ANAlp Notghi

Alp Notghi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Alp Notghi has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Clinical Utility (Applications) of SPECT/CT

    by Tom Kane, Randeep Kulshrestha, Alp Notghi, Mark Elias


  • Open Access

    Myocardial perfusion scintigraphy: past, present and future

    by A Notghi, C S Low

    During the last two decades, radionuclide myocardial perfusion scintigraphy (MPS) has become established as the main functional cardiac imaging technique for the assessment of ischaemic heart disease (IHD). Despite a growing number of alternative functional imaging techniques, MPS still remains the most widely used technique, with a wealth of literature supporting its usefulness in assessing IHD and predicting prognosis. The technique itself has evolved, making it more reliable and robust, with additional ventricular functional information that further defines the prognosis in these patients. With the advent of hybrid single photon emission with CT and positron emission tomography with CT cameras together with the development of new camera technology that enables faster images with less radiation and better resolution, MPS will remain an essential part of IHD investigation. There are new promising radiopharmacological developments and applications such as radiolabelled fatty acids and meta-iodobenzylguanidine. These will widen the scope of nuclear medicine imaging to include patients with cardiac failure and acute chest pain presenting to accident and emergency departments. Nuclear medicine cardiac investigations will continue to have an essential role in the diagnosis, stratification and prognosis of patients with cardiac disease, complementing the new developing cardiac modalities such as CT coronary angiography and MRI.


  • Measuring SeHCAT retention

    by Alp Notghi, Joseph O’bRien, Chen Sheng Low, William Thomson

    TauroH-23-((75)Se)selena-25-homocholic acid (SeHCAT) retention has been used for the diagnosis of bile acid malabsorption since the early 1980s. Bile acid malabsorption has been increasingly recognized as an important cause of severe chronic diarroea with subsequent increase in the number of referrals for the SeHCAT test. In this study, we review and discuss the standard techniques for the measurement of SeHCAT retention and describe a simple and modified technique using a noncollimated whole-body scanner, suitable for most modern dual-headed cameras.


  • Acquiring diagnostic DaTSCAN images in claustrophobic or difficult patients using a 180° configuration

    by Alp Notghi, Joseph O'Brien, Elizabeth A. Clarke, William H. Thomson

    In this study, we have investigated the feasibility of a 180 degrees DaTSCAN brain SPECT acquisition. This technique has the advantage of being 'open view' for the patient and therefore more acceptable for claustrophobic patients. It also enables easier access for a technologist to hold the patient's head during acquisition to reduce movement in confused patients or in those with severe tremor. In the first part of this study, we validated the practicality and image quality of a 180 degrees acquisition using a DaTSCAN Alderson head phantom with different camera configurations on GE Infinia and Philips AXIS gamma cameras. The effect on image quality of using half the acquisition time was also assessed. In the second part of the study, 50 sets of patient data were reprocessed by reconstructing half of the 360 degrees data to mimic a single-head 180 degrees acquisition. The 180 degrees images were then compared with 360 degrees images for the same patient using a visual score system. The effect of half-time 180 degrees data acquisition on quantification was also assessed using GE QuantiSPECT software. All phantom images from 180 degrees acquisitions contained some degree of distortion at the periphery, but clearly retain the presence of centrally positioned caudate and putamen; hence 180 degrees acquisitions were deemed to produce clinically useful diagnostic images. The shorter (half) acquisition time leads to noisier but acceptable images for all configurations. In the patient study, there was complete agreement between the two reporters with no clinical difference in the diagnostic accuracy between the 180 degrees and 360 degrees images. However, 6 of 50 180 degrees images were marked as poor quality but reportable, compared with 0 of 50 in 360 degrees images. Quantification gave consistently lower nuclei to background ratio values for 180 degrees compared with 360 degrees for normal and abnormal patients. It is possible to obtain diagnostic DaTSCAN images using 180 degrees acquisition in difficult patients. The total length of the study may also be shortened by half using L-mode or V-mode camera head configuration.


  • Assessing the effect of increasing injection activity for myocardial perfusion imaging in overweight patients

    by A Notghi, F X Sundram, J W O'Brien, N B Smith

    In our previous publication, we proposed to increase the injection activity for overweight patients. We have now implemented this for our patients, i.e. increasing the activity for patients above 99 kg. In the present study, we audited whether this increased activity for overweight patients improved the myocardial counts effectively and also whether it improved the image quality for these patients. 125 consecutive normal myocardial perfusion studies were included into the study. The total left ventricular myocardial count was calculated, as was the total left ventricular myocardial volume using the Cedar Sinai QPS program. The myocardial count per millilitre of the myocardium (c ml(-1)) was correlated with patient weight using regression analysis. There was no significant difference (p = 0.120) among the mean myocardial counts for patients over 99 kg (n = 40, 1548 c ml(-1)) compared with patients in the 70-79 kg range (n = 26, 1746 c ml(-1)). This indicates that the previously proposed algorithm for adjusting injection activity maintains the count density in the myocardium and should be used for all patients over 99 kg. There was, however, a significant steady decrease with increased weight in the myocardial counts for patients under 100 kg (p<0.001), a range in which injection activity was not adjusted for weight. To correct for this, we now propose that the injection activity should be adjusted for all patients over 80 kg, using the previously proposed algorithm.


    • 1 September 2002
      • Vol. 43  (9) , 1181-3

    Improved body-outline imaging technique for localization of sentinel lymph nodes in breast surgery.

    by Elizabeth Clarke, Alp Notghi, Keith Harding

    Many centers use techniques for localizing the sentinel lymph node (SLN) associated with a breast tumor. Protocols involve the use of an intraoperative probe and blue dye but may or may not include scintigraphy. Three methods of body-outline imaging were investigated to aid SLN localization. Body outlines were acquired using a handheld source; a transmission image was acquired from a (57)Co-flood source; and, finally, a new method is described using a (153)Gd-line source attenuation correction for body outline. Method 1 images were of low quality, although 83% of SLNs were visualized. Body outline was unsatisfactory for surgical localization. Method 2 was unsatisfactory because of the lack of a lateral image. Method 3 enabled good presurgical visualization of the SLN (73%) and speeded surgical localization. The (153)Gd-line source consistently gives optimal-quality body-outline images. This source is simple, quick, and clearly locates the SLN on multiple projections.