Hemant S. Thatte
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hemant S. Thatte has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
Shukri F. Khuri
VA Boston Healthcare Syst, Dept Cardiothorac Surg, Boston, MA USA
5 shared publicationsPatrick R. Treanor
VA Boston Healthcare System, Boston, Massachusetts
4 shared publicationsXiu-Gui Lu
Division Cardiothoracic Surgery, Department of Surgery, Harvard Medical School, Boston, Massachusetts; Department of Surgery, Brigham and Women׳s Hospital, Boston, Massachusetts; VA Boston Healthcare System, Boston, Massachusetts
4 shared publicationsBader E. Hussaini
Department of Cardiothoracic Surgery, VA Boston Healthcare System, Boston, Massachusetts, USA
3 shared publicationsNancy A. Healey
VA Boston Healthcare Syst, Dept Cardiothorac Surg, Boston, MA USA
2 shared publications- Bader E Hussaini
Harvard Medical School, Boston, MA, USA
1 shared publication
Latest Publications
- Open Access
- 1 October 2014
- Published by Elsevier in American Journal of Transplantation
- Vol. 14 (10) , 2253-2262
Subnormothermic Preservation in Somah: A Novel Approach for Enhanced Functional Resuscitation of Donor Hearts for Transplant
- 1 October 2014
- Published by Elsevier in American Journal of Transplantation
- Vol. 14 (10) , 2253-2262
Open AccessSubnormothermic Preservation in Somah: A Novel Approach for Enhanced Functional Resuscitation of Donor Hearts for Transplant
- Open Access
- 20 September 2014
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 9 (1) , 155
Cardioplegia at subnormothermia facilitates rapid functional resuscitation of hearts preserved in SOMAH for transplants
Hearts preserved ex vivo at 4°C undergo time-dependent irreversible injury due to extreme hypothermia. Studies using novel organ preservative solution SOMAH, suggest that hearts are optimally `preserved' at subnormothermic temperature of 21°C. Present study evaluates relative efficacy of SOMAH `cardioplegia' at 4 and 21°C in preservation of optimum heart function after in vitro storage at subnormothermia. Porcine hearts arrested with SOMAH cardioplegia at 4 or 21°C were stored in SOMAH for 5-hour at 21°C (n = 5). At the end of storage, the weight of hearts was recorded and biopsies taken for cardiac tissue high energy phosphate level measurements. The hearts were then attached to a reperfusion apparatus and biochemical parameters including cardiac enzyme release and myocardial oxygen consumption and lactate production were determined in perfusate samples at regular intervals during ex vivo perfusion experiment. Functional evaluation of the hearts intraoperatively and ex vivo was performed by 2D echocardiography using trans-esophageal echocardiography probe. Post-storage heart weights were unaltered in both groups, while available high-energy phosphates (HEP) were greater in the 21°C group. Upon ex vivo reperfusion, coronary flow was significantly greater (p < 0.05) in 21°C group. 2D echo revealed a greater cardiac output, fractional area change and ejection fraction in 21°C group that was not significantly different than the 4°C group. However, unlike 4°C hearts, 21°C hearts did not require inotropic intervention. Upon reperfusion, rate of cardiac enzyme release temporally resolved in 21°C group, but not in the 4°C group. 21°C working hearts maintained their energy state during the experimental duration but not the 4°C group; albeit, both groups demonstrated robust metabolism and function during this period. Rapid metabolic switch, increased synthesis of HEP, decreased injury and optimal function provides evidence that hearts arrested at 21°C remain viably and functionally superior to those arrested at 4°C when stored in SOMAH at ambient temperature pre-transplant. Cardioplegic arrest and preservation of hearts in SOMAH at ambient temperature efficiently conserves metabolism and function in in vitro porcine model of heart transplant.
