Markus W. Sigrist
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Markus W. Sigrist has a total of 71 co-authors. Here are the top co-authors by number of shared publications:
D. Marinov
ETH Zurich, Institute of Quantum Electronics, Schafmattstr. 16, CH-8093 Zurich, Switzerland
3 shared publicationsMichael Seiter
3 shared publicationsC. Fischer
ETH Zurich
2 shared publications- Cornelia Fischer
Swiss Federal Institute of Technology Zurich (Switzerland)
2 shared publications D. Keller
Swiss Federal Institute of Technology (ETH), Institute of Quantum Electronics, CH-8093 Zürich, Switzerland (Fax: +41-1/633-1077
2 shared publicationsD.E. Vogler
Institute of Quantum Electronics, ETH Zurich, Zurich, Switzerland
2 shared publications
Latest Publications
- 27 January 2017
- Published by SPIE-Intl Soc Optical Eng
- p. 1011136-1011136-7
Filter-free measurements of black carbon absorption using photoacoustic spectroscopy
- 27 January 2017
- Published by SPIE-Intl Soc Optical Eng
- p. 1011136-1011136-7
Filter-free measurements of black carbon absorption using photoacoustic spectroscopy
- Open Access
Mid-Infrared Fiber-Coupled Photoacoustic Sensor for Biomedical Applications
Biomedical devices employed in therapy, diagnostics and for self-monitoring often require a high degree of flexibility and compactness. Many near infrared (NIR) optical fiber-coupled systems meet these requirements and are employed on a daily basis. However, mid-infrared (MIR) fibers-based systems have not yet found their way to routine application in medicine. In this work we present the implementation of the first MIR fiber-coupled photoacoustic sensor for the investigation of condensed samples in the MIR fingerprint region. The light of an external-cavity quantum-cascade laser (1010–1095 cm-1) is delivered by a silver halide fiber, which is attached to the PA cell. The PA chamber is conically shaped to perfectly match the beam escaping the fiber and to minimize the cell volume. This results in a compact and handy sensor for investigations of biological samples and the monitoring of constituents both in vitro and in vivo. The performance of the fiber-coupled PA sensor is demonstrated by sensing glucose in aqueous solutions. These measurements yield a detection limit of 57 mg/dL (SNR = 1). Furthermore, the fiber-coupled sensor has been applied to record human skin spectra at different body sites to illustrate its flexibility.
Open AccessMid-Infrared Fiber-Coupled Photoacoustic Sensor for Biomedical Applications
Biomedical devices employed in therapy, diagnostics and for self-monitoring often require a high degree of flexibility and compactness. Many near infrared (NIR) optical fiber-coupled systems meet these requirements and are employed on a daily basis. However, mid-infrared (MIR) fibers-based systems have not yet found their way to routine application in medicine. In this work we present the implementation of the first MIR fiber-coupled photoacoustic sensor for the investigation of condensed samples in the MIR fingerprint region. The light of an external-cavity quantum-cascade laser (1010–1095 cm-1) is delivered by a silver halide fiber, which is attached to the PA cell. The PA chamber is conically shaped to perfectly match the beam escaping the fiber and to minimize the cell volume. This results in a compact and handy sensor for investigations of biological samples and the monitoring of constituents both in vitro and in vivo. The performance of the fiber-coupled PA sensor is demonstrated by sensing glucose in aqueous solutions. These measurements yield a detection limit of 57 mg/dL (SNR = 1). Furthermore, the fiber-coupled sensor has been applied to record human skin spectra at different body sites to illustrate its flexibility.
- Open Access
- 1 March 2012
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 3 (4) , 667-680
Glucose sensing in human epidermis using mid-infrared photoacoustic detection
No reliable non-invasive glucose monitoring devices are currently available. We implemented a mid-infrared (MIR) photoacoustic (PA) setup to track glucose in vitro in deep epidermal layers, which represents a significant step towards non-invasive in vivo glucose measurements using MIR light. An external-cavity quantum-cascade laser (1010–1095 cm−1) and a PA cell of only 78 mm3 volume were employed to monitor glucose in epidermal skin. Skin samples are characterized by a high water content. Such samples investigated with an open-ended PA cell lead to varying conditions in the PA chamber (i.e., change of light absorption or relative humidity) and cause unstable signals. To circumvent variations in relative humidity and possible water condensation, the PA chamber was constantly ventilated by a 10 sccm N2 flow. By bringing the epidermal skin samples in contact with aqueous glucose solutions with different concentrations (i.e., 0.1–10 g/dl), the glucose concentration in the skin sample was varied through passive diffusion. The achieved detection limit for glucose in epidermal skin is 100 mg/dl (SNR=1). Although this lies within the human physiological range (30–500 mg/dl) further improvements are necessary to non-invasively monitor glucose levels of diabetes patients. Furthermore spectra of epidermal tissue with and without glucose content have been recorded with the tunable quantum-cascade laser, indicating that epidermal constituents do not impair glucose detection.
