Rolf H. Bremmer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Rolf H. Bremmer has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Maurice C. G. Aalders
Biomedical Engineering and Physics Amsterdam UMC, University of Amsterdam Amsterdam Noord‐Holland the Netherlands
5 shared publications - Ton G. van Leeuwen
Amsterdam UMC
4 shared publications Martin J.C. van Gemert
2 shared publications- Annemarie Nadort
Forensic Evidence and Technical Services Command, NSW Police Force
1 shared publication Arjen Amelink
Center for Optical Diagnostics and Therapy, Department of Radiation Oncology,Erasmus Medical Center, Rotterdam, The Netherlands
1 shared publicationDaniel M. de Bruin
Biomedical Engineering and Physics, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
1 shared publication
Latest Publications
- 1 March 2012
- Published by Elsevier in Forensic Science International
- Vol. 216 (1-3) , 1-11
Forensic quest for age determination of bloodstains
- 1 March 2012
- Published by Elsevier in Forensic Science International
- Vol. 216 (1-3) , 1-11
Forensic quest for age determination of bloodstains
- 9 August 2011
- Published by Wiley in Journal of Forensic Sciences
- Vol. 56 (6) , 1471-1475
Remote Spectroscopic Identification of Bloodstains*
Abstract: Blood detection and identification at crime scenes are crucial for harvesting forensic evidence. Unfortunately, most tests for the identification of blood are destructive and time consuming. We present a fast and nondestructive identification test for blood, using noncontact reflectance spectroscopy. We fitted reflectance spectra of 40 bloodstains and 35 nonbloodstains deposited on white cotton with spectroscopic features of the main compounds of blood. Each bloodstain was measured 30 times to account for aging effects. The outcome of the blood measurements was compared with the reflectance of blood‐mimicking stains and various body fluids. We found that discrimination between blood and nonblood deposited on white cotton is possible with a specificity of 100% and a sensitivity of 98%. In conclusion, a goodness of fit between the sample’s reflectance and the blood component fit may allow identification of blood at crime scenes by remote spectroscopy.
- 9 August 2011
- Published by Wiley in Journal of Forensic Sciences
- Vol. 56 (6) , 1471-1475
Remote Spectroscopic Identification of Bloodstains*
Abstract: Blood detection and identification at crime scenes are crucial for harvesting forensic evidence. Unfortunately, most tests for the identification of blood are destructive and time consuming. We present a fast and nondestructive identification test for blood, using noncontact reflectance spectroscopy. We fitted reflectance spectra of 40 bloodstains and 35 nonbloodstains deposited on white cotton with spectroscopic features of the main compounds of blood. Each bloodstain was measured 30 times to account for aging effects. The outcome of the blood measurements was compared with the reflectance of blood‐mimicking stains and various body fluids. We found that discrimination between blood and nonblood deposited on white cotton is possible with a specificity of 100% and a sensitivity of 98%. In conclusion, a goodness of fit between the sample’s reflectance and the blood component fit may allow identification of blood at crime scenes by remote spectroscopy.
- Open Access
- 15 July 2011
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 6 (7) , e21845
Biphasic Oxidation of Oxy-Hemoglobin in Bloodstains
In forensic science, age determination of bloodstains can be crucial in reconstructing crimes. Upon exiting the body, bloodstains transit from bright red to dark brown, which is attributed to oxidation of oxy-hemoglobin (HbO2) to met-hemoglobin (met-Hb) and hemichrome (HC). The fractions of HbO2, met-Hb and HC in a bloodstain can be used for age determination of bloodstains. In this study, we further analyze the conversion of HbO2 to met-Hb and HC, and determine the effect of temperature and humidity on the conversion rates. The fractions of HbO2, met-Hb and HC in a bloodstain, as determined by quantitative analysis of optical reflectance spectra (450–800 nm), were measured as function of age, temperature and humidity. Additionally, Optical Coherence Tomography around 1300 nm was used to confirm quantitative spectral analysis approach. The oxidation rate of HbO2 in bloodstains is biphasic. At first, the oxidation of HbO2 is rapid, but slows down after a few hours. These oxidation rates are strongly temperature dependent. However, the oxidation of HbO2 seems to be independent of humidity, whereas the transition of met-Hb into HC strongly depends on humidity. Knowledge of these decay rates is indispensable for translating laboratory results into forensic practice, and to enable bloodstain age determination on the crime scene.
