Lisa A. Spacek
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Lisa A. Spacek has a total of 53 co-authors. Here are the top co-authors by number of shared publications:
- Allan R. Ronald
Department of Medicine, University of Manitoba, Winnipeg, Manitoba, Canada
3 shared publications - Harriet Mayanja-Kizza
Department of Medicine, Makerere University College of Health Sciences, Kampala, Uganda
3 shared publications Thomas C Quinn
From the *Academic Alliance for AIDS Care and Prevention and the Infectious Diseases Institute, Kampala, Uganda; †Makerere University, Kampala, Uganda; ‡Division of Infectious Diseases, Johns Hopkins Medical Institutions, Baltimore, MD; §University of Manitoba, Winnipeg, Canada; and ‖National Institute of Allergy and Infectious Diseases, National Institutes of Health, Bethesda, MD
3 shared publicationsAlexander Granok
Infectious Disease Associates, Nashua, New Hampshire
1 shared publicationAllan Currie
Infectious Disease Associates, Nashua, New Hampshire
1 shared publication- Andrew Kambugu
Makerere University
1 shared publication
Latest Publications
- Open Access
- 1 December 2015
- Published by IOP Publishing in Journal of Breath Research
- Vol. 9 (4) , 047109
Clinical utility of breath ammonia for evaluation of ammonia physiology in healthy and cirrhotic adults
Blood ammonia is routinely used in clinical settings to assess systemic ammonia in hepatic encephalopathy and urea cycle disorders. Despite its drawbacks, blood measurement is often used as a comparator in breath studies because it is a standard clinical test. We sought to evaluate sources of measurement error and potential clinical utility of breath ammonia compared to blood ammonia. We measured breath ammonia in real time by quartz enhanced photoacoustic spectrometry and blood ammonia in 10 healthy and 10 cirrhotic participants. Each participant contributed 5 breath samples and blood for ammonia measurement within 1 h. We calculated the coefficient of variation (CV) for 5 breath ammonia values, reported medians of healthy and cirrhotic participants, and used scatterplots to display breath and blood ammonia. For healthy participants, mean age was 22 years (±4), 70% were men, and body mass index (BMI) was 27 (±5). For cirrhotic participants, mean age was 61 years (±8), 60% were men, and BMI was 31 (±7). Median blood ammonia for healthy participants was within normal range, 10 μ mol L −1 (interquartile range (IQR), 3–18) versus 46 μ mol L −1 (IQR, 23–66) for cirrhotic participants. Median breath ammonia was 379 pmol mL −1 CO 2 (IQR, 265–765) for healthy versus 350 pmol mL −1 CO 2 (IQR, 180–1013) for cirrhotic participants. CV was 17 ± 6%. There remains an important unmet need in the evaluation of systemic ammonia, and breath measurement continues to demonstrate promise to fulfill this need. Given the many differences between breath and blood ammonia measurement, we examined biological explanations for our findings in healthy and cirrhotic participants. We conclude that based upon these preliminary data breath may offer clinically important information this is not provided by blood ammonia.
- 1 December 2015
- Published by IOP Publishing in Journal of Breath Research
- Vol. 9 (4) , 047109
Open AccessClinical utility of breath ammonia for evaluation of ammonia physiology in healthy and cirrhotic adults
Blood ammonia is routinely used in clinical settings to assess systemic ammonia in hepatic encephalopathy and urea cycle disorders. Despite its drawbacks, blood measurement is often used as a comparator in breath studies because it is a standard clinical test. We sought to evaluate sources of measurement error and potential clinical utility of breath ammonia compared to blood ammonia. We measured breath ammonia in real time by quartz enhanced photoacoustic spectrometry and blood ammonia in 10 healthy and 10 cirrhotic participants. Each participant contributed 5 breath samples and blood for ammonia measurement within 1 h. We calculated the coefficient of variation (CV) for 5 breath ammonia values, reported medians of healthy and cirrhotic participants, and used scatterplots to display breath and blood ammonia. For healthy participants, mean age was 22 years (±4), 70% were men, and body mass index (BMI) was 27 (±5). For cirrhotic participants, mean age was 61 years (±8), 60% were men, and BMI was 31 (±7). Median blood ammonia for healthy participants was within normal range, 10 μ mol L −1 (interquartile range (IQR), 3–18) versus 46 μ mol L −1 (IQR, 23–66) for cirrhotic participants. Median breath ammonia was 379 pmol mL −1 CO 2 (IQR, 265–765) for healthy versus 350 pmol mL −1 CO 2 (IQR, 180–1013) for cirrhotic participants. CV was 17 ± 6%. There remains an important unmet need in the evaluation of systemic ammonia, and breath measurement continues to demonstrate promise to fulfill this need. Given the many differences between breath and blood ammonia measurement, we examined biological explanations for our findings in healthy and cirrhotic participants. We conclude that based upon these preliminary data breath may offer clinically important information this is not provided by blood ammonia.
