Paul Mohacsi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Paul Mohacsi has a total of 118 co-authors. Here are the top co-authors by number of shared publications:
Jan Gummert
Herz- und Diabeteszentrum NRW, Bad Oeynhausen, Germany
3 shared publicationsLars Englberger
Department of Cardiovascular Surgery, Swiss Cardiovascular Centre, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
3 shared publicationsPascal Leprince
Université Pierre et Marie Curie, Hôpital La-Pitié Salpetrière, Paris, France
3 shared publications- Robert Rieben
Department for BioMedical Research (DBMR) University of Bern Bern Switzerland
3 shared publications Roland Hetzer
Cardio Centrum Berlin, Berlin, Germany
3 shared publicationsThierry Carrel
Department of Cardiology and Cardiovascular Surgery, University Hospital Bern, Bern, Switzerland
3 shared publications
Latest Publications
- 25 November 2017
- Published by Springer Nature in Metabolomics
- Vol. 14 (1) , 1-11
Targeted and global pharmacometabolomics in everolimus-based immunosuppression: association of co-medication and lysophosphatidylcholines with dose requirement
Introduction The immunosuppressive therapy with everolimus (ERL) after heart transplantation is characterized by a narrow therapeutic window and a substantial variability in dose requirement. Factors explaining this variability are largely unknown. Objectives Our aim was to evaluate factors affecting ERL metabolism and to identify novel metabolites associated with the individual ERL dose requirement to elucidate mechanisms underlying ERL dose response variability. Method We used liquid chromatography coupled with mass spectrometry for quantification of ERL metabolites in 41 heart transplant patients and evaluated the effect of clinical and genetic factors on ERL pharmacokinetics. Non-targeted plasma metabolic profiling by ultra-performance liquid chromatography and high resolution quadrupole-time-of-flight mass spectrometry was used to identify novel metabolites associated with ERL dose requirement. Results The determination of ERL metabolites revealed differences in metabolite patterns that were independent from clinical or genetic factors. Whereas higher ERL dose requirement was associated with co-administration of sodium-mycophenolic acid and the CYP3A5 expressor genotype, lower dose was required for patients receiving vitamin K antagonists. Global metabolic profiling revealed several novel metabolites associated with ERL dose requirement. One of them was identified as lysophosphatidylcholine (lysoPC) (16:0/0:0). Subsequent targeted analysis revealed that high levels of several lysoPCs were significantly associated with higher ERL dose requirement. Conclusion For the first time, this study describes distinct ERL metabolite patterns in heart transplant patients and detected potentially new drug–drug interactions. The global metabolic profiling facilitated the discovery of novel metabolites associated with ERL dose requirement that might represent new clinically valuable biomarkers to guide ERL therapy.
- 25 November 2017
- Published by Springer Nature in Metabolomics
- Vol. 14 (1) , 1-11
Targeted and global pharmacometabolomics in everolimus-based immunosuppression: association of co-medication and lysophosphatidylcholines with dose requirement
Introduction The immunosuppressive therapy with everolimus (ERL) after heart transplantation is characterized by a narrow therapeutic window and a substantial variability in dose requirement. Factors explaining this variability are largely unknown. Objectives Our aim was to evaluate factors affecting ERL metabolism and to identify novel metabolites associated with the individual ERL dose requirement to elucidate mechanisms underlying ERL dose response variability. Method We used liquid chromatography coupled with mass spectrometry for quantification of ERL metabolites in 41 heart transplant patients and evaluated the effect of clinical and genetic factors on ERL pharmacokinetics. Non-targeted plasma metabolic profiling by ultra-performance liquid chromatography and high resolution quadrupole-time-of-flight mass spectrometry was used to identify novel metabolites associated with ERL dose requirement. Results The determination of ERL metabolites revealed differences in metabolite patterns that were independent from clinical or genetic factors. Whereas higher ERL dose requirement was associated with co-administration of sodium-mycophenolic acid and the CYP3A5 expressor genotype, lower dose was required for patients receiving vitamin K antagonists. Global metabolic profiling revealed several novel metabolites associated with ERL dose requirement. One of them was identified as lysophosphatidylcholine (lysoPC) (16:0/0:0). Subsequent targeted analysis revealed that high levels of several lysoPCs were significantly associated with higher ERL dose requirement. Conclusion For the first time, this study describes distinct ERL metabolite patterns in heart transplant patients and detected potentially new drug–drug interactions. The global metabolic profiling facilitated the discovery of novel metabolites associated with ERL dose requirement that might represent new clinically valuable biomarkers to guide ERL therapy.
