Hasim Ustunsoy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hasim Ustunsoy has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Alptekin Yasim
Department of Cardiovascular Surgery, Faculty of Medicine, Kahramanmaraş Sütçü Imam University, Kahramanmaraş, Turkey
5 shared publications - Hayati Deniz
Gaziantep Ersin Arslan Education and Research Hospital, Department of Cardiovascular Surgery, Gaziantep,Turkey
5 shared publications - Gokhan Gokaslan
Department of Cardiovascular Surgery, Gaziantep Anka Hospital, Gaziantep 27590, Türkiye
3 shared publications Kemal Bakir
3 shared publications- Ozerdem Ozcaliskan
Medicalpark Hospital
3 shared publications - Gokalp Guzel
Department of Cardiovascular Surgery, Gaziantep University Medical Faculty, Gaziantep, Sehitkamil, 27310, Turkey
2 shared publications
Latest Publications
- 10 April 2014
- Published by Galenos Yayinevi in Turkish Journal of Thoracic and Cardiovascular Surgery
- Vol. 22 (2) , 320-326
Analysis of risk factors affecting mortality in proximal aortic surgery
Background: In this study, we aimed to investigate the incremental risk factors for mortality in patients undergoing proximal aortic surgery. Methods: Between January 2002 and June 2009, a total of 183 patients (116 males, 67 females, mean age: 59±14 years; range 23 to 82 years) were enrolled in this study. The preoperative risk factors were hypertension in 159 patients (86.8%), advanced age in 68 (37.1%), type 2 diabetes in 26 (14.2%), chronic obstructive pulmonary disease in 23 (%12.5), smoking in 106 (57.9%), nephropathy in 16 (8.7%), and cerebrovascular disease in 14 (7.6%). Except 79 patients with type A dissection who underwent surgery without coronary angiography, out of 104 patients with ascendant and arch aneurysm, 21 had coronary artery disease (20.1%). Seven patients (3.8%) previously underwent open heart surgery requiring sternotomy. The effects of the ascending aortic pathology, extent of the intervention to the pathological segment, cannulation techniques, methods of cerebral protection and the preoperative morbidity factors and the operative variables on the mortality and morbidity were assessed. Results: The in-hospital mortality rate was 15.3% in the overall group (20.2% in dissected patients and 11.5% in patients with an aneurysm). Multivariate regression analysis revealed that advanced age (4.31 times), chronic obstructive pulmonary disease (2 times), replacement extending to the arch (5.3 times), prolonged duration of cardiopulmonary bypass (4 times), preoperative hemodynamic instability (5.7 times), preoperative and postoperative nephropathy (1.6 and 2.4 times), central neuropathy (3.7 times), postoperative permanent neurological deficit (7.14 times), and vital organ malperfusion (12.5 times) increased the mortality. Conclusion: Proximal aortic surgery can be performed with acceptable mortality and morbidity rates. However, in this present study, we observed that preoperative or perioperative organ malperfusions significantly decreased the success of surgery in patients with type A aortic dissection requiring urgent surgery, in particular.
