Lauren Briens
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Lauren Briens has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
Cedric Briens
Faculty of Engineering The University of Western Ontario London Ontario Canada
3 shared publicationsAllan Carter
Biomedical Engineering, Faculty of Engineering, The University of Western Ontario, London, ON N6A 5B9, Canada
2 shared publicationsAllison Crouter
Faculty of Engineering, Western University, London, Ontario, N6A 5B9, Canada
2 shared publicationsAustin Cameron
Faculty of Engineering, Western University, London, Ontario, Canada
2 shared publications- Cedric Briens
ICFAR, Western University London Ontario Canada
2 shared publications Garett Morin
Biomedical Engineering, The University of Western Ontario, London, Canada, N6A 5B9
2 shared publications
Latest Publications
- 5 March 2021
- Published by Wiley in The Canadian Journal of Chemical Engineering
- Vol. 100 (S1) , S25-S37
Design and development of a rotating heater pyrolysis reactor
Biochar is a valuable product of pyrolysis. A new rotating heater pyrolysis reactor (RHP) was developed to process a variety of biomass feedstocks of up to 30 L and produce biochar batches of several kilograms. The RHP design was simple, allowing for easy construction, low‐cost operation, and low energy consumption. Biochar produced from softwood woodchip biomass in the RHP for 2–3 h was determined to have physical and chemical properties comparable to biochar produced from a conventional batch pyrolysis reactor at temperatures between 375–425°C.
- 5 March 2021
- Published by Wiley in The Canadian Journal of Chemical Engineering
- Vol. 100 (S1) , S25-S37
Design and development of a rotating heater pyrolysis reactor
Biochar is a valuable product of pyrolysis. A new rotating heater pyrolysis reactor (RHP) was developed to process a variety of biomass feedstocks of up to 30 L and produce biochar batches of several kilograms. The RHP design was simple, allowing for easy construction, low‐cost operation, and low energy consumption. Biochar produced from softwood woodchip biomass in the RHP for 2–3 h was determined to have physical and chemical properties comparable to biochar produced from a conventional batch pyrolysis reactor at temperatures between 375–425°C.
- 26 July 2019
- Published by Springer Nature in AAPS PharmSciTech
- Vol. 20 (7) , 269
Monitoring Magnesium Stearate Blending in a V-Blender Through Passive Vibration Measurements
Process analytical technologies are implemented within the pharmaceutical manufacturing process to rectify issues associated with current sampling methods. These include inline monitoring methods such as passive vibration measurements which are non-intrusive and less costly to other methods. In the final mixing stage of the tablet manufacturing process, a lubricant is added to ensure the mixture is ejected from the tablet die cleanly. To monitor this process, an accelerometer was attached to the lid of the V-blender loaded with various particles and magnesium stearate. At a fixed fill level, the lubricant concentration and particle mass were varied to investigate the effects of changes in process parameters on the signal vibrations measured by the sensor, the coefficient of restitution, and the flowability. It was found that measured vibrations from stress waves propagated upon collisions of the particles with the V-shell respond to and can distinguish differences in particles. As well, the magnesium stearate layer around particles alters energy dissipation and subsequently the measured vibrations. A mixing endpoint of uniform distribution of magnesium stearate with primary particles can be identified from vibrations measured by an accelerometer attached to the lid of the V-blender. The flowability change was considered negligible in the particles due to their physical morphology. These findings indicate that passive vibration measurements can be a viable, non-intrusive monitoring method while providing insight into V-blender mixing behaviors as well as improving process efficiency.