- Open Access
- 29 September 2017
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 53 (2) , 309-316
The European Registry for Patients with Mechanical Circulatory Support (EUROMACS) of the European Association for Cardio-Thoracic Surgery (EACTS): second report
The European Registry for Patients with Mechanical Circulatory Support (EUROMACS) was founded in Berlin, Germany. EUROMACS is supported fully by the European Association for Cardio-Thoracic Surgery (EACTS) and, since 2014, has functioned as a committee of the EACTS. The purpose of having the EUROMACS as a part of the EACTS is to accumulate clinical data related to long-term mechanical circulatory support for scientific purposes and to publish annual reports. Participating hospitals contributed surgical and cardiological pre-, peri- and long-term postoperative data of mechanical circulatory support implants to the registry. Data for all implants performed from 1 January 2011 to 31 December 2016 were analysed. Several auditing methods were used to monitor the quality of the data. Data could be provided for in-depth studies, and custom data could be provided at the request of clinicians and scientists. This report includes updates of patient characteristics, implant frequency, mortality rates and adverse events. Fifty-two hospitals participated in the registry. This report is based on 2947 registered implants in 2681 patients. Survival of adult patients (>17 years of age) with continuous-flow left ventricular assist devices with a mean follow-up of 391 days was 69% (95% confidence interval 66–71%) 1 year after implantation. On average, patients were observed for 12 months (median 7 months, range 0–70 months). When we investigated for adverse events, we found an overall event rate per 100 patient-months of 3.56 for device malfunction, 6.45 for major bleeding, 6.18 for major infection and 3.03 for neurological events within the first 3 months after implantation. Compared to the first EUROMACS report, the number of participating hospitals increased from 21 to 52 (+148%), whereas the number of registered implants more than tripled from 825 to 2947 (+257%). The increase in the number of participating hospitals led us to increase the quality control measures through data input control, on-site audits and statistical analyses.
- 29 September 2017
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 53 (2) , 309-316
Open AccessThe European Registry for Patients with Mechanical Circulatory Support (EUROMACS) of the European Association for Cardio-Thoracic Surgery (EACTS): second report
The European Registry for Patients with Mechanical Circulatory Support (EUROMACS) was founded in Berlin, Germany. EUROMACS is supported fully by the European Association for Cardio-Thoracic Surgery (EACTS) and, since 2014, has functioned as a committee of the EACTS. The purpose of having the EUROMACS as a part of the EACTS is to accumulate clinical data related to long-term mechanical circulatory support for scientific purposes and to publish annual reports. Participating hospitals contributed surgical and cardiological pre-, peri- and long-term postoperative data of mechanical circulatory support implants to the registry. Data for all implants performed from 1 January 2011 to 31 December 2016 were analysed. Several auditing methods were used to monitor the quality of the data. Data could be provided for in-depth studies, and custom data could be provided at the request of clinicians and scientists. This report includes updates of patient characteristics, implant frequency, mortality rates and adverse events. Fifty-two hospitals participated in the registry. This report is based on 2947 registered implants in 2681 patients. Survival of adult patients (>17 years of age) with continuous-flow left ventricular assist devices with a mean follow-up of 391 days was 69% (95% confidence interval 66–71%) 1 year after implantation. On average, patients were observed for 12 months (median 7 months, range 0–70 months). When we investigated for adverse events, we found an overall event rate per 100 patient-months of 3.56 for device malfunction, 6.45 for major bleeding, 6.18 for major infection and 3.03 for neurological events within the first 3 months after implantation. Compared to the first EUROMACS report, the number of participating hospitals increased from 21 to 52 (+148%), whereas the number of registered implants more than tripled from 825 to 2947 (+257%). The increase in the number of participating hospitals led us to increase the quality control measures through data input control, on-site audits and statistical analyses.
