Paula L. Watson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Paula L. Watson has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Pratik P. Pandharipande
Department of Anesthesiology, Vanderbilt University Medical Center, Nashville, TN
4 shared publications Ayumi K. Shintani
Department of Biostatistics, Vanderbilt University Medical Center, Nashville, TN
2 shared publicationsE Wesley Ely
Center for Health Services Research and Division of Allergy/Pulmonary/Critical Care Medicine, Vanderbilt University School of Medicine, 21st Avenue South, Nashville, TN 37232, USA
2 shared publicationsE. Wesley Ely
Department of Pediatrics, Children’s Hospital of Pittsburgh, Pittsburgh, PA
2 shared publications- Bernardino Vaccaro
Department of Psychiatry, Boston VA Healthcare System, 1400 VFW Parkway, West Roxbury, MA 02132, USA
1 shared publication Beth A. Malow
Division of Sleep Disorders, Vanderbilt University Medical Center, Nashville, TN
1 shared publication
Latest Publications
- 1 October 2014
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 42 (10) , 2244-2251
Burst Suppression on Processed Electroencephalography as a Predictor of Postcoma Delirium in Mechanically Ventilated ICU Patients
Objectives: Many patients, due to a combination of illness and sedatives, spend a considerable amount of time in a comatose state that can include time in burst suppression. We sought to determine if burst suppression measured by processed electroencephalography during coma in sedative-exposed patients is a predictor of post-coma delirium during critical illness. Design: Observational convenience sample cohort. Setting: Medical and surgical ICUs in a tertiary care medical center. Patients: Cohort of 124 mechanically ventilated ICU patients. Interventions: None. Measurements and Main Results: Depth of sedation was monitored twice daily using the Richmond Agitation-Sedation Scale and continuously monitored by processed electroencephalography. When noncomatose, patients were assessed for delirium twice daily using Confusion Assessment Method for the ICU. Multiple logistic regression and Cox proportional hazards regression were used to assess associations between time in burst suppression and both prevalence and time to resolution of delirium, respectively, adjusting for time in deep sedation and a principal component score consisting of Acute Physiology and Chronic Health Evaluation II score and cumulative doses of sedatives while comatose. Of the 124 patients enrolled and monitored, 55 patients either never had coma or never emerged from coma, yielding 69 patients for whom we performed these analyses; 42 of these 69 (61%) had post-coma delirium. Most patients had burst suppression during coma, although often short-lived (median [interquartile range] time in burst suppression, 6.4 [1–58] min). After adjusting for covariates, even this short time in burst suppression independently predicted a higher prevalence of post-coma delirium (odds ratio, 4.16; 95% CI, 1.27–13.62; p = 0.02) and a lower likelihood (delayed) resolution of delirium (hazard ratio, 0.78; 95% CI, 0.53–0.98; p = 0.04). Conclusions: Time in burst suppression during coma, as measured by processed electroencephalography, was an independent predictor of prevalence and time to resolution of postcoma/post–deep sedation delirium. These findings of this single-center investigation support lighter sedation strategies.
- 1 October 2014
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 42 (10) , 2244-2251
Burst Suppression on Processed Electroencephalography as a Predictor of Postcoma Delirium in Mechanically Ventilated ICU Patients
Objectives: Many patients, due to a combination of illness and sedatives, spend a considerable amount of time in a comatose state that can include time in burst suppression. We sought to determine if burst suppression measured by processed electroencephalography during coma in sedative-exposed patients is a predictor of post-coma delirium during critical illness. Design: Observational convenience sample cohort. Setting: Medical and surgical ICUs in a tertiary care medical center. Patients: Cohort of 124 mechanically ventilated ICU patients. Interventions: None. Measurements and Main Results: Depth of sedation was monitored twice daily using the Richmond Agitation-Sedation Scale and continuously monitored by processed electroencephalography. When noncomatose, patients were assessed for delirium twice daily using Confusion Assessment Method for the ICU. Multiple logistic regression and Cox proportional hazards regression were used to assess associations between time in burst suppression and both prevalence and time to resolution of delirium, respectively, adjusting for time in deep sedation and a principal component score consisting of Acute Physiology and Chronic Health Evaluation II score and cumulative doses of sedatives while comatose. Of the 124 patients enrolled and monitored, 55 patients either never had coma or never emerged from coma, yielding 69 patients for whom we performed these analyses; 42 of these 69 (61%) had post-coma delirium. Most patients had burst suppression during coma, although often short-lived (median [interquartile range] time in burst suppression, 6.4 [1–58] min). After adjusting for covariates, even this short time in burst suppression independently predicted a higher prevalence of post-coma delirium (odds ratio, 4.16; 95% CI, 1.27–13.62; p = 0.02) and a lower likelihood (delayed) resolution of delirium (hazard ratio, 0.78; 95% CI, 0.53–0.98; p = 0.04). Conclusions: Time in burst suppression during coma, as measured by processed electroencephalography, was an independent predictor of prevalence and time to resolution of postcoma/post–deep sedation delirium. These findings of this single-center investigation support lighter sedation strategies.
