MPMauro Pittiruti

Mauro Pittiruti

*This is an algorithmically generated author record based on publicly available information.

Mauro Pittiruti has a total of 52 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Ultrasound-guided “short” midline catheters for difficult venous access in the emergency department: a retrospective analysis

    by Giancarlo Scoppettuolo, Mauro Pittiruti, Sara Pitoni, Laura Dolcetti, Alessandro Emoli, Alessandro Mitidieri, Ivano Migliorini, Maria Giuseppina Annetta

    Acutely ill patients admitted to the emergency department (ED) constantly require at least one fast and reliable peripheral intravenous (PIV) access. In many conditions (morbid obesity, underweight state, chronic diseases, intravenous drug abuse, adverse local conditions, etc.), PIV placement may be challenging. Ultrasound guidance is a useful tool for obtaining a peripheral intravenous access in the emergency department, particularly when superficial veins are difficult to identify by palpation and direct visualization, though standard peripheral intravenous cannulas are not ideal for this technique of insertion and may have limited duration. Long polyurethane catheters inserted with ultrasound guidance and direct Seldinger technique appear to have several advantages over short cannulas in terms of success of insertion and of duration. A retrospective analysis was conducted on all the ultrasound-guided peripheral venous accesses obtained by insertion of long polyurethane catheters in patients admitted to the emergency department of our university hospital during 1 year. The main indication to the procedure was the urgent need of a peripheral venous access in patients with superficial veins difficult to palpate and/or visualize. All relevant data concerning the insertion and the maintenance of these peripheral lines were collected from the chart. Seventy-six patients were included in this review. The success rate of insertion was 100 %, with an average of 1.57 punctures per each successful cannulation. The mean time needed for the complete procedure was 9.5 min. In 73 % of patients, the catheter was used for more than 1 week; a minority of catheters were removed prematurely for end of use. No major infective or thrombotic complication was reported. In our experience, 8- to 10-cm-long polyurethane catheters may offer a fast and reliable peripheral venous access in the emergency department, if placed by ultrasound guidance and with the Seldinger technique. Further studies with prospective, randomized, and controlled design are warranted to confirm our results.


    • 13 May 2015
      • Vol. 82  (3) , 320-31

    Immunonutrients in critically ill patients: an analysis of the most recent literature.

    by Maria G Annetta, Mauro Pittiruti, Pietro Vecchiarelli, Davide Silvestri, Anselmo Caricato, Massimo Antonelli

    Modulation of inflammatory and immune response to critical illness has been the goal of much research in the last decade and a variety of drugs and nutrients (so called "immunonutrients") have been tested in experimental models with promising results. Though, in the clinical setting of intensive care, their efficacy have been inconsistently proven, most likely because the effects of each drug may vary in relation to the timing, the dose, the route of administration, the interaction with other nutrients, the severity of illness and many other factors. Though the early studies of the beginning of this century (2000-2009) have shown some clinical benefits, recent multicenter trials (2011-2015) have failed to prove a consistent benefit of immunonutrition in terms of mortality or other clinical endpoints. Reviewing the latest evidence-based documents on this subject (multicenter trials, systematic reviews, meta-analyses and international guidelines), there is no convincing evidence that immunonutrients may be beneficial in the critically ill. Considering that these substances invariably increase the costs of health care and may be unsafe or even harmful in some subgroups, particularly in septic patients, we conclude that routine administration of immune-nutrients (glutamine, arginine, omega-3 fatty acids, selenium, etc.) cannot be currently recommended in the critically ill.


  • A Prospective, Randomized Comparison of three different types of Valved and Non-Valved Peripherally inserted Central Catheters

    by Mauro Pittiruti, Alessandro Emoli, Patrizia Porta, Bruno Marche, Rosa DeAngelis, Giancarlo Scoppettuolo