- Open Access
- 1 June 2017
- Published by Wolters Kluwer Health in Current Opinion in Organ Transplantation
- Vol. 22 (3) , 225-230
New role of ventricular assist devices as bridge to transplantation
Progress of ventricular assist devices (VAD) technology led to improved survival and apparently low morbidity. However, from the European perspective, updated analysis of EUROMACS reveals a somewhat less impressive picture with respect to mortality and morbidity. We describe the great demand of cardiac allografts versus the lack of donors, which is larger in Europe than in the United States. Technical progress of VADs made it possible to work out a modern algorithm of bridge-to-transplant, which is tailored to the need of the particular patient. We analyze the burden of patients undergoing bridge-to-transplant therapy. They are condemned to an intermediate step, coupled with additional major surgery and potential adverse events during heart transplantation. Based on current registry data, we do have to question the increasingly popular opinion, that the concept of heart transplantation is futureless, which seems to be for someone who treats and compares both patients (VAD and heart transplantation) in daily practice, questionable. Up to now, left ventricular assist device therapy remains a bridge to a better future, which means a bridge to technical innovations or to overcome the dramatic lack of donors in Europe.
- 1 June 2017
- Published by Wolters Kluwer Health in Current Opinion in Organ Transplantation
- Vol. 22 (3) , 225-230
Open AccessNew role of ventricular assist devices as bridge to transplantation
Progress of ventricular assist devices (VAD) technology led to improved survival and apparently low morbidity. However, from the European perspective, updated analysis of EUROMACS reveals a somewhat less impressive picture with respect to mortality and morbidity. We describe the great demand of cardiac allografts versus the lack of donors, which is larger in Europe than in the United States. Technical progress of VADs made it possible to work out a modern algorithm of bridge-to-transplant, which is tailored to the need of the particular patient. We analyze the burden of patients undergoing bridge-to-transplant therapy. They are condemned to an intermediate step, coupled with additional major surgery and potential adverse events during heart transplantation. Based on current registry data, we do have to question the increasingly popular opinion, that the concept of heart transplantation is futureless, which seems to be for someone who treats and compares both patients (VAD and heart transplantation) in daily practice, questionable. Up to now, left ventricular assist device therapy remains a bridge to a better future, which means a bridge to technical innovations or to overcome the dramatic lack of donors in Europe.
