Shaohua Kevin Zhou
Shaohua Kevin Zhou has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Dorin Comaniciu
Siemens Healthineers
2 shared publications - Jingdan Zhang
Siemens Corporation
2 shared publications - John C. Rasmussen
Brown Foundation Institute of Molecular Medicine, McGovern Medical School, The University of Texas Health Science Center at Houston, Houston, TX, United States
2 shared publications Xiaoyan Xiang
Whole Body and Oncology Image Analytics Program, Siemens Corporate Research, 755 College Road East, Princeton, New Jersey, 08540, USA
2 shared publications- Andreas Meyer
Siemens AG Healthcare
1 shared publication Blake A. Niccum
Center for Molecular Imaging, The Brown Foundation Institute of Molecular Medicine, The University of Texas Health Science Center at Houston, 1825 Pressler Street, Houston, Texas, 77030, USA
1 shared publication
Latest Publications
- 21 November 2015
- Published by Springer Nature
- p. 415-434
Turbine Fatigue Reliability and Life Assessment Using Ultrasonic Inspection: Data Acquisition, Interpretation, and Probabilistic Modeling
- 21 November 2015
- Published by Springer Nature
- p. 415-434
Turbine Fatigue Reliability and Life Assessment Using Ultrasonic Inspection: Data Acquisition, Interpretation, and Probabilistic Modeling
- 21 September 2012
- Published by Springer Nature in International Journal of Computer Vision
- Vol. 101 (2) , 305-328
Recognizing Interactive Group Activities Using Temporal Interaction Matrices and Their Riemannian Statistics
- 21 September 2012
- Published by Springer Nature in International Journal of Computer Vision
- Vol. 101 (2) , 305-328
Recognizing Interactive Group Activities Using Temporal Interaction Matrices and Their Riemannian Statistics
- Open Access
- 22 June 2012
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 3 (7) , 1713-1723
Automated analysis of investigational near-infrared fluorescence lymphatic imaging in humans
ALFIA (Automated Lymphatic Function Imaging Analysis), an algorithm providing quantitative analysis of investigational near-infrared fluorescence lymphatic images, is described. Images from nine human subjects were analyzed for apparent lymphatic propagation velocities and propulsion periods using manual analysis and ALFIA. While lymphatic propulsion was more easily detected using ALFIA than with manual analysis, statistical analyses indicate no significant difference in the apparent lymphatic velocities although ALFIA tended to calculate longer propulsion periods. With the base ALFIA algorithms validated, further automation can now proceed to provide a clinically relevant analytic tool for quantitatively assessing lymphatic function in humans.
- 22 June 2012
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 3 (7) , 1713-1723
Open AccessAutomated analysis of investigational near-infrared fluorescence lymphatic imaging in humans
ALFIA (Automated Lymphatic Function Imaging Analysis), an algorithm providing quantitative analysis of investigational near-infrared fluorescence lymphatic images, is described. Images from nine human subjects were analyzed for apparent lymphatic propagation velocities and propulsion periods using manual analysis and ALFIA. While lymphatic propulsion was more easily detected using ALFIA than with manual analysis, statistical analyses indicate no significant difference in the apparent lymphatic velocities although ALFIA tended to calculate longer propulsion periods. With the base ALFIA algorithms validated, further automation can now proceed to provide a clinically relevant analytic tool for quantitatively assessing lymphatic function in humans.
- 19 January 2012
- Published by Springer Nature
- p. 273-306
Discriminative Learning for Anatomical Structure Detection and Segmentation
- 19 January 2012
- Published by Springer Nature
- p. 273-306
Discriminative Learning for Anatomical Structure Detection and Segmentation
- 10 February 2011
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7902
Validation of ALFIA: a platform for quantifying near-infrared fluorescent images of lymphatic propulsion in humans
Recently, we demonstrated near-infrared (NIR) fluorescence imaging for quantifying real-time lymphatic propulsion in humans following intradermal injections of microdose amounts of indocyanine green. However computational methods for image analysis are underdeveloped, hindering the translation and clinical adaptation of NIR fluorescent lymphatic imaging. In our initial work we used ImageJ and custom MatLab programs to manually identify lymphatic vessels and individual propulsion events using the temporal transit of the fluorescent dye. In addition, we extracted the apparent velocities of contractile propagation and time periods between propulsion events. Extensive time and effort were required to analyze the 6-8 gigabytes of NIR fluorescent images obtained for each subject. To alleviate this bottleneck, we commenced development of ALFIA, an integrated software platform which will permit automated, near real-time analysis of lymphatic function using NIR fluorescent imaging. However, prior to automation, the base algorithms calculating the apparent velocity and period must be validated to verify that they produce results consistent with the proof-of-concept programs. To do this, both methods were used to analyze NIR fluorescent images of two subjects and the number of propulsive events identified, the average apparent velocities, and the average periods for each subject were compared. Paired Student's t-tests indicate that the differences between their average results are not significant. With the base algorithms validated, further development and automation of ALFIA can be realized, significantly reducing the amount of user interaction required, and potentially enabling the near real-time, clinical evaluation of NIR fluorescent lymphatic imaging.