    Purpose: Few randomized studies have investigated the impact of valved and non-valved power-injectable peripherally inserted central catheters (PICCs) in terms of incidence of occlusion, infection, malfunction and venous thrombosis. Methods: We have prospectively compared three types of third-generation polyurethane PICCs. One hundred and eighty adult patients candidate to chemotherapy were randomized into three groups: power-injectable PICCs with Solo-2 proximal valve (Bard); power-injectable PICCs with PASV (Pressure Activated Safety Valve) proximal valve (Navilyst); and non-valved power-injectable PICCs (Medcomp). All PICCs were single lumen 4Fr, inserted according to a well-defined protocol - maximal barrier precautions, ultrasound guidance, intracavitary electrocardiography (IC-ECG), and so on - and managed according to the recommendations of the most recent guidelines (antisepsis with 2% chlorhexidine, transparent dressing, sutureless device, strict ‘scrub the hub’ policy, neutral displacement needle-free connectors and so on). All catheters were flushed with 10 ml saline before and after each infusion, or with 20 ml saline after blood sampling or infusion of blood products. No heparin was used. Results: We detected no complications at insertion; no PICC-related bloodstream infections; no dislocations; five cases of transient occlusion and two cases of persistent withdrawal occlusion, evenly distributed among the groups; one episode of complete irreversible obstruction (group A); four episodes of asymptomatic peripheral venous thrombosis; one episode of symptomatic, severe central vein thrombosis (group B). In 31% of PICCs in group A (19/61) and in 65% of group B (39/60), difficulties with gravity infusion were reported; three PICCs of group A were complicated by rupture of the intravascular tract during pump infusion. Five PICCs were removed because of complications, four in group A (one obstruction; three ruptures) and one in group B (central venous thrombosis). Conclusion: We found no clinical advantages of valved vs. non-valved PICCs.


  • The Intracavitary ECG Method for Positioning the Tip of Central Venous access Devices in Pediatric Patients: Results of an Italian Multicenter Study

    by Francesca Rossetti, Mauro Pittiruti, Massimo Lamperti, Ugo Graziano, Davide Celentano, Giuseppe Capozzoli

    Purpose: The Italian Group for Venous Access Devices (GAVeCeLT) has carried out a multicenter study investigating the safety and accuracy of intracavitary electrocardiography (IC-ECG) in pediatric patients. Methods: We enrolled 309 patients (age 1 month-18 years) candidate to different central venous access devices ( VAD) - 56 peripherally inserted central catheters (PICC), 178 short term centrally inserted central catheters (CICC), 65 long term VADs, 10 VADs for dialysis - in five Italian Hospitals. Three age groups were considered: A (<4 years, n = 157), B (4-11 years, n = 119), and C (12-18 years, n = 31). IC-ECG was applicable in 307 cases. The increase of the P wave on IC-ECG was detected in all cases but two. The tip of the catheter was positioned at the cavo-atrial junction (CAJ) (i.e., at the maximal height of the P wave on IC-ECG) and the position was checked during the procedure by fluoroscopy or chest x-ray, considering the CAJ at 1-2 cm (group A), 1.5-3 cm (group B), or 2-4 cm (group C) below the carina. Results: There were no complications related to IC-ECG. The overall match between IC-ECG and x-ray was 95.8% (96.2% in group A, 95% in group B, and 96.8% in group C). In 95 cases, the IC-ECG was performed with a dedicated ECG monitor, specifically designed for IC-ECG (Nautilus, Romedex): in this group, the match between IC-ECG and x-ray was 98.8%. Conclusions: We conclude that the IC-ECG method is safe and accurate in the pediatric patients. The applicability of the method is 99.4% and its feasibility is 99.4%. The accuracy is 95.8% and even higher (98.8%) when using a dedicated ECG monitor.


  • Il protocollo ‘ISP’ (Inserzione Sicura dei PICC): un “bundle” di otto raccomandazioni per minimizzare le complicanze legate all’impianto dei cateteri centrali ad inserimento periferico (PICC)

    by Alessandro Emoli, Serena Cappuccio, Bruno Marche, Andrea Musarò, Giancarlo Scoppettuolo, Mauro Pittiruti

    The ISP (Safe Insertion of PICCs) protocol: a bundle of 8 recommendations to minimize the complications related to the peripherally inserted central venous catheters (PICC)


  • The Intracavitary ECG Method for Positioning the Tip of Central Venous Catheters: Results of an Italian Multicenter Study

    by Mauro Pittiruti, Daniele Bertollo, Ermanno Briglia, Massimo Buononato, Giuseppe Capozzoli, Luigi De Simone, Antonio La Greca, Cecilia Pelagatti, Pier Sandro Sette

    Purpose: The aim of this multicenter study was to assess the feasibility, safety, and accuracy of the intracavitary ECG method for real-time positioning of the tip of different types of central venous catheters. Methods: A total of 1444 catheter insertions in adult patients were studied in eight Italian centers (539 ports, 245 PICCs, 325 tunneled CVCs, 335 non-tunneled CVCs). Patients with no visible P wave at the standard baseline ECG were excluded. Depending on the type of catheter and its purpose, the target was to position the tip either (a) at the cavo-atrial junction, or (b) in the lower third of the superior vena cava, or (c) in the upper part of the atrium. The final position was verified by a post-procedural chest x-ray. Results: The method was feasible in 99.3% of all cases. There were no complications potentially related to the method itself. At the final x-ray control, 83% of all tips were positioned exactly at the target; 12.4% were positioned within 1–2 cm from the target, but still in a correct central position; only 3.8% were malpositioned. The mismatch between intra-procedural ECG method and post-procedural x-ray was significantly lower when the x-ray was taken in supine position. Conclusions: Our multicenter study confirms that the intracavitary ECG method for real time verification of tip position is accurate, safe, feasible in all adult patients and applicable to any type of short-term or long-term central venous access device.