- 1 June 2011
- Published by SAGE Publications in International Journal of STD & AIDS
- Vol. 22 (6) , 310-314
Diagnostic accuracy of ultrasensitive heat-denatured HIV-1 p24 antigen in non-B subtypes in Kampala, Uganda
We evaluated the accuracy of heat-denatured, amplification-boosted ultrasensitive p24 assay (Up24) compared with reverse transcriptase polymerase chain reaction (RT-PCR). We tested 394 samples from Ugandans infected with HIV-1 non-B subtypes. We compared Up24 levels (HIV-1 p24 Core Profile enzyme-linked immunosorbent assay (ELISA), NEN Life Science Products) to RNA viral loads (Amplicor HIV-1 Monitor 1.5, Roche) by linear regression, and calculated sensitivity, specificity, positive and negative predictive values. Median viral load was 4.9 log10 copies/mL (interquartile range [IQR], 2.6–5.5); 114 samples (29%) were undetectable (500,000, 250,000–500,000, 100,000–250,000, 50,000–100,000 and 400–50,000 copies/mL, respectively. In conclusion, when compared with RT-PCR for patients infected with non-B subtypes, the Up24 demonstrated limited sensitivity especially at low viral loads. Moreover, the Up24 was positive in 33% of samples deemed undetectable by RT-PCR, which may limit the use of the Up24 to detect viral suppression.
- 1 June 2011
- Published by SAGE Publications in International Journal of STD & AIDS
- Vol. 22 (6) , 310-314
Diagnostic accuracy of ultrasensitive heat-denatured HIV-1 p24 antigen in non-B subtypes in Kampala, Uganda
We evaluated the accuracy of heat-denatured, amplification-boosted ultrasensitive p24 assay (Up24) compared with reverse transcriptase polymerase chain reaction (RT-PCR). We tested 394 samples from Ugandans infected with HIV-1 non-B subtypes. We compared Up24 levels (HIV-1 p24 Core Profile enzyme-linked immunosorbent assay (ELISA), NEN Life Science Products) to RNA viral loads (Amplicor HIV-1 Monitor 1.5, Roche) by linear regression, and calculated sensitivity, specificity, positive and negative predictive values. Median viral load was 4.9 log10 copies/mL (interquartile range [IQR], 2.6–5.5); 114 samples (29%) were undetectable (500,000, 250,000–500,000, 100,000–250,000, 50,000–100,000 and 400–50,000 copies/mL, respectively. In conclusion, when compared with RT-PCR for patients infected with non-B subtypes, the Up24 demonstrated limited sensitivity especially at low viral loads. Moreover, the Up24 was positive in 33% of samples deemed undetectable by RT-PCR, which may limit the use of the Up24 to detect viral suppression.
- Open Access
- 1 February 2009
- Published by Wiley in Journal of the International AIDS Society
- Vol. 12 (1) , 3
Development and evaluation of a clinical algorithm to monitor patients on antiretrovirals in resource-limited settings using adherence, clinical and CD4 cell count criteria
Routine viral load monitoring of patients on antiretroviral therapy (ART) is not affordable in most resource-limited settings. A cross-sectional study of 496 Ugandans established on ART was performed at the Infectious Diseases Institute, Kampala, Uganda. Adherence, clinical and laboratory parameters were assessed for their relationship with viral failure by multivariate logistic regression. A clinical algorithm using targeted viral load testing was constructed to identify patients for second-line ART. This algorithm was compared with the World Health Organization (WHO) guidelines, which use clinical and immunological criteria to identify failure in the absence of viral load testing. Forty-nine (10%) had a viral load of >400 copies/mL and 39 (8%) had a viral load of >1000 copies/mL. An algorithm combining adherence failure (interruption >2 days) and CD4 failure (30% fall from peak) had a sensitivity of 67% for a viral load of >1000 copies/mL, a specificity of 82%, and identified 22% of patients for viral load testing. Sensitivity of the WHO-based algorithm was 31%, specificity was 87%, and would result in 14% of those with viral suppression (<400 copies/mL) being switched inappropriately to second-line ART. Algorithms using adherence, clinical and CD4 criteria may better allocate viral load testing, reduce the number of patients continued on failing ART, and limit the development of resistance.
