Po-Quang Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Po-Quang Chen has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Son‐Jyh Lin
Department of Mechanical Engineering , National Taiwan University , Taipei, Taiwan 106, R.O.C.
2 shared publications- Chee-Huan Pan
Department of Orthopaedic Surgery, National Taiwan University Hospital, No. 7. Chung San South Road, Taipei 100, Taiwan
1 shared publication Chien-Chung Lin
Department of Orthopaedic Surgery, Taipei City Hospital, Taiwan
1 shared publication- Ching-Hsiao Yu
Department of Orthopedic Surgery, Taoyuan General Hospital, Ministry of Health and Welfare, Taoyuan City, Taiwan
1 shared publication Chun‐Ching Hsiao
Department of Mechanical Engineering , National Taiwan University of Science and Technology , Taipei, Taiwan 106, R.O.C.
1 shared publicationJinn Lin
Department of Orthopaedic Surgery, National Taiwan University Hospital, Taipei
1 shared publication
Latest Publications
- Open Access
- 19 February 2012
- Published by Springer Nature in Scoliosis and Spinal Disorders
- Vol. 7 (1) , 5
Segmental correction of adolescent idiopathic scoliosis by all-screw fixation method in adolescents and young adults. minimum 5 years follow-up with SF-36 questionnaire
In our institution, the fixation technique in treating idiopathic scoliosis was shifted from hybrid fixation to the all-screw method beginning in 2000. We conducted this study to assess the intermediate -term outcome of all-screw method in treating adolescent idiopathic scoliosis (AIS).
- 19 February 2012
- Published by Springer Nature in Scoliosis and Spinal Disorders
- Vol. 7 (1) , 5
Open AccessSegmental correction of adolescent idiopathic scoliosis by all-screw fixation method in adolescents and young adults. minimum 5 years follow-up with SF-36 questionnaire
In our institution, the fixation technique in treating idiopathic scoliosis was shifted from hybrid fixation to the all-screw method beginning in 2000. We conducted this study to assess the intermediate -term outcome of all-screw method in treating adolescent idiopathic scoliosis (AIS).
- 1 March 2006
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 444, 209-215
Prognosis Of Operative Treatment for Metastatic Hepatocellular Carcinoma of the Spine
Developing and developed countries have been reported increasing numbers of hepatocellular carcinoma and increased rates of distant metastasis from hepatocellular carcinoma. Data regarding operative treatments and prognoses of hepatocellular carcinoma metastasis to the spine are lacking in the literature. We retrospectively reviewed 12 patients with hepatocellular carcinoma and metastasis to the spine who had spinal surgery between 1986 and 1996. All 12 patients had severe back pain preoperatively. Posterior surgery alone was performed on two patients, anterior surgery alone in six patients, and combined anterior and posterior surgery in four. Ten of the 12 patients experienced pain relief and their neurologic status was preserved or improved. We designed a new outcome assessment, a modified Prolo scale, to evaluate surgical outcome. Seven of the 12 patients had good or excellent results. Our sample size was limited and we could draw no definite conclusions regarding the prognoses of these patients or the value of surgical intervention; however, we think that operative treatment for spinal metastatic hepatocellular carcinoma lesions may improve quality of life, regardless whether the survival time is prolonged. Level of Evidence: Therapeutic study, Level IV (case series-no, or historical, control group). See the Guidelines for Authors for a complete description of levels of evidence.
- 1 March 2006
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 444, 209-215
Prognosis Of Operative Treatment for Metastatic Hepatocellular Carcinoma of the Spine
Developing and developed countries have been reported increasing numbers of hepatocellular carcinoma and increased rates of distant metastasis from hepatocellular carcinoma. Data regarding operative treatments and prognoses of hepatocellular carcinoma metastasis to the spine are lacking in the literature. We retrospectively reviewed 12 patients with hepatocellular carcinoma and metastasis to the spine who had spinal surgery between 1986 and 1996. All 12 patients had severe back pain preoperatively. Posterior surgery alone was performed on two patients, anterior surgery alone in six patients, and combined anterior and posterior surgery in four. Ten of the 12 patients experienced pain relief and their neurologic status was preserved or improved. We designed a new outcome assessment, a modified Prolo scale, to evaluate surgical outcome. Seven of the 12 patients had good or excellent results. Our sample size was limited and we could draw no definite conclusions regarding the prognoses of these patients or the value of surgical intervention; however, we think that operative treatment for spinal metastatic hepatocellular carcinoma lesions may improve quality of life, regardless whether the survival time is prolonged. Level of Evidence: Therapeutic study, Level IV (case series-no, or historical, control group). See the Guidelines for Authors for a complete description of levels of evidence.