- 15 July 2011
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 6 (7) , e21845
Open AccessBiphasic Oxidation of Oxy-Hemoglobin in Bloodstains
In forensic science, age determination of bloodstains can be crucial in reconstructing crimes. Upon exiting the body, bloodstains transit from bright red to dark brown, which is attributed to oxidation of oxy-hemoglobin (HbO2) to met-hemoglobin (met-Hb) and hemichrome (HC). The fractions of HbO2, met-Hb and HC in a bloodstain can be used for age determination of bloodstains. In this study, we further analyze the conversion of HbO2 to met-Hb and HC, and determine the effect of temperature and humidity on the conversion rates. The fractions of HbO2, met-Hb and HC in a bloodstain, as determined by quantitative analysis of optical reflectance spectra (450–800 nm), were measured as function of age, temperature and humidity. Additionally, Optical Coherence Tomography around 1300 nm was used to confirm quantitative spectral analysis approach. The oxidation rate of HbO2 in bloodstains is biphasic. At first, the oxidation of HbO2 is rapid, but slows down after a few hours. These oxidation rates are strongly temperature dependent. However, the oxidation of HbO2 seems to be independent of humidity, whereas the transition of met-Hb into HC strongly depends on humidity. Knowledge of these decay rates is indispensable for translating laboratory results into forensic practice, and to enable bloodstain age determination on the crime scene.
- 1 March 2011
- Published by Elsevier in Forensic Science International
- Vol. 206 (1-3) , 166-171
Age estimation of blood stains by hemoglobin derivative determination using reflectance spectroscopy
- 1 March 2011
- Published by Elsevier in Forensic Science International
- Vol. 206 (1-3) , 166-171
Age estimation of blood stains by hemoglobin derivative determination using reflectance spectroscopy
- Open Access
- 24 January 2011
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 2 (2) , 396-407
Non-contact spectroscopic determination of large blood volume fractions in turbid media
We report on a non-contact method to quantitatively determine blood volume fractions in turbid media by reflectance spectroscopy in the VIS/NIR spectral wavelength range. This method will be used for spectral analysis of tissue with large absorption coefficients and assist in age determination of bruises and bloodstains. First, a phantom set was constructed to determine the effective photon path length as a function of μa and μs′ on phantoms with an albedo range: 0.02-0.99. Based on these measurements, an empirical model of the path length was established for phantoms with an albedo > 0.1. Next, this model was validated on whole blood mimicking phantoms, to determine the blood volume fractions ρ = 0.12-0.84 within the phantoms (r = 0.993; error < 10%). Finally, the model was proved applicable on cotton fabric phantoms.
- 24 January 2011
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 2 (2) , 396-407
Open AccessNon-contact spectroscopic determination of large blood volume fractions in turbid media
We report on a non-contact method to quantitatively determine blood volume fractions in turbid media by reflectance spectroscopy in the VIS/NIR spectral wavelength range. This method will be used for spectral analysis of tissue with large absorption coefficients and assist in age determination of bruises and bloodstains. First, a phantom set was constructed to determine the effective photon path length as a function of μa and μs′ on phantoms with an albedo range: 0.02-0.99. Based on these measurements, an empirical model of the path length was established for phantoms with an albedo > 0.1. Next, this model was validated on whole blood mimicking phantoms, to determine the blood volume fractions ρ = 0.12-0.84 within the phantoms (r = 0.993; error < 10%). Finally, the model was proved applicable on cotton fabric phantoms.