Stephanie J. Chiu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Stephanie J. Chiu has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
Joseph A. Izatt
Department of Biomedical Engineering, Duke University, Durham, NC 27708, USA ; Department of Ophthalmology, Duke University School of Medicine, Durham, NC 27710, USA
6 shared publications- Sina Farsiu
Duke University
5 shared publications Cynthia A. Toth
Department of Ophthalmology, Duke University Medical Center, Durham, NC 27710, USA
3 shared publicationsAdam M. Dubis
Department of Ophthalmology, Duke University Medical Center, Durham, North Carolina 27710, USA
1 shared publication- Alex Choi
MIND Study Group, Department of Ophthalmology, Duke University School of Medicine, Durham, NC 27705, USA
1 shared publication Alfred R. Fuller
Univ. of California at Davis (United States)
1 shared publication
Latest Publications
- Open Access
- 20 October 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (20) , 3412
Macular Retinal Layer Thickness in Mild-to-Moderate Parkinson’s Disease
Background/Objectives: Characterization of individual retinal layer thicknesses in mild-to-moderate Parkinson’s disease (PD) remains limited. This study compares retinal layer thicknesses between patients with mild-to-moderate PD and controls. Methods: In this cross-sectional study, patients with PD of Hoehn and Yahr (HY) stage 1 to stage 3 and age- and sex-matched cognitively normal controls without PD underwent spectral-domain optical coherence tomography (OCT) imaging. Seven retinal layers were segmented: nerve fiber layer, ganglion cell–inner plexiform layer (GC-IPL), inner nuclear layer (INL), outer plexiform layer, outer nuclear layer (ONL), photoreceptor layer (PRL), and retinal pigment epithelium (RPE). Mean thickness for each layer and the total retina were measured within the 3 mm and 6 mm Early Treatment Diabetic Retinopathy Study rings. Results: Sixty-seven eyes from 41 patients with PD and 72 eyes from 41 controls were included. In the 6 mm ring, PD eyes had a nominally thicker GC-IPL (p = 0.01), INL (p = 0.01), RPE (p = 0.03), and total retina (p = 0.03) compared to control eyes. In the 6 mm ring, PRL was nominally thinner in HY stage 3 compared to HY stages 2–2.5 (p = 0.02). In the 6 mm ring, the ONL was nominally thinner in the eyes of PD patients in HY stage 3 compared to the eyes of PD patients in HY stages 1–1.5 (p = 0.02) and 2–2.5 (p = 0.04). However, none of these differences remained significant after False Discovery Rate adjustment (all adjusted p > 0.05). Conclusions: In this exploratory cross-sectional study, no significant differences in macular retinal layer thicknesses were found between patients with mild-to-moderate PD and controls without PD after adjusting for multiple comparisons. The nominal thickness differences observed here require larger, longitudinal cohorts to determine if true structural differences exist in mild-to-moderate PD.
- 20 October 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (20) , 3412
Open AccessMacular Retinal Layer Thickness in Mild-to-Moderate Parkinson’s Disease
Background/Objectives: Characterization of individual retinal layer thicknesses in mild-to-moderate Parkinson’s disease (PD) remains limited. This study compares retinal layer thicknesses between patients with mild-to-moderate PD and controls. Methods: In this cross-sectional study, patients with PD of Hoehn and Yahr (HY) stage 1 to stage 3 and age- and sex-matched cognitively normal controls without PD underwent spectral-domain optical coherence tomography (OCT) imaging. Seven retinal layers were segmented: nerve fiber layer, ganglion cell–inner plexiform layer (GC-IPL), inner nuclear layer (INL), outer plexiform layer, outer nuclear layer (ONL), photoreceptor layer (PRL), and retinal pigment epithelium (RPE). Mean thickness for each layer and the total retina were measured within the 3 mm and 6 mm Early Treatment Diabetic Retinopathy Study rings. Results: Sixty-seven eyes from 41 patients with PD and 72 eyes from 41 controls were included. In the 6 mm ring, PD eyes had a nominally thicker GC-IPL (p = 0.01), INL (p = 0.01), RPE (p = 0.03), and total retina (p = 0.03) compared to control eyes. In the 6 mm ring, PRL was nominally thinner in HY stage 3 compared to HY stages 2–2.5 (p = 0.02). In the 6 mm ring, the ONL was nominally thinner in the eyes of PD patients in HY stage 3 compared to the eyes of PD patients in HY stages 1–1.5 (p = 0.02) and 2–2.5 (p = 0.04). However, none of these differences remained significant after False Discovery Rate adjustment (all adjusted p > 0.05). Conclusions: In this exploratory cross-sectional study, no significant differences in macular retinal layer thicknesses were found between patients with mild-to-moderate PD and controls without PD after adjusting for multiple comparisons. The nominal thickness differences observed here require larger, longitudinal cohorts to determine if true structural differences exist in mild-to-moderate PD.
