Guigen Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Guigen Zhang has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Charles Keith
Department of Cellular Biology
2 shared publicationsFurqan Haq
Micro/Nano Bioengineering Lab, Department of Biological and Agricultural Engineering, University of Georgia, Athens, GA 30602, USA
2 shared publicationsAmit Gefen
1 shared publication- Euihyeon Kim
Department of Biomedical Engineering, Georgia Tech and Emory University, Atlanta, GA 30332-0535, USA
1 shared publication Evan Call
1 shared publicationJan Kottner
1 shared publication
Latest Publications
- Open Access
- 10 October 2007
- Published by Springer Nature in Journal of Biological Engineering
- Vol. 1 (1) , 5
Role of reaction kinetics and mass transport in glucose sensing with nanopillar array electrodes
The use of nanopillar array electrodes (NAEs) for biosensor applications was explored using a combined experimental and simulation approach to characterize the role of reaction kinetics and mass transport in glucose detection with NAEs. Thin gold electrodes with arrays of vertically standing gold nanopillars were fabricated and their amperometric current responses were measured under bare and functionalized conditions. Results show that the sensing performances of both the bare and functionalized NAEs were affected not only by the presence and variation of the nanoscale structures on the electrodes but also by the reaction kinetics and mass transport of the analyte species involved. These results will shed new light for enhancing the performance of nanostructure based biosensors.
- 10 October 2007
- Published by Springer Nature in Journal of Biological Engineering
- Vol. 1 (1) , 5
Open AccessRole of reaction kinetics and mass transport in glucose sensing with nanopillar array electrodes
The use of nanopillar array electrodes (NAEs) for biosensor applications was explored using a combined experimental and simulation approach to characterize the role of reaction kinetics and mass transport in glucose detection with NAEs. Thin gold electrodes with arrays of vertically standing gold nanopillars were fabricated and their amperometric current responses were measured under bare and functionalized conditions. Results show that the sensing performances of both the bare and functionalized NAEs were affected not only by the presence and variation of the nanoscale structures on the electrodes but also by the reaction kinetics and mass transport of the analyte species involved. These results will shed new light for enhancing the performance of nanostructure based biosensors.
- Open Access
- 1 March 2007
- Published by Taylor & Francis in International Journal of Nanomedicine
- Vol. 2 (1) , 107-115
Neurite development in PC12 cells cultured on nanopillars and nanopores with sizes comparable with fi lopodia
We investigated the effect ofnanoscale topography on neurite development in pheochromocytoma (PC12 cells) by culturing the cells on substrates having nanoscale pillars and pores with sizes comparable with filipodia. We found that cells on nanopillars and nanopores developed fewer and shorter neurites than cells on smooth substrates, and that cells on nanopores developed more and longer neurites than cells on nanopillars. These results suggest that PC12 cells were spatially aware of the difference in the nanoscale structures of the underlying substrates and responded differently in their neurite extension. This finding points to the possibility of using nanoscale topographic features to control neurite development in neurons.
- 1 March 2007
- Published by Taylor & Francis in International Journal of Nanomedicine
- Vol. 2 (1) , 107-115
Open AccessNeurite development in PC12 cells cultured on nanopillars and nanopores with sizes comparable with fi lopodia
We investigated the effect ofnanoscale topography on neurite development in pheochromocytoma (PC12 cells) by culturing the cells on substrates having nanoscale pillars and pores with sizes comparable with filipodia. We found that cells on nanopillars and nanopores developed fewer and shorter neurites than cells on smooth substrates, and that cells on nanopores developed more and longer neurites than cells on nanopillars. These results suggest that PC12 cells were spatially aware of the difference in the nanoscale structures of the underlying substrates and responded differently in their neurite extension. This finding points to the possibility of using nanoscale topographic features to control neurite development in neurons.
