Roger Haene
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Roger Haene has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Ellie Pinsker
St Michael's Hospital, Unity Health Toronto, Toronto, Ontario, Canada
1 shared publication - Erion Qamirani1 shared publication
M. Loeffler
Department of Orthopaedic Surgery Colchester General Hospital, Turner Road, Colchester, Essex CO4 5JL, UK
1 shared publicationRanbir S Sandhu
Department of Orthopaedic and Trauma Surgery, Ipswich Hospital Ipswich, UK
1 shared publicationRichard Baxandall
Department of Orthopaedic and Trauma Surgery, Ipswich Hospital Ipswich, UK
1 shared publication- Robert A. Story1 shared publication
Latest Publications
- 20 June 2012
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 94 (12) , 1105-1110
Intermediate Outcomes of Fresh Talar Osteochondral Allografts for Treatment of Large Osteochondral Lesions of the Talus
Ft transfer. The goal of this study was to prospectively evaluate the intermediate outcomes of fresh osteochondral allografting for osteochondral lesions of the talus with use of validated outcome measures. Methods: Sixteen patients (seventeen ankles) received a fresh osteochondral allograft, and all sixteen were available for follow-up. Data were prospectively collected with use of the Ankle Osteoarthritis Scale (AOS), Short Form-36 (SF-36), and American Academy of Orthopaedic Surgeons (AAOS) Foot and Ankle Module outcome measures. Postoperative American Orthopaedic Foot & Ankle Society (AOFAS) hindfoot scale scores were also collected. All sixteen patients underwent radiographic and computed tomographic (CT) analyses preoperatively, and fifteen patients had these studies postoperatively. Results: The average duration of follow-up was 4.1 years. The latest follow-up CT evaluation identified failure of graft incorporation in two of sixteen ankles. Osteolysis, subchondral cysts, and degenerative changes were found in five, eight, and seven ankles, respectively. Five ankles were considered failures, and two required a reoperation because of ongoing symptoms. The AOS Disability and the AAOS Foot and Ankle Core Scale scores significantly improved, but there was no significant change in the AOS Pain, AAOS Foot and Ankle Shoe Comfort Scale, or SF-36 scores. Overall, ten patients had a good or excellent result; however, persistent symptoms remained in six of these patients. Only four were symptom-free. Conclusion: The use of a fresh osteochondral allograft is a reasonable option for the treatment of large talar osteochondral lesions. The high reoperation rate (two of seventeen) and failure rate (five of seventeen) must be taken into consideration when one is choosing this procedure for the management of these lesions. Level of Evidence: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence....
- 20 June 2012
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 94 (12) , 1105-1110
Intermediate Outcomes of Fresh Talar Osteochondral Allografts for Treatment of Large Osteochondral Lesions of the Talus
Ft transfer. The goal of this study was to prospectively evaluate the intermediate outcomes of fresh osteochondral allografting for osteochondral lesions of the talus with use of validated outcome measures. Methods: Sixteen patients (seventeen ankles) received a fresh osteochondral allograft, and all sixteen were available for follow-up. Data were prospectively collected with use of the Ankle Osteoarthritis Scale (AOS), Short Form-36 (SF-36), and American Academy of Orthopaedic Surgeons (AAOS) Foot and Ankle Module outcome measures. Postoperative American Orthopaedic Foot & Ankle Society (AOFAS) hindfoot scale scores were also collected. All sixteen patients underwent radiographic and computed tomographic (CT) analyses preoperatively, and fifteen patients had these studies postoperatively. Results: The average duration of follow-up was 4.1 years. The latest follow-up CT evaluation identified failure of graft incorporation in two of sixteen ankles. Osteolysis, subchondral cysts, and degenerative changes were found in five, eight, and seven ankles, respectively. Five ankles were considered failures, and two required a reoperation because of ongoing symptoms. The AOS Disability and the AAOS Foot and Ankle Core Scale scores significantly improved, but there was no significant change in the AOS Pain, AAOS Foot and Ankle Shoe Comfort Scale, or SF-36 scores. Overall, ten patients had a good or excellent result; however, persistent symptoms remained in six of these patients. Only four were symptom-free. Conclusion: The use of a fresh osteochondral allograft is a reasonable option for the treatment of large talar osteochondral lesions. The high reoperation rate (two of seventeen) and failure rate (five of seventeen) must be taken into consideration when one is choosing this procedure for the management of these lesions. Level of Evidence: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence....