- 26 July 2019
- Published by Springer Nature in AAPS PharmSciTech
- Vol. 20 (7) , 269
Monitoring Magnesium Stearate Blending in a V-Blender Through Passive Vibration Measurements
Process analytical technologies are implemented within the pharmaceutical manufacturing process to rectify issues associated with current sampling methods. These include inline monitoring methods such as passive vibration measurements which are non-intrusive and less costly to other methods. In the final mixing stage of the tablet manufacturing process, a lubricant is added to ensure the mixture is ejected from the tablet die cleanly. To monitor this process, an accelerometer was attached to the lid of the V-blender loaded with various particles and magnesium stearate. At a fixed fill level, the lubricant concentration and particle mass were varied to investigate the effects of changes in process parameters on the signal vibrations measured by the sensor, the coefficient of restitution, and the flowability. It was found that measured vibrations from stress waves propagated upon collisions of the particles with the V-shell respond to and can distinguish differences in particles. As well, the magnesium stearate layer around particles alters energy dissipation and subsequently the measured vibrations. A mixing endpoint of uniform distribution of magnesium stearate with primary particles can be identified from vibrations measured by an accelerometer attached to the lid of the V-blender. The flowability change was considered negligible in the particles due to their physical morphology. These findings indicate that passive vibration measurements can be a viable, non-intrusive monitoring method while providing insight into V-blender mixing behaviors as well as improving process efficiency.
- 24 May 2019
- Published by Springer Nature in AAPS PharmSciTech
- Vol. 20 (5) , 199
An Investigation of Magnesium Stearate Mixing Performance in a V-Blender Through Passive Vibration Measurements
Prior to compression in tablet manufacturing, a lubricant is added and mixed in a V-blender to ensure the mixture is ejected from the tablet die smoothly. Mixing is conducted batch-wise and must be...
- 24 May 2019
- Published by Springer Nature in AAPS PharmSciTech
- Vol. 20 (5) , 199
An Investigation of Magnesium Stearate Mixing Performance in a V-Blender Through Passive Vibration Measurements
Prior to compression in tablet manufacturing, a lubricant is added and mixed in a V-blender to ensure the mixture is ejected from the tablet die smoothly. Mixing is conducted batch-wise and must be...
- 1 February 2019
- Published by Elsevier in Powder Technology
- Vol. 343, 723-732
A comparison of drum granulation of biochars
- 1 February 2019
- Published by Elsevier in Powder Technology
- Vol. 343, 723-732
A comparison of drum granulation of biochars
- 23 January 2019
- Published by Springer Nature in AAPS PharmSciTech
- Vol. 20 (2) , 84
Methods to Assess Mixing of Pharmaceutical Powders
The pharmaceutical manufacturing process consists of several steps, each of which must be monitored and controlled to ensure quality standards are met. The level of blending has an impact on the...
- 23 January 2019
- Published by Springer Nature in AAPS PharmSciTech
- Vol. 20 (2) , 84
Methods to Assess Mixing of Pharmaceutical Powders
The pharmaceutical manufacturing process consists of several steps, each of which must be monitored and controlled to ensure quality standards are met. The level of blending has an impact on the...
- 1 December 2018
- Published by Elsevier in International Journal of Pharmaceutics
- Vol. 552 (1-2) , 235-240
An application of deep learning to detect process upset during pharmaceutical manufacturing using passive acoustic emissions
- 1 December 2018
- Published by Elsevier in International Journal of Pharmaceutics
- Vol. 552 (1-2) , 235-240
An application of deep learning to detect process upset during pharmaceutical manufacturing using passive acoustic emissions
- 1 October 2018
- Published by Elsevier in International Journal of Pharmaceutics
- Vol. 549 (1-2) , 293-298
Inline acoustic monitoring to determine fluidized bed performance during pharmaceutical coating
- 1 October 2018
- Published by Elsevier in International Journal of Pharmaceutics
- Vol. 549 (1-2) , 293-298
Inline acoustic monitoring to determine fluidized bed performance during pharmaceutical coating
- 1 September 2014
- Published by Elsevier in International Journal of Pharmaceutics
- Vol. 472 (1-2) , 192-201
A review of monitoring methods for pharmaceutical wet granulation
- 1 September 2014
- Published by Elsevier in International Journal of Pharmaceutics
- Vol. 472 (1-2) , 192-201
A review of monitoring methods for pharmaceutical wet granulation
- 17 May 2014
- Published by Springer Nature in AAPS PharmSciTech
- Vol. 15 (4) , 1039-1048
A Comparison of Granules Produced by High-Shear and Fluidized-Bed Granulation Methods
Placebo granules were manufactured by both wet high-shear and fluidized-bed techniques. The granules were compared based on size, shape, surface morphology, and a variety of different flowability measurements. This comparison showed that granule formation and growth were different, with induction growth for high-shear granulation and steady growth for fluidized-bed granulation. Final granules from high-shear granulation were more spherical and dense compared with the irregular granules from fluidized-bed granulation. The high-shear granules demonstrated better overall flow properties.