- 27 October 2016
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 51 (1) , 127-134
Mid-term mechanical circulatory support: comparison of single-centre data with the EUROMACS registry
Mechanical circulatory support (MCS) is an established therapy for end-stage heart failure. The EUROMACS registry was created to promote research in patients with MCS and became a committee of the European Association for Cardio-Thoracic Surgery (EACTS) in 2014. Since 1 January 2011, increasing numbers of European centres implanting durable MCS have reported their patient data to EUROMACS. The aim of this study is to compare, as an example of internal quality control, data from a single centre (Bern) with those from the EUROMACS database with respect to mortality rates and preoperative patient characteristics and to describe complications in Bern. Patients implanted with MCS between 1 January 2011 and 30 June 2014 in participating centres were included, with extended follow-up as of 31 December 2014. Patient characteristics, operative and postoperative data, clinically significant adverse events and routine follow-up data were reported to the registry. The entire EUROMACS cohort (including the Bern data) was compared with patients from Bern only. Baseline characteristics, operative data and outcomes were compared using standard 95% confidence intervals (CIs) for means, Wilson's continuity corrected CIs for categories and Kaplan–Meier estimates with CIs. Kaplan–Meier estimates show a higher survival rate in the Bern cohort than in the entire EUROMACS cohort at 6 (92%, CI 73–98, vs 66%, CI 62–69), 12 (85%, CI 57–95, vs 56%, CI 52–60) and 18 months (85%, CI 57–95, vs 51%, CI 47–55) after the index operation, respectively. This difference might be caused by the earlier implantation time in Bern (implantation at INTERMACS levels 3–4) versus that of the entire EUROMACS cohort (implantation at INTERMACS levels 2–3). The median number of follow-up records per patient was 2 in the entire EUROMACS cohort and 4 in the Bern (P = 0.001) cohort. During follow-up, neurological dysfunction occurred in 42% of patients, a bleeding event occurred in 42% of patients, significant infection occurred in 36% of patients and a device malfunction occurred in 31% of patients within 12 months of implantation in the Bern patients. MCS is a valuable therapeutic option with excellent survival rates; nevertheless, it is associated with clinically significant complication rates. International registries are important tools that allow, as an example, internal quality control of mortality, complication and morbidity rates from a single centre compared with the EUROMACS database.
- 27 October 2016
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 51 (1) , 127-134
Mid-term mechanical circulatory support: comparison of single-centre data with the EUROMACS registry
Mechanical circulatory support (MCS) is an established therapy for end-stage heart failure. The EUROMACS registry was created to promote research in patients with MCS and became a committee of the European Association for Cardio-Thoracic Surgery (EACTS) in 2014. Since 1 January 2011, increasing numbers of European centres implanting durable MCS have reported their patient data to EUROMACS. The aim of this study is to compare, as an example of internal quality control, data from a single centre (Bern) with those from the EUROMACS database with respect to mortality rates and preoperative patient characteristics and to describe complications in Bern. Patients implanted with MCS between 1 January 2011 and 30 June 2014 in participating centres were included, with extended follow-up as of 31 December 2014. Patient characteristics, operative and postoperative data, clinically significant adverse events and routine follow-up data were reported to the registry. The entire EUROMACS cohort (including the Bern data) was compared with patients from Bern only. Baseline characteristics, operative data and outcomes were compared using standard 95% confidence intervals (CIs) for means, Wilson's continuity corrected CIs for categories and Kaplan–Meier estimates with CIs. Kaplan–Meier estimates show a higher survival rate in the Bern cohort than in the entire EUROMACS cohort at 6 (92%, CI 73–98, vs 66%, CI 62–69), 12 (85%, CI 57–95, vs 56%, CI 52–60) and 18 months (85%, CI 57–95, vs 51%, CI 47–55) after the index operation, respectively. This difference might be caused by the earlier implantation time in Bern (implantation at INTERMACS levels 3–4) versus that of the entire EUROMACS cohort (implantation at INTERMACS levels 2–3). The median number of follow-up records per patient was 2 in the entire EUROMACS cohort and 4 in the Bern (P = 0.001) cohort. During follow-up, neurological dysfunction occurred in 42% of patients, a bleeding event occurred in 42% of patients, significant infection occurred in 36% of patients and a device malfunction occurred in 31% of patients within 12 months of implantation in the Bern patients. MCS is a valuable therapeutic option with excellent survival rates; nevertheless, it is associated with clinically significant complication rates. International registries are important tools that allow, as an example, internal quality control of mortality, complication and morbidity rates from a single centre compared with the EUROMACS database.
