Kostadinka Bizheva
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kostadinka Bizheva has a total of 77 co-authors. Here are the top co-authors by number of shared publications:
Alexander Wong
11 shared publicationsBingyao Tan
Department of Physics and Astronomy, University of Waterloo, Waterloo, ON, Canada
9 shared publicationsKeyu Chen
Department of Physics and Astronomy, University of Waterloo, Waterloo, Canada
9 shared publicationsZohreh Hosseinaee
Department of Physics and Astronomy, University of Waterloo, Waterloo, ON, Canada
7 shared publicationsLe Han
University of Waterloo
6 shared publications- Alexander Wong
Department of System Design Engineering, University of Waterloo, Waterloo, ON N2L 3G1, Canada
5 shared publications
Latest Publications
- 23 January 2026
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 17 (2) , 928-946
Longitudinal investigation of prostate tumor spheroid proliferation with dynamic line-field optical coherence tomography
Recently, it has become widely recognized that culturing cancer cells in vitro in small, 3D aggregates known as tumor spheroids provides a more physiologically relevant model of in vivo tumor behavior compared to 2D monolayer cultures. Dynamic optical coherence tomography (dOCT) is a non-invasive imaging modality that, by analyzing temporal fluctuations in the light scattered from biological tissue, does not require exogenous contrast agents to visualize and quantify cellular activity within 3D cell cultures. However, recent volumetric dOCT studies have encountered challenges due to low acquisition speeds. In this study, we present morphological and dynamic analyses of prostate tumor spheroid growth over a two-week longitudinal period, utilizing a line-field dOCT platform. Volumetric dOCT data were acquired for each spheroid in 16 seconds. Our method clearly differentiated between active cellular metabolism in live spheroids and the lack of activity in spheroids fixed with formaldehyde. Quantitative validation of the dynamic signal was conducted using the Alamar Blue proliferation assay, while qualitative validation was provided by live/dead fluorescence microscopy.
- 23 January 2026
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 17 (2) , 928-946
Longitudinal investigation of prostate tumor spheroid proliferation with dynamic line-field optical coherence tomography
Recently, it has become widely recognized that culturing cancer cells in vitro in small, 3D aggregates known as tumor spheroids provides a more physiologically relevant model of in vivo tumor behavior compared to 2D monolayer cultures. Dynamic optical coherence tomography (dOCT) is a non-invasive imaging modality that, by analyzing temporal fluctuations in the light scattered from biological tissue, does not require exogenous contrast agents to visualize and quantify cellular activity within 3D cell cultures. However, recent volumetric dOCT studies have encountered challenges due to low acquisition speeds. In this study, we present morphological and dynamic analyses of prostate tumor spheroid growth over a two-week longitudinal period, utilizing a line-field dOCT platform. Volumetric dOCT data were acquired for each spheroid in 16 seconds. Our method clearly differentiated between active cellular metabolism in live spheroids and the lack of activity in spheroids fixed with formaldehyde. Quantitative validation of the dynamic signal was conducted using the Alamar Blue proliferation assay, while qualitative validation was provided by live/dead fluorescence microscopy.
- 23 December 2025
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 17 (1) , 499-501
Imaging of Tissue and Cell Dynamics: introduction to the feature issue
The guest editors introduce a feature issue on the topic of imaging of tissue and cell dynamics.
- 23 December 2025
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 17 (1) , 499-501
Imaging of Tissue and Cell Dynamics: introduction to the feature issue
The guest editors introduce a feature issue on the topic of imaging of tissue and cell dynamics.
- Open Access
Comparison of volumetric dynamic optical coherence tomography with biological methods for evaluation of radiation effects in prostate tumor spheroids
Significance: 3D tumor spheroids are more physiologically representative of in vivo patient tumors compared to 2D monolayer culture. However, their 3D nature challenges the use of conventional biological techniques like proliferation assays, fluorescence microscopy, and the clonogenic assay, which is the gold standard method for assessing cell survival following radiation. However, clonogenic assay requires spheroid disaggregation. Aim: Non-invasive volumetric imaging with dynamic optical coherence tomography (dOCT) enables cellular activity to be visualized with spatial resolution within 3D tumor spheroids. Cellular activity observed via dOCT in irradiated prostate tumor spheroids was quantified for comparison with conventional biological techniques. Approach: A Varian TrueBeam linear accelerator was used to irradiate spheroid and monolayer cultures with a 6 MV beam. Cellular activity was estimated from dOCT images generated via frequency banding and compared to clonogenic assay, proliferation assay, fluorescence microscopy, and 3D cell simulation. Results: Prostate cancer cells cultured as spheroids demonstrated improved radio-resistance via clonogenic assay compared to monolayer culture. The dOCT method demonstrated quantitative and qualitative agreement with proliferation assay and fluorescence microscopy, respectively. Conclusions: A longer duration of repeated dOCT measurement in tumor spheroids following radiation treatment could offer a non-invasive alternative to the clonogenic assay.