- 10 April 2014
- Published by Galenos Yayinevi in Turkish Journal of Thoracic and Cardiovascular Surgery
- Vol. 22 (2) , 320-326
Analysis of risk factors affecting mortality in proximal aortic surgery
Background: In this study, we aimed to investigate the incremental risk factors for mortality in patients undergoing proximal aortic surgery. Methods: Between January 2002 and June 2009, a total of 183 patients (116 males, 67 females, mean age: 59±14 years; range 23 to 82 years) were enrolled in this study. The preoperative risk factors were hypertension in 159 patients (86.8%), advanced age in 68 (37.1%), type 2 diabetes in 26 (14.2%), chronic obstructive pulmonary disease in 23 (%12.5), smoking in 106 (57.9%), nephropathy in 16 (8.7%), and cerebrovascular disease in 14 (7.6%). Except 79 patients with type A dissection who underwent surgery without coronary angiography, out of 104 patients with ascendant and arch aneurysm, 21 had coronary artery disease (20.1%). Seven patients (3.8%) previously underwent open heart surgery requiring sternotomy. The effects of the ascending aortic pathology, extent of the intervention to the pathological segment, cannulation techniques, methods of cerebral protection and the preoperative morbidity factors and the operative variables on the mortality and morbidity were assessed. Results: The in-hospital mortality rate was 15.3% in the overall group (20.2% in dissected patients and 11.5% in patients with an aneurysm). Multivariate regression analysis revealed that advanced age (4.31 times), chronic obstructive pulmonary disease (2 times), replacement extending to the arch (5.3 times), prolonged duration of cardiopulmonary bypass (4 times), preoperative hemodynamic instability (5.7 times), preoperative and postoperative nephropathy (1.6 and 2.4 times), central neuropathy (3.7 times), postoperative permanent neurological deficit (7.14 times), and vital organ malperfusion (12.5 times) increased the mortality. Conclusion: Proximal aortic surgery can be performed with acceptable mortality and morbidity rates. However, in this present study, we observed that preoperative or perioperative organ malperfusions significantly decreased the success of surgery in patients with type A aortic dissection requiring urgent surgery, in particular.
- 21 August 2013
- Published by Galenos Yayinevi in Turkish Journal of Thoracic and Cardiovascular Surgery
- Vol. 21 (3) , 628-632
Early- and mid-term results of off-pump pulmonary valve implantation: a single-center experience
- 21 August 2013
- Published by Galenos Yayinevi in Turkish Journal of Thoracic and Cardiovascular Surgery
- Vol. 21 (3) , 628-632
Early- and mid-term results of off-pump pulmonary valve implantation: a single-center experience
- Open Access
- 28 March 2013
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 8 (1) , 55
“V-PLASTY”: a novel technique to reconstruct pulmonary valvular and annular stenosis in patients with right ventricular outflow tract obstruction
The goal of repair of right ventricular outflow tract obstruction with or without Tetralogy of Fallot (TOF) is to eliminate valvular and/or subvalvular obstruction. However, this operation has a high risk of late complication of pulmonary insufficiency. In this study, we aimed to present early period results of our new technique that we call “V-Plasty” developed to prevent pulmonary insufficiency after pulmonary valve reconstruction in selected patients.
- 28 March 2013
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 8 (1) , 55
Open Access“V-PLASTY”: a novel technique to reconstruct pulmonary valvular and annular stenosis in patients with right ventricular outflow tract obstruction
The goal of repair of right ventricular outflow tract obstruction with or without Tetralogy of Fallot (TOF) is to eliminate valvular and/or subvalvular obstruction. However, this operation has a high risk of late complication of pulmonary insufficiency. In this study, we aimed to present early period results of our new technique that we call “V-Plasty” developed to prevent pulmonary insufficiency after pulmonary valve reconstruction in selected patients.
- 1 March 2013
- Vol. 22 (2) , 215-21
Short-term and mid-term results with the Sorin Freedom Solo aortic valve.
The study aim was to present the short- and mid-term results for patients who underwent aortic valve replacement (AVR) with the Sorin Freedom Solo third-generation stentless prosthetic valve. AVR with a Sorin Freedom Solo valve was performed in 14 patients between March 2006 and March 2011. Patients aged > or = 60 years (male:female ratio 6:8; mean age 73.28 +/- 5.42 years) who required AVR with the Sorin Freedom Solo valve according to the surgeon's choice were included in the study. The valvular prosthesis was implanted in the supra-annular position, using a single suture line. Eight patients underwent an isolated AVR; combined interventions were carried out in the other patients due to concomitant cardiac disease. One patient died during the immediate perioperative period, and two more during the follow up, from non-cardiac causes. The mean maximum transvalvular gradient of patients with aortic stenosis was 88.1 +/- 20.2 mmHg, and this fell to 26.4 +/- 7.6 mmHg during the early postoperative period. The mean gradient at one year of follow up was further decreased to 19.4 +/- 5.3 mmHg. The left ventricular end-diastolic and end-systolic diameters were also significantly reduced, from 4.8 +/- 0.9 to 4.3 +/- 0.6 cm and from 3.2 +/- 0.6 to 2.8 +/- 5.3 cm, respectively. The average left ventricular ejection fraction was 60.2 +/- 4.9% preoperatively, and 63.2 +/- 2.1% at one year after surgery (p = NS). No paravalvular leakage, endocarditis, prosthesis failure or neurologic events were reported among patients. The Sorin Freedom Solo stentless valve has provided good early and intermediate-term results. Implantation of the prosthesis is straightforward, with low rates of morbidity and mortality. However, these data require further support from larger patient series and long-term follow up.