- 1 March 2012
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 3 (4) , 667-680
Open AccessGlucose sensing in human epidermis using mid-infrared photoacoustic detection
No reliable non-invasive glucose monitoring devices are currently available. We implemented a mid-infrared (MIR) photoacoustic (PA) setup to track glucose in vitro in deep epidermal layers, which represents a significant step towards non-invasive in vivo glucose measurements using MIR light. An external-cavity quantum-cascade laser (1010–1095 cm−1) and a PA cell of only 78 mm3 volume were employed to monitor glucose in epidermal skin. Skin samples are characterized by a high water content. Such samples investigated with an open-ended PA cell lead to varying conditions in the PA chamber (i.e., change of light absorption or relative humidity) and cause unstable signals. To circumvent variations in relative humidity and possible water condensation, the PA chamber was constantly ventilated by a 10 sccm N2 flow. By bringing the epidermal skin samples in contact with aqueous glucose solutions with different concentrations (i.e., 0.1–10 g/dl), the glucose concentration in the skin sample was varied through passive diffusion. The achieved detection limit for glucose in epidermal skin is 100 mg/dl (SNR=1). Although this lies within the human physiological range (30–500 mg/dl) further improvements are necessary to non-invasively monitor glucose levels of diabetes patients. Furthermore spectra of epidermal tissue with and without glucose content have been recorded with the tunable quantum-cascade laser, indicating that epidermal constituents do not impair glucose detection.
- 26 March 2010
- Published by Springer Nature in Applied Physics B
- Vol. 100 (1) , 189-194
Near-infrared resonant photoacoustic gas measurement using simultaneous dual-frequency excitation
- 26 March 2010
- Published by Springer Nature in Applied Physics B
- Vol. 100 (1) , 189-194
Near-infrared resonant photoacoustic gas measurement using simultaneous dual-frequency excitation
- 15 May 2009
- Published by Springer Nature in Applied Physics B
- Vol. 96 (2-3) , 561-566
Modulated resonant versus pulsed resonant photoacoustics in trace gas detection
- 15 May 2009
- Published by Springer Nature in Applied Physics B
- Vol. 96 (2-3) , 561-566
Modulated resonant versus pulsed resonant photoacoustics in trace gas detection
- 16 March 2009
- Published by Optica Publishing Group in Optics Letters
- Vol. 34 (7) , 866-868
Laser-based human breath analysis: D/H isotope ratio increase following heavy water intake
Following the ingestion of only of , a mid-infrared laser spectrometer determines the D/H isotope ratio increase in exhaled water vapor for the first time, to the best of our knowledge. This increase is still detectable several weeks after the heavy water intake. Collected breath samples are directly transferred into a high-temperature multipass cell operated at . No breath sample preparation is required. Aside from the capability to hinder unwanted condensation, measurements at elevated temperatures offer other advantages such as a lower temperature dependence of the delta value or the possibility to vary the intensity of absorption lines. We lay the foundation for many laser-based clinical applications. As an example, we measure a total body water weight of with respect to the total body weight, in agreement with the normal value of the male population.- 16 March 2009
- Published by Optica Publishing Group in Optics Letters
- Vol. 34 (7) , 866-868
Laser-based human breath analysis: D/H isotope ratio increase following heavy water intake
Following the ingestion of only of , a mid-infrared laser spectrometer determines the D/H isotope ratio increase in exhaled water vapor for the first time, to the best of our knowledge. This increase is still detectable several weeks after the heavy water intake. Collected breath samples are directly transferred into a high-temperature multipass cell operated at . No breath sample preparation is required. Aside from the capability to hinder unwanted condensation, measurements at elevated temperatures offer other advantages such as a lower temperature dependence of the delta value or the possibility to vary the intensity of absorption lines. We lay the foundation for many laser-based clinical applications. As an example, we measure a total body water weight of with respect to the total body weight, in agreement with the normal value of the male population.- Open Access
- 19 September 2008
- Published by Springer Nature in Patient Safety in Surgery
- Vol. 2 (1) , 22
Gas emission during laparoscopic colorectal surgery using a bipolar vessel sealing device: A pilot study on four patients
Dissection during laparoscopic surgery produces smoke containing potentially toxic substances. The aim of the present study was to analyze smoke samples produced during laparoscopic colon surgery using a bipolar vessel sealing device (LigaSure™). Four consecutive patients undergoing left-sided colectomy were enrolled in this pilot study. Smoke was produced by the use of LigaSure™. Samples (5,5l) were evacuated from the pneumoperitoneum in a closed system into a reservoir. Analysis was performed with CO2-laser-based photoacoustic spectroscopy and confirmed by a Fourier-transform infrared spectrum. The detected spectra were compared to the available spectra of known toxins. Samples from four laparoscopic sigmoid resections were analyzed. No relevant differences were noted regarding patient and operation characteristics. The gas samples were stable over time proven by congruent control measurements as late as 24 h after sampling. The absorption spectra differed considerably between the patients. One broad absorption line at 100 ppm indicating H2O and several unknown molecules were detected. With a sensitivity of alpha min ca 10-5 cm-1 no known toxic substances like phenol or indole were identified. The use of a vessel sealing device during laparoscopic surgery does not produce known toxic substances in relevant quantity. Further studies are needed to identify unknown molecules and to analyze gas emission under various conditions.