- Open Access
- 16 March 2004
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 5 (1) , 8
Multiple parallel skin markers for minimal incision lumbar disc surgery; a technical note
- 16 March 2004
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 5 (1) , 8
Open AccessMultiple parallel skin markers for minimal incision lumbar disc surgery; a technical note
- 1 March 2003
- Published by Taylor & Francis in Journal of the Chinese Institute of Engineers
- Vol. 26 (2) , 165-172
Optimal alignment of the distal screws in the tibial nailing
Serious stress concentration around the regions near the distal nail‐holes and the distal screws in conventional tibial interlocking nails has been reported in previous studies. A three‐dimensional finite element model was used to study the interlocking nail, the fractured tibia and the locking screws. The distal screws were inserted into the tibial nail in different configurations. We found that the maximal tensile stress of the nail‐screw system can be substantially decreased with the two distal screws configured in the anterior to posterior direction. In a distal or comminuted diaphyseal fracture of the tibia, the optimal alignment of the two distal screws was in the anterior to posterior direction and the nail‐screw system with this alignment can bear greater loading in the more demanding fracture patterns.
- 1 March 2003
- Published by Taylor & Francis in Journal of the Chinese Institute of Engineers
- Vol. 26 (2) , 165-172
Optimal alignment of the distal screws in the tibial nailing
Serious stress concentration around the regions near the distal nail‐holes and the distal screws in conventional tibial interlocking nails has been reported in previous studies. A three‐dimensional finite element model was used to study the interlocking nail, the fractured tibia and the locking screws. The distal screws were inserted into the tibial nail in different configurations. We found that the maximal tensile stress of the nail‐screw system can be substantially decreased with the two distal screws configured in the anterior to posterior direction. In a distal or comminuted diaphyseal fracture of the tibia, the optimal alignment of the two distal screws was in the anterior to posterior direction and the nail‐screw system with this alignment can bear greater loading in the more demanding fracture patterns.
- 1 January 2001
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 19 (1) , 57-63
Stress analysis of the distal locking screws for femoral interlocking nailing
In femoral locked nailing, the distal locking screws are vulnerable to mechanical failure. Biomechanical studies have shown that the stress on these screws is substantially affected by the fit of the nail in the medullary canal. In this study, a “closed form” mathematical model based on elastic beam‐column theory was developed to investigate how the nail‐cortical contact, which was simulated by a linear elastic foundation, affected the stress on the distal locking screws. Providing data for the model was a construct of a fractured femur with an intramedullary locked nail loaded by an eccentric vertical load. The stress on the locking screw was analyzed as a function of the distance from the fracture to the locking screw in the distal fragment under two situations: with and without nail‐cortical contact in the distal fragment. With nail‐cortical contact, the screw stress decreased as the length of nail‐cortical contact and the distance between the distal locking screw and the fracture site increased, but this stress contrarily increased when the nail reached the femoral region at which the screw length increased. The screw stress was much higher without nail‐cortical contact than with contact and continued to increase as the nail was inserted further. The mathematical model developed here can be a convenient means of rapid stress evaluation and parametric analysis for locked femoral nailing. It may be used to improve the design of interlocking nails and surgical technique. © 2001 Orthopaedic Research Society. Published by Elsevier Science Ltd. All rights reserved.
- 1 January 2001
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 19 (1) , 57-63
Stress analysis of the distal locking screws for femoral interlocking nailing
In femoral locked nailing, the distal locking screws are vulnerable to mechanical failure. Biomechanical studies have shown that the stress on these screws is substantially affected by the fit of the nail in the medullary canal. In this study, a “closed form” mathematical model based on elastic beam‐column theory was developed to investigate how the nail‐cortical contact, which was simulated by a linear elastic foundation, affected the stress on the distal locking screws. Providing data for the model was a construct of a fractured femur with an intramedullary locked nail loaded by an eccentric vertical load. The stress on the locking screw was analyzed as a function of the distance from the fracture to the locking screw in the distal fragment under two situations: with and without nail‐cortical contact in the distal fragment. With nail‐cortical contact, the screw stress decreased as the length of nail‐cortical contact and the distance between the distal locking screw and the fracture site increased, but this stress contrarily increased when the nail reached the femoral region at which the screw length increased. The screw stress was much higher without nail‐cortical contact than with contact and continued to increase as the nail was inserted further. The mathematical model developed here can be a convenient means of rapid stress evaluation and parametric analysis for locked femoral nailing. It may be used to improve the design of interlocking nails and surgical technique. © 2001 Orthopaedic Research Society. Published by Elsevier Science Ltd. All rights reserved.