Ann‐Katherine Carton

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ann‐Katherine Carton has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Dual-energy contrast-enhanced digital breast tomosynthesis – a feasibility study

    by A-K Carton, S C Gavenonis, J A Currivan, E F Conant, M D Schnall, A D A Maidment

    Contrast-enhanced digital breast tomosynthesis (CE-DBT) is a novel modality for imaging breast lesion morphology and vascularity. The purpose of this study is to assess the feasibility of dual-energy subtraction as a technique for CE-DBT (a temporal subtraction CE-DBT technique has been described previously). As CE-DBT evolves, exploration of alternative image acquisition techniques will contribute to its optimisation. Evaluation of dual-energy CE-DBT was conducted with Institutional Review Board (IRB) approval from our institution and in compliance with federal Health Insurance Portability and Accountability Act (HIPAA) guidelines. A 55-year old patient with a known malignancy in the right breast underwent imaging with MRI and CE-DBT. CE-DBT was performed in the medial lateral oblique view with a DBT system, which was modified under IRB approval to allow high-energy image acquisition with a 0.25 mm Cu filter. Image acquisition occurred via both temporal and dual-energy subtraction CE-DBT. Between the pre- and post-contrast DBT image sets, a single bolus of iodinated contrast agent (1.0 ml kg(-1)) was administered, followed by a 60 ml saline flush. The contrast agent and saline were administrated manually at a rate of similar to 2 ml s(-1). Images were reconstructed using filtered-back projection and transmitted to a clinical PACS workstation. Dual-energy CE-DBT was shown to be clinically feasible. In our index case, the dual-energy technique was able to provide morphology and kinetic information about the known malignancy. This information was qualitatively concordant with that of CE-MRI. Compared with the temporal subtraction CE-DBT technique, dual-energy CE-DBT appears less susceptible to motion artefacts.


  • FFDM image quality assessment using computerized image texture analysis

    by Rachelle Berger, Ann-Katherine Carton, Andrew D. A. Maidment, Despina Kontos

    Quantitative measures of image quality (IQ) are routinely obtained during the evaluation of imaging systems. These measures, however, do not necessarily correlate with the IQ of the actual clinical images, which can also be affected by factors such as patient positioning. No quantitative method currently exists to evaluate clinical IQ. Therefore, we investigated the potential of using computerized image texture analysis to quantitatively assess IQ. Our hypothesis is that image texture features can be used to assess IQ as a measure of the image signal-to-noise ratio (SNR). To test feasibility, the "Rachel" anthropomorphic breast phantom (Model 169, Gammex RMI) was imaged with a Senographe 2000D FFDM system (GE Healthcare) using 220 unique exposure settings (target/filter, kVs, and mAs combinations). The mAs were varied from 10%-300% of that required for an average glandular dose (AGD) of 1.8 mGy. A 2.5cm2 retroareolar region of interest (ROI) was segmented from each image. The SNR was computed from the ROIs segmented from images linear with dose (i.e., raw images) after flat-field and off-set correction. Image texture features of skewness, coarseness, contrast, energy, homogeneity, and fractal dimension were computed from the Premium ViewTM postprocessed image ROIs. Multiple linear regression demonstrated a strong association between the computed image texture features and SNR (R2=0.92, p≤0.001). When including kV, target and filter as additional predictor variables, a stronger association with SNR was observed (R2=0.95, p≤0.001). The strong associations indicate that computerized image texture analysis can be used to measure image SNR and potentially aid in automating IQ assessment as a component of the clinical workflow. Further work is underway to validate our findings in larger clinical datasets.


