Eric Meaudre
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Eric Meaudre has a total of 87 co-authors. Here are the top co-authors by number of shared publications:
B. Palmier
8 shared publicationsE. Cantais
5 shared publications- Julien Bordes
Department of Anesthesia and intensive care, Sainte Anne Military Teaching Hospital, Toulon, France
5 shared publications - Philippe Goutorbe
Department of intensive care, military teaching hospital, hôpital d'instruction des armées Sainte-Anne, boulevard Sainte-Anne, BP 20545, 83041 Toulon cedex 9, France
5 shared publications E. Kaiser
4 shared publicationsP. Goutorbe
4 shared publications
Latest Publications
- 1 December 2017
- Published by Elsevier in Journal de Chirurgie Viscérale
- Vol. 154, S18-S29
Damage control : concept et déclinaisons
- 1 December 2017
- Published by Elsevier in Journal de Chirurgie Viscérale
- Vol. 154, S18-S29
Damage control : concept et déclinaisons
- 1 September 2017
- Published by Elsevier in La Presse Médicale
- Vol. 46 (9) , 869-871
Abcès épidural à Staphylococcus aureus après pose d’un cathéter péridural chez un patient atteint de psoriasis
- 1 September 2017
- Published by Elsevier in La Presse Médicale
- Vol. 46 (9) , 869-871
Abcès épidural à Staphylococcus aureus après pose d’un cathéter péridural chez un patient atteint de psoriasis
- 21 November 2014
- Vol. 81 (8) , 876-84
Assessment of cerebral oxygenation in neurocritical care patients: comparison of a new four wavelengths forehead regional saturation in oxygen sensor (EQUANOX®) with brain tissue oxygenation. A prospective observational study.
Because of restricted information given by monitoring solely intracranial pressure and cerebral perfusion pressure, assessment of the cerebral oxygenation in neurocritical care patients would be of interest. The aim of this study was to determinate the correlation between the non-invasive measure regional saturation in oxygen (rSO2) with a third generation NIRS monitor and an invasive measure of brain tissue oxygenation tension (PbtO2). We conducted a prospective, observational, unblinded study including neurocritical care patients requiring a PbtO2 monitoring. Concomitant measurements of rSO2 were performed with a four wavelengths forehead sensor (EQUANOX Advance®) of the EQUANOX® 7600 System. We determined the correlation between rSO2 and PbtO2 and the ability of the rSO2 to detect ischemic episodes defined by a PbtO2 less than 15 mmHg. The rSO2 ischemic threshold was 60%. During 2 months, 8 consecutives patients, including 275 measurements, were studied. There was no correlation between rSO2 and PbtO2 (r=0.016 [-0.103-0.134], r2=0.0003, P=0.8). On the 86 ischemic episodes detected by PbtO2, only 13 were also detected by rSO2. ROC curve showed the inability for rSO2 to detect cerebral hypoxia episodes (AUC=0.54). rSO2 cannot be used as a substitute for PbtO2 to monitor cerebral oxygenation in neurocritical care patients.
- 21 November 2014
- Vol. 81 (8) , 876-84
Assessment of cerebral oxygenation in neurocritical care patients: comparison of a new four wavelengths forehead regional saturation in oxygen sensor (EQUANOX®) with brain tissue oxygenation. A prospective observational study.
Because of restricted information given by monitoring solely intracranial pressure and cerebral perfusion pressure, assessment of the cerebral oxygenation in neurocritical care patients would be of interest. The aim of this study was to determinate the correlation between the non-invasive measure regional saturation in oxygen (rSO2) with a third generation NIRS monitor and an invasive measure of brain tissue oxygenation tension (PbtO2). We conducted a prospective, observational, unblinded study including neurocritical care patients requiring a PbtO2 monitoring. Concomitant measurements of rSO2 were performed with a four wavelengths forehead sensor (EQUANOX Advance®) of the EQUANOX® 7600 System. We determined the correlation between rSO2 and PbtO2 and the ability of the rSO2 to detect ischemic episodes defined by a PbtO2 less than 15 mmHg. The rSO2 ischemic threshold was 60%. During 2 months, 8 consecutives patients, including 275 measurements, were studied. There was no correlation between rSO2 and PbtO2 (r=0.016 [-0.103-0.134], r2=0.0003, P=0.8). On the 86 ischemic episodes detected by PbtO2, only 13 were also detected by rSO2. ROC curve showed the inability for rSO2 to detect cerebral hypoxia episodes (AUC=0.54). rSO2 cannot be used as a substitute for PbtO2 to monitor cerebral oxygenation in neurocritical care patients.