- Open Access
- 8 July 2016
- Published by Springer Nature in BMC Infectious Diseases
- Vol. 16 (1) , 321
Ventricular assist devices as bridge to heart transplantation: impact on post-transplant infections
Ventricular assist devices (VAD) are valuable options for patients with heart failure awaiting cardiac transplantation. We assessed the impact of pre-transplant VAD implantation on the incidence of post-transplant infections in a nationwide cohort of heart transplant recipients. Heart transplant recipients included in the Swiss Transplant Cohort Study between May 2008 and December 2012 were analyzed. Cumulative incidence curves were used to calculate the incidence of bacterial or Candida infections (primary endpoint) and of other infections (secondary endpoint) after transplant. Cox regression models treating death as a competing risk were used to identify risk factors for the development of infection after transplant. Overall, 119 patients were included in the study, 35 with a VAD and 84 without VAD. Cumulative incidences of post-transplant bacterial or Candida infections were 37.7 % in VAD patients and 40.4 % in non-VAD patients. In multivariate analysis, the use of cotrimoxazole prophylaxis was the only variable associated with bacterial/Candida infections after transplant (HR 0.29 [95 % CI 0.15-0.57], p < 0.001), but presence of a VAD was not (HR 0.94, [95 % CI 0.38-2.32], p = 0.89, for continuous-flow devices, and HR 0.45 [0.15 – 1.34], p = 0.15, for other devices). Risk for post-transplant viral and all fungal infections was not increased in patients with VAD. One-year survival was 82.9 % (29/35) in the VAD group and 82.1 % (69/84) in the non-VAD group. All 6 patients in the VAD group that died after transplant had a history of pre-transplant VAD infection. In this nationwide cohort of heart transplant recipients, the presence of VAD at the time of transplant had no influence on the development of post-transplant infections.
- 8 July 2016
- Published by Springer Nature in BMC Infectious Diseases
- Vol. 16 (1) , 321
Open AccessVentricular assist devices as bridge to heart transplantation: impact on post-transplant infections
Ventricular assist devices (VAD) are valuable options for patients with heart failure awaiting cardiac transplantation. We assessed the impact of pre-transplant VAD implantation on the incidence of post-transplant infections in a nationwide cohort of heart transplant recipients. Heart transplant recipients included in the Swiss Transplant Cohort Study between May 2008 and December 2012 were analyzed. Cumulative incidence curves were used to calculate the incidence of bacterial or Candida infections (primary endpoint) and of other infections (secondary endpoint) after transplant. Cox regression models treating death as a competing risk were used to identify risk factors for the development of infection after transplant. Overall, 119 patients were included in the study, 35 with a VAD and 84 without VAD. Cumulative incidences of post-transplant bacterial or Candida infections were 37.7 % in VAD patients and 40.4 % in non-VAD patients. In multivariate analysis, the use of cotrimoxazole prophylaxis was the only variable associated with bacterial/Candida infections after transplant (HR 0.29 [95 % CI 0.15-0.57], p < 0.001), but presence of a VAD was not (HR 0.94, [95 % CI 0.38-2.32], p = 0.89, for continuous-flow devices, and HR 0.45 [0.15 – 1.34], p = 0.15, for other devices). Risk for post-transplant viral and all fungal infections was not increased in patients with VAD. One-year survival was 82.9 % (29/35) in the VAD group and 82.1 % (69/84) in the non-VAD group. All 6 patients in the VAD group that died after transplant had a history of pre-transplant VAD infection. In this nationwide cohort of heart transplant recipients, the presence of VAD at the time of transplant had no influence on the development of post-transplant infections.