- 1 March 2013
- Vol. 22 (2) , 215-21
Short-term and mid-term results with the Sorin Freedom Solo aortic valve.
The study aim was to present the short- and mid-term results for patients who underwent aortic valve replacement (AVR) with the Sorin Freedom Solo third-generation stentless prosthetic valve. AVR with a Sorin Freedom Solo valve was performed in 14 patients between March 2006 and March 2011. Patients aged > or = 60 years (male:female ratio 6:8; mean age 73.28 +/- 5.42 years) who required AVR with the Sorin Freedom Solo valve according to the surgeon's choice were included in the study. The valvular prosthesis was implanted in the supra-annular position, using a single suture line. Eight patients underwent an isolated AVR; combined interventions were carried out in the other patients due to concomitant cardiac disease. One patient died during the immediate perioperative period, and two more during the follow up, from non-cardiac causes. The mean maximum transvalvular gradient of patients with aortic stenosis was 88.1 +/- 20.2 mmHg, and this fell to 26.4 +/- 7.6 mmHg during the early postoperative period. The mean gradient at one year of follow up was further decreased to 19.4 +/- 5.3 mmHg. The left ventricular end-diastolic and end-systolic diameters were also significantly reduced, from 4.8 +/- 0.9 to 4.3 +/- 0.6 cm and from 3.2 +/- 0.6 to 2.8 +/- 5.3 cm, respectively. The average left ventricular ejection fraction was 60.2 +/- 4.9% preoperatively, and 63.2 +/- 2.1% at one year after surgery (p = NS). No paravalvular leakage, endocarditis, prosthesis failure or neurologic events were reported among patients. The Sorin Freedom Solo stentless valve has provided good early and intermediate-term results. Implantation of the prosthesis is straightforward, with low rates of morbidity and mortality. However, these data require further support from larger patient series and long-term follow up.
- 1 January 2013
- Published by Damar Cerrahi Dergisi - Turkish Journal of Vascular Surgery in Turkish Journal of Vascular Surgery
- Vol. 22 (1) , 76-79
Hybrid Approaches in the Treatment of Peripheral Arterial Disease
- 1 January 2013
- Published by Damar Cerrahi Dergisi - Turkish Journal of Vascular Surgery in Turkish Journal of Vascular Surgery
- Vol. 22 (1) , 76-79
Hybrid Approaches in the Treatment of Peripheral Arterial Disease
- Open Access
- 7 December 2012
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 7 (1) , 127
Urgent surgical management for embolized occluder devices in childhood: single center experience
In this study, we sought to analyze our experience in urgent surgical management for embolized cardiac septal and ductal occluder devices resulting from trans-catheter closure of atrial septal defect, ventricular septal defect and patent ductus arteriosus in childhood patient group.
- 7 December 2012
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 7 (1) , 127
Open AccessUrgent surgical management for embolized occluder devices in childhood: single center experience
In this study, we sought to analyze our experience in urgent surgical management for embolized cardiac septal and ductal occluder devices resulting from trans-catheter closure of atrial septal defect, ventricular septal defect and patent ductus arteriosus in childhood patient group.
