CDChristos Dragoumanis

Christos Dragoumanis

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Christos Dragoumanis has a total of 34 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

    • 13 November 2013
      • Vol. 80  (3) , 287-8

    Oral fiberoptic intubation: the importance of the bevel orientation.

    by C Dragoumanis, I Pneumatikos

  • Open Access

    Relation of tricuspid annular displacement and tissue Doppler imaging velocities with duration of weaning in mechanically ventilated patients with acute pulmonary edema

    by Vasilios E Papaioannou, Dimitrios A Stakos, Christos K Dragoumanis, Ioannis A Pneumatikos

    Liberation from the ventilator is a difficult task, whereas early echocardiographic indices of weaning readiness are still lacking. The aim of this study was to test whether tricuspid annular plane systolic excursion (TAPSE) and right ventricular (RV) systolic (Sm) and diastolic (Em & Am) tissue Doppler imaging (TDI) velocities are related with duration of weaning in mechanically ventilated patients with acute respiratory failure due to acute pulmonary edema (APE). Detailed quantification of left and right ventricular systolic and diastolic function was performed at admission to the Intensive Care Unit by Doppler echocardiography, in a cohort of 32 mechanically ventilated patients with APE. TAPSE and RV TDI velocities were compared between patients with and without prolonged weaning (> or = or < 7 days from the first weaning trial respectively), whereas their association with duration of ventilation and left ventricular (LV) echo-derived indices was tested with multivariate linear and logistic regression analysis. Patients with prolonged weaning (n = 12) had decreased TAPSE (14.59 +/- 1.56 vs 19.13 +/- 2.59 mm), Sm (8.68 +/- 0.94 vs 11.62 +/- 1.77 cm/sec) and Em/Am ratio (0.98 +/- 0.80 vs 2.62 +/- 0.67, p or = 7 days. The above measures were also proven to correlate significantly with Epsilon/e' (r = -0.83 for TAPSE, r = -0.87 for Sm and r = -0.79 for Em/Am, p < 0.001 for all comparisons). We suggest that in mechanically ventilated patients with APE, low TAPSE and RV TDI velocities upon admission are associated with delayed liberation from mechanical ventilation, probably due to more severe LV heart failure.


    • 1 January 2009
      • Vol. 60  (4) , 221-8

    The impact of fluid restriction policy in reducing the use of red blood cells in cardiac surgery.

    by G Vretzakis, A Kleitsaki, K Stamoulis, C Dragoumanis, V Tasoudis, K Kyriakaki, D Mikroulis, A Giannoukas, N Tsilimingas

    Hemodilution contributes significantly to transfusion requirements in patients undergoing CABG under CPB. We hypothesised that restriction of parenteral fluids in comparison to a liberal fluid administration policy leads to less use of packed red cells in CABG operations supported by cell salvage. After consent and approval, 130 patients operated under equal conditions were assigned prospectively and randomly either for a restrictive protocol for intravenous fluid administration (group A, 65 pts) or not (group B, 65 pts). Transfusion guidelines were common for the two groups. The volumes of intravenous fluids, priming, "extra" volume on pump and cardioplegic solution and the volume of urine were recorded. Net erythrocyte volume loss was calculated. The number of the transfused PRC was analyzed as a continuous variable. "Transfusion" was analyzed as a categorical characteristic. Significant difference existed between groups for the fluids administered intravenously until the initiation of CPB and for fluid balance after CPB. Intraoperatively transfused units were significantly lower in A (0.32 +/- 0.77 vs 1.26 +/- 1.05 u/per pt; p<0.0001). Transfused patients were also significantly lower in A (11/65 vs 44/65; p<0.0001). In both groups, the values of hematocrit were statistically decreased. The greatest difference compared to the preoperative values was observed after CPB (from 40.8 +/- 4.2 to 21.9 +/- 3.6 for A, and from 40.2 +/- 3.7 to 19.7 +/- 3.3 for B ; p<0.0001 for both). For these lowest values, significant difference existed between groups (p<0,001) while the difference in the hematocrit values to the end of operation was insignificant. Transfusion in ICU showed no significant difference among groups. Hours of mechanical ventilation in ICU were ranging from 5 to 29 (mean = 10.0, median = 9) for A and from 5 to 42 (mean = 14.8, median = 10) for B. Length of stay in ICU in nights for group A was ranging from 1 to 10 (mean = 2.7, median = 2) and for group B was ranging from 1 to 6 (mean = 3.5, median = 2). In conclusion, reduction of transfusions in CABG operations is feasible when a restrictive protocol for intravenous fluids is applied.


