LBLuke A. Bisby

Luke A. Bisby

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Luke A. Bisby has a total of 29 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Comparative Study of Strain Measurement Techniques for Assessing Creep in CFRP Tendons

    by Alexandra Boloux, Iurii Burda, Luke A. Bisby, Giovanni Pietro Terrasi

    The long-term viscoelastic behaviour of epoxy matrices in Carbon Fibre-Reinforced Polymer (CFRP) tendons can lead to creep strains which must be accurately quantified to improve the current necessarily conservative design guidelines for bridge applications. However, the task of experimentally capturing such strains—typically in the range of 0.05%—requires sensors with reliable long-term accuracy and precision. This study investigates creep in CFRP tendons subjected to sustained tensile loading at 80% (for 7 days) and 88% (for 22 h) of their ultimate tensile strength. Four strain sensing techniques were employed to capture the creep strains of the CFRP tendons: bonded metal foil strain gauges, a contact extensometer, Digital Image Correlation, and distributed fibre optic strain sensing. This work precisely quantifies—for the first time in CFRP creep testing—the influence of experimental artefacts on the performance of the strain sensors, including test rig movement, temperature sensitivity, and localised surface inhomogeneities. Results reveal significant measurement distortions: the extensometer recorded strain increases of 250% during tendon slip, while distributed fibre optics detected localised strain peaks reaching 150% of the surface average. These findings demonstrate that sensor-induced noise can substantially contaminate creep strain data, underscoring the critical need for rigorous experimental protocols and thorough sensor validation in CFRP creep studies.


  • Open Access

    Fretting Fatigue Performance of Unidirectional, Laminated Carbon Fibre Reinforced Polymer Straps at Elevated Service Temperature

    by Danijela Stankovic, Luke A. Bisby, Zafiris Triantafyllidis, Giovanni P. Terrasi

    The fretting fatigue performance of laminated, unidirectional (UD), pin-loaded, carbon fibre-reinforced polymer (CFRP) straps that can be used as bridge hanger cables was investigated at a sustained service temperature of 60 °C. The aim of this paper is to elucidate the influence of the slightly elevated service temperature on the tensile fatigue performance of CFRP straps. First, steady state thermal tests at ambient temperature and at 60 °C are presented, in order to establish the behaviour of the straps at these temperatures. These results indicated that the static tensile performance of the straps is not affected by the increase in temperature. Subsequently, nine upper stress levels (USLs) between 650 and 1400 MPa were chosen in order to establish the S–N curve at 60 °C (frequency 10 Hz; R = 0.1) and a comparison with an existing S–N curve at ambient temperature was made. In general, the straps fatigue limit was slightly decreased by temperature, up to 750 MPa USL, while, for the higher USLs, the straps performed slightly better as compared with the S–N curve at ambient temperature.


  • Open Access

    Influence of Temperature on the Mechanical Performance of Unidirectional Carbon Fiber Reinforced Polymer Straps

    by Danijela Stankovic, Luke A. Bisby, Giovanni P. Terrasi

    The performance of pretensioned, laminated, unidirectional (UD), carbon fiber reinforced polymer (CFRP) straps, that can potentially be used for example as bridge deck suspender cables or prestressed shear reinforcements for reinforced concrete slabs and beams, was investigated at elevated temperatures. This paper aims to elucidate the effects of elevated temperature specifically on the tensile performance of pretensioned, pin-loaded straps. Two types of tests are presented: (1) steady state thermal and (2) transient state thermal. Eight steady-state target temperatures in the range of 24 °C to 600 °C were chosen, based on results from dynamic mechanical thermal analysis (DMTA) and thermogravimetric analysis (TGA). Transient state thermal tests were performed at three sustained tensile load levels, namely 10, 15, and 20 kN, corresponding to 25%, 37%, and 50% of the ultimate tensile strength of the pin-loaded straps at ambient temperature. In general, the straps were able to retain about 50% of their ambient temperature ultimate tensile strength (UTS) at 365 °C.