- Open Access
- 5 February 2013
- Published by Springer Nature in Critical Care
- Vol. 17 (1) , R24
Evaluation of early mini-bronchoalveolar lavage in the diagnosis of health care-associated pneumonia: a prospective study
Introduction Health care-associated pneumonia (HCAP) has been proposed as a new category of respiratory infection to identify patients at risk of multidrug-resistant (MDR) pathogens. The American Thoracic Society's recommendation for HCAP treatment is to use broad-spectrum and multiple antibiotics. However, this strategy may be economically expensive and promote antimicrobial resistance when a multisensitive pathogen is not identified. Methods We prospectively included all patients presenting with HCAP in the emergency department. Blood cultures and fiberoptic bronchoscope-guided distal protected small volume bronchoalveolar lavage (FODP mini-BAL) were performed in each patient. Empirical antibiotic therapy was adapted when microbiological findings were available. The primary objective was to assess whether FODP mini-BAL is more efficient than blood cultures in identifying pathogens with the ratio of identification between both techniques as principal criteria. Results We included 54 patients with HCAP. Pathogens were identified in 46.3% of cases using mini-BAL and in 11.1% of cases using blood cultures (P P Conclusions FODP mini-BAL was more efficient than blood cultures for identifying pathogens in patients presenting with HCAP. When bacteriological identification was obtained, antibiotic therapy was adapted in 100% of cases. See related letter by Sircar et al.,http://ccforum.com/content/17/2/428
- 5 February 2013
- Published by Springer Nature in Critical Care
- Vol. 17 (1) , R24
Open AccessEvaluation of early mini-bronchoalveolar lavage in the diagnosis of health care-associated pneumonia: a prospective study
Introduction Health care-associated pneumonia (HCAP) has been proposed as a new category of respiratory infection to identify patients at risk of multidrug-resistant (MDR) pathogens. The American Thoracic Society's recommendation for HCAP treatment is to use broad-spectrum and multiple antibiotics. However, this strategy may be economically expensive and promote antimicrobial resistance when a multisensitive pathogen is not identified. Methods We prospectively included all patients presenting with HCAP in the emergency department. Blood cultures and fiberoptic bronchoscope-guided distal protected small volume bronchoalveolar lavage (FODP mini-BAL) were performed in each patient. Empirical antibiotic therapy was adapted when microbiological findings were available. The primary objective was to assess whether FODP mini-BAL is more efficient than blood cultures in identifying pathogens with the ratio of identification between both techniques as principal criteria. Results We included 54 patients with HCAP. Pathogens were identified in 46.3% of cases using mini-BAL and in 11.1% of cases using blood cultures (P P Conclusions FODP mini-BAL was more efficient than blood cultures for identifying pathogens in patients presenting with HCAP. When bacteriological identification was obtained, antibiotic therapy was adapted in 100% of cases. See related letter by Sircar et al.,http://ccforum.com/content/17/2/428
- Open Access
- 20 May 2009
- Published by Springer Nature in Critical Care
- Vol. 13 (3) , R76
B-type natriuretic peptide release and left ventricular filling pressure assessed by echocardiographic study after subarachnoid hemorrhage: a prospective study in non-cardiac patients
Introduction: Serum B-type natriuretic peptide (BNP) is frequently elevated after subarachnoid hemorrhage (SAH), but whether this high BNP level is related to transient elevation of left ventricular filling pressure (LVFP) is unknown. However, in patients with preexistent cardiac pathologies, it is impossible to differentiate between BNP elevation caused by chronic cardiac abnormalities and BNP related to acute neurocardiac injury. Methods: All adult patients with SAH admitted to our intensive care unit were eligible. Patients were excluded for the following reasons: admission >48 hours after aneurysm rupture, pre-existing hypertension, or cardiac disease. Levels of BNP and cardiac troponin Ic were measured daily for 7 days. Echocardiography was performed by a blinded cardiologist on days 1, 2, and 7. Doppler signals from the mitral inflow, tissue Doppler, and the color M-mode–derived flow propagation velocity (FPV) were obtained to assess echo-estimated LVFP. Results: During a 3-year period, sixty-six consecutive patients with SAH were admitted. Thirty one patients were studied. The BNP level was >100 ng/L in 25 patients (80%) during the first 3 days, with a peak on day 2 (median, 126 ng/L) followed by a gradual decrease (median variation days 1 to 7, 70%). All patients had an ejection fraction >50%. Early transmitral velocity/tissue Doppler mitral annular early diastolic velocity was low: 5.4 (± 1.5) on day 1, 5.8 (± 1.2) on day 2, and 5.1 (± 0.9) on day 7. Early transmitral velocity/FPV was also low: 1.27 (± 0.4), 1.25 (± 0.3), and 1.1 (± 0.2) on days 1, 2, and 7, respectively. Cardiac troponin Ic levels ranged from 0 to 3.67 μg/L and were correlated with BNP (r = 0.63, P < 0.01). Conclusions: BNP rises gradually over two days and return to normal within a week after SAH. Its release is associated with myocardial necrosis, but is unrelated to elevated LVFP assessed by echocardiography.