- 20 September 2014
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 9 (1) , 155
Open AccessCardioplegia at subnormothermia facilitates rapid functional resuscitation of hearts preserved in SOMAH for transplants
Hearts preserved ex vivo at 4°C undergo time-dependent irreversible injury due to extreme hypothermia. Studies using novel organ preservative solution SOMAH, suggest that hearts are optimally `preserved' at subnormothermic temperature of 21°C. Present study evaluates relative efficacy of SOMAH `cardioplegia' at 4 and 21°C in preservation of optimum heart function after in vitro storage at subnormothermia. Porcine hearts arrested with SOMAH cardioplegia at 4 or 21°C were stored in SOMAH for 5-hour at 21°C (n = 5). At the end of storage, the weight of hearts was recorded and biopsies taken for cardiac tissue high energy phosphate level measurements. The hearts were then attached to a reperfusion apparatus and biochemical parameters including cardiac enzyme release and myocardial oxygen consumption and lactate production were determined in perfusate samples at regular intervals during ex vivo perfusion experiment. Functional evaluation of the hearts intraoperatively and ex vivo was performed by 2D echocardiography using trans-esophageal echocardiography probe. Post-storage heart weights were unaltered in both groups, while available high-energy phosphates (HEP) were greater in the 21°C group. Upon ex vivo reperfusion, coronary flow was significantly greater (p < 0.05) in 21°C group. 2D echo revealed a greater cardiac output, fractional area change and ejection fraction in 21°C group that was not significantly different than the 4°C group. However, unlike 4°C hearts, 21°C hearts did not require inotropic intervention. Upon reperfusion, rate of cardiac enzyme release temporally resolved in 21°C group, but not in the 4°C group. 21°C working hearts maintained their energy state during the experimental duration but not the 4°C group; albeit, both groups demonstrated robust metabolism and function during this period. Rapid metabolic switch, increased synthesis of HEP, decreased injury and optimal function provides evidence that hearts arrested at 21°C remain viably and functionally superior to those arrested at 4°C when stored in SOMAH at ambient temperature pre-transplant. Cardioplegic arrest and preservation of hearts in SOMAH at ambient temperature efficiently conserves metabolism and function in in vitro porcine model of heart transplant.
- 1 September 2014
- Published by Elsevier in The Journal of Heart and Lung Transplantation
- Vol. 33 (9) , 963-970
Sub-normothermic preservation of donor hearts for transplantation using a novel solution, Somah: A comparative pre-clinical study
- 1 September 2014
- Published by Elsevier in The Journal of Heart and Lung Transplantation
- Vol. 33 (9) , 963-970
Sub-normothermic preservation of donor hearts for transplantation using a novel solution, Somah: A comparative pre-clinical study
- Open Access
- 10 June 2011
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 6 (1) , 82
Evaluation of endoscopic vein extraction on structural and functional viability of saphenous vein endothelium
Objectives: Endothelial injury during harvest influences graft patency post CABG. We have previously shown that endoscopic harvest causes structural and functional damage to the saphenous vein (SV) endothelium. However, causes of such injury may depend on the extraction technique. In order to assess this supposition, we evaluated the effect of VirtuoSaph endoscopic SV harvesting technique (VsEVH) on structural and functional viability of SV endothelium using multiphoton imaging, biochemical and immunofluorescence assays. Methods: Nineteen patients scheduled for CABG were prospectively identified. Each underwent VsEVH for one portion and "No-touch" open SV harvesting (OSVH) for another portion of the SV. A two cm segment from each portion was immersed in GALA conduit preservation solution and transported overnight to our lab for processing. The segments were labeled with fluorescent markers to quantify cell viability, calcium mobilization and generation of nitric oxide. Morphology, expression, localization and stability of endothelial caveolin, eNOS, von Willebrand factor and cadherin were evaluated using immunofluorescence, Western blot and multiphoton microscopy (MPM). Results: Morphological, biochemical and immunofluorescence parameters of viability, structure and function were well preserved in VsEVH group as in OSVH group. However, tonic eNOS activity, agonist-dependent calcium mobilization and nitric oxide production were partially attenuated in the VsEVH group. Conclusions: This study indicates that VirtuoSaph endoscopic SV harvesting technique preserves the structural and functional viability of SV endothelium, but may differentially attenuate the vasomotor function of the saphenous vein graft. Ultramini- Endoscopic extraction preserved the structure and function, but attenuated the calcium mobilization and nitric oxide generation in human SV endothelium.