- 23 November 2015
- Published by Wiley in Clinical Transplantation
- Vol. 29 (12) , 1213-1220
Influence of CYP3A5 genetic variation on everolimus maintenance dosing after cardiac transplantation
Background: Everolimus (ERL) has become an alternative to calcineurin inhibitors (CNIs) due to its renal‐sparing properties, especially in heart transplant (HTx) recipients with kidney dysfunction. However, ERL dosing is challenging due to its narrow therapeutic window combined with high interindividual pharmacokinetic variability. Our aim was to evaluate the effect of clinical and genetic factors on ERL dosing in a pilot cohort of 37 HTx recipients.Methods: Variants in CYP3A5, CYP3A4, CYP2C8, POR, NR1I2, and ABCB1 were genotyped, and clinical data were retrieved from patient charts.Results: While ERL trough concentration (C0) was within the targeted range for most patients, over 30‐fold variability in the dose‐adjusted ERL C0 was observed. Regression analysis revealed a significant effect of the non‐functional CYP3A5*3 variant on the dose‐adjusted ERL C0 (p = 0.031). ERL dose requirement was 0.02 mg/kg/d higher in patients with CYP3A5*1/*3 genotype compared to patients with CYP3A5*3/*3 to reach the targeted C0 (p = 0.041). ERL therapy substantially improved estimated glomerular filtration rate (28.6 ± 6.6 mL/min/1.73 m2) in patients with baseline kidney dysfunction.Conclusion: Everolimus pharmacokinetics in HTx recipients is highly variable. Our preliminary data on patients on a CNI‐free therapy regimen suggest that CYP3A5 genetic variation may contribute to this variability.
- 23 November 2015
- Published by Wiley in Clinical Transplantation
- Vol. 29 (12) , 1213-1220
Influence of CYP3A5 genetic variation on everolimus maintenance dosing after cardiac transplantation
Background: Everolimus (ERL) has become an alternative to calcineurin inhibitors (CNIs) due to its renal‐sparing properties, especially in heart transplant (HTx) recipients with kidney dysfunction. However, ERL dosing is challenging due to its narrow therapeutic window combined with high interindividual pharmacokinetic variability. Our aim was to evaluate the effect of clinical and genetic factors on ERL dosing in a pilot cohort of 37 HTx recipients.Methods: Variants in CYP3A5, CYP3A4, CYP2C8, POR, NR1I2, and ABCB1 were genotyped, and clinical data were retrieved from patient charts.Results: While ERL trough concentration (C0) was within the targeted range for most patients, over 30‐fold variability in the dose‐adjusted ERL C0 was observed. Regression analysis revealed a significant effect of the non‐functional CYP3A5*3 variant on the dose‐adjusted ERL C0 (p = 0.031). ERL dose requirement was 0.02 mg/kg/d higher in patients with CYP3A5*1/*3 genotype compared to patients with CYP3A5*3/*3 to reach the targeted C0 (p = 0.041). ERL therapy substantially improved estimated glomerular filtration rate (28.6 ± 6.6 mL/min/1.73 m2) in patients with baseline kidney dysfunction.Conclusion: Everolimus pharmacokinetics in HTx recipients is highly variable. Our preliminary data on patients on a CNI‐free therapy regimen suggest that CYP3A5 genetic variation may contribute to this variability.
- Open Access
- 9 October 2015
- Published by Springer Nature in BMC Cardiovascular Disorders
- Vol. 15 (1) , 1-9
Performance of gene-expression profiling test score variability to predict future clinical events in heart transplant recipients
A single non-invasive gene expression profiling (GEP) test (AlloMap®) is often used to discriminate if a heart transplant recipient is at a low risk of acute cellular rejection at time of testing. In a randomized trial, use of the test (a GEP score from 0–40) has been shown to be non-inferior to a routine endomyocardial biopsy for surveillance after heart transplantation in selected low-risk patients with respect to clinical outcomes. Recently, it was suggested that the within-patient variability of consecutive GEP scores may be used to independently predict future clinical events; however, future studies were recommended. Here we performed an analysis of an independent patient population to determine the prognostic utility of within-patient variability of GEP scores in predicting future clinical events. We defined the GEP score variability as the standard deviation of four GEP scores collected ≥315 days post-transplantation. Of the 737 patients from the Cardiac Allograft Rejection Gene Expression Observational (CARGO) II trial, 36 were assigned to the composite event group (death, re-transplantation or graft failure ≥315 days post-transplantation and within 3 years of the final GEP test) and 55 were assigned to the control group (non-event patients). In this case-controlled study, the performance of GEP score variability to predict future events was evaluated by the area under the receiver operator characteristics curve (AUC ROC). The negative predictive values (NPV) and positive predictive values (PPV) including 95 % confidence intervals (CI) of GEP score variability were calculated. The estimated prevalence of events was 17 %. Events occurred at a median of 391 (inter-quartile range 376) days after the final GEP test. The GEP variability AUC ROC for the prediction of a composite event was 0.72 (95 % CI 0.6-0.8). The NPV for GEP score variability of 0.6 was 97 % (95 % CI 91.4-100.0); the PPV for GEP score variability of 1.5 was 35.4 % (95 % CI 13.5-75.8). In heart transplant recipients, a GEP score variability may be used to predict the probability that a composite event will occur within 3 years after the last GEP score. Clinicaltrials.gov identifier NCT00761787