Open AccessComparison of volumetric dynamic optical coherence tomography with biological methods for evaluation of radiation effects in prostate tumor spheroids
Significance: 3D tumor spheroids are more physiologically representative of in vivo patient tumors compared to 2D monolayer culture. However, their 3D nature challenges the use of conventional biological techniques like proliferation assays, fluorescence microscopy, and the clonogenic assay, which is the gold standard method for assessing cell survival following radiation. However, clonogenic assay requires spheroid disaggregation. Aim: Non-invasive volumetric imaging with dynamic optical coherence tomography (dOCT) enables cellular activity to be visualized with spatial resolution within 3D tumor spheroids. Cellular activity observed via dOCT in irradiated prostate tumor spheroids was quantified for comparison with conventional biological techniques. Approach: A Varian TrueBeam linear accelerator was used to irradiate spheroid and monolayer cultures with a 6 MV beam. Cellular activity was estimated from dOCT images generated via frequency banding and compared to clonogenic assay, proliferation assay, fluorescence microscopy, and 3D cell simulation. Results: Prostate cancer cells cultured as spheroids demonstrated improved radio-resistance via clonogenic assay compared to monolayer culture. The dOCT method demonstrated quantitative and qualitative agreement with proliferation assay and fluorescence microscopy, respectively. Conclusions: A longer duration of repeated dOCT measurement in tumor spheroids following radiation treatment could offer a non-invasive alternative to the clonogenic assay.
- Open Access
Longitudinal investigation of prostate tumor spheroid proliferation with dynamic line-field optical coherence tomography
Recently, it has become widely recognized that culturing cancer cells in vitro in small, 3D aggregates known as tumor spheroids provides a more physiologically relevant model of in vivo tumor behavior compared to 2D monolayer cultures. Dynamic optical coherence tomography (dOCT) is a non-invasive imaging modality that, by analyzing temporal fluctuations in the light scattered from biological tissue, does not require exogenous contrast agents to visualize and quantify cellular activity within 3D cell cultures. However, recent volumetric dOCT studies have encountered challenges due to low acquisition speeds. In this study, we present morphological and dynamic analyses of prostate tumor spheroid growth over a two-week longitudinal period, utilizing volumetric imaging with a line-field dOCT platform. Our method clearly differentiated between active cellular metabolism in live spheroids and the lack of activity in spheroids fixed with formaldehyde. Quantitative validation of the dynamic signal was conducted using the Alamar Blue proliferation assay, while qualitative validation was provided by live/dead fluorescence microscopy.
Open AccessLongitudinal investigation of prostate tumor spheroid proliferation with dynamic line-field optical coherence tomography
Recently, it has become widely recognized that culturing cancer cells in vitro in small, 3D aggregates known as tumor spheroids provides a more physiologically relevant model of in vivo tumor behavior compared to 2D monolayer cultures. Dynamic optical coherence tomography (dOCT) is a non-invasive imaging modality that, by analyzing temporal fluctuations in the light scattered from biological tissue, does not require exogenous contrast agents to visualize and quantify cellular activity within 3D cell cultures. However, recent volumetric dOCT studies have encountered challenges due to low acquisition speeds. In this study, we present morphological and dynamic analyses of prostate tumor spheroid growth over a two-week longitudinal period, utilizing volumetric imaging with a line-field dOCT platform. Our method clearly differentiated between active cellular metabolism in live spheroids and the lack of activity in spheroids fixed with formaldehyde. Quantitative validation of the dynamic signal was conducted using the Alamar Blue proliferation assay, while qualitative validation was provided by live/dead fluorescence microscopy.
