HIHideaki Imanaka

Hideaki Imanaka

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Hideaki Imanaka has a total of 44 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Changes in endotracheal tube cuff pressure in mechanically ventilated adult patients

    by Asuka Motoyama, Shota Asai, Hiroyuki Konami, Yuri Matsumoto, Takuyo Misumi, Hideaki Imanaka, Masaji Nishimura

    During mechanical ventilation, endotracheal tube cuff pressure should be maintained within proper range. We investigated the effect of frequent adjustment on cuff pressure in 27 mechanically ventilated patients. Cuff pressure was recorded every 2 h and was adjusted to 24 cmH2O each time. We found that cuff pressure was decreased by 4.9 ± 2.9 cmH2O from the target value. Cuff pressure decreased to less than 20 cmH2O in 45% of measurement occasions 2 h after adjusting it to 24 cmH2O.


  • Open Access

    Successful use of extracorporeal membrane oxygenation in the reversal of cardiorespiratory failure induced by atonic uterine bleeding: a case report

    by Taiga Itagaki, Mutsuo Onodera, Nao Okuda, Emiko Nakataki, Hideaki Imanaka, Masaji Nishimura

    Introduction: Although extracorporeal membrane oxygenation has made sufficient progress to be considered for the management of life-threatening cardiac and respiratory failure, the risk of hemorrhagic complications may outweigh the benefits for patients with bleeding tendencies. We report, to the best of our knowledge, the first case of successful treatment by extracorporeal membrane oxygenation, without any hemorrhagic complications, of postpartum cardiorespiratory failure after massive uterine bleeding. Case presentation: A 25-year-old Japanese woman experienced massive atonic bleeding after delivering her second baby. Recovery from hemorrhagic shock was managed by conservative treatments, but she developed decompensated heart failure and refractory hypoxia. Because we could not obtain hemodynamic stability and proper oxygenation even with high doses of catecholamines and maximal ventilator settings, we administered venoarterial extracorporeal membrane oxygenation, whereupon her hemodynamic status immediately stabilized. After 72 hours of support without major bleeding, extracorporeal membrane oxygenation was successfully withdrawn. Conclusion: Even in cases of obstetric bleeding, if clotting status is stringently monitored, extracorporeal membrane oxygenation can be considered as an ultimate means of life support.


  • Open Access

    Temperature of gas delivered from ventilators

    by Yusuke Chikata, Mutsuo Onodera, Hideaki Imanaka, Masaji Nishimura

    Background: Although heated humidifiers (HHs) are the most efficient humidifying device for mechanical ventilation, some HHs do not provide sufficient humidification when the inlet temperature to the water chamber is high. Because portable and home-care ventilators use turbines, blowers, pistons, or compressors to inhale in ambient air, they may have higher gas temperature than ventilators with piping systems. We carried out a bench study to investigate the temperature of gas delivered from portable and home-care ventilators, including the effects of distance from ventilator outlet, fraction of inspiratory oxygen (FIO2), and minute volume (MV). Methods: We evaluated five ventilators equipped with turbine, blower, piston, or compressor system. Ambient air temperature was adjusted to 24°C ± 0.5°C, and ventilation was set at FIO2 0.21, 0.6, and 1.0, at MV 5 and 10 L/min. We analyzed gas temperature at 0, 40, 80, and 120 cm from ventilator outlet and altered ventilator settings. Results: While temperature varied according to ventilators, the outlet gas temperature of ventilators became stable after, at the most, 5 h. Gas temperature was 34.3°C ± 3.9°C at the ventilator outlet, 29.5°C ± 2.2°C after 40 cm, 25.4°C ± 1.2°C after 80 cm and 25.1°C ± 1.2°C after 120 cm (P < 0.01). FIO2 and MV did not affect gas temperature. Conclusion: Gas delivered from portable and home-care ventilator was not too hot to induce heated humidifier malfunctioning. Gas soon declined when passing through the limb.