- 1 August 2013
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 41 (8) , 1958-1967
Atypical Sleep in Ventilated Patients
Objectives: Standard sleep scoring criteria may be unreliable when applied to critically ill patients. We sought to quantify typical and atypical polysomnographic findings in critically ill patients and to begin development and reliability testing of methodology to characterize the atypical polysomnographic tracings that confound standard sleep scoring criteria. Design: Prospective convenience sample. Setting: Two academic, tertiary care medical centers. Patients: Thirty-seven critically ill, mechanically ventilated, medical ICU patients. Interventions: None. Measurements and Main Results: Mechanically ventilated subjects were monitored by continuous polysomnography. After noting frequent atypical polysomnographic findings (i.e., lack of stage N2 markers, the presence of polymorphic delta, burst suppression, or isoelectric electroencephalography), attempts to use standard sleep scoring criteria alone were abandoned. Atypical polysomnographic findings were characterized and used to develop a modified scoring system. Polysomnographic data were scored manually via this revised scoring scheme. Of 37 medical ICU patients enrolled, 36 experienced atypical sleep, which accounted for 85% of all recorded data, with 5.1% normal sleep and 9.4% wake. Coupling observed patient arousal levels with polysomnographic characteristics revealed that standard polysomnographic staging criteria did not reliably determine the presence or absence of sleep. Rapid eye movement occurred in only five patients (14%). The revised scoring system incorporating frequently seen atypical characteristics yielded very high interrater reliability (weighted κ = 0.80; bootstrapped 95% CI, [0.48, 0.89]). Conclusions: Analysis of polysomnographic data revealed profound deficiencies in standard scoring criteria due to a predominance of atypical polysomnographic findings in ventilated patients. The revised scoring scheme proved reliable in sleep staging and may serve as a building block in future work.
- 1 August 2013
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 41 (8) , 1958-1967
Atypical Sleep in Ventilated Patients
Objectives: Standard sleep scoring criteria may be unreliable when applied to critically ill patients. We sought to quantify typical and atypical polysomnographic findings in critically ill patients and to begin development and reliability testing of methodology to characterize the atypical polysomnographic tracings that confound standard sleep scoring criteria. Design: Prospective convenience sample. Setting: Two academic, tertiary care medical centers. Patients: Thirty-seven critically ill, mechanically ventilated, medical ICU patients. Interventions: None. Measurements and Main Results: Mechanically ventilated subjects were monitored by continuous polysomnography. After noting frequent atypical polysomnographic findings (i.e., lack of stage N2 markers, the presence of polymorphic delta, burst suppression, or isoelectric electroencephalography), attempts to use standard sleep scoring criteria alone were abandoned. Atypical polysomnographic findings were characterized and used to develop a modified scoring system. Polysomnographic data were scored manually via this revised scoring scheme. Of 37 medical ICU patients enrolled, 36 experienced atypical sleep, which accounted for 85% of all recorded data, with 5.1% normal sleep and 9.4% wake. Coupling observed patient arousal levels with polysomnographic characteristics revealed that standard polysomnographic staging criteria did not reliably determine the presence or absence of sleep. Rapid eye movement occurred in only five patients (14%). The revised scoring system incorporating frequently seen atypical characteristics yielded very high interrater reliability (weighted κ = 0.80; bootstrapped 95% CI, [0.48, 0.89]). Conclusions: Analysis of polysomnographic data revealed profound deficiencies in standard scoring criteria due to a predominance of atypical polysomnographic findings in ventilated patients. The revised scoring scheme proved reliable in sleep staging and may serve as a building block in future work.