- 1 February 2009
- Published by Wiley in Journal of the International AIDS Society
- Vol. 12 (1) , 3
Open AccessDevelopment and evaluation of a clinical algorithm to monitor patients on antiretrovirals in resource-limited settings using adherence, clinical and CD4 cell count criteria
Routine viral load monitoring of patients on antiretroviral therapy (ART) is not affordable in most resource-limited settings. A cross-sectional study of 496 Ugandans established on ART was performed at the Infectious Diseases Institute, Kampala, Uganda. Adherence, clinical and laboratory parameters were assessed for their relationship with viral failure by multivariate logistic regression. A clinical algorithm using targeted viral load testing was constructed to identify patients for second-line ART. This algorithm was compared with the World Health Organization (WHO) guidelines, which use clinical and immunological criteria to identify failure in the absence of viral load testing. Forty-nine (10%) had a viral load of >400 copies/mL and 39 (8%) had a viral load of >1000 copies/mL. An algorithm combining adherence failure (interruption >2 days) and CD4 failure (30% fall from peak) had a sensitivity of 67% for a viral load of >1000 copies/mL, a specificity of 82%, and identified 22% of patients for viral load testing. Sensitivity of the WHO-based algorithm was 31%, specificity was 87%, and would result in 14% of those with viral suppression (<400 copies/mL) being switched inappropriately to second-line ART. Algorithms using adherence, clinical and CD4 criteria may better allocate viral load testing, reduce the number of patients continued on failing ART, and limit the development of resistance.
- 1 July 2008
- Published by Wolters Kluwer Health in JAIDS Journal of Acquired Immune Deficiency Syndromes
- Vol. 48 (3) , 297-303
Evaluation of Dynabeads and Cytospheres Compared With Flow Cytometry to Enumerate CD4+ T Cells in HIV-Infected Ugandans on Antiretroviral Therapy
Background: Laboratory-based monitoring of antiretroviral therapy is essential but adds a significant cost to HIV care. The World Health Organization 2006 guidelines support the use of CD4 lymphocyte count (CD4) to define treatment failure in resource-limited settings. Methods: We compared CD4 obtained on replicate samples from 497 HIV-positive Ugandans (before and during ART) followed for 18 months by 2 manual bead-based assays, Dynabeads (Dynal Biotech), and Cytospheres (Beckman Coulter) with those generated by flow cytometry at the Infectious Diseases Institute in Kampala, Uganda. Results: We tested 1671 samples (123 before ART) with Dynabeads and 1444 samples (91 before ART) with Cytospheres. Mean CD4 was 231 cells/mm3 (SD, 139) and 239 cells/mm3 (SD, 140) by Dynabeads and flow cytometry, respectively. Mean CD4 was 186 cells/mm3 (SD, 101) and 242 cells/mm3 (SD, 136) by Cytospheres and flow cytometry, respectively. The mean difference in CD4 count by flow cytometry versus Dynabeads were 8.8 cells/mm3 (SD, 76.0) and versus Cytospheres were 56.8 cells/mm3 (SD, 85.8). The limits of agreement were −140.9 to 158.4 cells/mm3 for Dynabeads and −112.2 to 225.8 cells/mm3 for Cytospheres. Linear regression analysis showed higher correlation between flow cytometry and Dynabeads (r = 0.85, r2 = 0.73, slope = 0.85, intercept = 28) compared with the correlation between flow cytometry and Cytospheres (r = 0.78, r2 = 0.60, slope = 0.58, intercept = 45). Area under the receiver operating characteristics curve to predict CD4 3 was 0.928 for Dynabeads and 0.886 for Cytospheres. Conclusion: Although Dynabeads and Cytospheres both underestimated CD4 lymphocyte count compared with flow cytometry, in resource-limited settings with low daily throughput, manual bead-based assays may provide a less expensive alternative to flow cytometry.
