DFDeivis Elton Schlickmann Frainer

Deivis Elton Schlickmann Frainer

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Deivis Elton Schlickmann Frainer has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Nutritional strategies of physically active subjects with muscle dysmorphia

    by Nadir Contesini, Fernando Adami, Márcia T Blake, Carlos Bm Monteiro, Luiz C Abreu, Vitor E Valenti, Fernando S Almeida, Alexandre P Luciano, Marco A Cardoso, Jucemar Benedet, et al.

    The aim of this study was to identify dietary strategies for physically active individuals with muscle dysmorphia based on a systematic literature review.


    • 1 December 2007
      • Vol. 57  (4) , 335-42

    [Standardization and reliability of anthropometric measurements for population surveys].

    by Deivis Elton Schlickmann Frainer, Fernando Adami, Francisco De Assis Guedes De Vasconcelos, Maria Alice Altenburg De Assis, Maria Cristina Marino Calvo, Raquel Kerpel

    In this paper we describe the standardization and reliability of anthropometric measurements carried out by five population survey anthropometrists. For the standardization of anthropometric measurement techniques, one expert anthropometrist conducted two theoretical and practical workshops, in September 2006 and March 2007, where the intra- and interobserver technical errors of measurement (TEMs) were assessed, respectively. For the intraobserver assessment of anthropometric measurements, we studied 121 schoolchildren on two different days. For interobserver assessment, we studied 22 schoolchildren that were measured, during the same period, once by each of the five anthropometrists and by an expert anthropometrist. For skinfold thickness, intraobserver TEMs in general were smaller than 1 mm; for circumferences, TEMs in general were smaller than 1 cm. For the subscapular, suprailiac and calf skinfolds, the intraobserver relative TEMs were greater than the acceptable limit for beginner anthropometrists. Intraobserver reliability for skinfold thickness was greater than 0.95 and for circumferences was greater than 0.99 in almost all cases. The results of interobserver TEMs and reliability were similar to intraobserver assessment. The anthropometrists performed better in the intraobserver relative TEMs because their values were smaller than the acceptable limit. We conclude that the anthropometrists showed a better performance after two assessments of the error of measurement. This suggests that the standardization process of anthropometric measurements was carried out with success.