MVMarylene Viana

Marylene Viana

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Marylene Viana has a total of 37 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Jeu de rôle et simulation d’une entreprise ou comment former les futurs professionnels de l’industrie pharmaceutique

    by Marylène Viana

    La mise sur le marché d’un nouveau médicament fait intervenir des spécialistes de diverses disciplines. Les futurs professionnels de l’industrie pharmaceutique doivent non seulement acquérir des connaissances scientifiques variées afin d’être capables d’intégrer l’ensemble des problématiques, mais ils doivent également développer leurs compétences personnelles afin de savoir gérer efficacement les projets qui leur seront confiés. La démarche pédagogique mise en œuvre à la faculté de pharmacie de Limoges consiste à mettre les étudiants en situation d’apprentissage actif sous forme de jeu de rôle. Disposant de 500 g de principe actif, chaque groupe d’étudiants doit mettre au point et produire un lot de comprimés, et développer les contrôles pharmacotechniques et analytiques appropriés. Ce projet conduit les étudiants à s’organiser sous la forme d’une entreprise pharmaceutique virtuelle qui vise à déposer une demande d’Autorisation de Mise sur le Marché pour les différents comprimés élaborés. Finalement, un audit réalisé par des étudiants de Master 2 Management de la Qualité, permet d’avoir un regard extérieur sur le travail effectué et de compléter la démarche par une approche technico-réglementaire et qualité.

  • Open Access

    Investigation of the Compressibility and Compactibility of Titanate Nanotube-API Composites

    by Barbara Sipos, Klára Pintye-Hódi, Géza Regdon, Zoltán Kónya, Maryléne Viana, Tamás Sovány

    The present work aims to reveal the pharma-industrial benefits of the use of hydrothermally synthesised titanate nanotube (TNT) carriers in the manufacturing of nano-sized active pharmaceutical ingredients (APIs). Based on this purpose, the compressibility and compactibility of various APIs (diltiazem hydrochloride, diclofenac sodium, atenolol and hydrochlorothiazide) and their 1:1 composites formed with TNTs were investigated in a comparative study, using a Lloyd 6000R uniaxial press instrumented with a force gauge and a linear variable differential transformer extensometer. The tablet compression was performed without the use of any excipients, thus providing the precise energetic characterisation of the materials’ behaviour under pressure. In addition to the powder functionality test, the post-compressional properties of the tablets were also determined and evaluated. The results of the energetic analysis demonstrated that the use of TNTs as drug carriers is beneficial in every step of the tabletting process: besides providing better flowability and more favourable particle rearrangement, it highly decreases the elastic recovery of the APIs and results in ideal plastic deformation. Moreover, the post-compressional properties of the TNT–API composites were found to be exceptional (e.g., great tablet hardness and tensile strength), affirming the above results and proving the potential in the use of TNT carriers for drug manufacturing.


  • Comparison of Three Dissolution Apparatuses for Testing Calcium Phosphate Pellets used as Ibuprofen Delivery Systems

    by Emilie Chevalier, Marylène Viana, Aymeric Artaud, Lisette Chomette, Samir Haddouchi, Gille Devidts, Dominique Chulia

    Porous calcium phosphate pellets were produced according to two granulation processes (low and high shear wet granulations) and drug loaded with five ibuprofen contents (1.75%, 7%, 12.5%, 22%, and 36%) in order to ensure both bone defect filling and local drug delivery. The drug-release kinetics from the two types of pellets was studied using three dissolution apparatuses: paddle apparatus, reciprocating cylinder, and flow-through cell. The paper compared the three dissolution methods and considered the effect of the granulation process on the ibuprofen-release kinetics. Dissolution data were analyzed using the Weibull function as well as the difference (f1) and similarity (f2) factors. Dissolution kinetics was not influenced by the granulation process, regardless of the dissolution apparatus and of the drug content. The comparison of the three dissolution devices indicated that ibuprofen was released faster from granules loaded with 36% of drug content with the reciprocating apparatus, due to the disintegration of the granules occurring during the dissolution test. For the other drug contents, dissolution profiles were not significantly different from one apparatus to another. However, the flow-through cell seemed to be more suitable for the drug-release study of implantable materials.


  • Comparison of low-shear and high-shear granulation processes: effect on implantable calcium phosphate granule properties

    by E. Chevalier, M. Viana, S. Cazalbou, D. Chulia

    Background: Calcium phosphate porous ceramics present a great interest not only as complex bone defect fillers but also as drug delivery systems. Most of the methods described in the literature to fabricate pellets are based on compaction, casting into spherical molds, or on processes such as liquid immiscibility or foaming. Despite wet granulation is used in a wide range of applications in pharmaceuticals, food, detergents, fertilizers, and minerals, it is not applied in the biomaterial field to produce granules. Methods: In this study physicochemical and in vitro drug delivery properties of implantable calcium phosphate granules, produced by two wet agglomeration processes, were compared. Pellets obtained by high shear granulation (granulation in a Mi-Pro apparatus) were shown to be more spherical and less friable than granules elaborated by low shear process (granulation in a Kenwood apparatus). Although Mi-Pro pellets had a slightly lower porosity compared to Kenwood granules, ibuprofen loading efficiency and dissolution profiles were not statistically different and the release mechanism was mainly controlled by diffusion, in both cases. Conclusion: Mi-Pro pellets appeared to be better candidates as bone defect fillers and local drug delivery systems as far as they were more spherical and less friable than Kenwood agglomerates.