- 29 October 2012
- Published by Galenos Yayinevi in Turkish Journal of Thoracic and Cardiovascular Surgery
- Vol. 20 (4) , 710-715
Midterm results of total correction surgery in tetralogy of Fallot
- 29 October 2012
- Published by Galenos Yayinevi in Turkish Journal of Thoracic and Cardiovascular Surgery
- Vol. 20 (4) , 710-715
Midterm results of total correction surgery in tetralogy of Fallot
- Open Access
- 11 July 2012
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 7 (1) , 67
Treatment outcomes of postoperative mediastinitis in cardiac surgery; negative pressure wound therapy versus conventional treatment
The aim of the present study is to compare negative pressure wound therapy versus conventional treatment outcomes at postoperative mediastinitis after cardiac surgery.
- 11 July 2012
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 7 (1) , 67
Open AccessTreatment outcomes of postoperative mediastinitis in cardiac surgery; negative pressure wound therapy versus conventional treatment
The aim of the present study is to compare negative pressure wound therapy versus conventional treatment outcomes at postoperative mediastinitis after cardiac surgery.
- 1 August 2009
- Published by IMR Press in The Heart Surgery Forum
- Vol. 12 (4) , E202-E207
Randomized Comparison of Vasodilator Effects of Iloprost versus Diltiazem on Flow and Pathologic Changes in Radial Arteries: Mid-term Angiographic Control Study of the Comparison of Vasodilators on Radial Artery Vasospasm
The increasing prevalence of routine radial artery (RA) use in coronary artery bypass grafting (CABG) has rendered the pharmacologic prevention of spasm of this artery a critical consideration in the early postoperative period and in the long-term outcome. In this study, we compared the effects of iloprost and diltiazem on vasospasm. Seventy patients who underwent CABG with the RA were randomized into 2 groups, and the vasodilator effects of iloprost and diltiazem were studied prospectively. RA flow was measured with Doppler ultrasonography. Following harvesting, a 5-mm piece was removed from the RA distally for pathologic examination. In group B, diltiazem was infused before removing the RA, whereas in group A, iloprost infusion was initiated 5 days before surgery. At the end of a 2-year follow-up, each patient underwent coronary angiography. Doppler flow measurements made during harvesting revealed a statistically significant reduction in flow, and a pathologic examination of the RAs revealed significant luminal narrowing in group B. A 2-year angiographic follow-up revealed all of the RA grafts in group A to be patent. Our evaluation of the results revealed the superior efficacy of iloprost over diltiazem in preventing RA spasm in the early period, and the 2-year angiographic findings showed that the use of iloprost produced superior mid-term patency.
- 1 August 2009
- Published by IMR Press in The Heart Surgery Forum
- Vol. 12 (4) , E202-E207
Randomized Comparison of Vasodilator Effects of Iloprost versus Diltiazem on Flow and Pathologic Changes in Radial Arteries: Mid-term Angiographic Control Study of the Comparison of Vasodilators on Radial Artery Vasospasm
The increasing prevalence of routine radial artery (RA) use in coronary artery bypass grafting (CABG) has rendered the pharmacologic prevention of spasm of this artery a critical consideration in the early postoperative period and in the long-term outcome. In this study, we compared the effects of iloprost and diltiazem on vasospasm. Seventy patients who underwent CABG with the RA were randomized into 2 groups, and the vasodilator effects of iloprost and diltiazem were studied prospectively. RA flow was measured with Doppler ultrasonography. Following harvesting, a 5-mm piece was removed from the RA distally for pathologic examination. In group B, diltiazem was infused before removing the RA, whereas in group A, iloprost infusion was initiated 5 days before surgery. At the end of a 2-year follow-up, each patient underwent coronary angiography. Doppler flow measurements made during harvesting revealed a statistically significant reduction in flow, and a pathologic examination of the RAs revealed significant luminal narrowing in group B. A 2-year angiographic follow-up revealed all of the RA grafts in group A to be patent. Our evaluation of the results revealed the superior efficacy of iloprost over diltiazem in preventing RA spasm in the early period, and the 2-year angiographic findings showed that the use of iloprost produced superior mid-term patency.