  • The effect of scatter and glare on image quality in contrast‐enhanced breast imaging using an full‐field flat panel detector

    by Ann‐Katherine Carton, Raymond Acciavatti, Johnny Kuo, Andrew D. A. Maidment

    The purpose of this study is to evaluate the performance of an antiscatter grid and its potential benefit on image quality for a full‐field digital mammography (FFDM) detector geometry at energies typical for temporal subtraction contrast‐enhanced (CE) breast imaging. The signal intensities from primary, scatter, and glare were quantified in images acquired with an FFDM detector using a Rh target and a 0.27 mm Cu filter at tube voltages ranging from 35 to 49 kV. Measurements were obtained at the center of the irradiation region of 20–80 mm thick breast‐equivalent phantoms. The phantoms were imaged with and without an antiscatter grid. Based on these data, the performance of the antiscatter grid was determined by calculating the primary and scatter transmission factors ( and ) and Bucky factors . In addition, glare‐to‐primary ratios (GPRs) and scatter‐to‐primary ratios (SPRs) were quantified. The effect of the antiscatter grid on the signal‐difference‐to‐noise ratio (SDNR) was also assessed. It was found that increases with kV but does not depend on the phantom thickness; values between 0.81 and 0.84 were measured. increases with kV and phantom thickness; values between 0.13 and 0.21 were measured. decreases with kV and increases with phantom thickness; ranges from 1.4 to 2.1. GPR is nearly constant, varying from 0.10 to 0.11. SPR without an antiscatter grid ranges from 0.35 to 1.34. decreases by approximately 9% from 35 to 49 kV for a given phantom thickness and is 3.5 times larger for an 80 mm thick breast‐equivalent phantom than for a 20 mm thick breast‐equivalent phantom. SPR with an antiscatter grid ranges from 0.06 to 0.31. increases by approximately 23% from 35 to 49 kV for a given phantom thickness; is four times larger for an 80 mm breast‐equivalent phantom than for a 20 mm breast‐equivalent phantom. When imaging a 25 mm PMMA plate at the same mean glandular dose with and without an antiscatter grid, the SDNR is 4% greater with a grid than without. For an 75mm PMMA plate, the SDNR is 20% greater with a grid. In conclusion, at the higher x‐ray energy range used for CE‐DM and CE‐DBT, an antiscatter grid significantly reduces SPR and improves SDNR. These effects are most pronounced for thick breasts.


  • Validation of MTF measurement for digital mammography quality control

    by Ann‐Katherine Carton, Dirk Vandenbroucke, Luc Struye, Andrew D. A. Maidment, Yen‐Hong Kao, Michael Albert, Hilde Bosmans, Guy Marchal

    The modulation transfer function (MTF) describes the spatial resolution properties of imaging systems. In this work, the accuracy of our implementation of the edge method for calculating the presampled MTF was examined. Synthetic edge images with known MTF were used as gold standards for determining the robustness of the edge method. These images simulated realistic data from clinical digital mammography systems, and contained intrinsic system factors that could affect the MTF accuracy, such as noise, scatter, and flat‐field nonuniformities. Our algorithm is not influenced by detector dose variations for MTF accuracy up to the sampling frequency. We investigated several methods for noise reduction, including truncating the supersampled line spread function (LSF), windowing the LSF, applying a local exponential fit to the LSF, and applying a monotonic constraint to the supersampled edge spread function. Only the monotonic constraint did not introduce a systematic error; the other methods could result in MTF underestimation. Overall, our edge method consistently computed MTFs which were in good agreement with the true MTF. The edge method was then applied to images from a commercial storage‐phosphor based digital mammography system. The calculated MTF was affected by the size (sides of 2.5, 5, or ) and the composition (lead or tungsten) of the edge device. However, the effects on the MTF were observed only with regard to the low frequency drop (LFD). Scatter nonuniformity was dependent on edge size, and could lead to slight underestimation of LFD. Nevertheless, this negative effect could be minimized by using an edge of or larger. An edge composed of lead is susceptible to L‐fluorescence, which causes overestimation of the LFD. The results of this work are intended to underline the need for clear guidelines if the MTF is to be given a more crucial role in acceptance tests and routine assessment of digital mammography systems: the MTF algorithm and edge object test tool need to be publicly validated.