  • Sleep quality of mechanically ventilated patients sedated with dexmedetomidine

    by Jun Oto, Katsunori Yamamoto, Shigefumi Koike, Mutsuo Onodera, Hideaki Imanaka, Masaji Nishimura

    Dexmedetomidine is thought to activate an endogenous pathway that naturally promotes non-rapid eye movement (NREM) sleep. Dexmedetomidine may induce restorative sleep, that is, NREM stage 3 and 4 (slow wave sleep; SWS) or sleep continuity in mechanically ventilated patients. Few data have been published, however, on the sleep characteristics of mechanically ventilated patients during dexmedetomidine infusion. We recorded polysomnography (PSG) for 24 h in mechanically ventilated patients sedated with dexmedetomidine. Dexmedetomidine (0.2–0.7 μg/kg/h) was administered intravenously to maintain the Richmond Agitation–Sedation Scale between −1 and −4 only during the nighttime (9:00 p.m. to 6:00 a.m.). During the daytime, we interrupted the sedatives and analgesics unless the patient complained of discomfort. When this occurred midazolam or opioids were administered intermittently. Sleep stages and the frequency of arousal/awakening during the nighttime were analyzed using Rechtschaffen and Kales criteria. For the ten mechanically ventilated adult patients recruited into the study, the median total sleep time (TST) during the night was 4.7 h (IQR, 4.2–8.1 h), and 78 % of sleep occurred during the night (median 78 %, IQR: 69–88 %). Sleep architecture was exclusively NREM sleep stage 1 (median 28.9 % of TST) and stage 2 (median 71.2 % of TST). Neither SWS (median 0 % of TST) nor rapid eye movement (REM) sleep (median 0 % of TST) was observed. Median frequency of arousals/awakenings was 9.3/h (IQR, 3–19.5/h). In mechanically ventilated patients, nighttime infusion of dexmedetomidine preserved the day-night cycle of sleep but induced severely disturbed sleep architecture without evidence of SWS or REM sleep.


  • Open Access

    Change in Ratio of Observed-to-Expected Deaths in Pediatric Patients after Implementing a Closed Policy in an Adult ICU That Admits Children

    by Yoshitoyo Ueno, Hideaki Imanaka, Jun Oto, Masaji Nishimura

    Backgrounds. We examined the effect on the prognosis of critically ill pediatric patients after a closed ICU policy was implemented into an adult ICU that admitted children.Materials and Methods. We assessed the Pediatric Index of Mortality 2 (PIM2) score of pediatric patients (≤15 y.o.) admitted to the ICU from 2001 to 2009. In our teaching hospital, the department for intensive care was established in January 2004. Since then, for critical care patients, we have followed a closed ICU policy with full-time intensivists. We subsequently compared PIM2 scores and the ratio of observed-to-expected deaths (O/E ratio) for three three-year periods: 2001–2003 (before closed policy), 2004–2006, and 2007–2009.Results. Data was collected from 532 pediatric patients. While the PIM2 score statistically significantly increased from0.066±0.130for 2001–2003 to0.114±0.239for 2004–2006 and0.086±0.147for 2007–2009, the O/E ratio decreased from 1.49 for 2001–2003 to 0.82 for 2004–2006 and remained at 0.82 for 2007–2009.Conclusion. The O/E ratio for critically ill pediatric patients improved after the establishment of a closed policy in an adult ICU that admitted children.


