James M. Zavislan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
James M. Zavislan has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Linda M. Schiffhauer
University of Rochester Medical Center, Department of Pathology and Laboratory Medicine, 601 Elmwood Ave, Box 626, Rochester, NY 14642, USA
2 shared publicationsAizhong Zhang
University of Rochester Flaum Eye Institute, Ocular Surface Laboratory, Rochester, NY, USA; Institute of Optics, University of Rochester, Rochester, NY, USA
1 shared publicationChristopher E. Glazowski
Institute of Optics, University of Rochester, Rochester, NY 14627, USA
1 shared publicationChristopher Glazowski
Institute of Optics, Univ. of Rochester (United States)
1 shared publicationGeunyoung Yoon
University of Rochester Flaum Eye Institute, Ocular Surface Laboratory, Rochester, NY, USA; Institute of Optics, University of Rochester, Rochester, NY, USA
1 shared publicationGheorghe Salahura
University of Rochester Flaum Eye Institute, Ocular Surface Laboratory, Rochester, NY, USA; Institute of Optics, University of Rochester, Rochester, NY, USA
1 shared publication
Latest Publications
- 1 March 2015
- Published by Elsevier in Experimental Eye Research
- Vol. 132, 231-239
Thermal analysis of dry eye subjects and the thermal impulse perturbation model of ocular surface
- 1 March 2015
- Published by Elsevier in Experimental Eye Research
- Vol. 132, 231-239
Thermal analysis of dry eye subjects and the thermal impulse perturbation model of ocular surface
- Open Access
- 1 August 2014
- Published by Elsevier in The Breast
- Vol. 23 (4) , 413-422
Optical segmentation of unprocessed breast tissue for margin assessment
- 1 August 2014
- Published by Elsevier in The Breast
- Vol. 23 (4) , 413-422
Open AccessOptical segmentation of unprocessed breast tissue for margin assessment
- 7 June 2013
- Published by Optica Publishing Group in Applied Optics
- Vol. 52 (17) , 4024-4034
Design and validation of two optical beacons for guidewire localization in breast-conserving surgery.
Stereotactically placed guidewires are used for indicating the location of a nonpalpable carcinoma in breast-conserving surgery. Pathologists use the end of the embedded guidewire to guide sectioning during intraoperative margin assessment, but they do not currently have a tool to indicate the location of the guidewire end for informed sectioning. We present analysis and experimental testing of two optical methods for localizing the end of an embedded fiber-optic guidewire: the first uses irradiance emitted from the fiber to indicate the location of the guidewire end, while the second system uses the fiber optic to create a photoacoustic pulse for localization. Both systems locate the end of the guidewire within , which ensures that the lesion of interest is bisected during sectioning. The accuracy of the irradiance-based beacon is influenced by standard margin paints, so the photoacoustic beacon proved more useful under current tissue-handling protocols.- 7 June 2013
- Published by Optica Publishing Group in Applied Optics
- Vol. 52 (17) , 4024-4034
Design and validation of two optical beacons for guidewire localization in breast-conserving surgery.
Stereotactically placed guidewires are used for indicating the location of a nonpalpable carcinoma in breast-conserving surgery. Pathologists use the end of the embedded guidewire to guide sectioning during intraoperative margin assessment, but they do not currently have a tool to indicate the location of the guidewire end for informed sectioning. We present analysis and experimental testing of two optical methods for localizing the end of an embedded fiber-optic guidewire: the first uses irradiance emitted from the fiber to indicate the location of the guidewire end, while the second system uses the fiber optic to create a photoacoustic pulse for localization. Both systems locate the end of the guidewire within , which ensures that the lesion of interest is bisected during sectioning. The accuracy of the irradiance-based beacon is influenced by standard margin paints, so the photoacoustic beacon proved more useful under current tissue-handling protocols.- Open Access
- 4 March 2013
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 4 (4) , 500-513
A coherent model for turbid imaging with confocal microscopy
We present an engineering model of coherent imaging within a turbid volume, such as human tissues, with a confocal microscope. The model is built to analyze the statistical effect of aberrations and multiply scattered light on the resulting image. Numerical modeling of theory is compared with experimental results. We describe the construction of a stable phantom that represents the statistical effect of object turbidity on the image recorded. The model and phantom can serve as basis for system optimization in turbid imaging.
- 4 March 2013
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 4 (4) , 500-513
Open AccessA coherent model for turbid imaging with confocal microscopy
We present an engineering model of coherent imaging within a turbid volume, such as human tissues, with a confocal microscope. The model is built to analyze the statistical effect of aberrations and multiply scattered light on the resulting image. Numerical modeling of theory is compared with experimental results. We describe the construction of a stable phantom that represents the statistical effect of object turbidity on the image recorded. The model and phantom can serve as basis for system optimization in turbid imaging.
- 11 February 2010
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7570
Coherent pupil engineered scanning reflectance confocal microscope (SRCM) for turbid imaging
It is well known that use of laser illumination in microscopic imaging can lead to speckle in the resultant images. The influence of speckle artifact is more pronounced particularly when investigating deep regions of biological samples. Furthermore, the regions of turbid media above the focal plane of interest impart statistical modifications to the resulting background and focal signal, which then coherently interfere at the pinhole plane. Through a coherent model of imaging in a scanning reflectance confocal microscope (SRCM) and subsequent experimental evidence, we have shown that engineering the electric field distribution in the system's pupils can be framed in the sense of two-beam-interference of the focal signal and background light. With this model we have theoretically studied the effect of two spatially nonsymmetric electric field distributions and their effect on resultant images for turbid media in a moderately high numerical-aperture (NA = 0.9) SRCM system; these distributions are TEM10 and a novel Nomarski DIC. Signal and background/speckle statistics were parameterized against these pupil distributions and compared to standard TEM00 pupil illumination.
- 11 February 2010
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7570
Coherent pupil engineered scanning reflectance confocal microscope (SRCM) for turbid imaging
It is well known that use of laser illumination in microscopic imaging can lead to speckle in the resultant images. The influence of speckle artifact is more pronounced particularly when investigating deep regions of biological samples. Furthermore, the regions of turbid media above the focal plane of interest impart statistical modifications to the resulting background and focal signal, which then coherently interfere at the pinhole plane. Through a coherent model of imaging in a scanning reflectance confocal microscope (SRCM) and subsequent experimental evidence, we have shown that engineering the electric field distribution in the system's pupils can be framed in the sense of two-beam-interference of the focal signal and background light. With this model we have theoretically studied the effect of two spatially nonsymmetric electric field distributions and their effect on resultant images for turbid media in a moderately high numerical-aperture (NA = 0.9) SRCM system; these distributions are TEM10 and a novel Nomarski DIC. Signal and background/speckle statistics were parameterized against these pupil distributions and compared to standard TEM00 pupil illumination.