  • Ultrasound Guided Central Vascular Access in Neonates, Infants and Children

    by Mauro Pittiruti

    Ultrasound guided central venous cannulation is rapidly becoming the standard technique for achieving a central line in neonates, infants and children. Older techniques such as surgical cutdown and ‘blind’ percutaneous venipuncture have many disadvantages: they are time consuming, vein consuming and/or associated with dangerous immediate or late complications. On the other hand, ultrasound has only advantages, giving the operator the possibility of (a) choosing the most appropriate and safest venous access on the basis of ultrasound assessment, (b) performing a 100% safe insertion, (c) ruling out malpositions or pleuro-pulmonary damages, during and after the procedure. Ultrasound guided central venous cannulation has been described in many clinical studies of the last decade, each one showing the higher efficacy and safety of ultrasound guidance in children when compared to the traditional landmark method. Ultrasound can be used for puncturing many different deep veins of the arm, neck, groin and thorax. The vein can be visualized either in short axis or in long axis, while the puncture can be performed ‘in-plane’ (when the needle trajectory is included in the plane of the ultrasound probe) or ‘out-of-plane’ (when the needle trajectory is not in that plane). Though, the best clinical results of ultrasound guidance can be achieved - particularly in neonates and infants - only if the operator has been properly trained in this technique through an appropriate curriculum that should include theory lessons, simulation practice and a tutored learning curve.


  • Open Access

    Clinical experience with power-injectable PICCs in intensive care patients

    by Mauro Pittiruti, Alberto Brutti, Davide Celentano, Massimiliano Pomponi, Daniele G Biasucci, Maria Giuseppina Annetta, Giancarlo Scoppettuolo

    Introduction: In the ICU, peripherally inserted central catheters (PICCs) may be an alternative option to standard central venous catheters, particularly in patients with coagulation disorders or at high risk for infection. Some limits of PICCs (such as low flow rates) may be overcome with the use of power-injectable catheters. Methods: We retrospectively reviewed all of the power-injectable PICCs inserted in adult and pediatric patients in the ICU during a 12-month period, focusing on the rate of complications at insertion and during maintenance. Results: We collected 89 power-injectable PICCs (in adults and in children), both multiple and single lumen. All insertions were successful. There were no major complications at insertion and no episodes of catheter-related bloodstream infection. Non-infective complications during management were not clinically significant. There was one episode of symptomatic thrombosis during the stay in the ICU and one episode after transfer of a patient to a non-intensive ward. Conclusion: Power-injectable PICCs have many advantages in the ICU: they can be used as multipurpose central lines for any type of infusion including high-flow infusion, for hemodynamic monitoring, and for high-pressure injection of contrast media during radiological procedures. Their insertion is successful in 100% of cases and is not associated with significant risks, even in patients with coagulation disorders. Their maintenance is associated with an extremely low rate of infective and non-infective complications.


  • Simulation training for vascular access interventions

    by Ingemar J.A. Davidson, Min C. Yoo, Daniel G. Biasucci, Patrick Browne, Cathy Dees, Bart Dolmatch, Maurizio Gallieni, Antonio La Greca, James R. Korndorffer, Billy Nolen, et al.

    Training and learning in the field of access for dialysis, including peritoneal and hemodialysis and access for oncologic patients, is well suited for the use of simulators, simulated case learning, and root cause analysis of adverse outcomes and team training. Simulators range over a wide spectrum from simple suture learning devices, inexpensive systems for venous puncture simulation, such as a turkey breast or leg with a pressurized tunneled rubber or graft conduit, to sophisticated computer designed simulators to teach interventional procedures such as vascular access angiogram, balloon angioplasty and stent placing. Team training capitalizes on the principles used in aviation, known as Crew Resource Management (CRM) or Human Factor (HF). The objectives of team training are to improve communication and leadership skills, to use checklists to prevent errors, to promote a change in the attitudes towards vascular access from learning through mistakes in a non-punitive environment, to impacting positively the employee performance and to increase staff retention by making the workplace safer, more efficient and user-friendly.