- 10 June 2011
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 6 (1) , 82
Open AccessEvaluation of endoscopic vein extraction on structural and functional viability of saphenous vein endothelium
Objectives: Endothelial injury during harvest influences graft patency post CABG. We have previously shown that endoscopic harvest causes structural and functional damage to the saphenous vein (SV) endothelium. However, causes of such injury may depend on the extraction technique. In order to assess this supposition, we evaluated the effect of VirtuoSaph endoscopic SV harvesting technique (VsEVH) on structural and functional viability of SV endothelium using multiphoton imaging, biochemical and immunofluorescence assays. Methods: Nineteen patients scheduled for CABG were prospectively identified. Each underwent VsEVH for one portion and "No-touch" open SV harvesting (OSVH) for another portion of the SV. A two cm segment from each portion was immersed in GALA conduit preservation solution and transported overnight to our lab for processing. The segments were labeled with fluorescent markers to quantify cell viability, calcium mobilization and generation of nitric oxide. Morphology, expression, localization and stability of endothelial caveolin, eNOS, von Willebrand factor and cadherin were evaluated using immunofluorescence, Western blot and multiphoton microscopy (MPM). Results: Morphological, biochemical and immunofluorescence parameters of viability, structure and function were well preserved in VsEVH group as in OSVH group. However, tonic eNOS activity, agonist-dependent calcium mobilization and nitric oxide production were partially attenuated in the VsEVH group. Conclusions: This study indicates that VirtuoSaph endoscopic SV harvesting technique preserves the structural and functional viability of SV endothelium, but may differentially attenuate the vasomotor function of the saphenous vein graft. Ultramini- Endoscopic extraction preserved the structure and function, but attenuated the calcium mobilization and nitric oxide generation in human SV endothelium.
- 1 June 2011
- Published by Elsevier in Journal of Surgical Research
- Vol. 168 (1) , e7-e15
Multifactorial Comparison of Modified and Conventional Perfusion Strategies in A Porcine Model of Cardiopulmonary Bypass
- 1 June 2011
- Published by Elsevier in Journal of Surgical Research
- Vol. 168 (1) , e7-e15
Multifactorial Comparison of Modified and Conventional Perfusion Strategies in A Porcine Model of Cardiopulmonary Bypass
- Open Access
- 27 October 2009
- Published by Wolters Kluwer Health in Circulation
- Vol. 120 (17) , 1704-1713
Development and Evaluation of a Novel Solution, Somah, for the Procurement and Preservation of Beating and Nonbeating Donor Hearts for Transplantation
Background—Injury to myocytes, endocardium, and the coronary endothelium during harvesting and storage can compromise outcomes after heart transplantation. Safeguarding of structure and function of cardiomyocytes and endothelium in donor hearts may lead to improved patient survival after transplantation. Information gained from porcine hearts stored in standard transplant solution was used to design a superior preservation solution that would optimally protect and maintain organs from beating heart and/or nonbeating heart donors during long-term storage.Methods and Results—Multiphoton microscopy was used to image deep within cardiac biopsies and coronary artery tissue harvested from porcine hearts obtained from beating heart and nonbeating heart donors for analysis of myocyte and endothelial cell structure and function. Cell structural integrity and viability, calcium mobilization, and nitric oxide generation were determined with fluorescence viability markers, immunofluorescence, and Western blots. During hypothermic storage in standard preservation solution, Celsior, myocyte, and endothelial viability was markedly attenuated in hearts obtained from beating heart donors. In contrast, hearts from beating and nonbeating heart donors stored in the newly formulated Somah solution demonstrated an increase in high-energy phosphate levels, protection of cardiac myocyte viability, mitochondrial membrane polarization, and structural proteins. Similarly, coronary artery endothelial organization and function, calcium mobilization, and nitric oxide generation were well maintained during temporal storage in Somah.Conclusions—The Celsior preservation solution in clinical use today has led to a profound decline in cardiomyocyte and endothelial cell viability, whereas the newly designed Somah solution has safeguarded myocyte and endothelial integrity and function during organ storage. Use of Somah as a storage medium may lead to optimized graft function and long-term patient survival after transplantation.
