Heather Logan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Heather Logan has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
Bill Hodgetts
Speech Pathology and Audiology, University of Alberta, 2-16, Corbett Hall Edmonton; 116 St. and 85 Ave, Edmonton, AB, T6G 2 G4, Canada
3 shared publications- Hadi Seikaly
Division of Otolaryngology-Head and Neck Surgery, Department of Surgery, University of Alberta, Edmonton, Alberta, Canada
3 shared publications - Johan Wolfaardt
Division of Otolaryngology Head and Neck Surgery, Department of Surgery, Faculty of Medicine and Dentistry, University of Alberta, 16940-87 Avenue, Edmonton, Alberta, T5R 4H5, Canada
3 shared publications - Pierre Boulanger
Department of Computing Science, University of Alberta, Edmonton, AB T6G 2E8, Canada
3 shared publications
Latest Publications
- Open Access
- 1 January 2013
- Published by SAGE Publications in Journal of Otolaryngology - Head & Neck Surgery
- Vol. 42 (1) , 42
Exploratory benchtop study evaluating the use of surgical design and simulation in fibula free flap mandibular reconstruction
Background: Surgical design and simulation (SDS) is a useful tool to help surgeons visualize the anatomy of the patient and perform operative maneuvers on the computer before implementation in the operating room. While these technologies have many advantages, further evidence of their potential to improve outcomes is required. The present benchtop study was intended to identify if there is a difference in surgical outcome between free-hand surgery completed without virtual surgical planning (VSP) software and preoperatively planned surgery completed with the use of VSP software. Methods: Five surgeons participated in the study. In Session A, participants were asked to do a free-hand reconstruction of a 3d printed mandible with a defect using a 3d printed fibula. Four weeks later, in Session B, the participants were asked to do the same reconstruction, but in this case using a preoperatively digitally designed surgical plan. Digital registration computer software, hard tissue measures and duration of the task were used to compare the outcome of the benchtop reconstructions. Results: The study revealed that: (1) superimposed images produced in a computer aided design (CAD) software were effective in comparing pre and post-surgical outcomes, (2) there was a difference, based on hard tissue measures, in surgical outcome between the two scenarios and (3) there was no difference in the time it took to complete the sessions. Conclusion: The study revealed that the participants were more consistent in the preoperatively digitally planned surgery than they were in the free hand surgery.
- 1 January 2013
- Published by SAGE Publications in Journal of Otolaryngology - Head & Neck Surgery
- Vol. 42 (1) , 42
Open AccessExploratory benchtop study evaluating the use of surgical design and simulation in fibula free flap mandibular reconstruction
Background: Surgical design and simulation (SDS) is a useful tool to help surgeons visualize the anatomy of the patient and perform operative maneuvers on the computer before implementation in the operating room. While these technologies have many advantages, further evidence of their potential to improve outcomes is required. The present benchtop study was intended to identify if there is a difference in surgical outcome between free-hand surgery completed without virtual surgical planning (VSP) software and preoperatively planned surgery completed with the use of VSP software. Methods: Five surgeons participated in the study. In Session A, participants were asked to do a free-hand reconstruction of a 3d printed mandible with a defect using a 3d printed fibula. Four weeks later, in Session B, the participants were asked to do the same reconstruction, but in this case using a preoperatively digitally designed surgical plan. Digital registration computer software, hard tissue measures and duration of the task were used to compare the outcome of the benchtop reconstructions. Results: The study revealed that: (1) superimposed images produced in a computer aided design (CAD) software were effective in comparing pre and post-surgical outcomes, (2) there was a difference, based on hard tissue measures, in surgical outcome between the two scenarios and (3) there was no difference in the time it took to complete the sessions. Conclusion: The study revealed that the participants were more consistent in the preoperatively digitally planned surgery than they were in the free hand surgery.
- Open Access
- 1 January 2013
- Published by SAGE Publications in Journal of Otolaryngology - Head & Neck Surgery
- Vol. 42 (1) , 40
Pilot study: Evaluation of the use of the convergent interview technique in understanding the perception of surgical design and simulation
Background: It is important to understand the perceived value of surgical design and simulation (SDS) amongst surgeons, as this will influence its implementation in clinical settings. The purpose of the present study was to examine the application of the convergent interview technique in the field of surgical design and simulation and evaluate whether the technique would uncover new perceptions of virtual surgical planning (VSP) and medical models not discovered by other qualitative case-based techniques. Methods: Five surgeons were asked to participate in the study. Each participant was interviewed following the convergent interview technique. After each interview, the interviewer interpreted the information by seeking agreements and disagreements among the interviewees in order to understand the key concepts in the field of SDS. Results: Fifteen important issues were extracted from the convergent interviews. Conclusion: In general, the convergent interview was an effective technique in collecting information about the perception of clinicians. The study identified three areas where the technique could be improved upon for future studies in the SDS field.