  • Open Access

    Concrete confinement with TRM versus FRP jackets at elevated temperatures

    by G. Cerniauskas, Z. Tetta, D. A. Bournas, L. A. Bisby

    Despite the clear cost, ease of installation, and construction schedule advantages of confinement of concrete structural elements with fibre-reinforced polymers (FRPs) for strength and deformability enhancement, concerns as to their performance at elevated temperature, or in fire, remain. The results of a series of elevated temperature experiments on FRP and textile reinforced mortar (TRM) strengthening systems for confinement of circular concrete columns are presented. The behaviour and effectiveness of the respective confining systems is studied up to temperatures of 400 °C. A total of 24 concrete cylinders were wrapped in the hoop direction with different amounts of FRP or TRM, heated to steady-state temperatures between 20 and 400 °C, and loaded to failure in concentric axial compression under a steady-state thermal regime. The results indicate that the effectiveness of the FRP confining system bonded with epoxy decreased considerably, but did not vanish, with increasing temperatures, in particular within the region of the glass transition temperature of the epoxy resin/adhesive. Conversely, the TRM confining system, bonded with inorganic mortar rather than epoxy, demonstrated superior performance than the FRP confining system at 400 °C as compared against tests performed at ambient temperature.


  • Open Access

    Transient Thermal Tensile Behaviour of Novel Pitch-Based Ultra-High Modulus CFRP Tendons

    by Giovanni Pietro Terrasi, Emma R. E. McIntyre, Luke A. Bisby, Tobias D. Lämmlein, Pietro Lura

    A novel ultra-high modulus carbon fibre reinforced polymer (CFRP) prestressing tendon made from coal tar pitch-based carbon fibres was characterized in terms of high temperature tensile strength (up to 570 °C) with a series of transient thermal and steady state temperature tensile tests. Digital image correlation was used to capture the high temperature strain development during thermal and mechanical loading. Complementary thermogravimetric (TGA) and dynamic mechanical thermal (DMTA) experiments were performed on the tendons to elucidate their high temperature thermal and mechanical behaviour. The novel CFRP tendons investigated in the present study showed an ambient temperature design tensile strength of 1400 MPa. Their failure temperature at a sustained prestress level of 50% of the design tensile strength was 409 °C, which is higher than the failure temperature of most fibre reinforced polymer rebars used in civil engineering applications at similar utilisation levels. This high-temperature tensile strength shows that there is potential to use the novel high modulus CFRP tendons in CFRP pretensioned concrete elements for building applications that fulfill the fire resistance criteria typically applied within the construction industry.


  • A Review of Sociological Issues in Fire Safety Regulation

    by Graham Spinardi, Luke Bisby, Jose Torero


  • Special Issue on Timber in Fire

    by Luke A. Bisby, Andrea Frangi


  • Predictive testing for heat-induced spalling of concrete

    by Ieuan Rickard, Cristián Maluk, Luke Bisby, Susan Deeny

    This paper describes a project which sets out to define a practical predictive test method for heat-induced explosive spalling of concrete. The method is based on a novel testing apparatus known as the Heat-Transfer Rate Inducing System (H-TRIS), previously developed at The University of Edinburgh. A series of 75 samples were tested using a large-scale standard fire testing furnace at CERIB (France) and using H-TRIS in Edinburgh. Within the scope of this project, a thorough examination of the thermal exposure was carried out in order to ensure repeatability of the thermal exposure imposed during testing. The H-TRIS method and apparatus was successful in accurately replicating the thermal exposures experienced by samples in the fire testing furnace when testing to both the ISO 834 and modified hydrocarbon (HCM) standard fire curves. The testing has also provided insights into the influence of sample size, polypropylene fibre content, and moisture content on the propensity for heat-induced concrete spalling.


  • Open Access

    A contemporary review of large-scale non-standard structural fire testing

    by Luke Bisby, John Gales, Cristián Maluk


  • Fire Behavior of Thin CFRP Pretensioned High-Strength Concrete Slabs

    by Giovanni Pietro Terrasi, Luke Bisby, Michel Barbezat, Christian Affolter, Erich Hugi

    More sustainable precast concrete structural elements are emerging from the research community utilizing high-strength, self-consolidating fiber-reinforced concrete (HPSCC) reinforced with noncorroding prestressed carbon-fiber-reinforced polymer (CFRP). An example of this is a new type of precast CFRP pretensioned HPSCC panel intended as load-bearing beams or columns for use in building envelopes. Such elements have recently been applied to architectural façade elements in Europe. A key issue in the implementation of these elements as load-carrying members in buildings is demonstrating satisfactory performance in fire. It is well known that the bond between FRP reinforcing bars and concrete deteriorates at elevated temperatures. It is also known that high-strength concrete is susceptible to explosive spalling when subjected to fire. Reductions in FRP reinforcement tensile and bond strength during fire, effects on the load-bearing capacity of prestressed concrete structures, and the explosive spall...