- 1 September 2012
- Published by Elsevier in Best Practice & Research Clinical Anaesthesiology
- Vol. 26 (3) , 355-366
Delirium: Is sleep important?
- 1 September 2012
- Published by Elsevier in Best Practice & Research Clinical Anaesthesiology
- Vol. 26 (3) , 355-366
Delirium: Is sleep important?
- Open Access
- 1 January 2009
- Published by Springer Nature in Critical Care
- Vol. 13 (6) , 234
Bench-to-bedside review: Delirium in ICU patients - importance of sleep deprivation
Delirium occurs frequently in critically ill patients and has been associated with both short-term and long-term consequences. Efforts to decrease delirium prevalence have been directed at identifying and modifying its risk factors. One potentially modifiable risk factor is sleep deprivation. Critically ill patients are known to experience poor sleep quality with severe sleep fragmentation and disruption of sleep architecture. Poor sleep while in the intensive care unit is one of the most common complaints of patients who survive critical illness. The relationship between delirium and sleep deprivation remains controversial. However, studies have demonstrated many similarities between the clinical and physiologic profiles of patients with delirium and sleep deprivation. This article aims to review the literature, the clinical and neurobiologic consequences of sleep deprivation, and the potential relationship between sleep deprivation and delirium in intensive care unit patients. Sleep deprivation may prove to be a modifiable risk factor for the development of delirium with important implications for the acute and long-term outcome of critically ill patients.
- 1 January 2009
- Published by Springer Nature in Critical Care
- Vol. 13 (6) , 234
Open AccessBench-to-bedside review: Delirium in ICU patients - importance of sleep deprivation
Delirium occurs frequently in critically ill patients and has been associated with both short-term and long-term consequences. Efforts to decrease delirium prevalence have been directed at identifying and modifying its risk factors. One potentially modifiable risk factor is sleep deprivation. Critically ill patients are known to experience poor sleep quality with severe sleep fragmentation and disruption of sleep architecture. Poor sleep while in the intensive care unit is one of the most common complaints of patients who survive critical illness. The relationship between delirium and sleep deprivation remains controversial. However, studies have demonstrated many similarities between the clinical and physiologic profiles of patients with delirium and sleep deprivation. This article aims to review the literature, the clinical and neurobiologic consequences of sleep deprivation, and the potential relationship between sleep deprivation and delirium in intensive care unit patients. Sleep deprivation may prove to be a modifiable risk factor for the development of delirium with important implications for the acute and long-term outcome of critically ill patients.
- 1 December 2008
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 36 (12) , 3171-3177
Presence of electroencephalogram burst suppression in sedated, critically ill patients is associated with increased mortality
Vy doses of sedatives. Burst suppression has never been studied as a potential risk factor for death in patients without a known neurologic disorder or injury. Design: Post hoc analysis of a prospectively observational cohort study. Setting: Medical intensive care units of a tertiary care, university-based medical center. Patients: A total of 125 mechanically ventilated, adult, critically ill patients. Measurements and Main Results: A validated arousal scale (Richmond Agitation-Sedation Scale) was used to measure sedation level, and the bispectral index monitor was used to capture electroencephalogram data. Burst suppression occurred in 49 of 125 patients (39%). For analysis, the patients were divided into those with burst suppression (49 of 125, 39%) and those without burst suppression (76 of 125, 61%). All baseline variables were similar between the two groups, with the overall cohort demonstrating a high severity of illness (Acute Physiology and Chronic Health Evaluation II scores of 27.4 ± 8.2) and 98% receiving sedation. Of those with burst suppression, 29 of 49 (59%) died within 6 months compared with 25 of 76 (33%) who did not demonstrate burst suppression. Using time-dependent Cox regression to adjust for clinically important covariates (age, Charlson comorbidity score, baseline dementia, Acute Physiology and Chronic Health Evaluation II, Sequential Organ Failure Assessment, coma, and delirium), patients who experienced burst suppression were found to have a statistically significant higher 6-month mortality [Hazard’s ratio = 2.04, 95% confidence interval, 1.12–3.70, p = 0.02]. Conclusion: The presence of burst suppression, which was unexpectedly high in this medical intensive care unit population, was an independent predictor of increased risk of death at 6 months. This association should be studied prospectively on a larger scale in mechanically ventilated, critically ill patients....
