GZGiovanni Zaccanti

Giovanni Zaccanti

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Giovanni Zaccanti has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Carbon nanohorn-based nanofluids: characterization of the spectral scattering albedo

    by Luca Mercatelli, Elisa Sani, Annalisa Giannini, Paola Di Ninni, Fabrizio Martelli, Giovanni Zaccanti

    The full characterization of the optical properties of nanofluids consisting of single-wall carbon nanohorns of different morphologies in aqueous suspensions is carried out using a novel spectrophotometric technique. Information on the nanofluid scattering and absorption spectral characteristics is obtained by analyzing the data within the single scattering theory and validating the method by comparison with previous monochromatic measurements performed with a different technique. The high absorption coefficient measured joint to the very low scattering albedo opens promising application perspectives for single-wall carbon nanohorn-based fluid or solid suspensions. The proposed approximate approach can be extended also to other low-scattering turbid media. PACS: 78.35.+c Brillouin and Rayleigh scattering, other light scattering; 78.40.Ri absorption and reflection spectra, fullerenes and related materials; 81.05.U- carbon/carbon-based materials; 78.67.Bf optical properties of low-dimensional, mesoscopic, and nanoscale materials and structures, nanocrystals, nanoparticles, and nanoclusters.


  • Open Access

    Effect of dependent scattering on the optical properties of Intralipid tissue phantoms

    by Paola Di Ninni, Fabrizio Martelli, Giovanni Zaccanti

    The calibration of optical tissue-simulating phantoms remains an open question in spite of the many techniques proposed for accurate measurements of optical properties. As a consequence, a reference phantom with well known optical properties is still missing. As a first step towards a reference phantom we have recently proposed to use dilutions of Intralipid 20%. In this paper we discuss a matter that is commonly ignored when dilutions are prepared, i.e., the possibility of deviations from the simple linear relationships between the optical properties of the dilution and the Intralipid concentration due to the effects of dependent scattering. The results of an experimental investigation showed that dependent scattering does not affect absorption. As for the reduced scattering coefficient the effect can be described adding a term proportional to the square of the concentration. However, for concentrations of interest for tissue optics deviations from linearity remain within about 2%. The experimental investigation also showed that the microphysical properties of Intralipid are not affected by dilution. These results show the possibility to easily obtain a liquid diffusive phantom whose optical properties are known with error smaller than about 1%. Due to the intrinsic limitations of the different techniques proposed for measuring the optical properties it seems difficult to obtain a similar accuracy for solid phantoms.


  • Open Access

    Absorption and scattering properties of carbon nanohorn-based nanofluids for direct sunlight absorbers

    by Luca Mercatelli, Elisa Sani, Giovanni Zaccanti, Fabrizio Martelli, Paola Di Ninni, Simona Barison, Cesare Pagura, Filippo Agresti, David Jafrancesco

    In the present work, we investigated the scattering and spectrally resolved absorption properties of nanofluids consisting in aqueous and glycol suspensions of single-wall carbon nanohorns. The characteristics of these nanofluids were evaluated in view of their use as sunlight absorber fluids in a solar device. The observed nanoparticle-induced differences in optical properties appeared promising, leading to a considerably higher sunlight absorption with respect to the pure base fluids. Scattered light was found to be not more than about 5% with respect to the total attenuation of light. Both these effects, together with the possible chemical functionalization of carbon nanohorns, make this new kind of nanofluids very interesting for increasing the overall efficiency of the sunlight exploiting device. PACS 78.40.Ri, 78.35.+c, 78.67.Bf, 88.40.fh, 88.40.fr, 81.05.U.


  • The use of India ink in tissue-simulating phantoms

    by Paola Di Ninni, Fabrizio Martelli, Giovanni Zaccanti

    The optical properties of India ink, an absorber often used in preparation of tissue simulating phantoms, have been investigated at visible and near infrared wavelengths. The extinction coefficient has been obtained from measurements of collimated transmittance and from spectrophotometric measurements, the absorption coefficient from multidistance measurements of fluence rate in a diffusive infinite medium with small concentrations of added ink. Measurements have been carried out on samples of India ink from five different brands, and for some brands also from different batches. As also reported in previously published papers the results we have obtained showed large inter-brand and inter-batch variations for both the absorption and the extinction coefficient. On the contrary, our results showed small variations for the ratio between the absorption and the extinction coefficient. The albedo is therefore similar for all samples: The values averaged over all samples investigated were 0.161, 0.115, and 0.115 at λ = 632.8, 751, and 833 nm respectively, with maximum deviations of 0.044, 0.019, and 0.035. These results indicate that, using the values we have obtained for the albedo, it should be possible to obtain with uncertainty smaller than about 4% the absorption coefficient of a sample of unknown ink from simple measurements of extinction coefficient. A similar accuracy is not easily obtained with the complicated procedures necessary for measurements of absorption coefficient.


  • Functional diffuse reflectance spectroscopy at small source-detector distances based on fast-gated single-photon avalanche diodes

    by Davide Contini, Antonio Pifferi, Lorenzo Spinelli, Alessandro Torricelli, Rinaldo Cubeddu, Fabrizio Martelli, Giovanni Zaccanti, Alberto Dalla Mora, Alberto Tosi, Franco Zappa, et al.