- 1 July 2008
- Published by Wolters Kluwer Health in JAIDS Journal of Acquired Immune Deficiency Syndromes
- Vol. 48 (3) , 297-303
Evaluation of Dynabeads and Cytospheres Compared With Flow Cytometry to Enumerate CD4+ T Cells in HIV-Infected Ugandans on Antiretroviral Therapy
Background: Laboratory-based monitoring of antiretroviral therapy is essential but adds a significant cost to HIV care. The World Health Organization 2006 guidelines support the use of CD4 lymphocyte count (CD4) to define treatment failure in resource-limited settings. Methods: We compared CD4 obtained on replicate samples from 497 HIV-positive Ugandans (before and during ART) followed for 18 months by 2 manual bead-based assays, Dynabeads (Dynal Biotech), and Cytospheres (Beckman Coulter) with those generated by flow cytometry at the Infectious Diseases Institute in Kampala, Uganda. Results: We tested 1671 samples (123 before ART) with Dynabeads and 1444 samples (91 before ART) with Cytospheres. Mean CD4 was 231 cells/mm3 (SD, 139) and 239 cells/mm3 (SD, 140) by Dynabeads and flow cytometry, respectively. Mean CD4 was 186 cells/mm3 (SD, 101) and 242 cells/mm3 (SD, 136) by Cytospheres and flow cytometry, respectively. The mean difference in CD4 count by flow cytometry versus Dynabeads were 8.8 cells/mm3 (SD, 76.0) and versus Cytospheres were 56.8 cells/mm3 (SD, 85.8). The limits of agreement were −140.9 to 158.4 cells/mm3 for Dynabeads and −112.2 to 225.8 cells/mm3 for Cytospheres. Linear regression analysis showed higher correlation between flow cytometry and Dynabeads (r = 0.85, r2 = 0.73, slope = 0.85, intercept = 28) compared with the correlation between flow cytometry and Cytospheres (r = 0.78, r2 = 0.60, slope = 0.58, intercept = 45). Area under the receiver operating characteristics curve to predict CD4 3 was 0.928 for Dynabeads and 0.886 for Cytospheres. Conclusion: Although Dynabeads and Cytospheres both underestimated CD4 lymphocyte count compared with flow cytometry, in resource-limited settings with low daily throughput, manual bead-based assays may provide a less expensive alternative to flow cytometry.
- 1 February 2006
- Published by SAGE Publications in International Journal of STD & AIDS
- Vol. 17 (2) , 116-120
Clinical illness as a marker for initiation of HIV antiretroviral therapy in a rural setting, Rakai, Uganda
The aim of this study is to assess whether HIV-related illness and World Health Organization (WHO) clinical stage can be used to guide initiation of antiretroviral therapy (ART) in rural Rakai District, Uganda. A retrospective cohort analysis of 910 HIV-seroprevalent individuals randomly sampled from a community cohort was conducted. The associations between HIV-related clinical illness and HIV viral loads >55,000 copies/mL and death were evaluated as a guide for initiation of ART. Reporting one or more HIV-related illnesses was associated with high specificity for identifying HIV viral load >55,000 copies/mL and predicting death within 30 months. There were more deaths in those with one symptom at baseline (16.3%) and two or more symptoms (25.0%) than in those reporting no symptoms (9.6%; P = 0.001). HIV-related illness and WHO stage predicted disease progression. The specificity of clinical illness to predict viral load >55,000 copies/mL was high and could be used to rule in HIV disease requiring ART.
- 1 February 2006
- Published by SAGE Publications in International Journal of STD & AIDS
- Vol. 17 (2) , 116-120
Clinical illness as a marker for initiation of HIV antiretroviral therapy in a rural setting, Rakai, Uganda
The aim of this study is to assess whether HIV-related illness and World Health Organization (WHO) clinical stage can be used to guide initiation of antiretroviral therapy (ART) in rural Rakai District, Uganda. A retrospective cohort analysis of 910 HIV-seroprevalent individuals randomly sampled from a community cohort was conducted. The associations between HIV-related clinical illness and HIV viral loads >55,000 copies/mL and death were evaluated as a guide for initiation of ART. Reporting one or more HIV-related illnesses was associated with high specificity for identifying HIV viral load >55,000 copies/mL and predicting death within 30 months. There were more deaths in those with one symptom at baseline (16.3%) and two or more symptoms (25.0%) than in those reporting no symptoms (9.6%; P = 0.001). HIV-related illness and WHO stage predicted disease progression. The specificity of clinical illness to predict viral load >55,000 copies/mL was high and could be used to rule in HIV disease requiring ART.