  • Comparison of single pot and multiphase granulation. Part 2: Effect of the drying process on granules manufactured in a single pot granulator and dried either in situ or in a fluid bed dryer

    by K. Giry, M. Viana, M. Genty, F. Louvet, P. Wüthrich, D. Chulia

    The aim of this study was to highlight the effect of the drying process on granules manufactured in a pilot scale single pot granulator and dried either in situ or in a fluid bed dryer, for formulations differing in drug substance and its concentration (1%; 25%). Although most of raw data were within specifications, single pot drying tended to improve granule comprimability and seemed less sensitive to formulation. Moreover, it was demonstrated that the formulation impacted on granule median diameter, packing ability, comprimability, residual lower punch pressure and tablet dissolution kinetics. Interactions between process and formulation were highlighted concerning tablet tensile strength and uniformity of mass.


  • Comparison of single pot and multiphase granulation. Part 1: Effect of the high shear granulator on granule properties according to the drug substance and its concentration

    by K. Giry, M. Viana, M. Genty, F. Louvet, P. Wüthrich, D. Chulia

    International audiencePharmaceutical granulations are usually developed with regard to a specific manufacturing process but switching from one piece of equipment to another can be necessary to comply with the available industrial equipment. Investigations were undertaken on formulations differing in the drug substance and in its concentration. Our aim was to highlight the effect of the granulation process on granules manufactured in a pilot scale Moritz® Turbosphere TS50 or in Fielder® PMA 65 and dried in a Glatt® GPCG1 fluid bed dryer. The granulation process and formulation parameters showed a significant impact on granule size distribution, behaviour under pressure, and on tablet mechanical properties and dissolution kinetics


  • Drawbacks of Surfactant Presence on the Dissolution and Mechanical Properties of Detergent Tablets: How to Control Interfaces by Surfactant Localization

    by Florence Chantraine, Marylène Viana, Christelle Pouget, Nelly Brielles, Olivier Mondain‐Monval, Paul Branlard, Gilles Rubinstenn, Dominique Chulia

    The aim of this study is to limit the hurdles generated by the presence of a surfactant, i.e., sodium dodecyl sulfate (SDS), in effervescent detergent tablets containing a chlorine provider. The results are highlighted by investigating the tablet's functional characteristics (mechanical strength, disintegration time). A second objective is to increase the surfactant content of the tablet in order to improve the cleaning properties of the detergent formula without retaining the previous drawbacks. For low tablet porosity, mechanical properties are damaged by the presence of 2% of SDS and while disintegration through an erosion mechanism is slowed down. Experimental evidence indicated that these phenomena are associated with the coexistence of SDS and sodium dichloroisocyanurate (DCCNa). Their separation by locating SDS in the tablet core was encouraging but had limited value due to the slow dissolution of the SDS core. The problem was solved when 2% SDS was concentrated on one face of the tablet; however, a higher concentration induced a delayed disintegration due to the progressive erosion of SDS, which behaved as a massive solid. The coating of the tablet with SDS was beneficial because the dissolution of the film delayed effervescence and consequently disintegration. Neither coating the SDS particles with cellulosic film nor including them in zeolite was an appropriate solution. On the other hand, segregating SDS and DCCNa by placing them in separate layers of the tablet produced very conclusive results when microcrystalline cellulose and an effervescent system were added to the SDS. Furthermore, this bilayer tablet allowed the SDS content to be increased while a satisfactory tensile strength and a low disintegration time were retained.


  • Characterization of porous textures in order to explain the influence of a surfactant on the end-use properties of detergent tablets

    by Florence Chantraine, Marylene Viana, Nelly Brielles, Olivier Mondain-Monval, Christelle Pouget, Paul Branlard, Gilles Rubinstenn, Dominique Chulia


  • Influence of Process Parameters on Pellets Elaborated in a Mi-Pro High-Shear Granulator

    by E. Chevalier, M. Viana, C. Pouget, D. Chulia

    The aim of the study was to prepare porous pellets several hundred micrometers in diameter into or onto which drug substances could be embedded. Wet granulation was carried out on a powder mix of α-lactose and polyvinylpyrrolidone in a Mi-Pro high-shear granulator. The process parameters were investigated to point out their influence on pellet physical properties. The reference conditions of granulation that gave the most satisfactory pellets in size and shape were determined by adjusting the volume and the distribution rate of water. Increasing impeller speed resulted in an increase in granule size and granulation yield and in a decrease in proportion of fines. The granules showed easy flowing for all granulation conditions. Adjusting process parameters enabled control of size, shape, surface area, and porosity of the granules and thus the design of ready to use granules to which drug substances could be associated by deposition or inclusion.