- 1 January 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 19300395,p. 367-370
Effect of Electrical Double Layer on the Performance of Nanometer Interdigitated Electrodes
To investigate the effect of electrical double layer (EDL) on the electrical current response of interdigitated electrodes (IDEs), we performed a finite element based computational simulation of the electrochemical kinetics and mass transport occurring at nano-scale IDEs. Results show the presence of the EDL affects the voltammetric response of nano-IDEs. This effect varies with the gap spacing in the IDEs, the charge valence of the reactant, and the concentration of supporting electrolyte due to the overlap of diffuse and diffusion layers as well as the overlap of the diffuse layers of the generator and collector.
- 1 January 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 19300395,p. 367-370
Effect of Electrical Double Layer on the Performance of Nanometer Interdigitated Electrodes
To investigate the effect of electrical double layer (EDL) on the electrical current response of interdigitated electrodes (IDEs), we performed a finite element based computational simulation of the electrochemical kinetics and mass transport occurring at nano-scale IDEs. Results show the presence of the EDL affects the voltammetric response of nano-IDEs. This effect varies with the gap spacing in the IDEs, the charge valence of the reactant, and the concentration of supporting electrolyte due to the overlap of diffuse and diffusion layers as well as the overlap of the diffuse layers of the generator and collector.
- 3 February 2006
- Published by Wiley in Biotechnology Progress
- Vol. 22 (1) , 133-140
Neurite Development in PC12 Cells on Flexible Micro-Textured Substrates under Cyclic Stretch
We investigated the combined effect of micro-texture and mechanical strain on neuronal cell development such as neurite length and neurite density in a rat pheochromocytoma cell line (PC12 cells). Cells were seeded on flexible silicone substrates with micro-texture or no texture (smooth) and cultured under static and dynamic conditions. In the static condition substrates were not stretched and in the dynamic conditions substrates were subjected to cyclic uniaxial stretching at three different strain levels of 4%, 8%, and 16% with each at three different strain rates at 0.1, 0.5, and 1.0 Hz. Results showed that of all cell cultures there was no significant difference in neurite development between cells on smooth and textured substrates, except in the static and 4% at 0.1 Hz conditions, where micro-texture induced significantly longer neurites. With both types of substrates, a lower mechanical condition (4% at 1.0 Hz or 16% at 0.1 Hz) resulted in more and longer neurites and lower cell density, and a higher mechanical condition (16% at 1.0 Hz) resulted in fewer and shorter neurites and lower cell density as compared to the static condition. These findings suggest that the effect of the micro-texture on neurite development is more prominent in low mechanical conditions than in high mechanical conditions and that the strain level and strain rate have an interrelated effect on neurite development: a higher strain level at a lower strain rate has a similar effect as a lower strain level at a higher strain rate in terms of promoting neurite development.
- 3 February 2006
- Published by Wiley in Biotechnology Progress
- Vol. 22 (1) , 133-140
Neurite Development in PC12 Cells on Flexible Micro-Textured Substrates under Cyclic Stretch
We investigated the combined effect of micro-texture and mechanical strain on neuronal cell development such as neurite length and neurite density in a rat pheochromocytoma cell line (PC12 cells). Cells were seeded on flexible silicone substrates with micro-texture or no texture (smooth) and cultured under static and dynamic conditions. In the static condition substrates were not stretched and in the dynamic conditions substrates were subjected to cyclic uniaxial stretching at three different strain levels of 4%, 8%, and 16% with each at three different strain rates at 0.1, 0.5, and 1.0 Hz. Results showed that of all cell cultures there was no significant difference in neurite development between cells on smooth and textured substrates, except in the static and 4% at 0.1 Hz conditions, where micro-texture induced significantly longer neurites. With both types of substrates, a lower mechanical condition (4% at 1.0 Hz or 16% at 0.1 Hz) resulted in more and longer neurites and lower cell density, and a higher mechanical condition (16% at 1.0 Hz) resulted in fewer and shorter neurites and lower cell density as compared to the static condition. These findings suggest that the effect of the micro-texture on neurite development is more prominent in low mechanical conditions than in high mechanical conditions and that the strain level and strain rate have an interrelated effect on neurite development: a higher strain level at a lower strain rate has a similar effect as a lower strain level at a higher strain rate in terms of promoting neurite development.