- Open Access
- 15 January 2006
- Published by Oxford University Press (OUP) in Clinical Infectious Diseases
- Vol. 42 (2) , 252-259
Response to Antiretroviral Therapy in HIV-Infected Patients Attending a Public, Urban Clinic in Kampala, Uganda
Background. Access to antiretroviral therapy and human immunodeficiency virus (HIV) care is increasing in resource-limited settings. We evaluated clinical, behavioral, and demographic risk factors associated with virologic suppression in a public, urban clinic in Kampala, Uganda. Methods. We conducted a cross-sectional, observational study of 137 HIV-infected patients who were receiving antiretroviral therapy at the infectious diseases clinic at Mulago Hospital (Kampala). We measured the prevalence of viral suppression, evaluated risk factors associated with virologic failure, and documented phenotypic resistance patterns and genotypic mutations. Results. A total of 91 (66%) of 137 participants had an undetectable viral load (3 (interquartile range, 95–260 cells/mm3). The majority of the patients (91%) were treated with nonnucleoside reverse-transcriptase inhibitor—based 3-drug regimens. In multivariate analysis, treatment with the first antiretroviral regimen was associated with viral suppression (odds ratio, 2.6; 95% confidence interval, 1.1–6.1). In contrast, a history of unplanned treatment interruption was associated with virologic treatment failure (odds ratio, 0.2; 95% confidence interval, 0.1–0.6). Of 124 participants treated with nonnucleoside reverse-transcriptase inhibitors, 27 (22%) were documented to have experienced virologic treatment failure. The most common mutation detected was K103N (found in 14 of 27 patients with virologic treatment failure). Conclusions. Although many HIV-infected people treated in Kampala, Uganda, have advanced HIV disease, the majority of patients who received antiretroviral therapy experienced viral suppression and clinical benefit. Because of the frequent use of nonnucleoside reverse-transcriptase inhibitor—based therapy, the majority of resistance was against this drug class. In resource-limited settings, initiation of therapy with a potent, durable regimen, accompanied by stable drug supplies, will optimize the likelihood of viral suppression.
- 15 January 2006
- Published by Oxford University Press (OUP) in Clinical Infectious Diseases
- Vol. 42 (2) , 252-259
Open AccessResponse to Antiretroviral Therapy in HIV-Infected Patients Attending a Public, Urban Clinic in Kampala, Uganda
Background. Access to antiretroviral therapy and human immunodeficiency virus (HIV) care is increasing in resource-limited settings. We evaluated clinical, behavioral, and demographic risk factors associated with virologic suppression in a public, urban clinic in Kampala, Uganda. Methods. We conducted a cross-sectional, observational study of 137 HIV-infected patients who were receiving antiretroviral therapy at the infectious diseases clinic at Mulago Hospital (Kampala). We measured the prevalence of viral suppression, evaluated risk factors associated with virologic failure, and documented phenotypic resistance patterns and genotypic mutations. Results. A total of 91 (66%) of 137 participants had an undetectable viral load (3 (interquartile range, 95–260 cells/mm3). The majority of the patients (91%) were treated with nonnucleoside reverse-transcriptase inhibitor—based 3-drug regimens. In multivariate analysis, treatment with the first antiretroviral regimen was associated with viral suppression (odds ratio, 2.6; 95% confidence interval, 1.1–6.1). In contrast, a history of unplanned treatment interruption was associated with virologic treatment failure (odds ratio, 0.2; 95% confidence interval, 0.1–0.6). Of 124 participants treated with nonnucleoside reverse-transcriptase inhibitors, 27 (22%) were documented to have experienced virologic treatment failure. The most common mutation detected was K103N (found in 14 of 27 patients with virologic treatment failure). Conclusions. Although many HIV-infected people treated in Kampala, Uganda, have advanced HIV disease, the majority of patients who received antiretroviral therapy experienced viral suppression and clinical benefit. Because of the frequent use of nonnucleoside reverse-transcriptase inhibitor—based therapy, the majority of resistance was against this drug class. In resource-limited settings, initiation of therapy with a potent, durable regimen, accompanied by stable drug supplies, will optimize the likelihood of viral suppression.