- Top Cited PapersOpen Access
- 9 March 2015
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 6 (4) , 1172-1194
Kernel regression based segmentation of optical coherence tomography images with diabetic macular edema
We present a fully automatic algorithm to identify fluid-filled regions and seven retinal layers on spectral domain optical coherence tomography images of eyes with diabetic macular edema (DME). To achieve this, we developed a kernel regression (KR)-based classification method to estimate fluid and retinal layer positions. We then used these classification estimates as a guide to more accurately segment the retinal layer boundaries using our previously described graph theory and dynamic programming (GTDP) framework. We validated our algorithm on 110 B-scans from ten patients with severe DME pathology, showing an overall mean Dice coefficient of 0.78 when comparing our KR + GTDP algorithm to an expert grader. This is comparable to the inter-observer Dice coefficient of 0.79. The entire data set is available online, including our automatic and manual segmentation results. To the best of our knowledge, this is the first validated, fully-automated, seven-layer and fluid segmentation method which has been applied to real-world images containing severe DME.
- 9 March 2015
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 6 (4) , 1172-1194
Top Cited PapersOpen AccessKernel regression based segmentation of optical coherence tomography images with diabetic macular edema
We present a fully automatic algorithm to identify fluid-filled regions and seven retinal layers on spectral domain optical coherence tomography images of eyes with diabetic macular edema (DME). To achieve this, we developed a kernel regression (KR)-based classification method to estimate fluid and retinal layer positions. We then used these classification estimates as a guide to more accurately segment the retinal layer boundaries using our previously described graph theory and dynamic programming (GTDP) framework. We validated our algorithm on 110 B-scans from ten patients with severe DME pathology, showing an overall mean Dice coefficient of 0.78 when comparing our KR + GTDP algorithm to an expert grader. This is comparable to the inter-observer Dice coefficient of 0.79. The entire data set is available online, including our automatic and manual segmentation results. To the best of our knowledge, this is the first validated, fully-automated, seven-layer and fluid segmentation method which has been applied to real-world images containing severe DME.
- Open Access
- 22 May 2013
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 4 (6) , 924-937
Automatic cone photoreceptor segmentation using graph theory and dynamic programming
Geometrical analysis of the photoreceptor mosaic can reveal subclinical ocular pathologies. In this paper, we describe a fully automatic algorithm to identify and segment photoreceptors in adaptive optics ophthalmoscope images of the photoreceptor mosaic. This method is an extension of our previously described closed contour segmentation framework based on graph theory and dynamic programming (GTDP). We validated the performance of the proposed algorithm by comparing it to the state-of-the-art technique on a large data set consisting of over 200,000 cones and posted the results online. We found that the GTDP method achieved a higher detection rate, decreasing the cone miss rate by over a factor of five.
- 22 May 2013
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 4 (6) , 924-937
Open AccessAutomatic cone photoreceptor segmentation using graph theory and dynamic programming
Geometrical analysis of the photoreceptor mosaic can reveal subclinical ocular pathologies. In this paper, we describe a fully automatic algorithm to identify and segment photoreceptors in adaptive optics ophthalmoscope images of the photoreceptor mosaic. This method is an extension of our previously described closed contour segmentation framework based on graph theory and dynamic programming (GTDP). We validated the performance of the proposed algorithm by comparing it to the state-of-the-art technique on a large data set consisting of over 200,000 cones and posted the results online. We found that the GTDP method achieved a higher detection rate, decreasing the cone miss rate by over a factor of five.
