Judith R. Mourant
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Judith R. Mourant has a total of 50 co-authors. Here are the top co-authors by number of shared publications:
James P. Freyer
Los Alamos National Laboratory, Los Alamos, New Mexico 87545
5 shared publicationsHarriet O. Smith
Einstein Cancer Center, Department of Obstetrics and Gynecology and Women’s Health, 1695 Eastchester Road, Bronx, New York 10461
4 shared publicationsSusan Carpenter
Los Alamos National Laboratory, Los Alamos, New Mexico 87545
4 shared publicationsTamara M. Powers
Bioscience Division, Los Alamos National Laboratory, PO Box 1663, MS E535, Los Alamos, New Mexico, 87545
4 shared publicationsAlan G. Waxman
General Gynecology Division, Department of Obstetrics and Gynecology, University of New Mexico Health Sciences Center, Albuquerque, NM; and
3 shared publicationsMaxine H. Dorin
General Gynecology Division, Department of Obstetrics and Gynecology, University of New Mexico Health Sciences Center, Albuquerque, NM; and
3 shared publications
Latest Publications
- Open Access
- 3 September 2018
- Published by Frontiers Media SA in Frontiers in Veterinary Science
- Vol. 5, 182
Decision Support for Mitigation of Livestock Disease: Rinderpest as a Case Study
A versatile, interactive model to predict geographically resolved epidemic progression after pathogen introduction into a population is presented. Deterministic simulations incorporating a compartmental disease model run rapidly, facilitating the analysis of mitigations such as vaccination and transmission reduction on epidemic spread and progression. We demonstrate the simulation model using rinderpest infection of cattle, a devastating livestock disease. Rinderpest has been extinguished in the wild, but it is still a threat due to stored virus in some laboratories. Comparison of simulations to historical outbreaks provides some validation of the model. Simulations of potential outbreaks demonstrate potential consequences of rinderpest virus release for a variety of possible disease parameters and mitigations. Our results indicate that a rinderpest outbreak could result in severe social and economic consequences.
- 3 September 2018
- Published by Frontiers Media SA in Frontiers in Veterinary Science
- Vol. 5, 182
Open AccessDecision Support for Mitigation of Livestock Disease: Rinderpest as a Case Study
A versatile, interactive model to predict geographically resolved epidemic progression after pathogen introduction into a population is presented. Deterministic simulations incorporating a compartmental disease model run rapidly, facilitating the analysis of mitigations such as vaccination and transmission reduction on epidemic spread and progression. We demonstrate the simulation model using rinderpest infection of cattle, a devastating livestock disease. Rinderpest has been extinguished in the wild, but it is still a threat due to stored virus in some laboratories. Comparison of simulations to historical outbreaks provides some validation of the model. Simulations of potential outbreaks demonstrate potential consequences of rinderpest virus release for a variety of possible disease parameters and mitigations. Our results indicate that a rinderpest outbreak could result in severe social and economic consequences.
- Open Access
- 1 March 2014
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 19 (3) , 037004
Hemoglobin parameters from diffuse reflectance data
Tissue vasculature is altered when cancer develops. Consequently, noninvasive methods of monitoring blood vessel size, density, and oxygenation would be valuable. Simple spectroscopy employing fiber optic probes to measure backscattering can potentially determine hemoglobin parameters. However, heterogeneity of blood distribution, the dependence of the tissue-volume-sampled on scattering and absorption, and the potential compression of tissue all hinder the accurate determination of hemoglobin parameters. We address each of these issues. A simple derivation of a correction factor for the absorption coefficient, , is presented. This correction factor depends not only on the vessel size, as others have shown, but also on the density of blood vessels. Monte Carlo simulations were used to determine the dependence of an effective pathlength of light through tissue which is parameterized as a ninth-order polynomial function of . The hemoglobin bands of backscattering spectra of cervical tissue are fit using these expressions to obtain effective blood vessel size and density, tissue hemoglobin concentration, and oxygenation. Hemoglobin concentration and vessel density were found to depend on the pressure applied during in vivo acquisition of the spectra. It is also shown that determined vessel size depends on the blood hemoglobin concentration used.- 1 March 2014
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 19 (3) , 037004
Open AccessHemoglobin parameters from diffuse reflectance data