- 5 September 2025
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 16 (10) , 3958-3976
Visual stimulus-evoked transient blood flow and blood vessel diameter changes in the healthy human retina measured with a combined OCT+ERG system
Neurodegenerative retinal diseases, such as glaucoma, age-related macular degeneration and diabetic retinopathy, cause gradual damage to the retinal morphology, blood vasculature, and neuronal function, and ultimately lead to blindness. In this study, a retinal OCT system was combined with a clinical electroretinography (ERG) system to investigate visually-evoked transient changes in the retinal blood flow (RBF) and blood vessel diameter (BVD) in the healthy human retina. The OCT system offered 2.7 µm axial resolution in retinal tissue and 98 dB sensitivity for 1.1 mW imaging power and 250 kHz image acquisition rate. Doppler OCT (double circular scans around the optic nerve head) and ERG traces were acquired from healthy subjects in response to 10 Hz, white light flicker stimuli and different stimulus intensities. The ERG system was used to generate visual stimuli of precise timing, duration, luminance, and flicker frequency, as well as to confirm the retinal neuronal response to the visual stimulation. MATLAB-based custom algorithms were developed to track time-dependent changes in the RBF and BVD from the OCT images. Results from this study revealed a rapid transient increase in the RBF accompanied by transient vasoconstriction and vasodilation of the retinal blood vessels in response to the flicker stimulation. The amplitude and latency of the RBF and BVD responses were dependent on the stimulus intensity as well as the blood vessel type (arteries or veins).
- 5 September 2025
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 16 (10) , 3958-3976
Visual stimulus-evoked transient blood flow and blood vessel diameter changes in the healthy human retina measured with a combined OCT+ERG system
Neurodegenerative retinal diseases, such as glaucoma, age-related macular degeneration and diabetic retinopathy, cause gradual damage to the retinal morphology, blood vasculature, and neuronal function, and ultimately lead to blindness. In this study, a retinal OCT system was combined with a clinical electroretinography (ERG) system to investigate visually-evoked transient changes in the retinal blood flow (RBF) and blood vessel diameter (BVD) in the healthy human retina. The OCT system offered 2.7 µm axial resolution in retinal tissue and 98 dB sensitivity for 1.1 mW imaging power and 250 kHz image acquisition rate. Doppler OCT (double circular scans around the optic nerve head) and ERG traces were acquired from healthy subjects in response to 10 Hz, white light flicker stimuli and different stimulus intensities. The ERG system was used to generate visual stimuli of precise timing, duration, luminance, and flicker frequency, as well as to confirm the retinal neuronal response to the visual stimulation. MATLAB-based custom algorithms were developed to track time-dependent changes in the RBF and BVD from the OCT images. Results from this study revealed a rapid transient increase in the RBF accompanied by transient vasoconstriction and vasodilation of the retinal blood vessels in response to the flicker stimulation. The amplitude and latency of the RBF and BVD responses were dependent on the stimulus intensity as well as the blood vessel type (arteries or veins).
- Open Access
- 1 July 2025
- Published by SPIE-Intl Soc Optical Eng in Neurophotonics
- Vol. 12 (03) , 035004-16
Combined optical coherence tomography and electroretinography system for imaging neurovascular coupling in the human retina
The retina, often called “the window to the brain,” is an extension of the central nervous system (CNS) designed for the detection of visual information and its transmission to the visual cortex of the brain.1 Highly specialized retinal neurons, such as photoreceptors which detect light and filter it by spectral content; bipolar and horizontal cells which filter the photoreceptor responses spatially and temporally; and ganglion cells that amplify the visual information and transmit it to the brain, are organized in well-defined layers.2 – 5 Furthermore, the retina is highly vascularized with oxygen and nutrition delivered to the retinal neurons in the anterior retina by the inner retina vasculature and to photoreceptors by the choroidal vasculature.6,7 Neurovascular coupling in the retina is referred to as a temporary increase in the retinal blood flow and vasodilation of the retinal blood vessels in response to the increased metabolic demand of retinal neurons. This phenomenon was first observed in the brain8 and later in the retina9,10 using non-invasive optical imaging methods.
