Andreas Mershin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Andreas Mershin has a total of 73 co-authors. Here are the top co-authors by number of shared publications:
Clifford Gluck
RealNose, www.realnose.ai, 626 Mass. Ave., 2nd Floor, Arlington, MA 02476, USA
3 shared publicationsHoward Kivell
RealNose, www.realnose.ai, 626 Mass. Ave., 2nd Floor, Arlington, MA 02476, USA
3 shared publicationsNikolas Stefanou
RealNose, www.realnose.ai, 626 Mass. Ave., 2nd Floor, Arlington, MA 02476, USA
3 shared publicationsRob Harris
Medical Detection Dogs, www.medicaldetectiondogs.org.uk, 3 Millfield Greenway Business Park, Winslow Road, Great Horwood, Milton Keynes MK17 0NP, UK
3 shared publicationsShuguang Zhang
RealNose, www.realnose.ai, 626 Mass. Ave., 2nd Floor, Arlington, MA 02476, USA
3 shared publicationsWen-Yee Lee
UTEP: The University of Texas at El Paso
3 shared publications
Latest Publications
- Open Access
GPCR-Based Machine Olfaction On Urine Scent Surpasses PSA at Predicting Prostate Cancer
Objectives: To determine whether medical machine olfaction via tracking the activation of mammalian G-Protein Coupled odorant Receptors (GPCR) stabilized by proprietary co-polymers on a photonic MZI chip can be used to diagnose prostate cancer (PCa) via urine scent. Specifically, scent character is compared against the current diagnostic PCa screening gold-standard in the US: the serum level of prostate specific antigen (PSA). The device is an artificial "nose" sensor built on a commercial photonic platform that reads interchangeable Mach-Zehnder interferometer (MZI) chips. These chips were functionalized with a stabilised panel of mammalian olfactory G-protein-coupled receptors (GPCRs). These samples had been characterized into POSITIVE or CONTROL for PCa several years earlier by standard hospital diagnostic procedures and by trained medical detection dogs, then stored by freezing at -80 Celcius. A subset of 80 patients’ urine samples was subsequently thawed and used for training and testing the medical machine olfaction system of RealNose as an initial validation of the novel technology and methodological approach. We posed two primary research questions: (a) whether the cancer-associated odor profile would remain detectable by machine-based systems following long-term storage and with what accuracy could it be used to cluster (YES and AUC 0.79 from scent character alone), and (b) what technical and procedural requirements would be necessary to translate such a signal into a clinically useful diagnostic assay (more training samples (500 predicted to yield 0.93) and increased breadth of receptors per chip and/or more chips per device in next iteration seen as helpful). Design, setting, participants: Retrospective diagnostic-accuracy feasibility study on 80 biobanked urine samples (40 PCa, 40 non-cancer; 368 sensor runs; a subset of unknown Gleason grade) from a single UK NHS urology service, the same collection used to train canine detectors. Main outcome measures: Patient-level Receiver Operating Characteristic (ROC) area under the curve (AUC) under patient-grouped cross-validation with a fold-honest pooled-control reference (reconstructed from training-partition controls only); sensitivity, specificity and predictive values at pre-specified operating points; 1000-fold whole-procedure label-permutation significance; patient bootstrap 95% CIs; and leave-one-day-out / leave-one-chip-out generalisation. Results: An L2-regularised linear classifier when allowed to see between three and six chips’ outcome on a patient sample extracted within-instrument AUC 0.79 (95% CI 0.69 to 0.88; 1000-permutation p = 0.001) from urine scent alone, exceeding this cohort’s own serum prostate-specific antigen (PSA) discrimination (AUC 0.645; itself within the population range for PSA, ≈0.67) and obtained without a blood draw (at the Youden point, sensitivity 0.75, specificity 0.78, PPV 0.77, NPV 0.76). This was not a plateau: AUC rose from chance at ∼30 samples, passed the serum-PSA range at ∼40, and reached 0.79 at 80 patients (0.82 if PSA was included , with an inverse-power fit projecting 0.93 by n ≈ 500 and 0.96 by n ≈ 1000. The discriminant was a genuine multivariate receptor pattern, independent of patient age (Spearman ρ ≈ 0.09; the cohort is not age-matched). So at least for these data, neither age, nor collection day, ambient humidity/temperature, or overall signal amplitude (sometimes thought of as intensity of smell) were predictive of prostate cancer status, yet the scent character was. Transfer to a new sensor chip fell to AUC 0.57 without calibration, meaning the remaining obstacles are hardware portability related rather than signal existence: much as a detection dog acclimatizes to a new setting, the system requires on-site calibration prior to use. Conclusions: A genuine, confound-controlled olfactory PCa signature is recoverable from 80 samples, surpasses this cohort’s serum PSA (0.645) and exceeds the population PSA range, and improves monotonically with training-set size. We present this as a small-sample feasibility benchmark, not yet a validated diagnostic; the dominant remaining factor is training-set size, and the path to clinical-utility and improved AUC is clearly found to be a larger, multi-site, age-matched, ideally prospective training cohort. A transferable small-sample lesson is also reported: adaptive feature searches (evolutionary and self-calibrating-protocol handle search) artificially inflate cross-validation and collapse under whole-procedure permutation, whereas non-adaptive averaging survives, giving a robust scent signal obtainable from the headspace of urine samples and recorable by the RealNose device that keeps improving with expanding sample training set. Study at a glance: Design: retrospective, single-batch diagnostic-accuracy feasibility study on a biobanked urine repository, reported per STARD 2015. Setting: a single UK NHS urology service (Milton Keynes University Hospital; Lancaster REC 15/NW/0527); specimens biobanked at −80◦C. Participants: 80 men undergoing urological investigation (40 biopsy-/clinically-confirmed prostate cancer, 40 noncancer controls); 368 sensor runs (mean 4.6/patient). Index test: RealNose GPCR-Mach-Zehnder interferometer urine-headspace “scent” readout via chips with four or eight types of mammalian human olfactory receptors functionalizing 64 available spots for Mach-Zehnder Interferometry measurements, scored by an L2-regularised linear classifier. Reference standard: histopathological (biopsy)/clinical diagnosis. Main outcome: patient-level area under the ROC curve (AUC) under patient-grouped cross-validation, with label-permutation significance and bootstrap confidence intervals.