- 10 February 2011
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7902
Validation of ALFIA: a platform for quantifying near-infrared fluorescent images of lymphatic propulsion in humans
Recently, we demonstrated near-infrared (NIR) fluorescence imaging for quantifying real-time lymphatic propulsion in humans following intradermal injections of microdose amounts of indocyanine green. However computational methods for image analysis are underdeveloped, hindering the translation and clinical adaptation of NIR fluorescent lymphatic imaging. In our initial work we used ImageJ and custom MatLab programs to manually identify lymphatic vessels and individual propulsion events using the temporal transit of the fluorescent dye. In addition, we extracted the apparent velocities of contractile propagation and time periods between propulsion events. Extensive time and effort were required to analyze the 6-8 gigabytes of NIR fluorescent images obtained for each subject. To alleviate this bottleneck, we commenced development of ALFIA, an integrated software platform which will permit automated, near real-time analysis of lymphatic function using NIR fluorescent imaging. However, prior to automation, the base algorithms calculating the apparent velocity and period must be validated to verify that they produce results consistent with the proof-of-concept programs. To do this, both methods were used to analyze NIR fluorescent images of two subjects and the number of propulsive events identified, the average apparent velocities, and the average periods for each subject were compared. Paired Student's t-tests indicate that the differences between their average results are not significant. With the base algorithms validated, further development and automation of ALFIA can be realized, significantly reducing the amount of user interaction required, and potentially enabling the near real-time, clinical evaluation of NIR fluorescent lymphatic imaging.
- 1 January 2011
- Published by Springer Nature
- p. 159-177
A Framework of Wire Tracking in Image Guided Interventions
- 1 January 2011
- Published by Springer Nature
- p. 159-177
A Framework of Wire Tracking in Image Guided Interventions
- 1 August 2010
- Published by Elsevier in Medical Image Analysis
- Vol. 14 (4) , 563-581
Shape regression machine and efficient segmentation of left ventricle endocardium from 2D B-mode echocardiogram
- 1 August 2010
- Published by Elsevier in Medical Image Analysis
- Vol. 14 (4) , 563-581
Shape regression machine and efficient segmentation of left ventricle endocardium from 2D B-mode echocardiogram
- 1 January 2006
- Published by Springer Nature in Lecture Notes in Computer Science
- Vol. 9, 736-743
Pairwise Active Appearance Model and Its Application to Echocardiography Tracking
We propose a pairwise active appearance model (PAAM) to characterize statistical regularities in shape, appearance, and motion presented by a target that undergoes a series of motion phases, such as the left ventricle in echocardiography. The PAAM depicts the transition in motion phase through a Markov chain and the transition in both shape and appearance through a conditional Gaussian distribution. We learn from a database the joint Gaussian distribution of the shapes and appearances belonging to two consecutive motion phases (i.e., a pair of motion phases), from which we analytically compute the conditional Gaussian distribution. We utilize the PAAM in tracking the left ventricle contour in echocardiography and obtain improved tracking results in terms of localization accuracy when compared with expert-specified contours.
- 1 January 2006
- Published by Springer Nature in Lecture Notes in Computer Science
- Vol. 9, 736-743
Pairwise Active Appearance Model and Its Application to Echocardiography Tracking
We propose a pairwise active appearance model (PAAM) to characterize statistical regularities in shape, appearance, and motion presented by a target that undergoes a series of motion phases, such as the left ventricle in echocardiography. The PAAM depicts the transition in motion phase through a Markov chain and the transition in both shape and appearance through a conditional Gaussian distribution. We learn from a database the joint Gaussian distribution of the shapes and appearances belonging to two consecutive motion phases (i.e., a pair of motion phases), from which we analytically compute the conditional Gaussian distribution. We utilize the PAAM in tracking the left ventricle contour in echocardiography and obtain improved tracking results in terms of localization accuracy when compared with expert-specified contours.