- 1 December 2008
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 36 (12) , 3171-3177
Presence of electroencephalogram burst suppression in sedated, critically ill patients is associated with increased mortality
Vy doses of sedatives. Burst suppression has never been studied as a potential risk factor for death in patients without a known neurologic disorder or injury. Design: Post hoc analysis of a prospectively observational cohort study. Setting: Medical intensive care units of a tertiary care, university-based medical center. Patients: A total of 125 mechanically ventilated, adult, critically ill patients. Measurements and Main Results: A validated arousal scale (Richmond Agitation-Sedation Scale) was used to measure sedation level, and the bispectral index monitor was used to capture electroencephalogram data. Burst suppression occurred in 49 of 125 patients (39%). For analysis, the patients were divided into those with burst suppression (49 of 125, 39%) and those without burst suppression (76 of 125, 61%). All baseline variables were similar between the two groups, with the overall cohort demonstrating a high severity of illness (Acute Physiology and Chronic Health Evaluation II scores of 27.4 ± 8.2) and 98% receiving sedation. Of those with burst suppression, 29 of 49 (59%) died within 6 months compared with 25 of 76 (33%) who did not demonstrate burst suppression. Using time-dependent Cox regression to adjust for clinically important covariates (age, Charlson comorbidity score, baseline dementia, Acute Physiology and Chronic Health Evaluation II, Sequential Organ Failure Assessment, coma, and delirium), patients who experienced burst suppression were found to have a statistically significant higher 6-month mortality [Hazard’s ratio = 2.04, 95% confidence interval, 1.12–3.70, p = 0.02]. Conclusion: The presence of burst suppression, which was unexpectedly high in this medical intensive care unit population, was an independent predictor of increased risk of death at 6 months. This association should be studied prospectively on a larger scale in mechanically ventilated, critically ill patients....
- Open Access
- 1 January 2007
- Published by Springer Nature in Critical Care
- Vol. 11 (4) , 159
Measuring sleep in critically ill patients: beware the pitfalls
Survivors of critical illness frequently report poor sleep while in the intensive care unit (ICU), and sleep deprivation has been hypothesized to lead to emotional distress, ICU delirium and neurocognitive dysfunction, prolongation of mechanical ventilation, and decreased immune function. Thus, the careful study of sleep in the ICU is essential to understanding possible relationships with adverse clinical outcomes. Such research, however, must be conducted using sleep measurement techniques that have important limitations in this unique setting. Polysomnography (PSG) is considered the gold standard but is cumbersome, time consuming, and expensive. As such, alternative methods of sleep measurement such as actigraphy, processed electroencephalography monitors, and subjective observation are often used. Though helpful in some instances, data obtained using these methods can often be inaccurate and misleading. Even PSG itself must be interpreted with caution in this population due to effects of critical illness and associated treatments.
- 1 January 2007
- Published by Springer Nature in Critical Care
- Vol. 11 (4) , 159
Open AccessMeasuring sleep in critically ill patients: beware the pitfalls
Survivors of critical illness frequently report poor sleep while in the intensive care unit (ICU), and sleep deprivation has been hypothesized to lead to emotional distress, ICU delirium and neurocognitive dysfunction, prolongation of mechanical ventilation, and decreased immune function. Thus, the careful study of sleep in the ICU is essential to understanding possible relationships with adverse clinical outcomes. Such research, however, must be conducted using sleep measurement techniques that have important limitations in this unique setting. Polysomnography (PSG) is considered the gold standard but is cumbersome, time consuming, and expensive. As such, alternative methods of sleep measurement such as actigraphy, processed electroencephalography monitors, and subjective observation are often used. Though helpful in some instances, data obtained using these methods can often be inaccurate and misleading. Even PSG itself must be interpreted with caution in this population due to effects of critical illness and associated treatments.