- 9 October 2015
- Published by Springer Nature in BMC Cardiovascular Disorders
- Vol. 15 (1) , 1-9
Open AccessPerformance of gene-expression profiling test score variability to predict future clinical events in heart transplant recipients
A single non-invasive gene expression profiling (GEP) test (AlloMap®) is often used to discriminate if a heart transplant recipient is at a low risk of acute cellular rejection at time of testing. In a randomized trial, use of the test (a GEP score from 0–40) has been shown to be non-inferior to a routine endomyocardial biopsy for surveillance after heart transplantation in selected low-risk patients with respect to clinical outcomes. Recently, it was suggested that the within-patient variability of consecutive GEP scores may be used to independently predict future clinical events; however, future studies were recommended. Here we performed an analysis of an independent patient population to determine the prognostic utility of within-patient variability of GEP scores in predicting future clinical events. We defined the GEP score variability as the standard deviation of four GEP scores collected ≥315 days post-transplantation. Of the 737 patients from the Cardiac Allograft Rejection Gene Expression Observational (CARGO) II trial, 36 were assigned to the composite event group (death, re-transplantation or graft failure ≥315 days post-transplantation and within 3 years of the final GEP test) and 55 were assigned to the control group (non-event patients). In this case-controlled study, the performance of GEP score variability to predict future events was evaluated by the area under the receiver operator characteristics curve (AUC ROC). The negative predictive values (NPV) and positive predictive values (PPV) including 95 % confidence intervals (CI) of GEP score variability were calculated. The estimated prevalence of events was 17 %. Events occurred at a median of 391 (inter-quartile range 376) days after the final GEP test. The GEP variability AUC ROC for the prediction of a composite event was 0.72 (95 % CI 0.6-0.8). The NPV for GEP score variability of 0.6 was 97 % (95 % CI 91.4-100.0); the PPV for GEP score variability of 1.5 was 35.4 % (95 % CI 13.5-75.8). In heart transplant recipients, a GEP score variability may be used to predict the probability that a composite event will occur within 3 years after the last GEP score. Clinicaltrials.gov identifier NCT00761787
- Open Access
- 27 March 2015
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 47 (5) , 770-777
The European Registry for Patients with Mechanical Circulatory Support (EUROMACS): first annual report
The European Registry for Patients with Mechanical Circulatory Support (EUROMACS) was founded on 10 December 2009 with the initiative of Roland Hetzer (Deutsches Herzzentrum Berlin, Berlin, Germany) and Jan Gummert (Herz- und Diabeteszentrum Nordrhein-Westfalen, Bad Oeynhausen, Germany) with 15 other founding international members. It aims to promote scientific research to improve care of end-stage heart failure patients with ventricular assist device or a total artificial heart as long-term mechanical circulatory support. Likewise, the organization aims to provide and maintain a registry of device implantation data and long-term follow-up of patients with mechanical circulatory support. Hence, EUROMACS affiliated itself with Dendrite Clinical Systems Ltd to offer its members a software tool that allows input and analysis of patient clinical data on a daily basis. EUROMACS facilitates further scientific studies by offering research groups access to any available data wherein patients and centres are anonymized. Furthermore, EUROMACS aims to stimulate cooperation with clinical and research institutions and with peer associations involved to further its aims. EUROMACS is the only European-based Registry for Patients with Mechanical Circulatory Support with rapid increase in institutional and individual membership. Because of the expeditious data input, the European Association for Cardiothoracic Surgeons saw the need to optimize the data availability and the significance of the registry to improve care of patients with mechanical circulatory support and its potential contribution to scientific intents; hence, the beginning of their alliance in 2012. This first annual report is designed to provide an overview of EUROMACS' structure, its activities, a first data collection and an insight to its scientific contributions.
