI of the small bowel: usefulness of quantitative contrast-enhancement parameters and time–signal intensity curves for differentiating between active and inactive Crohn’s disease
Purpose To assess Crohn’s disease (CD) activity through analysis of time–signal intensity curves and quantitative contrast-enhancement parameters on dynamic contrast-enhanced MRI. Materials and methods 70 patients (male:female = 44:26, age 15–45 years, mean 27.8 years) with biopsy-proven clinically active or inactive CD, underwent dynamic contrast-enhanced MRI after oral administration of iso-osmotic solution. Time–signal intensity curves were classified according to their shape as type I (early upslope with late plateau) and type II (slow contrast material wash-in with late wash-out). Curve parameters such as maximum enhancement (ME), the ratio between late and ME (LE/ME), and UpSlope (US) were compared between patients with active and inactive CD (two-tailed Mann–Whitney test). Sensitivity, specificity, and cut-off for each parameter were calculated by means of receiver operating characteristic curve (ROC) analysis. Results 53/53 patients with active CD and 17/17 with inactive CD showed type I and type II curves, respectively. ME, LE/ME, and US were significantly higher in active than in inactive CD. ME, LE/ME, and US had sensitivity and specificity of 100%:100%:100% and 100%:83%:100% with cut-offs of 135.5:0.8909:2, respectively. Conclusions Qualitative and quantitative analysis of time–signal intensity curves obtained with dynamic contrast-enhanced MRI allow reliable noninvasive differentiation between active and inactive CD.
- 1 January 2010
- Published by Springer Nature
- p. 139-148
I mezzi di contrasto in TC
- 12 September 2009
- Published by Springer Nature in Abdominal Radiology
- Vol. 35 (6) , 757-763
Peripheral zone prostate cancer. Pre-treatment evaluation with MR and 3D 1H MR spectroscopic imaging: correlation with pathologic findings
The purpose of this study was to retrospectively characterize benign and malignant prostate peripheral zone tissue by using endorectal MRI and 3D ¹H MRS. Fifty-two men with untreated biopsy-proven prostate cancer underwent combined endorectal MRI and MRSI. Whole-mount step-section histopathologic analysis constituted the reference standard. Biopsy correctly detected 74 locations; MRI correctly detected 72 locations; MRS correctly detected 72 locations; MRI + MRS correctly detected 78 locations. Cohen's test showed that biopsy had a lower degree of agreement with histology than MRI + MRS combined. The ratio of [(Cho + Cr)]/Cit correlates with the pathologic Gleason score. The addition of 3D¹H MRSI to MRI can improve diagnosis of prostate cancer contributing indirectly to improve local staging. In addition, the correlation between metabolic 3D¹H MRSI data with pathological Gleason grade may offer a non-invasive means to better predict prostate cancer aggressiveness.
- 12 September 2009
- Published by Springer Nature in Abdominal Radiology
- Vol. 35 (6) , 757-763
Peripheral zone prostate cancer. Pre-treatment evaluation with MR and 3D 1H MR spectroscopic imaging: correlation with pathologic findings
The purpose of this study was to retrospectively characterize benign and malignant prostate peripheral zone tissue by using endorectal MRI and 3D ¹H MRS. Fifty-two men with untreated biopsy-proven prostate cancer underwent combined endorectal MRI and MRSI. Whole-mount step-section histopathologic analysis constituted the reference standard. Biopsy correctly detected 74 locations; MRI correctly detected 72 locations; MRS correctly detected 72 locations; MRI + MRS correctly detected 78 locations. Cohen's test showed that biopsy had a lower degree of agreement with histology than MRI + MRS combined. The ratio of [(Cho + Cr)]/Cit correlates with the pathologic Gleason score. The addition of 3D¹H MRSI to MRI can improve diagnosis of prostate cancer contributing indirectly to improve local staging. In addition, the correlation between metabolic 3D¹H MRSI data with pathological Gleason grade may offer a non-invasive means to better predict prostate cancer aggressiveness.
- 31 March 2005
- Published by Elsevier in Digestive and Liver Disease
- Vol. 37 (3) , 200-205
Hepatocellular adenoma: imaging findings and pathological correlation
- 31 March 2005
- Published by Elsevier in Digestive and Liver Disease
- Vol. 37 (3) , 200-205
Hepatocellular adenoma: imaging findings and pathological correlation
- 27 November 2004
- Published by Springer Nature in European Radiology
- Vol. 14 (12) , 2368-2371
Ileal invaginated Meckel?s diverticulum: imaging diagnosis (2004:9b)
- 27 November 2004
- Published by Springer Nature in European Radiology
- Vol. 14 (12) , 2368-2371
Ileal invaginated Meckel?s diverticulum: imaging diagnosis (2004:9b)