- 1 July 2025
- Published by SPIE-Intl Soc Optical Eng in Neurophotonics
- Vol. 12 (03) , 035004-16
Open AccessCombined optical coherence tomography and electroretinography system for imaging neurovascular coupling in the human retina
The retina, often called “the window to the brain,” is an extension of the central nervous system (CNS) designed for the detection of visual information and its transmission to the visual cortex of the brain.1 Highly specialized retinal neurons, such as photoreceptors which detect light and filter it by spectral content; bipolar and horizontal cells which filter the photoreceptor responses spatially and temporally; and ganglion cells that amplify the visual information and transmit it to the brain, are organized in well-defined layers.2 – 5 Furthermore, the retina is highly vascularized with oxygen and nutrition delivered to the retinal neurons in the anterior retina by the inner retina vasculature and to photoreceptors by the choroidal vasculature.6,7 Neurovascular coupling in the retina is referred to as a temporary increase in the retinal blood flow and vasodilation of the retinal blood vessels in response to the increased metabolic demand of retinal neurons. This phenomenon was first observed in the brain8 and later in the retina9,10 using non-invasive optical imaging methods.
- Open Access
- 5 May 2025
- Published by Optica Publishing Group in Optica Open
Visual stimulus-evoked transient blood flow and blood vessel diameter changes in the healthy human retina measured with a combined OCT+ERG system
Neurodegenerative retinal diseases, such as glaucoma, age-related macular degeneration, and diabetic retinopathy, cause gradual damage to the retinal morphology, blood vasculature and neuronal function, and ultimately lead to blindness. In this study, a retinal OCT system was combined with a clinical electroretinography (ERG) system to investigate visually-evoked transient changes in the retinal blood flow (RBF) and blood vessel diameter (BVD) in the healthy human retina. The OCT system offered 2.7 𝜇m axial resolution in retinal tissue and 98 dB sensitivity for 1.1 mW imaging power and 250 kHz image acquisition rate. Doppler OCT (circular scans around the optic nerve head) and ERG traces were acquired from healthy subjects in response to 10 Hz white light flicker stimuli and different stimulus intensities. MATLAB-based custom algorithms were developed for tracking time-dependent changes in the RBF and BVD from the OCT images. Results from this study revealed a rapid transient increase in the RBF accompanied by transient vasoconstriction and vasodilation of the retinal blood vessels in response to the flicker stimulation. The amplitude and latency of the RBF and BVD responses was dependent on the stimulus intensity as well as the blood vessel type (arteries or veins).
- 5 May 2025
- Published by Optica Publishing Group in Optica Open
Open AccessVisual stimulus-evoked transient blood flow and blood vessel diameter changes in the healthy human retina measured with a combined OCT+ERG system
Neurodegenerative retinal diseases, such as glaucoma, age-related macular degeneration, and diabetic retinopathy, cause gradual damage to the retinal morphology, blood vasculature and neuronal function, and ultimately lead to blindness. In this study, a retinal OCT system was combined with a clinical electroretinography (ERG) system to investigate visually-evoked transient changes in the retinal blood flow (RBF) and blood vessel diameter (BVD) in the healthy human retina. The OCT system offered 2.7 𝜇m axial resolution in retinal tissue and 98 dB sensitivity for 1.1 mW imaging power and 250 kHz image acquisition rate. Doppler OCT (circular scans around the optic nerve head) and ERG traces were acquired from healthy subjects in response to 10 Hz white light flicker stimuli and different stimulus intensities. MATLAB-based custom algorithms were developed for tracking time-dependent changes in the RBF and BVD from the OCT images. Results from this study revealed a rapid transient increase in the RBF accompanied by transient vasoconstriction and vasodilation of the retinal blood vessels in response to the flicker stimulation. The amplitude and latency of the RBF and BVD responses was dependent on the stimulus intensity as well as the blood vessel type (arteries or veins).
- Open Access
- 5 May 2025
- Published by Optica Publishing Group in Optica Open
Visual stimulus-evoked transient blood flow and blood vessel diameter changes in the healthy human retina measured with a combined OCT+ERG system
Neurodegenerative retinal diseases, such as glaucoma, age-related macular degeneration, and diabetic retinopathy, cause gradual damage to the retinal morphology, blood vasculature and neuronal function, and ultimately lead to blindness. In this study, a retinal OCT system was combined with a clinical electroretinography (ERG) system to investigate visually-evoked transient changes in the retinal blood flow (RBF) and blood vessel diameter (BVD) in the healthy human retina. The OCT system offered 2.7 𝜇m axial resolution in retinal tissue and 98 dB sensitivity for 1.1 mW imaging power and 250 kHz image acquisition rate. Doppler OCT (circular scans around the optic nerve head) and ERG traces were acquired from healthy subjects in response to 10 Hz white light flicker stimuli and different stimulus intensities. MATLAB-based custom algorithms were developed for tracking time-dependent changes in the RBF and BVD from the OCT images. Results from this study revealed a rapid transient increase in the RBF accompanied by transient vasoconstriction and vasodilation of the retinal blood vessels in response to the flicker stimulation. The amplitude and latency of the RBF and BVD responses was dependent on the stimulus intensity as well as the blood vessel type (arteries or veins).