  • Open Access

    Apneic oxygenation for elimination of respiratory motion artefact in an intubated patient undergoing helical chest computed tomography angiography.

    by Christos Konstantinos Dragoumanis, Vasilios E Papaioannou, Soultana Foutzitzi, Panagiotis Prassopoulos, Ioannis Pneumatikos

    Respiratory motion artifact in intubated and mechanically ventilated patients often reduces the quality of helical computed tomography pulmonary angiography (CTPA). Apneic oxygenation is a well established intra-operative technique that allows adequate oxygenation for short periods (up to 10 min) in sedated and paralyzed patients. We describe the use of the apneic oxygenation for elimination of respiratory motion artefact in an intubated patient undergoing helical chest computed tomography angiography.</p


  • Open Access

    A step-by-step diagnosis of exclusion in a twin pregnancy with acute respiratory failure due to non-fatal amniotic fluid embolism: a case report

    by Vasilios E. Papaioannou, Christos Dragoumanis, Vassiliki Theodorou, Dimitrios Konstantonis, Ioannis Pneumatikos

    Introduction: Respiratory failure may develop during the later stages of pregnancy and is usually associated with tocolysis or other co-existing conditions such as pneumonia, sepsis, pre-eclampsia or amniotic fluid embolism syndrome. Case presentation: We present the case of a 34-year-old healthy woman with a twin pregnancy at 31 weeks and 6 days who experienced acute respiratory failure, a few hours after administration of tocolysis (ritodrine), due to preterm premature rupture of the membranes. Her chest discomfort was significantly ameliorated after the ritodrine infusion was stopped and a Cesarean section was performed 48 hours later under spinal anesthesia; however, 2 hours after surgery she developed severe hypoxemia, hypotension, fever and mild coagulopathy. The patient was intubated and transferred to the intensive care unit where she made a quick and uneventful recovery within 3 days. As there was no evidence for drug- or infection-related thromboembolic or myocardial causes of respiratory failure, we conclude that our patient experienced a rare type of non-fatal amniotic fluid embolism. Conclusion: In spite of the lack of solid scientific support for our diagnosis, we conclude that our patient suffered an uncommon type of amniotic fluid embolism syndrome and we believe that this report highlights the need for extreme vigilance and a high index of suspicion for such a diagnosis in any pregnant individual.


    • 1 January 2008
      • Vol. 59  (2) , 79-86

    The propofol infusion 'syndrome' in intensive care unit: from pathophysiology to prophylaxis and treatment.

    by Vasilios Papaioannou, C Dragoumanis, V Theodorou, I Pneumatikos

    Propofol is a short-acting intravenous anesthetic agent widely used for sedation in anesthesia and intensive care. However, during the last 15 years there have been quite a lot of publications reporting unexplained deaths among pediatric and adult critically ill patients. These cases shared common symptoms and signs unrelated with initial admission diagnosis and were under long-term propofol infusion at high doses. A new syndrome called 'propofol infusion syndrome' was defined, including cardiovascular instability, metabolic acidosis, hyperkalaemia and rhabdomyolysis, with no evidence for other known causes of myocardial failure. One common denominator in these patients was the presence of hypoxia and tissue hypoperfusion. It seems that during states of increased metabolic demand, the reduced energy production related to an inhibitory propofol action at the level of mitochondrial oxidative phosphorylation and lipid metabolism may lead to the manifestation of the syndrome. Furthermore, cases of early toxicity due to failure in cellular energy production with development of lactic acidosis have been also described during anesthesia. For the above reasons, recommendations for the limitation of propofol use have been devised by various institutions, whereas physicians need to be cautious when using prolonged propofol sedation and alert for early signs of toxicity.


  • Open Access

    A fatal case of recurrent amiodarone-induced thyrotoxicosis after percutaneous tracheotomy: a case report

    by Vasilios Papaioannou, Irene Terzi, Christos Dragoumanis, Dimitrios Konstantonis, Vassiliki Theodorou, Ioannis Pneumatikos

    Background: Amiodarone is a widely used antiarrythmic drug, which may produce secondary effects on the thyroid. In 14–18% of amiodarone-treated patients, there is overt thyroid dysfunction, usually in the form of amiodarone-induced thyrotoxicosis, which can be difficult to manage with standard medical treatment.Case presentation: Presented is the case of a 65-year-old man, under chronic treatment of atrial fibrillation with amiodarone, who was admitted to the Intensive Care Unit with acute cardio-respiratory failure and fever. He was recently hospitalized with respiratory distress, attributed to amiodarone-induced pulmonary fibrosis. Clinical and laboratory investigation revealed thyrotoxicosis due to amiodarone treatment. He was begun on thionamide, prednisone and beta-blockers. After a short term improvement of his clinical status the patient underwent percutaneous tracheotomy due to weaning failure from mechanical ventilation, which led to the development of recurrent thyrotoxicosis, unresponsive to medical treatment. Finally, the patient developed multiple organ failure and died, seven days later.Conclusion: We suggest that percutaneous tracheotomy could precipitate a thyrotoxic crisis, particularly in non-euthyroid patients suffering from concurrent severe illness and should be performed only in parallel with emergency thyroid surgery, when indicated.