- Open Access
- 1 January 2006
- Published by Taylor & Francis in International Journal of Nanomedicine
- Vol. 1 (1) , 73-80
Nanopillar array structures for enhancing biosensing performance
Fabrication of metallic nanopillar array structures and their application as electrodes in electrochemical-based biosensors are discussed in this report. Vertically standing nanopillar array structures were fabricated using an electrodeposition technique and their electrochemical characteristics were evaluated. For possible use in biosensing applications, these standing nanopillars should have sufficient mechanical stability to sustain the capillary forces caused by the nanopillar-liquid interactions in aqueous environment and should provide increased signal response in an electrochemical process. Our results showed that the developed nanopillar arrays were mechanically stable in aqueous environments and the nanostructured electrodes exhibited increased electrochemical response compared with flat electrodes.
- 1 January 2006
- Published by Taylor & Francis in International Journal of Nanomedicine
- Vol. 1 (1) , 73-80
Open AccessNanopillar array structures for enhancing biosensing performance
Fabrication of metallic nanopillar array structures and their application as electrodes in electrochemical-based biosensors are discussed in this report. Vertically standing nanopillar array structures were fabricated using an electrodeposition technique and their electrochemical characteristics were evaluated. For possible use in biosensing applications, these standing nanopillars should have sufficient mechanical stability to sustain the capillary forces caused by the nanopillar-liquid interactions in aqueous environment and should provide increased signal response in an electrochemical process. Our results showed that the developed nanopillar arrays were mechanically stable in aqueous environments and the nanostructured electrodes exhibited increased electrochemical response compared with flat electrodes.
- 1 March 2005
- Vol. 5 (1) , 85-90
Evaluating the viscoelastic properties of biological tissues in a new way.
In this paper, a new method for evaluating the viscoelastic properties of biological tissues such as tendons and ligaments is presented. This method obtains the complex modulus of these tissues to characterize their viscoelastic properties. With this method, the stresses and strains measured in time are first transformed (using FFT), and the complex modulus is then obtained. The complex modulus contains sufficient information about the viscoelastic characteristics of the biological tissues. With this method, the mechanical properties of biological tissues can be measured without making apriori assumptions regarding their structures, and the measurements can be made in real time.
- 1 March 2005
- Vol. 5 (1) , 85-90
Evaluating the viscoelastic properties of biological tissues in a new way.
In this paper, a new method for evaluating the viscoelastic properties of biological tissues such as tendons and ligaments is presented. This method obtains the complex modulus of these tissues to characterize their viscoelastic properties. With this method, the stresses and strains measured in time are first transformed (using FFT), and the complex modulus is then obtained. The complex modulus contains sufficient information about the viscoelastic characteristics of the biological tissues. With this method, the mechanical properties of biological tissues can be measured without making apriori assumptions regarding their structures, and the measurements can be made in real time.
- 31 August 2004
- Published by Elsevier in Clinical Biomechanics
- Vol. 19 (7) , 746-750
Avoiding the material nonlinearity in an external fixation device
- 31 August 2004
- Published by Elsevier in Clinical Biomechanics
- Vol. 19 (7) , 746-750
Avoiding the material nonlinearity in an external fixation device
- Open Access
- 30 June 2004
- Published by Elsevier in Clinical Biomechanics
- Vol. 19 (5) , 513-518
Geometric and material nonlinearity in tensioned wires of an external fixator
- 30 June 2004
- Published by Elsevier in Clinical Biomechanics
- Vol. 19 (5) , 513-518
Open AccessGeometric and material nonlinearity in tensioned wires of an external fixator