- 27 October 2009
- Published by Wolters Kluwer Health in Circulation
- Vol. 120 (17) , 1704-1713
Open AccessDevelopment and Evaluation of a Novel Solution, Somah, for the Procurement and Preservation of Beating and Nonbeating Donor Hearts for Transplantation
Background—Injury to myocytes, endocardium, and the coronary endothelium during harvesting and storage can compromise outcomes after heart transplantation. Safeguarding of structure and function of cardiomyocytes and endothelium in donor hearts may lead to improved patient survival after transplantation. Information gained from porcine hearts stored in standard transplant solution was used to design a superior preservation solution that would optimally protect and maintain organs from beating heart and/or nonbeating heart donors during long-term storage.Methods and Results—Multiphoton microscopy was used to image deep within cardiac biopsies and coronary artery tissue harvested from porcine hearts obtained from beating heart and nonbeating heart donors for analysis of myocyte and endothelial cell structure and function. Cell structural integrity and viability, calcium mobilization, and nitric oxide generation were determined with fluorescence viability markers, immunofluorescence, and Western blots. During hypothermic storage in standard preservation solution, Celsior, myocyte, and endothelial viability was markedly attenuated in hearts obtained from beating heart donors. In contrast, hearts from beating and nonbeating heart donors stored in the newly formulated Somah solution demonstrated an increase in high-energy phosphate levels, protection of cardiac myocyte viability, mitochondrial membrane polarization, and structural proteins. Similarly, coronary artery endothelial organization and function, calcium mobilization, and nitric oxide generation were well maintained during temporal storage in Somah.Conclusions—The Celsior preservation solution in clinical use today has led to a profound decline in cardiomyocyte and endothelial cell viability, whereas the newly designed Somah solution has safeguarded myocyte and endothelial integrity and function during organ storage. Use of Somah as a storage medium may lead to optimized graft function and long-term patient survival after transplantation.
- 1 September 2009
- Published by SAGE Publications in Perfusion
- Vol. 24 (5) , 317-323
Evaluation of blood components exposed to coated arterial filters in extracorporeal circuits
Background: Biocompatible surfaces play an important role in the inflammatory response during cardiopulmonary bypass (CBP), with the arterial filter contributing a large surface area of the circuit. Different filter-coating materials designed to improve blood-filter biocompatibility are currently used in CPB circuits. This study evaluates eight biocompatible coatings used for arterial filters and their effects on blood components during circulation. Methods: Arterial filters were randomly assigned in eight independent heparin-bonded tubing loops and perfused by a single swine (n=8). Arterial blood was routed simultaneously, but separately, into each circuit and circulated for 30 minutes at 37°C. Blood samples were drawn for CBC, ACT, and TAT III measurements at baseline, post-heparinization and post-circulation. At study completion, filters were imaged using multiphoton microscopy. Results: RBC, platelet, and WBC counts, and TAT III complex were all decreased after 30 minutes of circulation; however, WBC count was the only parameter that showed statistically significant differences between the filters. Circulating WBC reduction ranged from 6% (Carmeda and Trillium) to 41% (Terumo-X-coating) with corresponding microscopic confirmation of increased WBC entrapment. Conclusion: All eight filter coatings altered the blood components to varying degrees. Selection of the most effective filter, in conjunction with a heparin-bonded circuit for CPB, may decrease the intraoperative foreign-surface activation of blood cells.