- Open Access
- 26 April 2012
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 3 (5) , 1127-1140
Automatic segmentation of closed-contour features in ophthalmic images using graph theory and dynamic programming
This paper presents a generalized framework for segmenting closed-contour anatomical and pathological features using graph theory and dynamic programming (GTDP). More specifically, the GTDP method previously developed for quantifying retinal and corneal layer thicknesses is extended to segment objects such as cells and cysts. The presented technique relies on a transform that maps closed-contour features in the Cartesian domain into lines in the quasi-polar domain. The features of interest are then segmented as layers via GTDP. Application of this method to segment closed-contour features in several ophthalmic image types is shown. Quantitative validation experiments for retinal pigmented epithelium cell segmentation in confocal fluorescence microscopy images attests to the accuracy of the presented technique.
- 26 April 2012
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 3 (5) , 1127-1140
Open AccessAutomatic segmentation of closed-contour features in ophthalmic images using graph theory and dynamic programming
This paper presents a generalized framework for segmenting closed-contour anatomical and pathological features using graph theory and dynamic programming (GTDP). More specifically, the GTDP method previously developed for quantifying retinal and corneal layer thicknesses is extended to segment objects such as cells and cysts. The presented technique relies on a transform that maps closed-contour features in the Cartesian domain into lines in the quasi-polar domain. The features of interest are then segmented as layers via GTDP. Application of this method to segment closed-contour features in several ophthalmic image types is shown. Quantitative validation experiments for retinal pigmented epithelium cell segmentation in confocal fluorescence microscopy images attests to the accuracy of the presented technique.
- Open Access
- 1 January 2012
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 53 (1) , 53-61
Validated Automatic Segmentation of AMD Pathology Including Drusen and Geographic Atrophy in SD-OCT Images
Purpose.: To automatically segment retinal spectral domain optical coherence tomography (SD-OCT) images of eyes with age-related macular degeneration (AMD) and various levels of image quality to advance the study of retinal pigment epithelium (RPE)+drusen complex (RPEDC) volume changes indicative of AMD progression. Methods.: A general segmentation framework based on graph theory and dynamic programming was used to segment three retinal boundaries in SD-OCT images of eyes with drusen and geographic atrophy (GA). A validation study for eyes with nonneovascular AMD was conducted, forming subgroups based on scan quality and presence of GA. To test for accuracy, the layer thickness results from two certified graders were compared against automatic segmentation results for 220 B-scans across 20 patients. For reproducibility, automatic layer volumes were compared that were generated from 0° versus 90° scans in five volumes with drusen. Results.: The mean differences in the measured thicknesses of the total retina and RPEDC layers were 4.2 ± 2.8 and 3.2 ± 2.6 μm for automatic versus manual segmentation. When the 0° and 90° datasets were compared, the mean differences in the calculated total retina and RPEDC volumes were 0.28% ± 0.28% and 1.60% ± 1.57%, respectively. The average segmentation time per image was 1.7 seconds automatically versus 3.5 minutes manually. Conclusions.: The automatic algorithm accurately and reproducibly segmented three retinal boundaries in images containing drusen and GA. This automatic approach can reduce time and labor costs and yield objective measurements that potentially reveal quantitative RPE changes in longitudinal clinical AMD studies. (ClinicalTrials.gov number, NCT00734487.)
- 1 January 2012
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 53 (1) , 53-61
Open AccessValidated Automatic Segmentation of AMD Pathology Including Drusen and Geographic Atrophy in SD-OCT Images
Purpose.: To automatically segment retinal spectral domain optical coherence tomography (SD-OCT) images of eyes with age-related macular degeneration (AMD) and various levels of image quality to advance the study of retinal pigment epithelium (RPE)+drusen complex (RPEDC) volume changes indicative of AMD progression. Methods.: A general segmentation framework based on graph theory and dynamic programming was used to segment three retinal boundaries in SD-OCT images of eyes with drusen and geographic atrophy (GA). A validation study for eyes with nonneovascular AMD was conducted, forming subgroups based on scan quality and presence of GA. To test for accuracy, the layer thickness results from two certified graders were compared against automatic segmentation results for 220 B-scans across 20 patients. For reproducibility, automatic layer volumes were compared that were generated from 0° versus 90° scans in five volumes with drusen. Results.: The mean differences in the measured thicknesses of the total retina and RPEDC layers were 4.2 ± 2.8 and 3.2 ± 2.6 μm for automatic versus manual segmentation. When the 0° and 90° datasets were compared, the mean differences in the calculated total retina and RPEDC volumes were 0.28% ± 0.28% and 1.60% ± 1.57%, respectively. The average segmentation time per image was 1.7 seconds automatically versus 3.5 minutes manually. Conclusions.: The automatic algorithm accurately and reproducibly segmented three retinal boundaries in images containing drusen and GA. This automatic approach can reduce time and labor costs and yield objective measurements that potentially reveal quantitative RPE changes in longitudinal clinical AMD studies. (ClinicalTrials.gov number, NCT00734487.)