- 5 May 2025
- Published by Optica Publishing Group in Optica Open
Open AccessVisual stimulus-evoked transient blood flow and blood vessel diameter changes in the healthy human retina measured with a combined OCT+ERG system
Neurodegenerative retinal diseases, such as glaucoma, age-related macular degeneration, and diabetic retinopathy, cause gradual damage to the retinal morphology, blood vasculature and neuronal function, and ultimately lead to blindness. In this study, a retinal OCT system was combined with a clinical electroretinography (ERG) system to investigate visually-evoked transient changes in the retinal blood flow (RBF) and blood vessel diameter (BVD) in the healthy human retina. The OCT system offered 2.7 𝜇m axial resolution in retinal tissue and 98 dB sensitivity for 1.1 mW imaging power and 250 kHz image acquisition rate. Doppler OCT (circular scans around the optic nerve head) and ERG traces were acquired from healthy subjects in response to 10 Hz white light flicker stimuli and different stimulus intensities. MATLAB-based custom algorithms were developed for tracking time-dependent changes in the RBF and BVD from the OCT images. Results from this study revealed a rapid transient increase in the RBF accompanied by transient vasoconstriction and vasodilation of the retinal blood vessels in response to the flicker stimulation. The amplitude and latency of the RBF and BVD responses was dependent on the stimulus intensity as well as the blood vessel type (arteries or veins).
- 1 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (10) , 2937-2946
A Physics-Informed Diffusion Model for Super-Resolved Reconstruction of Optical Coherence Tomography Data
Objective: This study introduces a physics-informed diffusion model (PIDM) for super-resolution (SR) reconstruction of optical coherence tomography (OCT) data. Methods: An optimization framework was developed for maximizing the likelihood of observing an OCT image in the dataset, given the super-resolved reconstruction from a physics-informed diffusion model (PIDM) that reverses the degradations in OCT images. The image degradations were modeled as a serialization of three processes accounting for the effects of defocus, speckle noise, and digital sampling in OCT images. An analytical model for light-propagation model and a statistical model for speckle noise were derived based on the physical properties of the OCT setup. These models were then integrated with a diffusion model to reverse the degradations caused by defocus blur and digital sampling, minimizing susceptibility to noise and defocus-induced artifacts. Results: The proposed method was employed for reconstructing images of a standard resolution target, plant tissue, and in vivo human cornea, using the complex OCT data acquired with a line-scan OCT (LS-OCT) system. The results from the PIDM exhibit improved sharpness and contrast compared to the images resulting from a few baseline methods such as standalone super-resolution using DM. Conclusion: Complementing DM with the physics of OCT could be a viable solution for obtaining high-fidelity SR reconstruction of OCT images. Significance: This work harnesses the power of diffusion models for super-resolution in OCT images. Such development could potentially enhance cellular-resolution OCT imaging of ophthalmic tissues, where high-fidelity images are crucial for accurate diagnosis.
- 1 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (10) , 2937-2946
A Physics-Informed Diffusion Model for Super-Resolved Reconstruction of Optical Coherence Tomography Data
Objective: This study introduces a physics-informed diffusion model (PIDM) for super-resolution (SR) reconstruction of optical coherence tomography (OCT) data. Methods: An optimization framework was developed for maximizing the likelihood of observing an OCT image in the dataset, given the super-resolved reconstruction from a physics-informed diffusion model (PIDM) that reverses the degradations in OCT images. The image degradations were modeled as a serialization of three processes accounting for the effects of defocus, speckle noise, and digital sampling in OCT images. An analytical model for light-propagation model and a statistical model for speckle noise were derived based on the physical properties of the OCT setup. These models were then integrated with a diffusion model to reverse the degradations caused by defocus blur and digital sampling, minimizing susceptibility to noise and defocus-induced artifacts. Results: The proposed method was employed for reconstructing images of a standard resolution target, plant tissue, and in vivo human cornea, using the complex OCT data acquired with a line-scan OCT (LS-OCT) system. The results from the PIDM exhibit improved sharpness and contrast compared to the images resulting from a few baseline methods such as standalone super-resolution using DM. Conclusion: Complementing DM with the physics of OCT could be a viable solution for obtaining high-fidelity SR reconstruction of OCT images. Significance: This work harnesses the power of diffusion models for super-resolution in OCT images. Such development could potentially enhance cellular-resolution OCT imaging of ophthalmic tissues, where high-fidelity images are crucial for accurate diagnosis.