- 1 September 2009
- Published by SAGE Publications in Perfusion
- Vol. 24 (5) , 317-323
Evaluation of blood components exposed to coated arterial filters in extracorporeal circuits
Background: Biocompatible surfaces play an important role in the inflammatory response during cardiopulmonary bypass (CBP), with the arterial filter contributing a large surface area of the circuit. Different filter-coating materials designed to improve blood-filter biocompatibility are currently used in CPB circuits. This study evaluates eight biocompatible coatings used for arterial filters and their effects on blood components during circulation. Methods: Arterial filters were randomly assigned in eight independent heparin-bonded tubing loops and perfused by a single swine (n=8). Arterial blood was routed simultaneously, but separately, into each circuit and circulated for 30 minutes at 37°C. Blood samples were drawn for CBC, ACT, and TAT III measurements at baseline, post-heparinization and post-circulation. At study completion, filters were imaged using multiphoton microscopy. Results: RBC, platelet, and WBC counts, and TAT III complex were all decreased after 30 minutes of circulation; however, WBC count was the only parameter that showed statistically significant differences between the filters. Circulating WBC reduction ranged from 6% (Carmeda and Trillium) to 41% (Terumo-X-coating) with corresponding microscopic confirmation of increased WBC entrapment. Conclusion: All eight filter coatings altered the blood components to varying degrees. Selection of the most effective filter, in conjunction with a heparin-bonded circuit for CPB, may decrease the intraoperative foreign-surface activation of blood cells.
- 28 February 2006
- Published by Elsevier in Journal of Surgical Research
- Vol. 130 (2) , 243
Intraoperative myocardial tissue acidosis encountered during cardiac surgery is reflective of myocardial tissue damage
- 28 February 2006
- Published by Elsevier in Journal of Surgical Research
- Vol. 130 (2) , 243
Intraoperative myocardial tissue acidosis encountered during cardiac surgery is reflective of myocardial tissue damage
- 1 July 2004
- Published by Wolters Kluwer Health in Journal of Trauma: Injury, Infection & Critical Care
- Vol. 57 (1) , S7-S12
Poly-N-Acetyl Glucosamine–Mediated Red Blood Cell Interactions
Investigations were performed to assess the effect of poly-N-acetyl glucosamine (p-GlcNAc) fiber slurry–mediated hemostasis by interactions with red blood cells. Red blood cell aggregation studies were performed using test material–coated microscope slides and multiphoton microscopic measurements. Enzymatic removal of red blood cell surface proteins was achieved using trypsin and neuraminidase treatment. Zeta-potential measurements (surface charge) were performed. Red blood cells interact directly with poly-N-acetyl glucosamine polymers through ionic interactions and cell-surface proteins. The effective concentration of poly-N-acetyl glucosamine fiber material for 50% red blood cell aggregation was 0.28 mg/mL. The p-GlcNAc beta-configuration fibers and an alpha-configuration structural modification of the fibers both produced maximal responses because of their zeta-potentials, whereas other chemically modified p-GlcNAcs and chitosans were ineffective. Poly-N-acetyl glucosamine–induced red blood cell aggregation is mediated by interactions with red blood cell surface charges.
- 1 July 2004
- Published by Wolters Kluwer Health in Journal of Trauma: Injury, Infection & Critical Care
- Vol. 57 (1) , S7-S12
Poly-N-Acetyl Glucosamine–Mediated Red Blood Cell Interactions
Investigations were performed to assess the effect of poly-N-acetyl glucosamine (p-GlcNAc) fiber slurry–mediated hemostasis by interactions with red blood cells. Red blood cell aggregation studies were performed using test material–coated microscope slides and multiphoton microscopic measurements. Enzymatic removal of red blood cell surface proteins was achieved using trypsin and neuraminidase treatment. Zeta-potential measurements (surface charge) were performed. Red blood cells interact directly with poly-N-acetyl glucosamine polymers through ionic interactions and cell-surface proteins. The effective concentration of poly-N-acetyl glucosamine fiber material for 50% red blood cell aggregation was 0.28 mg/mL. The p-GlcNAc beta-configuration fibers and an alpha-configuration structural modification of the fibers both produced maximal responses because of their zeta-potentials, whereas other chemically modified p-GlcNAcs and chitosans were ineffective. Poly-N-acetyl glucosamine–induced red blood cell aggregation is mediated by interactions with red blood cell surface charges.
- 1 December 2001
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 72 (6) , S2245-S2252
The coronary artery bypass conduit: I. Intraoperative endothelial injury and its implication on graft patency
- 1 December 2001
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 72 (6) , S2245-S2252
The coronary artery bypass conduit: I. Intraoperative endothelial injury and its implication on graft patency