  • Investigating the Failure to Aspirate Subglottic Secretions with the Evac Endotracheal Tube

    by Christos K. Dragoumanis, George I. Vretzakis, Vassilios E. Papaioannou, Vassilios N. Didilis, Theodsia D. Vogiatzaki, Ioannis A. Pneumatikos

    Aspiration of subglottic secretions is a widely used intervention for prevention of ventilator-associated pneumonia. However, using the Hi-Lo Evac endotracheal tube (Hi-Lo Evac; Mallinckrodt; Athlone, Ireland) (Evac ETT), dysfunction of the suction lumen and subsequent failure to aspirate the subglottic secretions are common. Our objective in this study was to determine the causes of suction lumen dysfunction experienced with the Evac ETT. We studied 40 adult patients intubated with the Evac ETT. In all cases for which dysfunction of the suction lumen was observed, the subglottic suction port was examined visually using a flexible bronchoscope. Dysfunction of the suction lumen occurred in 19 of 40 patients (48%). In 17 of these (43%), it was attributed to blockage of the subglottic suction port by suctioned tracheal mucosa. Evacuation of subglottic secretions using the Evac ETT is often ineffective due to prolapse of tracheal mucosa into the subglottic suction port.


    • 1 January 2004
      • Vol. 55  (3) , 221-7

    Coronary sinus venoarterial CO2 difference in different hemodynamic states.

    by G Vretzakis, E Ferdi, B Papaziogas, C Dragoumanis, J Pneumatikos, I Tsangaris, K Tsakiridis, F Konstantinou

    Myocardial metabolic rate and coronary flow are closely related limiting thus the diagnostic value of coronary sinus saturation monitoring as an indicator of flow. Regional venoarterial CO2 gradient was found elevated during low flow in various clinical and experimental conditions, in animals and humans. This study was undertaken to examine the impact of the variations of cardiac mechanical work on veno-arterial CO2 content and partial pressure difference (deltaPCO2) of the coronary sinus blood. Twenty-seven patients of either sex (m/f = 21/6), undergoing coronary artery bypass grafting under extracorporeal circulation, were studied. Monitoring included a Swan-Ganz catheter and a coronary sinus line. The correct position of the late was verified by the waveform displayed in the monitor. Immediately after cannulae placement, a hemodynamic profile was obtained and simultaneous arterial and coronary sinus sampling for blood gas analysis was done in an ABL 720 (Radiometer Copenhagen) analyzer. A second collection of the same data was obtained five minutes later with the patients in a slight "head-down" position. Conditions for exclusion was intersample variation of hemoglobin's concentration greater than 15% and sodium ion concentration difference greater than 10% of the greater value. Arteriovenous oxygen partial pressure difference (deltaP(a-cs)O2), veno-arterial carbon dioxide partial pressure difference (deltaP(cs-a)CO2), O2 & CO2 content difference and heart's respiratory quotient were calculated and correlated to cardiac output (CO) and the other hemodynamic parameters. Statistical analysis employed t-paired test and linear regression. No ischemia was detected during sampling. "Head-down" position had a significant impact to all hemodynamic parameters except heart rate. In both data rows, although CO ranged widely and altered significantly, coronary sinus oxygen saturation and arteriovenous O2 content difference were stable and showed insignificant correlations to all the hemodynamic parameters that were studied. Carbon dioxide content difference (coronary sinus-arterial) showed a trending of decrease with higher flow. DeltaP(cs-a)CO2 appeared stable and independent of flow. Finally, respiratory quotient decreased significantly from 0.91 +/- 0.4 to 0.86 +/- 0.4 (mean +/- SD; p < 0.05). The heart's high basal oxygen consumption and the almost near hemoglobin's desaturation transcoronary extraction of oxygen limits the value of coronary sinus saturation monitoring as indicator of coronary flow. Heart's little extraction reserve is faced with coronary flow reserve. In the physiologic range and under the conditions of anesthesia, elevated CO2 production is accompanied with increased coronary flow. Under these circumstances, deltaP(cs-a)CO2 appears stable and is not suitable for clinical decisions concerning heart's coronary flow.