Tissue vasculature is altered when cancer develops. Consequently, noninvasive methods of monitoring blood vessel size, density, and oxygenation would be valuable. Simple spectroscopy employing fiber optic probes to measure backscattering can potentially determine hemoglobin parameters. However, heterogeneity of blood distribution, the dependence of the tissue-volume-sampled on scattering and absorption, and the potential compression of tissue all hinder the accurate determination of hemoglobin parameters. We address each of these issues. A simple derivation of a correction factor for the absorption coefficient, , is presented. This correction factor depends not only on the vessel size, as others have shown, but also on the density of blood vessels. Monte Carlo simulations were used to determine the dependence of an effective pathlength of light through tissue which is parameterized as a ninth-order polynomial function of . The hemoglobin bands of backscattering spectra of cervical tissue are fit using these expressions to obtain effective blood vessel size and density, tissue hemoglobin concentration, and oxygenation. Hemoglobin concentration and vessel density were found to depend on the pressure applied during in vivo acquisition of the spectra. It is also shown that determined vessel size depends on the blood hemoglobin concentration used. - Open Access
- 4 September 2013
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 4 (10) , 1946-1963
Perturbation Monte Carlo methods for tissue structure alterations
This paper describes an extension of the perturbation Monte Carlo method to model light transport when the phase function is arbitrarily perturbed. Current perturbation Monte Carlo methods allow perturbation of both the scattering and absorption coefficients, however, the phase function can not be varied. The more complex method we develop and test here is not limited in this way. We derive a rigorous perturbation Monte Carlo extension that can be applied to a large family of important biomedical light transport problems and demonstrate its greater computational efficiency compared with using conventional Monte Carlo simulations to produce forward transport problem solutions. The gains of the perturbation method occur because only a single baseline Monte Carlo simulation is needed to obtain forward solutions to other closely related problems whose input is described by perturbing one or more parameters from the input of the baseline problem. The new perturbation Monte Carlo methods are tested using tissue light scattering parameters relevant to epithelia where many tumors originate. The tissue model has parameters for the number density and average size of three classes of scatterers; whole nuclei, organelles such as lysosomes and mitochondria, and small particles such as ribosomes or large protein complexes. When these parameters or the wavelength is varied the scattering coefficient and the phase function vary. Perturbation calculations give accurate results over variations of ∼15–25% of the scattering parameters.
- 4 September 2013
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 4 (10) , 1946-1963
Open AccessPerturbation Monte Carlo methods for tissue structure alterations
This paper describes an extension of the perturbation Monte Carlo method to model light transport when the phase function is arbitrarily perturbed. Current perturbation Monte Carlo methods allow perturbation of both the scattering and absorption coefficients, however, the phase function can not be varied. The more complex method we develop and test here is not limited in this way. We derive a rigorous perturbation Monte Carlo extension that can be applied to a large family of important biomedical light transport problems and demonstrate its greater computational efficiency compared with using conventional Monte Carlo simulations to produce forward transport problem solutions. The gains of the perturbation method occur because only a single baseline Monte Carlo simulation is needed to obtain forward solutions to other closely related problems whose input is described by perturbing one or more parameters from the input of the baseline problem. The new perturbation Monte Carlo methods are tested using tissue light scattering parameters relevant to epithelia where many tumors originate. The tissue model has parameters for the number density and average size of three classes of scatterers; whole nuclei, organelles such as lysosomes and mitochondria, and small particles such as ribosomes or large protein complexes. When these parameters or the wavelength is varied the scattering coefficient and the phase function vary. Perturbation calculations give accurate results over variations of ∼15–25% of the scattering parameters.
- Open Access
- 1 August 2012
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 17 (8) , 085002
Effects of acetic acid on light scattering from cells
Acetic acid has been used for decades as an aid for the detection of precancerous cervical lesions, and the use of acetic acid is being investigated in several other tissues. Nonetheless, the mechanism of acetowhitening is unclear. This work tests some of the hypotheses in the literature and measures changes in light scattering specific to the nucleus and the cytoplasm. Wide angle side scattering from both the nucleus and the cytoplasm increases with acetic application to tumorigenic cells, with the increase in nuclear scattering being greater. In one cell line, the changes in nuclear scattering are likely due to an increase in number or scattering efficiency of scattering centers smaller than the wavelength of excitation light. There are likely several cellular changes that cause acetowhitening and the cellular changes may differ with cell type. These results should lead to a better understanding of acetowhitening and potentially the development of adjunct techniques to improve the utility of acetic acid application. For the well-studied case of cervical tissue, acetowhitening has been shown to be sensitive, but not specific for oncogenic changes needing treatment.