- 1 January 2013
- Published by SAGE Publications in Journal of Otolaryngology - Head & Neck Surgery
- Vol. 42 (1) , 40
Open AccessPilot study: Evaluation of the use of the convergent interview technique in understanding the perception of surgical design and simulation
Background: It is important to understand the perceived value of surgical design and simulation (SDS) amongst surgeons, as this will influence its implementation in clinical settings. The purpose of the present study was to examine the application of the convergent interview technique in the field of surgical design and simulation and evaluate whether the technique would uncover new perceptions of virtual surgical planning (VSP) and medical models not discovered by other qualitative case-based techniques. Methods: Five surgeons were asked to participate in the study. Each participant was interviewed following the convergent interview technique. After each interview, the interviewer interpreted the information by seeking agreements and disagreements among the interviewees in order to understand the key concepts in the field of SDS. Results: Fifteen important issues were extracted from the convergent interviews. Conclusion: In general, the convergent interview was an effective technique in collecting information about the perception of clinicians. The study identified three areas where the technique could be improved upon for future studies in the SDS field.
- Open Access
- 1 January 2013
- Published by SAGE Publications in Journal of Otolaryngology - Head & Neck Surgery
- Vol. 42 (1) , 25
Evaluation of the accuracy of Cone Beam Computerized Tomography (CBCT): Medical imaging technology in head and neck reconstruction
Background: With the introduction, development and commercialization of Cone Beam Computerized Tomography (CBCT) technologies in the field of head and neck reconstruction, clinicians now have increased access to the technology. Given the growth of this new user group, there is an increasing concern regarding proper use, understanding, quality and patient safety. Methods: The present study was carried out to evaluate data acquisition of CBCT medical imaging technology and the accuracy of the scanning at three different machine warming times. The study also compared the accuracy of CBCT at 0.2 mm slice thickness and Computerized Tomography (CT) at 1 mm slice thickness. A control model was CT scanned at five random intervals, at 1 mm slice thickness and CBCT scanned at specialized intervals, at 0.2 mm slice thickness. The data was then converted and imported into a software program where a digital registration procedure was used to compare the average deviations of the scanned models to the control. Results: The study found that there was no statistically significant difference amongst the three CBCT machine warming times. There was a statistically significant difference between CT scanning with 1 mm slice thickness and CBCT scanning with 0.2 mm slice thickness. Conclusions: The accuracy of the i-CAT CBCT scans used in the present study with a parameter at voxel size 0.2, will remain consistent and reliable at any warming stage. Also the difference between the CBCT i-CAT scans and the CT scans was not clinically significant based on suggested requirements of clinicians in head and neck reconstruction.
- 1 January 2013
- Published by SAGE Publications in Journal of Otolaryngology - Head & Neck Surgery
- Vol. 42 (1) , 25
Open AccessEvaluation of the accuracy of Cone Beam Computerized Tomography (CBCT): Medical imaging technology in head and neck reconstruction
Background: With the introduction, development and commercialization of Cone Beam Computerized Tomography (CBCT) technologies in the field of head and neck reconstruction, clinicians now have increased access to the technology. Given the growth of this new user group, there is an increasing concern regarding proper use, understanding, quality and patient safety. Methods: The present study was carried out to evaluate data acquisition of CBCT medical imaging technology and the accuracy of the scanning at three different machine warming times. The study also compared the accuracy of CBCT at 0.2 mm slice thickness and Computerized Tomography (CT) at 1 mm slice thickness. A control model was CT scanned at five random intervals, at 1 mm slice thickness and CBCT scanned at specialized intervals, at 0.2 mm slice thickness. The data was then converted and imported into a software program where a digital registration procedure was used to compare the average deviations of the scanned models to the control. Results: The study found that there was no statistically significant difference amongst the three CBCT machine warming times. There was a statistically significant difference between CT scanning with 1 mm slice thickness and CBCT scanning with 0.2 mm slice thickness. Conclusions: The accuracy of the i-CAT CBCT scans used in the present study with a parameter at voxel size 0.2, will remain consistent and reliable at any warming stage. Also the difference between the CBCT i-CAT scans and the CT scans was not clinically significant based on suggested requirements of clinicians in head and neck reconstruction.