SMSteven J. Morgan

Steven J. Morgan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Steven J. Morgan has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Is immediate weight bearing safe for periprosthetic distal femur fractures treated by locked plating? A feasibility study in 52 consecutive patients

    by Wade R. Smith, Jason W. Stoneback, Steven J. Morgan, Philip F. Stahel

    Periprosthetic distal femur fractures associated with total knee replacement are increasing in incidence. We hypothesized that a standardized management protocol would result in few implant failures and a low rate of postoperative complications. Retrospective observational cohort study at an urban level 1 trauma center and academic level 2 trauma center. Consecutive patients with periprosthetic distal femur fractures and stable total knee arthroplasty were included between January 1, 2011 and December 31, 2014. Patients were managed by a standardized protocol of co-management by a hospitalist service, fracture fixation within 24 h of admission by less-invasive locked bridge plating, and immediate unrestricted postoperative weight bearing. The primary outcome measure was the rate of postoperative complications. Secondary outcome measures included time to surgery, intraoperative blood loss, duration of surgery, length of hospital stay, time to full weight bearing, and time to radiographic fracture healing. Fifty four fractures were treated in 52 patients. There were three implant failures, one deep infection, one nonunion and two patients with symptomatic malunion. One patient had knee pain due to patellar component instability associated with valgus alignment. There were ten thromboembolic complications despite consistent anticoagulation. Two patients died within 12 months of injury. Thirty-eight patients had returned to their pre-injury ambulation status at 1 year follow-up. A standardized approach of less-invasive locked plating fixation and immediate unrestricted weight bearing appears safe and feasible in the management of this vulnerable patient cohort. This is a retrospective observational study without a Trial registration number.


  • Open Access

    Safe surgical technique for associated acetabular fractures

    by Takashi Suzuki, Wade R Smith, Cyril Mauffrey, Steven J Morgan

    Associated acetabular fractures are challenging injuries to manage. The complex surgical approaches and the technical difficulty in achieving anatomical reduction imply that the learning curve to achieve high-quality care of patients with such challenging injuries is extremely steep. This first article in theJournal’s“Safe Surgical Technique” section presents the standard surgical care, in conjunction with intraoperative tips and tricks, for the safe management of all subgroups of associated acetabular fractures.


  • Open Access

    The dangers of damage control orthopedics: a case report of vascular injury after femoral fracture external fixation

    by Gregory R Staeheli, Michael R Fraser, Steven J Morgan

    Background: Placement of external fixation frames is an expedient and minimally invasive method of achieving bone and joint stability in the setting of severe trauma. Although anatomic safe zones are established for placement of external fixation pins, neurovascular structures may be at risk in the setting of severe trauma. Case report: We present a case of a 21-year-old female involved in a high speed motorcycle accident who sustained a Type IIIB open segmental femur fracture with significant thigh soft tissue injury. Damage control orthopedic principals were applied and a spanning external fixator placed for provisional femoral stabilization. Intraoperative vascular examination noted absent distal pulses, however an intraoperative angiogram showed arterial flow distal to the trifurcation. Immediately postoperatively the dorsalis pedis pulse was detected using Doppler ultrasound but was then non-detectable over the preceding 12-hours. Femoral artery CT angiogram revealed iatrogenic superficial femoral artery occlusion due to kinking of the artery around an external fixator pin. Although the pin causing occlusion was placed under direct visualization, the degree of soft tissue injury altered the appearance of the local anatomy. The pin was subsequently revised allowing the artery to travel in its anatomic position, restoring perfusion. Conclusion: This case highlights the dangers associated with damage control orthopedics, especially when severe trauma alters normal local anatomy. Careful assessment of external fixator pin placement is crucial to avoiding iatrogenic injury. We recommend a thorough vascular examination pre-operatively and prior to leaving the operating room, which allows any abnormalities to be further evaluated while the patient remains in a controlled environment. When an unrecognized iatrogenic injury occurs, serial postoperative neurovascular examinations allow early recognition and corrective actions.


  • Open Access

    Modality of wound closure after total knee replacement: are staples as safe as sutures? A retrospective study of 181 patients

    by Justin T Newman, Steven J Morgan, Gustavo V Resende, Allison E Williams, E Mark Hammerberg, Michael R Dayton

    Surgical site wound closure plays a vital role in post-operative success. This effect is magnified in regard to commonly performed elective procedures such as total knee arthroplasty. The use of either sutures or staples for skin re-approximation remains a contested subject, which may have a significant impact on both patient safety and surgical outcome. The literature remains divided on this topic.