SDSherry L. Dixon

Sherry L. Dixon

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sherry L. Dixon has a total of 35 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Replacing Windows Reduces Childhood Lead Exposure: Results From a State-Funded Program

    by David E. PhD Jacobs, Matthew Tobin, Loreen Targos, Dale Bs Clarkson, Sherry L. Dixon, Jill Mhs Breysse, Preethi Pratap, Salvatore Mph Cali

    Context: Despite considerable evidence that window replacement reduces childhood lead exposure and improves energy conservation and market value, federal policies in childhood lead poisoning, home improvement, and weatherization programs all tend to discourage it. Objective and Intervention: To evaluate a state bond-financed pilot program that replaced old lead-contaminated windows with new lead-free energy efficient ones. Design and Setting: Pre-/post evaluation in 1 urban and 1 rural jurisdiction. Participants: Low-income households (n = 96). Main Outcome Measures: Dust wipe sampling, visual assessment, and physical and mental self-reported health at baseline and 1 year. Results: Geometric mean lead dust (PbD) from baseline to 1 year for interior floors, interior sills, and exterior troughs declined by 44%, 88%, and 98%, respectively (P < .001); 1 year later, levels remained well below baseline but rose slightly compared with clearance sampling just after intervention. PbD declined significantly on both sills and troughs in both the urban and rural jurisdictions from baseline to 1 year. On interior floors, PbD significantly declined by 58% (P = .003) in the rural area and 25% (P = .38) in the urban area, where the decline did not reach statistical significance. Households reported improvements in uncomfortable indoor temperatures (P < .001) and certain health outcomes. Economic benefits were estimated at $5 912 219 compared with a cost of $3 451 841, resulting in a net monetary benefit of $2 460 378. Residents reported that they were “very satisfied” with the window replacement work (87%). Conclusion: Local and state governments should fund and operate window replacement programs to eliminate a major source of childhood lead exposure, improve energy bills, increase home market value, and create local construction and industrial jobs. Federal agencies should encourage (not discourage) replacement of old windows contaminated with lead. In budget climates such as Illinois with reduced public expenditures, making wise investments such as lead-safe window replacement is more important than ever.


  • An investigation into porch dust lead levels

    by Jonathan Wilson, Sherry L. Dixon, David E. Jacobs, Judith Akoto, Katrina S. Korfmacher, Jill Breysse


    • 1 March 2014
      • Vol. 76  (7) , 8

    Health and housing outcomes from green renovation of low-income housing in Washington, DC.

    by David E Jacobs, Jill Breysse, Sherry L Dixon, Susan Aceti, Carol Kawecki, Mark James, Jay Wilson

    Green building systems have proliferated recently, but studies are limited of associated health and housing outcomes. The authors measured self-reported resident physical and mental health, allergens, and building conditions at baseline and one-year follow-up in a low-income housing development being renovated in accordance with green healthy housing improvements (Enterprise Green Communities standards and Leadership in Energy & Environmental Design [LEED] gold certification). Self-reported general health in adults significantly improved from 59% to 67% (p = .026), with large statistically significant improvements in water/ dampness problems, cockroaches and rodents, and reduced pesticide use. Median cockroach (Bla g1) and mouse (Mus m1) allergen dust loadings showed large and statistically significant reductions from baseline to three months postintervention and were sustained at one year (both p < .05). Energy and water cost savings were 16% and 54%, respectively. Incorporating Enterprise Green Communities and LEED standards in low-income housing renovation improves health and housing conditions and can help to reduce disparities. All green housing standards should include health-related requirements.


  • Window replacement and residential lead paint hazard control 12 years later

    by Sherry L. Dixon, David E. Jacobs, Jonathan W. Wilson, Judith Y. Akoto, Rick Nevin, C. Scott Clark


  • Evaluation of Fire-Safety Programs that use 10-Year Smoke Alarms

    by Mark Jackson, Jonathan Wilson, Judith Akoto, Sherry Dixon, David E. Jacobs, Michael F. Ballesteros

    The Centers for Disease Control and Prevention began funding a Smoke Alarm Installation and Fire Safety Education (SAIFE) program in 1998. This program involves the installation of lithium-powered “10-year” smoke alarms in homes at high risk for fires and injuries. This study aimed to (1) determine among original SAIFE homes if the lithium-powered alarms were still present and functional 8–10 years after installation and (2) understand factors related to smoke alarm presence and functionality. Data on a total of 384 homes and 601 smoke alarms in five states were collected and analyzed. Only one-third of alarms were still functional; 37% of installed alarms were missing; and 30% of alarms were present, but not functioning. Alarms were less likely to be functioning if they were installed in the kitchen and if homes had a different resident at follow-up. Of the 351 alarms that were present and had a battery at the time of the evaluation, only 21% contained lithium-powered batteries. Of these, 78% were still functioning. Programs that install lithium-powered alarms should use units that have sealed-in batteries and “hush” buttons. Additionally, education should be given on smoke alarm maintenance that includes a message that batteries in these alarms should not be replaced. Lithium-powered smoke alarms should last up to 10 years if maintained properly.