  • A Bench Study of the Effects of Leak on Ventilator Performance During Noninvasive Ventilation

    by Yoshitoyo Ueno, Nobuto Nakanishi, Jun Oto, Hideaki Imanaka, Masaji Nishimura

    BACKGROUND: During noninvasive ventilation (NIV), leak around the mask may cause inadequate ventilatory support or patient-ventilator asynchrony such as auto-triggering. Some NIV ventilators may be better than others at compensating for leak. METHODS: We bench studied 3 NIV ventilators (Vision, Carina, and Trilogy100) and 2 ICU ventilators (Puritan Bennett 840 and Evita XL) to assess how they coped with 2 leak levels and zero leak during NIV. With a 2-bellows-in-a-box lung model we simulated spontaneous breathing with tidal volumes of 300 mL and 500 mL, at pressure support of 0 and 10 cm H 2 O and PEEP of 5 and 10 cm H 2 O. We affixed the airway opening of the lung model to the mouth of a mannequin head and secured a mask on the mannequin face. We created a medium leak and a large leak with different size holes, and measured PEEP in the presence of leak. We also measured the actual pressure-support values and calculated the deviations from the set pressure-support value and the pressure-time product (PTP) of the airway opening pressure below and above baseline. RESULTS: With the medium leak only the Vision and Carina maintained the set PEEP and pressure support. With the large leak the pressure support was decreased with all the tested ventilators. With the larger leak and pressure support of 10 cm H 2 O the PTP below baseline for triggering increased with 2 ventilators, and the PTP above baseline for supporting the patient's inspiratory effort decreased with all 5 ventilators. The larger tidal volume increased the PTP below baseline with all 5 ventilators and at all leak sizes. CONCLUSIONS: Some of the ventilators compensated for leak better than others. With the larger leak none of the ventilators maintained the set PEEP or pressure support.


  • Open Access

    Effects of Open Lung Approach Policy on Mechanical Ventilation Duration in Postoperative Patients with Chronic Thromboembolism with Pulmonary Hypertension: A Case-Matched Study

    by H. Imanaka, M. Takeuchi, K. Tachibana, K. Konishi, M. Nishimura

    Patients with chronic thromboembolism with pulmonary hypertension (CTEPH) often develop severe hypoxaemia after pulmonary thromboendarterectomy. There is reluctance to apply high positive end-expiratory pressure (PEEP) to those patients, whereas high PEEP is important for acute hypoxaemic respiratory failure due to alveolar collapse. Open lung approach (OLA) policy, a combination of recruitment manoeuvre and PEEP titration, may improve oxygenation and lung mechanics in acute hypoxaemic respiratory failure, but the effect of OLA on the outcome is unknown. We designed a case-matched, retrospective study to investigate whether OLA policy improved the outcome of postoperative patients with CTEPH. Among 113 postoperative patients with CTEPH, 40 were chosen before and after the introduction of an OLA policy to create 1:1 ratio of case-match according to gender, age and preoperative total pulmonary resistance index (conventional treatment group vs OLA group). In the OLA group, recruitment manoeuvre was applied and then PEEP was titrated to maintain oxygenation every 12 hours. Gas exchange and duration of mechanical ventilation were compared between the groups. The OLA group showed higher P a O 2 /FiO 2 ratio at 12 hours after the surgery than the conventional group (P=0.0021). In the OLA group, duration of mechanical ventilation was shorter than the conventional treatment group (median, 23.5 hours vs 43 hours, P=0.0064). The OLA group showed lower cardiac index, higher pulmonary artery pressure and higher total pulmonary resistance index after the surgery than the conventional group. The introduction of the OLA policy may have shortened mechanical ventilation duration despite what appeared to be less favorable early postoperative hemodynamics in patients after the surgery for CTEPH.


  • Open Access

    Chest computed tomography of a patient revealing severe hypoxia due to amniotic fluid embolism: a case report

    by Hideaki Imanaka, Bunji Takahara, Harutaka Yamaguchi, Emiko Nakataki, Akiko Mano, Daisuke Inui, Jun Oto, Masaji Nishimura

    Amniotic fluid embolism is one of the most severe complications in the peripartum period. Because its onset is abrupt and fulminant, it is unlikely that there will be time to examine the condition using thoracic computed tomography (CT). We report a case of life-threatening amniotic fluid embolism, where chest CT in the acute phase was obtained.