ALAndrew Lang

Andrew Lang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Andrew Lang has a total of 13 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Intensity inhomogeneity correction of SD-OCT data using macular flatspace

    by Andrew Lang, Aaron Carass, Bruno M. Jedynak, Sharon D. Solomon, Peter A. Calabresi, Jerry L. Prince


  • Open Access

    Automatic segmentation of microcystic macular edema in OCT

    by Andrew Lang, Aaron Carass, Emily K. Swingle, Omar Al-Louzi, Pavan Bhargava, Shiv Saidha, Howard S. Ying, Peter A. Calabresi, Jerry L. Prince

    Microcystic macular edema (MME) manifests as small, hyporeflective cystic areas within the retina. For reasons that are still largely unknown, a small proportion of patients with multiple sclerosis (MS) develop MME—predominantly in the inner nuclear layer. These cystoid spaces, denoted pseudocysts, can be imaged using optical coherence tomography (OCT) where they appear as small, discrete, low intensity areas with high contrast to the surrounding tissue. The ability to automatically segment these pseudocysts would enable a more detailed study of MME than has been previously possible. Although larger pseudocysts often appear quite clearly in the OCT images, the multi-frame averaging performed by the Spectralis scanner adds a significant amount of variability to the appearance of smaller pseudocysts. Thus, simple segmentation methods only incorporating intensity information do not perform well. In this work, we propose to use a random forest classifier to classify the MME pixels. An assortment of both intensity and spatial features are used to aid the classification. Using a cross-validation evaluation strategy with manual delineation as ground truth, our method is able to correctly identify 79% of pseudocysts with a precision of 85%. Finally, we constructed a classifier from the output of our algorithm to distinguish clinically identified MME from non-MME subjects yielding an accuracy of 92%.


  • Microcystic macular edema detection in retina OCT images

    by Emily K. Swingle, Andrew Lang, Aaron Carass, Howard S. Ying, Peter A. Calabresi, Jerry L. Prince

    Optical coherence tomography (OCT) is a powerful imaging tool that is particularly useful for exploring retinal abnormalities in ophthalmological diseases. Recently, it has been used to track changes in the eye associated with neurological diseases such as multiple sclerosis (MS) where certain tissue layer thicknesses have been associated with disease progression. A small percentage of MS patients also exhibit what has been called microcystic macular edema (MME), where uid collections that are thought to be pseudocysts appear in the inner nuclear layer. Very little is known about the cause of this condition so it is important to be able to identify precisely where these pseudocysts occur within the retina. This identi cation would be an important rst step towards furthering our understanding. In this work, we present a detection algorithm to nd these pseudocysts and to report on their spatial distribution. Our approach uses a random forest classi er trained on manual segmentation data to classify each voxel as pseudocyst or not. Despite having a small sample size of ve subjects, the algorithm correctly identi es 84.6% of pseudocysts as compared to manual delineation. Finally, using our method, we show that the spatial distribution of pseudocysts within the macula are generally contained within an annulus around the fovea.


  • Top Cited Papers
    Open Access

    Retinal layer segmentation of macular OCT images using boundary classification

    by Andrew Lang, Aaron Carass, Matthew Hauser, Elias S. Sotirchos, Peter A. Calabresi, Howard S. Ying, Jerry L. Prince

    Optical coherence tomography (OCT) has proven to be an essential imaging modality for ophthalmology and is proving to be very important in neurology. OCT enables high resolution imaging of the retina, both at the optic nerve head and the macula. Macular retinal layer thicknesses provide useful diagnostic information and have been shown to correlate well with measures of disease severity in several diseases. Since manual segmentation of these layers is time consuming and prone to bias, automatic segmentation methods are critical for full utilization of this technology. In this work, we build a random forest classifier to segment eight retinal layers in macular cube images acquired by OCT. The random forest classifier learns the boundary pixels between layers, producing an accurate probability map for each boundary, which is then processed to finalize the boundaries. Using this algorithm, we can accurately segment the entire retina contained in the macular cube to an accuracy of at least 4.3 microns for any of the nine boundaries. Experiments were carried out on both healthy and multiple sclerosis subjects, with no difference in the accuracy of our algorithm found between the groups.