- 1 August 2012
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 17 (8) , 085002
Open AccessEffects of acetic acid on light scattering from cells
Acetic acid has been used for decades as an aid for the detection of precancerous cervical lesions, and the use of acetic acid is being investigated in several other tissues. Nonetheless, the mechanism of acetowhitening is unclear. This work tests some of the hypotheses in the literature and measures changes in light scattering specific to the nucleus and the cytoplasm. Wide angle side scattering from both the nucleus and the cytoplasm increases with acetic application to tumorigenic cells, with the increase in nuclear scattering being greater. In one cell line, the changes in nuclear scattering are likely due to an increase in number or scattering efficiency of scattering centers smaller than the wavelength of excitation light. There are likely several cellular changes that cause acetowhitening and the cellular changes may differ with cell type. These results should lead to a better understanding of acetowhitening and potentially the development of adjunct techniques to improve the utility of acetic acid application. For the well-studied case of cervical tissue, acetowhitening has been shown to be sensitive, but not specific for oncogenic changes needing treatment.
- Open Access
- 13 January 2012
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 3 (2) , 296-312
Correlating light scattering with internal cellular structures
The origins of side scattering from a fibroblast and cervical cell line were determined by comparing side-scatter images with images stained for lysosomes, nuclei, and mitochondria on a cell by cell basis. Lysosomes or nuclei are the most efficient type of scatterer depending on the cell type and incident light polarization. The relative scattering efficiencies of lysosomes and mitochondria were the same for both cell lines, while the scattering efficiencies of the nuclei differed. The percent of 90° scattering from the nucleus, mitochondria, and lysosomes as well as the group of other internal cellular objects was estimated. The nucleus was the largest contributor to side scatter in the cervical carcinoma cells. The contributions of lysosomes, mitochondria, the nucleus, and particles unstained by either Hoechst, LysoSensor or MitoTracker ranges from ∼20% to ∼30% in fibroblast cells. The contribution of lysosomes to side scatter was much stronger when the incident light was polarized perpendicular to the scattering plane than when the polarization of the side scatter laser was parallel to the scattering plane. This dependence on side scatter polarization indicates that lysosomes contain scattering structures that are much smaller than the wavelength of light used in the measurements (785 nm). In conclusion, mitochondria were not found to be either the most efficient scatterer or to have the largest contribution to scattering in either cell line, in contrast to previous reports. Rather lysosomes, nuclei and unknown particles all have significant contributions to 90° scattering and the contributions of some of these particles can be modulated by changing the polarization of the incident light.
- 13 January 2012
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 3 (2) , 296-312
Open AccessCorrelating light scattering with internal cellular structures
The origins of side scattering from a fibroblast and cervical cell line were determined by comparing side-scatter images with images stained for lysosomes, nuclei, and mitochondria on a cell by cell basis. Lysosomes or nuclei are the most efficient type of scatterer depending on the cell type and incident light polarization. The relative scattering efficiencies of lysosomes and mitochondria were the same for both cell lines, while the scattering efficiencies of the nuclei differed. The percent of 90° scattering from the nucleus, mitochondria, and lysosomes as well as the group of other internal cellular objects was estimated. The nucleus was the largest contributor to side scatter in the cervical carcinoma cells. The contributions of lysosomes, mitochondria, the nucleus, and particles unstained by either Hoechst, LysoSensor or MitoTracker ranges from ∼20% to ∼30% in fibroblast cells. The contribution of lysosomes to side scatter was much stronger when the incident light was polarized perpendicular to the scattering plane than when the polarization of the side scatter laser was parallel to the scattering plane. This dependence on side scatter polarization indicates that lysosomes contain scattering structures that are much smaller than the wavelength of light used in the measurements (785 nm). In conclusion, mitochondria were not found to be either the most efficient scatterer or to have the largest contribution to scattering in either cell line, in contrast to previous reports. Rather lysosomes, nuclei and unknown particles all have significant contributions to 90° scattering and the contributions of some of these particles can be modulated by changing the polarization of the incident light.