- 17 May 2014
- Published by Springer Nature in AAPS PharmSciTech
- Vol. 15 (4) , 1039-1048
A Comparison of Granules Produced by High-Shear and Fluidized-Bed Granulation Methods
Placebo granules were manufactured by both wet high-shear and fluidized-bed techniques. The granules were compared based on size, shape, surface morphology, and a variety of different flowability measurements. This comparison showed that granule formation and growth were different, with induction growth for high-shear granulation and steady growth for fluidized-bed granulation. Final granules from high-shear granulation were more spherical and dense compared with the irregular granules from fluidized-bed granulation. The high-shear granules demonstrated better overall flow properties.
- 3 October 2013
- Published by Springer Nature in AAPS PharmSciTech
- Vol. 15 (1) , 65-74
The Effect of Moisture on the Flowability of Pharmaceutical Excipients
The effect of moisture content on flowability of six pharmaceutical powders (microcrystalline cellulose (MCC), hydroxypropyl methylcellulose (HPMC), carboxymethyl cellulose (CMC), polyvinylpyrrolidone (PVP), corn starch, and potato starch) was investigated. Powder flowability was measured using established static techniques and emerging dynamic avalanche behavior measurements. Static techniques did not provide enough resolution to clearly identify changes in flowability due to increasing powder moisture content. Avalanche time and its standard deviation showed that flowability of MCC, CMC, PVP, and potato starch decreased after a critical moisture content, flowability of corn starch increased and flowability did not significantly change for HPMC. The moisture decreased flowability by forming stronger interparticle liquid bridges and increased flowability by acting as a lubricant. The dynamic density of the celluloses and PVP decreased linearly with increasing moisture content as the particles swelled with water. The starches also swelled and decreased in dynamic density, but only after a moisture content corresponding to monolayer coverage of water around the particles was reached. As flowability and dynamic density change with moisture content, to ensure consistent production of high-quality tablets, the moisture content of the powders must be measured and controlled.
- 3 October 2013
- Published by Springer Nature in AAPS PharmSciTech
- Vol. 15 (1) , 65-74
The Effect of Moisture on the Flowability of Pharmaceutical Excipients
The effect of moisture content on flowability of six pharmaceutical powders (microcrystalline cellulose (MCC), hydroxypropyl methylcellulose (HPMC), carboxymethyl cellulose (CMC), polyvinylpyrrolidone (PVP), corn starch, and potato starch) was investigated. Powder flowability was measured using established static techniques and emerging dynamic avalanche behavior measurements. Static techniques did not provide enough resolution to clearly identify changes in flowability due to increasing powder moisture content. Avalanche time and its standard deviation showed that flowability of MCC, CMC, PVP, and potato starch decreased after a critical moisture content, flowability of corn starch increased and flowability did not significantly change for HPMC. The moisture decreased flowability by forming stronger interparticle liquid bridges and increased flowability by acting as a lubricant. The dynamic density of the celluloses and PVP decreased linearly with increasing moisture content as the particles swelled with water. The starches also swelled and decreased in dynamic density, but only after a moisture content corresponding to monolayer coverage of water around the particles was reached. As flowability and dynamic density change with moisture content, to ensure consistent production of high-quality tablets, the moisture content of the powders must be measured and controlled.