- 20 May 2009
- Published by Springer Nature in Critical Care
- Vol. 13 (3) , R76
Open AccessB-type natriuretic peptide release and left ventricular filling pressure assessed by echocardiographic study after subarachnoid hemorrhage: a prospective study in non-cardiac patients
Introduction: Serum B-type natriuretic peptide (BNP) is frequently elevated after subarachnoid hemorrhage (SAH), but whether this high BNP level is related to transient elevation of left ventricular filling pressure (LVFP) is unknown. However, in patients with preexistent cardiac pathologies, it is impossible to differentiate between BNP elevation caused by chronic cardiac abnormalities and BNP related to acute neurocardiac injury. Methods: All adult patients with SAH admitted to our intensive care unit were eligible. Patients were excluded for the following reasons: admission >48 hours after aneurysm rupture, pre-existing hypertension, or cardiac disease. Levels of BNP and cardiac troponin Ic were measured daily for 7 days. Echocardiography was performed by a blinded cardiologist on days 1, 2, and 7. Doppler signals from the mitral inflow, tissue Doppler, and the color M-mode–derived flow propagation velocity (FPV) were obtained to assess echo-estimated LVFP. Results: During a 3-year period, sixty-six consecutive patients with SAH were admitted. Thirty one patients were studied. The BNP level was >100 ng/L in 25 patients (80%) during the first 3 days, with a peak on day 2 (median, 126 ng/L) followed by a gradual decrease (median variation days 1 to 7, 70%). All patients had an ejection fraction >50%. Early transmitral velocity/tissue Doppler mitral annular early diastolic velocity was low: 5.4 (± 1.5) on day 1, 5.8 (± 1.2) on day 2, and 5.1 (± 0.9) on day 7. Early transmitral velocity/FPV was also low: 1.27 (± 0.4), 1.25 (± 0.3), and 1.1 (± 0.2) on days 1, 2, and 7, respectively. Cardiac troponin Ic levels ranged from 0 to 3.67 μg/L and were correlated with BNP (r = 0.63, P < 0.01). Conclusions: BNP rises gradually over two days and return to normal within a week after SAH. Its release is associated with myocardial necrosis, but is unrelated to elevated LVFP assessed by echocardiography.
- 1 March 2009
- Published by Wiley in Acta Anaesthesiologica Scandinavica
- Vol. 53 (3) , 416-417
Weaning failure from mechanical ventilation due to dilated cardiomyopathy: successful use of levosimendan
- 1 March 2009
- Published by Wiley in Acta Anaesthesiologica Scandinavica
- Vol. 53 (3) , 416-417
Weaning failure from mechanical ventilation due to dilated cardiomyopathy: successful use of levosimendan
- Open Access
- 22 August 2008
- Published by Springer Nature in Cases Journal
- Vol. 1 (1) , 124
Protective ventilation in ARDS: as soon as possible. An immediate use of HFOV
To report the immediate use of High-Frequency Oscillatory ventilation in an adult acute respiratory distress syndrome. Case report. Intensive care unit at the Military Teaching Hospital of Toulon. A 64-yr-old Caucasian male who developed acute respiratory distress syndrome in the course of severe falciparum malaria. Initial use of HFO to minimise ventilator-induced lung injury. Rapid improvement of PaO2/fraction of inspired oxygen from 172 mmHg (NIV) to 310 mmHg with HFO. No ventilator-induced injury on CT scan after 5 days of invasive ventilation. In contrast with previous studies, we successfully used lung protective ventilation with HFO immediately. Further studies, with immediate, rather than rescue use of HFO ventilation, are needed.
- 22 August 2008
- Published by Springer Nature in Cases Journal
- Vol. 1 (1) , 124
Open AccessProtective ventilation in ARDS: as soon as possible. An immediate use of HFOV
To report the immediate use of High-Frequency Oscillatory ventilation in an adult acute respiratory distress syndrome. Case report. Intensive care unit at the Military Teaching Hospital of Toulon. A 64-yr-old Caucasian male who developed acute respiratory distress syndrome in the course of severe falciparum malaria. Initial use of HFO to minimise ventilator-induced lung injury. Rapid improvement of PaO2/fraction of inspired oxygen from 172 mmHg (NIV) to 310 mmHg with HFO. No ventilator-induced injury on CT scan after 5 days of invasive ventilation. In contrast with previous studies, we successfully used lung protective ventilation with HFO immediately. Further studies, with immediate, rather than rescue use of HFO ventilation, are needed.
- 1 February 2008
- Published by Elsevier in Annales Françaises d'Anesthésie et de Réanimation
- Vol. 27 (2) , 172-176
Immunomodulation au cours d’un cas de leptospirose grave avec défaillance multiviscérale : échanges plasmatiques, immunoglobulines ou corticoïdes ?
- 1 February 2008
- Published by Elsevier in Annales Françaises d'Anesthésie et de Réanimation
- Vol. 27 (2) , 172-176
Immunomodulation au cours d’un cas de leptospirose grave avec défaillance multiviscérale : échanges plasmatiques, immunoglobulines ou corticoïdes ?