SASivan Almosnino

Sivan Almosnino

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sivan Almosnino has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Reproducibility of isokinetic knee eccentric and concentric strength indices in asymptomatic young adults

    by Sivan Almosnino, Joan M. Stevenson, Davide D. Bardana, Elena D. Diaconescu, Zeevi Dvir


    • 20 June 2012
      • Vol. 48  (4) , 569-75

    Does choice of angular velocity affect pain level during isokinetic strength testing of knee osteoarthritis patients?

    by S Almosnino, S C E Brandon, E A Sled

    Thigh musculature strength assessment in individuals with knee osteoarthritis is routinely performed in rehabilitative settings. A factor that may influence results is pain experienced during testing. To assess whether pain experienced during isokinetic testing in individuals with knee osteoarthritis is dependent on the angular velocity prescribed. Experimental, repeated measures. University laboratory. Thirty-five individuals (19 women, 16 men) with tibiofemoral osteoarthritis. Participants performed three randomized sets of five maximal concentric extension-flexion repetitions at 60°/s, 90°/s and 120°/s. Pain intensity was measured immediately after the completion of each set. Strength outcomes for each set were the average peak moment. Across gender, pain level was not significantly affected by testing velocity (P=0.18, η(p)(2) =0.05). There was a trend of women reporting more pain than men across all testing velocities, however this comparison did not reach statistical significance (P=0.18, η(p)(2)=0.05). There was a significant main effect of testing velocity on strength, with the highest level attained at 60°/s. However, no difference in strength was noted when testing was performed at 90°/s or 120°/s. A large variation in pain scores within and across conditions and gender was noted, suggesting that at the current stage: 1) isokinetic angular velocity prescription be performed on an individual patient basis; and 2) improvements in the manner pain is recorded are needed in order to reduce the variations in pain scores. Individual prescription of angular velocity may be necessary for optimal strength output and reduction of pain during effort exertion in this patient population.


  • Differentiating between types and levels of isokinetic knee musculature efforts

    by Sivan Almosnino, Joan M. Stevenson, Andrew G. Day, Davide D. Bardana, Elena D. Diaconescu, Zeevi Dvir


  • Spectral analysis of knee isokinetic extension curves of osteoarthritic patients

    by Sivan Almosnino, Elizabeth A. Sled, Patrick A. Costigan, Alison Chalmers, Joan M. Stevenson

    Isokinetic assessment of knee extensors muscle group function in patients suffering from knee osteoarthritis has exclusively been achieved using time-domain based variables. While useful, these analyses do not quantify the conspicuously irregular moment-time pattern exhibited by the involved knee when compared to the contralateral knee. The purpose of this investigation was to assess whether the frequency content of the isokinetic curve can quantify this latter phenomenon. Thirty two patients with knee osteoarthritis participated in this study. Each participant performed 5 maximal concentric knee extensions bilaterally at 60°/s using an isokinetic dynamometer. For each time-domain extension curve, the power spectrum was calculated via Fast Fourier Transform and the maximum frequency content value contained within 99% of total signal power was extracted. Of the 32 participants, 26 exhibited higher frequency contents in the isokinetic curves obtained from their involved knee (p= 0.002, effect size =0.35). The results suggest that the frequency content of isokinetic moment-time curves may provide useful quantitative information regarding the smoothness of moment production, and as such, may be used in conjunction with traditional time-domain variables in the assessment of knee extensors function in patients suffering from knee osteoarthritis.

  • Open Access

    Between-day reliability of electromechanical delay of selected neck muscles during performance of maximal isometric efforts

    by Sivan Almosnino, Lucie Pelland, Samuel V Pedlow, Joan M Stevenson

    Background: The purpose of this study was to assess the between-day reliability of the electromechanical delay (EMD) of selected neck muscles during the performance of maximal isometric contractions in five different directions. Methods: Twenty-one physically active males participated in two testing sessions separated by seven to eight days. Using a custom-made fixed frame dynamometer, cervical force and surface electromyography (EMG) were recorded bilaterally from the splenius capitis, upper trapezius and sternocleidomastoid muscles during the performance of efforts in extension, flexion, left and right lateral bending, and protraction. The EMD was extracted using the Teager-Kaiser Energy Operator. Reliability indices calculated for each muscle in each testing direction were: the difference in scores between the two testing sessions and corresponding 95% confidence intervals, the standard error of measurement (SEM) and intra-class correlation coefficients (ICC). Results: EMD values showed no evidence of systematic difference between the two testing sessions across all muscles and testing directions. The SEM for extension, flexion and lateral bending efforts ranged between 2.5 ms to 4.8 ms, indicating a good level of measurement precision. For protraction, SEM values were higher and considered to be imprecise for research and clinical purposes. ICC values for all muscles across all testing directions ranged from 0.23 to 0.79. Conclusion: EMD of selected neck muscles can be measured with sufficient precision for the assessment of neck muscle function in an athletic population in the majority of directions tested.


  • Open Access

    The free moment in walking and its change with foot rotation angle

    by Sivan Almosnino, Tara Kajaks, Patrick A Costigan

    Background: This investigation characterized the time-history pattern of the free moment (FM) during walking and, additionally, assessed whether walking with either an internally or externally rotated foot position altered the FM's time-history. Methods: Force plate and foot kinematic data were acquired simultaneously for 11 healthy subjects (6 males, 5 females) while walking at their self-selected comfortable speed in 3 foot rotation conditions (normal, internal and external). The FM was calculated and normalized by the product of each participant's body weight and height prior to extraction of peak FM, occurrence of peak FM in stance and net relative impulse. Differences in these values across foot rotation conditions were assessed using separate one-way, repeated measures analysis of variance and subsequent pair-wise comparisons. Results: The average FM pattern during normal walking exhibits a biphasic shape: resisting inward rotation during approximately the first half of stance and outward rotation during the latter part of stance. While no differences in peak FM or net relative impulse were observed between the internal foot rotation condition and normal walking, the external foot rotation condition resulted in significantly greater peak FM and relative net impulse in comparison to normal walking. Conclusion: The differences in selected FM variables between normal walking and the external foot rotation condition are attributable to individual subject response to walking with an externally rotated foot. In this condition, some subjects displayed a FM pattern that was similar to that recorded during normal walking, while others displayed markedly larger FM patterns that are comparable in magnitude to those reported for running. The larger FM values in these latter subjects are speculated to be a result of excessive transverse plane body movements. Whilst further investigation is warranted regarding the FM time-history characteristics during walking, our results indicate that the FM may provide useful information in assessment of gait.