- 1 November 2009
- Published by Royal College of Surgeons of England in The Annals of The Royal College of Surgeons of England
- Vol. 91 (8) , 653-657
Reading the Small Print – Labelling Recommendations for Orthopaedic Implants
INTRODUCTION: There exist, currently, no clear guidelines regarding standards for surgical implant labelling. Dimensions of the laminar flow canopies in orthopaedic use fixes the distance at which implant labels can be read. Mistakes when reading the label on an implant box can pose health risks for patients, and financial consequences for medical institutions. SUBJECTS AND METHODS: Using scientifically validated tools such as the Snellen Chart Formula, a theoretical minimum standard for text on implant labels was reached. This theoretical standard was then tested under real operating conditions. After discovering a minimum practical standard for implant labels, the authors then audited current labels in use on a wide range of orthopaedic implant packages. Furthermore, other non-text-related labelling problems were also noted. RESULTS: There is a definite minimum standard which should be observed when implant labels are manufactured. Implants in current use bear labels on the packaging that are of an insufficient standard to ensure patient safety in theatre. CONCLUSIONS: The authors have established text parameters that will increase the legibility of implant labels. In the interests of improving risk management in theatre, therefore, the authors propose a standard for orthopaedic implant labelling, and believe this will provide a useful foundation for further discussion between the orthopaedic community and implant manufacturers.
- 1 November 2009
- Published by Royal College of Surgeons of England in The Annals of The Royal College of Surgeons of England
- Vol. 91 (8) , 653-657
Reading the Small Print – Labelling Recommendations for Orthopaedic Implants
INTRODUCTION: There exist, currently, no clear guidelines regarding standards for surgical implant labelling. Dimensions of the laminar flow canopies in orthopaedic use fixes the distance at which implant labels can be read. Mistakes when reading the label on an implant box can pose health risks for patients, and financial consequences for medical institutions. SUBJECTS AND METHODS: Using scientifically validated tools such as the Snellen Chart Formula, a theoretical minimum standard for text on implant labels was reached. This theoretical standard was then tested under real operating conditions. After discovering a minimum practical standard for implant labels, the authors then audited current labels in use on a wide range of orthopaedic implant packages. Furthermore, other non-text-related labelling problems were also noted. RESULTS: There is a definite minimum standard which should be observed when implant labels are manufactured. Implants in current use bear labels on the packaging that are of an insufficient standard to ensure patient safety in theatre. CONCLUSIONS: The authors have established text parameters that will increase the legibility of implant labels. In the interests of improving risk management in theatre, therefore, the authors propose a standard for orthopaedic implant labelling, and believe this will provide a useful foundation for further discussion between the orthopaedic community and implant manufacturers.
- 1 February 2007
- Published by British Editorial Society of Bone & Joint Surgery in The Journal of Bone and Joint Surgery. British volume
- Vol. 89-B (2) , 244-245
Hair tourniquet syndrome in an infant
An 11-week-old infant presented with swelling and discoloration of the left second toe because of hair thread tourniquet syndrome. This was treated by urgent surgical release of the constricting band, with a successful outcome. The authors stress the importance of recognising this rare condition and of prompt, complete, surgical release.
- 1 February 2007
- Published by British Editorial Society of Bone & Joint Surgery in The Journal of Bone and Joint Surgery. British volume
- Vol. 89-B (2) , 244-245
Hair tourniquet syndrome in an infant
An 11-week-old infant presented with swelling and discoloration of the left second toe because of hair thread tourniquet syndrome. This was treated by urgent surgical release of the constricting band, with a successful outcome. The authors stress the importance of recognising this rare condition and of prompt, complete, surgical release.