- Top Cited PapersOpen Access
- 27 August 2010
- Published by Optica Publishing Group in Optics Express
- Vol. 18 (18) , 19413-19428
Automatic segmentation of seven retinal layers in SDOCT images congruent with expert manual segmentation
Segmentation of anatomical and pathological structures in ophthalmic images is crucial for the diagnosis and study of ocular diseases. However, manual segmentation is often a time-consuming and subjective process. This paper presents an automatic approach for segmenting retinal layers in Spectral Domain Optical Coherence Tomography images using graph theory and dynamic programming. Results show that this method accurately segments eight retinal layer boundaries in normal adult eyes more closely to an expert grader as compared to a second expert grader.
- 27 August 2010
- Published by Optica Publishing Group in Optics Express
- Vol. 18 (18) , 19413-19428
Top Cited PapersOpen AccessAutomatic segmentation of seven retinal layers in SDOCT images congruent with expert manual segmentation
Segmentation of anatomical and pathological structures in ophthalmic images is crucial for the diagnosis and study of ocular diseases. However, manual segmentation is often a time-consuming and subjective process. This paper presents an automatic approach for segmenting retinal layers in Spectral Domain Optical Coherence Tomography images using graph theory and dynamic programming. Results show that this method accurately segments eight retinal layer boundaries in normal adult eyes more closely to an expert grader as compared to a second expert grader.
- 8 February 2007
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6426, 64260W
Development of quantitative diagnostic observables for age-related macular degeneration using Spectral Domain OCT
We report on the development of quantitative, reproducible diagnostic observables for age-related macular degeneration (AMD) based on high speed spectral domain optical coherence tomography (SDOCT). 3D SDOCT volumetric data sets (512 x 1000 x 100 voxels) were collected (5.7 seconds acquisition time) in over 50 patients with age-related macular degeneration and geographic atrophy using a state-of-the-art SDOCT scanner. Commercial and custom software utilities were used for manual and semi-automated segmentation of photoreceptor layer thickness, total drusen volume, and geographic atrophy cross-sectional area. In a preliminary test of reproducibility in segmentation of total drusen volume and geographic atrophy surface area, inter-observer error was less than 5%. Extracted volume and surface area of AMD-related drusen and geographic atrophy, respectively, may serve as useful observables for tracking disease state that were not accessible without the rapid 3D volumetric imaging capability unique to retinal SDOCT.
- 8 February 2007
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6426, 64260W
Development of quantitative diagnostic observables for age-related macular degeneration using Spectral Domain OCT
We report on the development of quantitative, reproducible diagnostic observables for age-related macular degeneration (AMD) based on high speed spectral domain optical coherence tomography (SDOCT). 3D SDOCT volumetric data sets (512 x 1000 x 100 voxels) were collected (5.7 seconds acquisition time) in over 50 patients with age-related macular degeneration and geographic atrophy using a state-of-the-art SDOCT scanner. Commercial and custom software utilities were used for manual and semi-automated segmentation of photoreceptor layer thickness, total drusen volume, and geographic atrophy cross-sectional area. In a preliminary test of reproducibility in segmentation of total drusen volume and geographic atrophy surface area, inter-observer error was less than 5%. Extracted volume and surface area of AMD-related drusen and geographic atrophy, respectively, may serve as useful observables for tracking disease state that were not accessible without the rapid 3D volumetric imaging capability unique to retinal SDOCT.