- Open Access
- 2 December 2024
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Translational Vision Science & Technology
- Vol. 13 (12) , 29
In Vivo Contactless, Cellular-Resolution Imaging of the Healthy and Pathological Human Limbus With 250-kHz Point-Scanning SD-OCT
Purpose: To demonstrate that high-seed, ultra–high-resolution spectral-domain optical coherence tomography (SD-OCT) technology can image in vivo fine morphological features in the healthy and pathological human limbus. Methods: A compact, fiberoptic SD-OCT system was developed for imaging the human limbus. It combines ∼1.5-µm isotropic spatial resolution in ocular tissue and an acquisition rate of 250,000 A-scans per second. The imaging probe was outfitted with two microscope objectives to provide flexibility in the choice of wide field of view and extended depth of focus versus high lateral resolution. The clinical potential of the system was evaluated by imaging subjects with limbal stem cell dysfunction (LSCD; n = 4) and healthy controls (n = 6). Results: Limbus images acquired from the healthy controls showed normal cellular structure of the limbal crypts, palisades of Vogt (POVs), and vasculature of the underlying scleral tissue. Images acquired from the LSCD subjects showed distortions or absence of POVs, invasion of highly scattering conjunctival tissue over the limbal and peripheral corneal epithelium, scarring and thinning of the limbal epithelium, and neovascularization. Conclusions: The combination of high OCT spatial resolution and rapid image acquisition rate allows for in vivo, contactless, volumetric visualization of fine morphological details that could be beneficial for the precise diagnosis and grading of LSCD, planning of treatment, and evaluation of the effectiveness of the treatment approaches. Translational Relevance: The OCT technology described here could improve the clinical diagnostics and grading of LSCD, preoperative planning, and postoperative evaluation of LSCD subjects, in addition to monitoring the effectiveness of various LSCD treatments.
- 2 December 2024
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Translational Vision Science & Technology
- Vol. 13 (12) , 29
Open AccessIn Vivo Contactless, Cellular-Resolution Imaging of the Healthy and Pathological Human Limbus With 250-kHz Point-Scanning SD-OCT
Purpose: To demonstrate that high-seed, ultra–high-resolution spectral-domain optical coherence tomography (SD-OCT) technology can image in vivo fine morphological features in the healthy and pathological human limbus. Methods: A compact, fiberoptic SD-OCT system was developed for imaging the human limbus. It combines ∼1.5-µm isotropic spatial resolution in ocular tissue and an acquisition rate of 250,000 A-scans per second. The imaging probe was outfitted with two microscope objectives to provide flexibility in the choice of wide field of view and extended depth of focus versus high lateral resolution. The clinical potential of the system was evaluated by imaging subjects with limbal stem cell dysfunction (LSCD; n = 4) and healthy controls (n = 6). Results: Limbus images acquired from the healthy controls showed normal cellular structure of the limbal crypts, palisades of Vogt (POVs), and vasculature of the underlying scleral tissue. Images acquired from the LSCD subjects showed distortions or absence of POVs, invasion of highly scattering conjunctival tissue over the limbal and peripheral corneal epithelium, scarring and thinning of the limbal epithelium, and neovascularization. Conclusions: The combination of high OCT spatial resolution and rapid image acquisition rate allows for in vivo, contactless, volumetric visualization of fine morphological details that could be beneficial for the precise diagnosis and grading of LSCD, planning of treatment, and evaluation of the effectiveness of the treatment approaches. Translational Relevance: The OCT technology described here could improve the clinical diagnostics and grading of LSCD, preoperative planning, and postoperative evaluation of LSCD subjects, in addition to monitoring the effectiveness of various LSCD treatments.