Meike Römer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Meike Römer has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Jouko Yliruusi
University of Helsinki
3 shared publications- Jukka Rantanen
Department of Pharmacy, University of Copenhagen, Denmark
3 shared publications Jyrki Heinämäki
University of Helsinki
3 shared publicationsNiklas Sandler
Astra Zeneca R&D, Pharmaceutical & Analytical Research & Development
3 shared publicationsInna Miroshnyk
Division of Pharmaceutical Technology, Faculty of Pharmacy, University of Helsinki, P.O. Box 56, 00014 Helsinki, Finland
2 shared publications- Clare Joanna Strachan
Drug Research Program, Division of Pharmaceutical Chemistry and Technology, Faculty of Pharmacy, University of Helsinki, Viikinkaari 5 E, 00790 Helsinki, Finland
1 shared publication
Latest Publications
- 8 October 2008
- Published by Springer Nature in AAPS PharmSciTech
- Vol. 9 (4) , 1047-1053
Prediction of Tablet Film-coating Thickness Using a Rotating Plate Coating System and NIR Spectroscopy
The purpose of this research was to create a calibration model based on near-infrared (NIR) spectroscopy data obtained during a small-scale coating process to predict in-line the coating layer thickness of tablets coated in a side-vented drum coater. The developed setup for the small-scale coating process consisted of a rotating plate with 20 tablets molds that pass a spraying unit, a heating unit, and an in-line NIR spectroscopy probe during one rotation. High-density polyethylene (HDPE) was compressed to flat-faced tablets, and these were coated with a sustained release coating suspension containing Kollicoat IR and Kollicoat SR 30D. The film thickness of these tablets was determined for each tablet individually with a digital micrometer. A calibration model of predicted film thickness versus real-film thickness using PLS regression was developed. This model was tested against in-line NIR data obtained from a coating drum process, in which biconvex HDPE tablets were film-coated with the same film-coating suspension. The model predicted a final coating thickness of 240 μm, while the measured average thickness (n = 100 tablets) was 210 μm. Taking into account the use of a different setup and differently shaped tablets, it was possible to predict the coating thickness with accuracy comparable to the one of the digital micrometer. Thus, the small-scale rotating plate system was found to be an efficient means of preparing calibration model for a tablet-coating drum process.
- 8 October 2008
- Published by Springer Nature in AAPS PharmSciTech
- Vol. 9 (4) , 1047-1053
Prediction of Tablet Film-coating Thickness Using a Rotating Plate Coating System and NIR Spectroscopy
The purpose of this research was to create a calibration model based on near-infrared (NIR) spectroscopy data obtained during a small-scale coating process to predict in-line the coating layer thickness of tablets coated in a side-vented drum coater. The developed setup for the small-scale coating process consisted of a rotating plate with 20 tablets molds that pass a spraying unit, a heating unit, and an in-line NIR spectroscopy probe during one rotation. High-density polyethylene (HDPE) was compressed to flat-faced tablets, and these were coated with a sustained release coating suspension containing Kollicoat IR and Kollicoat SR 30D. The film thickness of these tablets was determined for each tablet individually with a digital micrometer. A calibration model of predicted film thickness versus real-film thickness using PLS regression was developed. This model was tested against in-line NIR data obtained from a coating drum process, in which biconvex HDPE tablets were film-coated with the same film-coating suspension. The model predicted a final coating thickness of 240 μm, while the measured average thickness (n = 100 tablets) was 210 μm. Taking into account the use of a different setup and differently shaped tablets, it was possible to predict the coating thickness with accuracy comparable to the one of the digital micrometer. Thus, the small-scale rotating plate system was found to be an efficient means of preparing calibration model for a tablet-coating drum process.
- 1 September 2008
- Published by Elsevier in Journal of Pharmaceutical Sciences
- Vol. 97 (9) , 4020-4029
Phase Transformation of Erythromycin A Dihydrate During Fluid Bed Drying
- 1 September 2008
- Published by Elsevier in Journal of Pharmaceutical Sciences
- Vol. 97 (9) , 4020-4029
Phase Transformation of Erythromycin A Dihydrate During Fluid Bed Drying
- 30 September 2007
- Published by Elsevier in European Journal of Pharmaceutical Sciences
- Vol. 32 (1) , S48
Solid-state transformation of erythromycin A dihydrate during drying monitored by near infrared spectroscopy
- 30 September 2007
- Published by Elsevier in European Journal of Pharmaceutical Sciences
- Vol. 32 (1) , S48
Solid-state transformation of erythromycin A dihydrate during drying monitored by near infrared spectroscopy
- 1 August 2007
- Published by Elsevier in European Journal of Pharmaceutics and Biopharmaceutics
- Vol. 67 (1) , 246-252
Phase transformations of erythromycin A dihydrate during pelletisation and drying
- 1 August 2007
- Published by Elsevier in European Journal of Pharmaceutics and Biopharmaceutics
- Vol. 67 (1) , 246-252
Phase transformations of erythromycin A dihydrate during pelletisation and drying