- 27 March 2015
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 47 (5) , 770-777
Open AccessThe European Registry for Patients with Mechanical Circulatory Support (EUROMACS): first annual report
The European Registry for Patients with Mechanical Circulatory Support (EUROMACS) was founded on 10 December 2009 with the initiative of Roland Hetzer (Deutsches Herzzentrum Berlin, Berlin, Germany) and Jan Gummert (Herz- und Diabeteszentrum Nordrhein-Westfalen, Bad Oeynhausen, Germany) with 15 other founding international members. It aims to promote scientific research to improve care of end-stage heart failure patients with ventricular assist device or a total artificial heart as long-term mechanical circulatory support. Likewise, the organization aims to provide and maintain a registry of device implantation data and long-term follow-up of patients with mechanical circulatory support. Hence, EUROMACS affiliated itself with Dendrite Clinical Systems Ltd to offer its members a software tool that allows input and analysis of patient clinical data on a daily basis. EUROMACS facilitates further scientific studies by offering research groups access to any available data wherein patients and centres are anonymized. Furthermore, EUROMACS aims to stimulate cooperation with clinical and research institutions and with peer associations involved to further its aims. EUROMACS is the only European-based Registry for Patients with Mechanical Circulatory Support with rapid increase in institutional and individual membership. Because of the expeditious data input, the European Association for Cardiothoracic Surgeons saw the need to optimize the data availability and the significance of the registry to improve care of patients with mechanical circulatory support and its potential contribution to scientific intents; hence, the beginning of their alliance in 2012. This first annual report is designed to provide an overview of EUROMACS' structure, its activities, a first data collection and an insight to its scientific contributions.
- 15 September 2014
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 46 (6) , 933-934
The CARMAT total artificial heart
- 15 September 2014
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 46 (6) , 933-934
The CARMAT total artificial heart
- Open Access
- 8 November 2012
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 42 (6) , 1047-1049
Editorial Comment: The clinical relevance of antibody-mediated rejection: a new era of heart transplantation
This issue reports a case where the authors can be congratulated on having saved the life of a patient who originally suffered from giant cell myocarditis and had been treated with cyclosporine (CyA), azathioprine (AZA) and corticosteroids (PDN) for 4 years before clinically deteriorating and been subjected to heart transplantation (HTx) [1]. The pretransplant work-up included human leukocyte antigen (HLA)-typing of both patient and donor, screening for anti-HLA antibodies and cross-match with regard to T- and B-cells being negative. Postoperatively, conventional immunosuppression (CyA, AZA and PDN) was introduced. There were three HLA Class I and one HLA Class II allele mismatches between donor and recipient.
- 8 November 2012
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 42 (6) , 1047-1049
Open AccessEditorial Comment: The clinical relevance of antibody-mediated rejection: a new era of heart transplantation
This issue reports a case where the authors can be congratulated on having saved the life of a patient who originally suffered from giant cell myocarditis and had been treated with cyclosporine (CyA), azathioprine (AZA) and corticosteroids (PDN) for 4 years before clinically deteriorating and been subjected to heart transplantation (HTx) [1]. The pretransplant work-up included human leukocyte antigen (HLA)-typing of both patient and donor, screening for anti-HLA antibodies and cross-match with regard to T- and B-cells being negative. Postoperatively, conventional immunosuppression (CyA, AZA and PDN) was introduced. There were three HLA Class I and one HLA Class II allele mismatches between donor and recipient.