  • Open Access

    Exposure of U.S. Children to Residential Dust Lead, 1999–2004: II. The Contribution of Lead-Contaminated Dust to Children’s Blood Lead Levels

    by Sherry L. Dixon, Joanna M. Gaitens, David E. Jacobs, Warren Strauss, Jyothi Nagaraja, Tim Pivetz, Jonathan W. Wilson, Peter J. Ashley

    A peer-reviewed open access journal published by the National Institute of Environmental Health Sciences


  • Open Access

    Exposure of U.S. Children to Residential Dust Lead, 1999–2004: I. Housing and Demographic Factors

    by Joanna M. Gaitens, Sherry L. Dixon, David E. Jacobs, Jyothi Nagaraja, Warren Strauss, Jonathan W. Wilson, Peter J. Ashley

    Background: Lead-contaminated house dust is a major source of lead exposure for children in the United States. In 1999–2004, the National Health and Nutrition Examination Survey (NHANES) collected dust lead (PbD) loading samples from the homes of children 12–60 months of age. Objectives: In this study we aimed to compare national PbD levels with existing health-based standards and to identify housing and demographic factors associated with floor and windowsill PbD. Methods: We used NHANES PbD data (n = 2,065 from floors and n = 1,618 from windowsills) and covariates to construct linear and logistic regression models. Results: The population-weighted geometric mean floor and windowsill PbD were 0.5 μg/ft2 [geometric standard error (GSE) = 1.0] and 7.6 μg/ft2 (GSE = 1.0), respectively. Only 0.16% of the floors and 4.0% of the sills had PbD at or above current federal standards of 40 and 250 μg/ft2, respectively. Income, race/ethnicity, floor surface/condition, windowsill PbD, year of construction, recent renovation, smoking, and survey year were significant predictors of floor PbD [the proportion of variability in the dependent variable accounted for by the model (R2) = 35%]. A similar set of predictors plus the presence of large areas of exterior deteriorated paint in pre-1950 homes and the presence of interior deteriorated paint explained 20% of the variability in sill PbD. A companion article [Dixon et al. Environ Health Perspect 117:468–474 (2009)] describes the relationship between children’s blood lead and PbD. Conclusion: Most houses with children have PbD levels that comply with federal standards but may put children at risk. Factors associated with PbD in our population-based models are primarily the same as factors identified in smaller at-risk cohorts. PbD on floors and windowsills should be kept as low as possible to protect children.


  • An examination of interventions to reduce respiratory health and injury hazards in homes of low-income families

    by Sherry L. Dixon, Cecile Fowler, Judy Harris, Sally Moffat, Yolanda Martinez, Heather Walton, Bernice Ruiz, David E. Jacobs


  • Friction and Impact Surfaces: Are They Lead-Based Paint Hazards?

    by Sherry Dixon, Jonathan Wilson, Warren Galke

    Professionals who identify residential lead-based paint hazards and develop lead hazard control plans are instructed to assess painted friction and impact surfaces in homes as potentially active sources of dust lead, a known exposure vector for young children. However, empirical tests of the importance of these surfaces had not been conducted. Using data collected as part of a 1998 three-community study of the Housing and Urban Development Lead Risk Assessment protocols, this article explores how much rubbing or binding on friction and impact surfaces on windows and doors influence dust lead levels on windowsills and floors, while taking into account paint condition on these surfaces and other sources of lead. The analyses included windowsill dust wipe samples from 611 rooms in 182 homes and 782 floor dust wipe samples collected in 209 rooms from 104 homes. The study found that when the paint on windows is intact but the window is rubbing or binding, the dust lead levels on the windowsills are significantly higher than on windows with intact paint without rubbing or binding, after controlling for other lead sources. Windowsill dust lead on a window with intact lead-based paint at 1 mg/cm2 and no rubbing/binding would be 27% lower than on a window with nonintact paint, rubbing/binding surfaces, or both of these conditions. An independent effect of rubbing/binding of doors on floor dust lead loadings was not observed. These findings support federal regulations calling for lead risk assessors to check the friction/impact surfaces at windows when dust lead samples taken below them are elevated, but these analyses did not offer support for taking extra observations of friction/impact surfaces around doors.