- 1 October 2009
- Published by Wolters Kluwer Health in Journal of Lower Genital Tract Disease
- Vol. 13 (4) , 216-223
Detection of Cervical Intraepithelial Neoplasias and Cancers in Cervical Tissue by In Vivo Light Scattering
Objective. This study aimed to examine the utility of in vivo elastic light scattering measurements, to identify cervical intraepithelial neoplasias 2,3 and cancers in women undergoing colposcopy, and to determine the effects of patient characteristics such as menstrual status on the elastic light scattering spectroscopic measurements. Materials and Methods. A fiber optic probe was used to measure light transport in the cervical epithelium of patients undergoing colposcopy. Spectroscopic results from 151 patients were compared with histopathology of the measured and biopsied sites. A method of classifying the measured sites into 2 clinically relevant categories was developed and tested using 5-fold cross-validation. Results. Statistically significant effects by age at diagnosis, menopausal status, timing of the menstrual cycle, and oral contraceptive use were identified, and adjustments based on these measurements were incorporated in the classification algorithm. A sensitivity of 77% ± 5% and a specificity of 62% ± 2% were obtained for separating cervical intraepithelial neoplasia 2,3 and cancer from other pathologies and normal tissue. Conclusions. The effects of both menstrual status and age should be taken into account in the algorithm for classifying tissue sites based on elastic light scattering spectroscopy. When this is done, elastic light scattering spectroscopy shows good potential for real-time diagnosis of cervical tissue at colposcopy. Guiding biopsy location is one potential near-term clinical application area, whereas facilitating "see and treat" protocols is a longer term goal. Improvements in accuracy are essential.
- 1 October 2009
- Published by Wolters Kluwer Health in Journal of Lower Genital Tract Disease
- Vol. 13 (4) , 216-223
Detection of Cervical Intraepithelial Neoplasias and Cancers in Cervical Tissue by In Vivo Light Scattering
Objective. This study aimed to examine the utility of in vivo elastic light scattering measurements, to identify cervical intraepithelial neoplasias 2,3 and cancers in women undergoing colposcopy, and to determine the effects of patient characteristics such as menstrual status on the elastic light scattering spectroscopic measurements. Materials and Methods. A fiber optic probe was used to measure light transport in the cervical epithelium of patients undergoing colposcopy. Spectroscopic results from 151 patients were compared with histopathology of the measured and biopsied sites. A method of classifying the measured sites into 2 clinically relevant categories was developed and tested using 5-fold cross-validation. Results. Statistically significant effects by age at diagnosis, menopausal status, timing of the menstrual cycle, and oral contraceptive use were identified, and adjustments based on these measurements were incorporated in the classification algorithm. A sensitivity of 77% ± 5% and a specificity of 62% ± 2% were obtained for separating cervical intraepithelial neoplasia 2,3 and cancer from other pathologies and normal tissue. Conclusions. The effects of both menstrual status and age should be taken into account in the algorithm for classifying tissue sites based on elastic light scattering spectroscopy. When this is done, elastic light scattering spectroscopy shows good potential for real-time diagnosis of cervical tissue at colposcopy. Guiding biopsy location is one potential near-term clinical application area, whereas facilitating "see and treat" protocols is a longer term goal. Improvements in accuracy are essential.
- 7 January 2009
- Published by Optica Publishing Group in Applied Optics
- Vol. 48 (10) , D26-D35
In vivo light scattering for the detection of cancerous and precancerous lesions of the cervix
A noninvasive optical diagnostic system for detection of cancerous and precancerous lesions of the cervix was evaluated in vivo. The optical system included a fiber-optic probe designed to measure polarized and unpolarized light transport properties of a small volume of tissue. An algorithm for diagnosing tissue based on the optical measurements was developed that used four optical properties, three of which were related to light scattering properties and the fourth of which was related to hemoglobin concentration. A sensitivity of and specificities in the mid 60% range were obtained for separating high grade squamous intraepithelial lesions and cancer from other pathologies and normal tissue. The use of different cross-validation methods in algorithm development is analyzed, and the relative difficulties of diagnosing certain pathologies are assessed. Furthermore, the robustness of the optical system for use by different doctors and to changes in fiber-optic probe are also assessed, and potential improvements in the optical system are discussed.- 7 January 2009
- Published by Optica Publishing Group in Applied Optics
- Vol. 48 (10) , D26-D35
In vivo light scattering for the detection of cancerous and precancerous lesions of the cervix