- Open Access
- 1 September 2004
- Published by Oxford University Press (OUP) in Clinical Infectious Diseases
- Vol. 39 (5) , e46-e48
Shiga Toxin--Producing Escherichia coli as a Possible Etiological Agent of Chronic Diarrhea
We identified Shiga toxin—producing Escherichia coli (STEC) as the likely etiologic pathogen for chronic diarrhea in 2 patients, 1 of whom was immuno
- 1 September 2004
- Published by Oxford University Press (OUP) in Clinical Infectious Diseases
- Vol. 39 (5) , e46-e48
Open AccessShiga Toxin--Producing Escherichia coli as a Possible Etiological Agent of Chronic Diarrhea
We identified Shiga toxin—producing Escherichia coli (STEC) as the likely etiologic pathogen for chronic diarrhea in 2 patients, 1 of whom was immuno
- 1 June 2003
- Published by Wolters Kluwer Health in AIDS
- Vol. 17 (9) , 1311-1317
Total lymphocyte count and hemoglobin combined in an algorithm to initiate the use of highly active antiretroviral therapy in resource-limited settings
Objective: To develop clinical algorithms that improve the sensitivity of surrogate markers to initiate the use of highly active antiretroviral therapy (HAART) in resource-limited settings. Design: A retrospective evaluation of total lymphocyte counts (TLC) and hemoglobin to predict the CD4 lymphocyte count. Methods: A total of 3269 members of the Johns Hopkins HIV observational cohort contributed 22 690 paired observations of CD4 lymphocyte counts and TLC. Two methods were used to evaluate the effect of combining TLC and hemoglobin to predict CD4 cell counts below 200 cells/mm3 before the initiation of HAART in 1451 participants; 55.3% of participants had CD4 cell counts below 200 cells/mm3. Results: TLC below 1200 cells/mm3 and hemoglobin below 12 g/dl significantly predicted CD4 cell counts below 200 cells/mm3. For TLC alone sensitivity was 70.7% and specificity was 81.7%. For both men and women, we chose a TLC lower cutoff point of 1200 cells/mm3, an upper cutoff point of 2000 cells/mm3, and hemoglobin of 12 g/dl. For men, method I generated sensitivity of 78.0% and specificity of 77.5%. Method II improved specificity to 81.8%. For women, method I increased sensitivity to 85.6% and decreased specificity to 64.1%. Method II improved specificity to 81.4%. Conclusion: TLC below 1200 cells/mm3 were associated with CD4 cell counts below 200 cells/mm3 as in the WHO guidelines, but sensitivity was low. Adding hemoglobin to TLC increased sensitivity, thereby reducing the risk of false-negative results. Our model may serve as a template for the development of algorithms to initiate the use of HAART in resource-limited settings.
- 1 June 2003
- Published by Wolters Kluwer Health in AIDS
- Vol. 17 (9) , 1311-1317
Total lymphocyte count and hemoglobin combined in an algorithm to initiate the use of highly active antiretroviral therapy in resource-limited settings
Objective: To develop clinical algorithms that improve the sensitivity of surrogate markers to initiate the use of highly active antiretroviral therapy (HAART) in resource-limited settings. Design: A retrospective evaluation of total lymphocyte counts (TLC) and hemoglobin to predict the CD4 lymphocyte count. Methods: A total of 3269 members of the Johns Hopkins HIV observational cohort contributed 22 690 paired observations of CD4 lymphocyte counts and TLC. Two methods were used to evaluate the effect of combining TLC and hemoglobin to predict CD4 cell counts below 200 cells/mm3 before the initiation of HAART in 1451 participants; 55.3% of participants had CD4 cell counts below 200 cells/mm3. Results: TLC below 1200 cells/mm3 and hemoglobin below 12 g/dl significantly predicted CD4 cell counts below 200 cells/mm3. For TLC alone sensitivity was 70.7% and specificity was 81.7%. For both men and women, we chose a TLC lower cutoff point of 1200 cells/mm3, an upper cutoff point of 2000 cells/mm3, and hemoglobin of 12 g/dl. For men, method I generated sensitivity of 78.0% and specificity of 77.5%. Method II improved specificity to 81.8%. For women, method I increased sensitivity to 85.6% and decreased specificity to 64.1%. Method II improved specificity to 81.4%. Conclusion: TLC below 1200 cells/mm3 were associated with CD4 cell counts below 200 cells/mm3 as in the WHO guidelines, but sensitivity was low. Adding hemoglobin to TLC increased sensitivity, thereby reducing the risk of false-negative results. Our model may serve as a template for the development of algorithms to initiate the use of HAART in resource-limited settings.