- 19 September 2008
- Published by Springer Nature in Patient Safety in Surgery
- Vol. 2 (1) , 22
Open AccessGas emission during laparoscopic colorectal surgery using a bipolar vessel sealing device: A pilot study on four patients
Dissection during laparoscopic surgery produces smoke containing potentially toxic substances. The aim of the present study was to analyze smoke samples produced during laparoscopic colon surgery using a bipolar vessel sealing device (LigaSure™). Four consecutive patients undergoing left-sided colectomy were enrolled in this pilot study. Smoke was produced by the use of LigaSure™. Samples (5,5l) were evacuated from the pneumoperitoneum in a closed system into a reservoir. Analysis was performed with CO2-laser-based photoacoustic spectroscopy and confirmed by a Fourier-transform infrared spectrum. The detected spectra were compared to the available spectra of known toxins. Samples from four laparoscopic sigmoid resections were analyzed. No relevant differences were noted regarding patient and operation characteristics. The gas samples were stable over time proven by congruent control measurements as late as 24 h after sampling. The absorption spectra differed considerably between the patients. One broad absorption line at 100 ppm indicating H2O and several unknown molecules were detected. With a sensitivity of alpha min ca 10-5 cm-1 no known toxic substances like phenol or indole were identified. The use of a vessel sealing device during laparoscopic surgery does not produce known toxic substances in relevant quantity. Further studies are needed to identify unknown molecules and to analyze gas emission under various conditions.
- 11 April 2008
- Published by Optica Publishing Group in Applied Optics
- Vol. 47 (12) , 1956-1962
Mid-infrared spectroscopic investigation of methylamines by a continuous-wave difference-frequency-generation-based system.
A laser spectroscopic system based on a cw difference-frequency generation source with a ratiometric multipass absorption detection scheme was employed for high-resolution spectroscopic investigation of gas-phase monomethylamine (MMA), dimethylamine (DMA), and trimethylamine (TMA). Possible application of the system as a noninvasive human breath analyzer for renal and liver diseases is targeted. The system operates in the fundamental stretch absorption region around . A detection sensitivity of (for signal-to-noise ratio ) is achieved, corresponding to detection limits of (parts in ) for MMA, for DMA, and for TMA in mixtures containing and with concentrations of up to those present in human breath (2% and 5%, respectively). Future developments are discussed to further improve these detection limits that are currently still about 2 orders of magnitude higher than required for direct methylamine monitoring in human breath.- 11 April 2008
- Published by Optica Publishing Group in Applied Optics
- Vol. 47 (12) , 1956-1962
Mid-infrared spectroscopic investigation of methylamines by a continuous-wave difference-frequency-generation-based system.
A laser spectroscopic system based on a cw difference-frequency generation source with a ratiometric multipass absorption detection scheme was employed for high-resolution spectroscopic investigation of gas-phase monomethylamine (MMA), dimethylamine (DMA), and trimethylamine (TMA). Possible application of the system as a noninvasive human breath analyzer for renal and liver diseases is targeted. The system operates in the fundamental stretch absorption region around . A detection sensitivity of (for signal-to-noise ratio ) is achieved, corresponding to detection limits of (parts in ) for MMA, for DMA, and for TMA in mixtures containing and with concentrations of up to those present in human breath (2% and 5%, respectively). Future developments are discussed to further improve these detection limits that are currently still about 2 orders of magnitude higher than required for direct methylamine monitoring in human breath.- 1 January 2008
- Published by Springer Nature
- p. 495-510
Trace Gas Analysis with Isotopic Selectivity Using DFG-Sources
- 1 January 2008
- Published by Springer Nature
- p. 495-510
Trace Gas Analysis with Isotopic Selectivity Using DFG-Sources