A noninvasive optical diagnostic system for detection of cancerous and precancerous lesions of the cervix was evaluated in vivo. The optical system included a fiber-optic probe designed to measure polarized and unpolarized light transport properties of a small volume of tissue. An algorithm for diagnosing tissue based on the optical measurements was developed that used four optical properties, three of which were related to light scattering properties and the fourth of which was related to hemoglobin concentration. A sensitivity of and specificities in the mid 60% range were obtained for separating high grade squamous intraepithelial lesions and cancer from other pathologies and normal tissue. The use of different cross-validation methods in algorithm development is analyzed, and the relative difficulties of diagnosing certain pathologies are assessed. Furthermore, the robustness of the optical system for use by different doctors and to changes in fiber-optic probe are also assessed, and potential improvements in the optical system are discussed.- 1 May 2007
- Published by Elsevier in Gynecologic Oncology
- Vol. 105 (2) , 439-445
In vivo light scattering measurements for detection of precancerous conditions of the cervix
- 1 May 2007
- Published by Elsevier in Gynecologic Oncology
- Vol. 105 (2) , 439-445
In vivo light scattering measurements for detection of precancerous conditions of the cervix
- Open Access
- 1 January 2006
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 11 (6) , 064024-064024-11
Comparison of vibrational spectroscopy to biochemical and flow cytometry methods for analysis of the basic biochemical composition of mammalian cells
We have conducted an extensive comparison of cellular biochemical composition obtained from infrared and Raman spectra of intact cells with measurements using standard extraction and chemical analysis (including NMR), and flow cytometric assay on fixed cells. Measurements were conducted on a rat fibroblast carcinogenesis model consisting of normal and tumorigenic cells assayed as exponentially growing and plateau-phase cultures. Estimates of protein, DNA, RNA, lipids, and glycogen amounts were obtained from a previous publication in which vibrational spectra were fit to a set of basis spectra representing protein, DNA, RNA, lipids, and glycogen. The Raman spectral estimates of absolute cellular composition were quite similar to the independent biochemical and flow cytometric assays. The infrared spectra gave similar results for protein, lipid, and glycogen but underestimated the DNA content while overestimating the RNA level. When ratios of biochemical concentrations in exponential and plateau-phase cultures were examined, the Raman spectroscopic results were the same, within errors, as the independent methods, in all cases. Several changes in relative biochemical composition due to tumorigenic and proliferative status previously reported using vibrational spectroscopy were confirmed by the independent methods. These results demonstrate that vibrational spectroscopy can provide reliable estimates of the biochemical composition of mammalian cells.
- 1 January 2006
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 11 (6) , 064024-064024-11
Open AccessComparison of vibrational spectroscopy to biochemical and flow cytometry methods for analysis of the basic biochemical composition of mammalian cells
We have conducted an extensive comparison of cellular biochemical composition obtained from infrared and Raman spectra of intact cells with measurements using standard extraction and chemical analysis (including NMR), and flow cytometric assay on fixed cells. Measurements were conducted on a rat fibroblast carcinogenesis model consisting of normal and tumorigenic cells assayed as exponentially growing and plateau-phase cultures. Estimates of protein, DNA, RNA, lipids, and glycogen amounts were obtained from a previous publication in which vibrational spectra were fit to a set of basis spectra representing protein, DNA, RNA, lipids, and glycogen. The Raman spectral estimates of absolute cellular composition were quite similar to the independent biochemical and flow cytometric assays. The infrared spectra gave similar results for protein, lipid, and glycogen but underestimated the DNA content while overestimating the RNA level. When ratios of biochemical concentrations in exponential and plateau-phase cultures were examined, the Raman spectroscopic results were the same, within errors, as the independent methods, in all cases. Several changes in relative biochemical composition due to tumorigenic and proliferative status previously reported using vibrational spectroscopy were confirmed by the independent methods. These results demonstrate that vibrational spectroscopy can provide reliable estimates of the biochemical composition of mammalian cells.
- 1 January 2006
- Published by Optica Publishing Group
- p. SP5
Broadband monitoring of physiological changes with a continuous light tissue spectrometer
A broadband (300-900 nm), continuous wave spectrometer was developed for measuring diffuse-backscattered light in tissue, and its sensitivity to physiological changes was demonstrated.
- 1 January 2006
- Published by Optica Publishing Group
- p. SP5
Broadband monitoring of physiological changes with a continuous light tissue spectrometer
A broadband (300-900 nm), continuous wave spectrometer was developed for measuring diffuse-backscattered light in tissue, and its sensitivity to physiological changes was demonstrated.