Sergei Gasilov
Research Subjects
Sergei Gasilov has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Paola Coan
Faculty of Medicine and Institute of Clinical Radiology, Ludwig-Maximilians University, Munich, Germany
2 shared publications Alberto Bravin
European Synchrotron Radiation Facility (ESRF), Grenoble 38043, France
1 shared publication- Alberto Mittone
European Synchrotron Radiation Facility, Grenoble, France
1 shared publication - Emmanuel Brun
Université Grenoble Alpes, Inserm UA7Strobe Laboratory, 38000 Grenoble, France
1 shared publication Susanne Grandl
Department of Clinical Radiology, Ludwig Maximilians University, Munich 81377, Germany
1 shared publication
Latest Publications
- 2 August 2013
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 4 (9) , 1512-8
On the possibility of quantitative refractive-index tomography of large biomedical samples with hard X-rays
One of the most promising applications of the X-ray phase-contrast imaging is the three dimensional tomographic reconstruction of the index of refraction. However, results reported so far are limited to relatively small samples. We present here the tomographic reconstruction of the index of refraction distribution of a large biomedical sample (> 10 cm diameter). A quantitative study comparing the absorption and phase contrast (analyzer-based) tomography images shows that the distribution of the index of refraction obtained with the phase contrast method provides a more accurate depiction (3-10 times larger signal to noise ratio values) of the sample internal structure. Thanks to the higher sensitivity of this method, the improved precision was obtained using an incoming photon fluence on the sample several times smaller than in the case of absorption imaging.
- 2 August 2013
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 4 (9) , 1512-8
On the possibility of quantitative refractive-index tomography of large biomedical samples with hard X-rays
One of the most promising applications of the X-ray phase-contrast imaging is the three dimensional tomographic reconstruction of the index of refraction. However, results reported so far are limited to relatively small samples. We present here the tomographic reconstruction of the index of refraction distribution of a large biomedical sample (> 10 cm diameter). A quantitative study comparing the absorption and phase contrast (analyzer-based) tomography images shows that the distribution of the index of refraction obtained with the phase contrast method provides a more accurate depiction (3-10 times larger signal to noise ratio values) of the sample internal structure. Thanks to the higher sensitivity of this method, the improved precision was obtained using an incoming photon fluence on the sample several times smaller than in the case of absorption imaging.
- 15 August 2012
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 29 (9) , 1870-1876
X-ray phase contrast imaging of objects with subpixel-size inhomogeneities: a geometrical optics model
Several x-ray phase contrast extraction algorithms use a set of images acquired along the rocking curve of a perfect flat analyzer crystal to study the internal structure of objects. By measuring the angular shift of the rocking curve peak, one can determine the local deflections of the x-ray beam propagated through a sample. Additionally, some objects determine a broadening of the crystal rocking curve, which can be explained in terms of multiple refraction of x rays by many subpixel-size inhomogeneities contained in the sample. This fact may allow us to differentiate between materials and features characterized by different refraction properties. In the present work we derive an expression for the beam broadening in the form of a linear integral of the quantity related to statistical properties of the dielectric susceptibility distribution function of the object.
- 15 August 2012
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 29 (9) , 1870-1876
X-ray phase contrast imaging of objects with subpixel-size inhomogeneities: a geometrical optics model
Several x-ray phase contrast extraction algorithms use a set of images acquired along the rocking curve of a perfect flat analyzer crystal to study the internal structure of objects. By measuring the angular shift of the rocking curve peak, one can determine the local deflections of the x-ray beam propagated through a sample. Additionally, some objects determine a broadening of the crystal rocking curve, which can be explained in terms of multiple refraction of x rays by many subpixel-size inhomogeneities contained in the sample. This fact may allow us to differentiate between materials and features characterized by different refraction properties. In the present work we derive an expression for the beam broadening in the form of a linear integral of the quantity related to statistical properties of the dielectric susceptibility distribution function of the object.