    In this review we present the instrumental and theoretical developments for functional diffuse reflectance spectroscopy at small source-detector distances. We proposed the possibility to perform photon migration measurements at null or small inter-fiber distances demonstrating the improvement of this novel approach in terms of achievable contrast, spatial resolution and number of detected photons. We developed a novel system to perform time-resolved diffuse reflectance measurement at small source detector separation based on a single photon avalanche photodiode (SPAD) operated in fast time gated mode and a broadband fiber laser. By means of time gating it is possible to detect longer lived photons neglecting initial ones. We show results both on homogeneous and inhomogeneous tissue phantoms demonstrating a dynamic range of 7 orders of magnitude and a temporal range of 6 nanoseconds. Furthermore, this approach proved valuable to detect brain activity.


  • Monitoring Absorption Changes in a Layered Diffusive Medium by White-Light Time-Resolved Reflectance Spectroscopy

    by Arianna Giusto, Cosimo D'Andrea, Lorenzo Spinelli, Davide Contini, Alessandro Torricelli, Fabrizio Martelli, Giovanni Zaccanti, Rinaldo Cubeddu

    Diffuse spectroscopy of turbid media has assumed a crucial role in the characterization of biological tissues. In particular, broadband time-resolved optical spectroscopy allows the direct determination in a single measurement of both the optical parameters of the tissue and the concentration of its main constituents. Moreover, the possibility of performing parallel wavelength measurements allows the recording of data in real time, providing a system that is able to perform dynamic measurements. We used a white-light time-resolved spectroscopy system to monitor absorption changes in a layered diffusive medium. Measurements were performed in reflectance geometry, with a 2-cm source-detector distance, on a two-layer liquid phantom with optical properties similar to those of human tissues. By varying the concentrations of three inks with different spectral features, we changed the absorption coefficient of the layers to mimic functional brain activation and the systemic response in the scalp. Data were analyzed by a time-resolved spectrally constrained fitting method based on a homogeneous model of photon diffusion. Although this approach is based on a homogeneous model and employs a single source-detector distance, the technique is able to monitor changes in the lower layer, while it is scarcely affected by variations in the upper layer. These results were confirmed by numerical simulations based on a perturbation approach to diffusion theory. Preliminary in vivo measurements have been performed on healthy volunteers to monitor oxy- and deoxy-hemoglobin changes in the brain during a motor task. Although the overall sensitivity of the technique is reduced, in vivo results are in general agreement with the findings of the dedicated system for functional brain activity.


  • Brain functional imaging at small source-detector distances based on fast-gated single-photon avalanche diodes

    by Lorenzo Spinelli, Davide Contini, Rinaldo Cubeddu, Antonio Pifferi, Alessandro Torricelli, Fabrizio Martelli, Giovanni Zaccanti, Alberto Tosi, Alberto Dalla Mora, Franco Zappa, et al.

    In this work we focused on time-resolved measurements in diffusive media performed at small (few millimeters) source-detector distances in reflectance geometry. This configuration has been predicted to have better contrast, better spatial resolution, and lower noise than the typical measurements performed at few centimeters. In our instrumental set-up we exploited a fast-gating (rise-time < 400 ps) front-end electronics enabling a silicon Single- Photon Avalanche Diode (SPAD) for time-correlated single-photon counting. By means of this detector, we can acquire "late" photons of the diffused light collected 2 mm apart from the injection point. This is possible because the fast gated SPAD rejects the huge amount of "early" photons which otherwise would saturate the detection electronic chain. The time resolution of the set-up is 100 ps. The instrument has been validated on both homogeneous and inhomogeneous (high absorbing inclusion at different depths inside) tissue phantoms with different optical properties. We obtained diffused time-resolved curves with dynamic ranges of about 107. Moreover, we demonstrated good agreement between the measured time-resolved contrasts and those calculated by Monte Carlo numerical simulations.

  • Hybrid Heuristic Time Dependent Solution of the Radiative Transfer Equation for the Slab

    by Fabrizio Martelli, Samuele Del Bianco, Antonio Pifferi, Lorenzo Spinelli, Alessandro Torricelli, Giovanni Zaccanti

    A hybrid heuristic time dependent analytical solution of the radiative transfer equation for the slab geometry is derived. Comparisons with the results of Monte Carlo simulations have shown an excellent behavior of the model in describing photon migration at short distances and early times where the solution of the diffusion equation is subjected to strong approximations.

  • Measurements of optical properties of high-density media

    by Giovanni Zaccanti, Samuele Del Bianco, Fabrizio Martelli

    Measurements of optical properties (scattering coefficient μs, absorption coefficient μa, reduced scattering coefficient μs′, and asymmetry factor g) have been carried out up to a volume particle concentration of ρ = 0.227. The results for μs and μs′ show significant deviations from the linear dependence on ρ as expected when the independent scattering assumption is fulfilled. The asymmetry factor also changed significantly. In contrast, the dependence of μa remained linear even at the largest concentration investigated. The simple linear dependence of absorption on the chromophore concentration expected from the independent scattering assumption is thus applicable also to spectroscopic measurements of dense media. A comparison with an approximate theoretical model based on the Foldy-Twersky equation is also reported. The model provides a good description of the dependence of μs on particle concentration.