Open AccessGPCR-Based Machine Olfaction On Urine Scent Surpasses PSA at Predicting Prostate Cancer
Objectives: To determine whether medical machine olfaction via tracking the activation of mammalian G-Protein Coupled odorant Receptors (GPCR) stabilized by proprietary co-polymers on a photonic MZI chip can be used to diagnose prostate cancer (PCa) via urine scent. Specifically, scent character is compared against the current diagnostic PCa screening gold-standard in the US: the serum level of prostate specific antigen (PSA). The device is an artificial "nose" sensor built on a commercial photonic platform that reads interchangeable Mach-Zehnder interferometer (MZI) chips. These chips were functionalized with a stabilised panel of mammalian olfactory G-protein-coupled receptors (GPCRs). These samples had been characterized into POSITIVE or CONTROL for PCa several years earlier by standard hospital diagnostic procedures and by trained medical detection dogs, then stored by freezing at -80 Celcius. A subset of 80 patients’ urine samples was subsequently thawed and used for training and testing the medical machine olfaction system of RealNose as an initial validation of the novel technology and methodological approach. We posed two primary research questions: (a) whether the cancer-associated odor profile would remain detectable by machine-based systems following long-term storage and with what accuracy could it be used to cluster (YES and AUC 0.79 from scent character alone), and (b) what technical and procedural requirements would be necessary to translate such a signal into a clinically useful diagnostic assay (more training samples (500 predicted to yield 0.93) and increased breadth of receptors per chip and/or more chips per device in next iteration seen as helpful). Design, setting, participants: Retrospective diagnostic-accuracy feasibility study on 80 biobanked urine samples (40 PCa, 40 non-cancer; 368 sensor runs; a subset of unknown Gleason grade) from a single UK NHS urology service, the same collection used to train canine detectors. Main outcome measures: Patient-level Receiver Operating Characteristic (ROC) area under the curve (AUC) under patient-grouped cross-validation with a fold-honest pooled-control reference (reconstructed from training-partition controls only); sensitivity, specificity and predictive values at pre-specified operating points; 1000-fold whole-procedure label-permutation significance; patient bootstrap 95% CIs; and leave-one-day-out / leave-one-chip-out generalisation. Results: An L2-regularised linear classifier when allowed to see between three and six chips’ outcome on a patient sample extracted within-instrument AUC 0.79 (95% CI 0.69 to 0.88; 1000-permutation p = 0.001) from urine scent alone, exceeding this cohort’s own serum prostate-specific antigen (PSA) discrimination (AUC 0.645; itself within the population range for PSA, ≈0.67) and obtained without a blood draw (at the Youden point, sensitivity 0.75, specificity 0.78, PPV 0.77, NPV 0.76). This was not a plateau: AUC rose from chance at ∼30 samples, passed the serum-PSA range at ∼40, and reached 0.79 at 80 patients (0.82 if PSA was included , with an inverse-power fit projecting 0.93 by n ≈ 500 and 0.96 by n ≈ 1000. The discriminant was a genuine multivariate receptor pattern, independent of patient age (Spearman ρ ≈ 0.09; the cohort is not age-matched). So at least for these data, neither age, nor collection day, ambient humidity/temperature, or overall signal amplitude (sometimes thought of as intensity of smell) were predictive of prostate cancer status, yet the scent character was. Transfer to a new sensor chip fell to AUC 0.57 without calibration, meaning the remaining obstacles are hardware portability related rather than signal existence: much as a detection dog acclimatizes to a new setting, the system requires on-site calibration prior to use. Conclusions: A genuine, confound-controlled olfactory PCa signature is recoverable from 80 samples, surpasses this cohort’s serum PSA (0.645) and exceeds the population PSA range, and improves monotonically with training-set size. We present this as a small-sample feasibility benchmark, not yet a validated diagnostic; the dominant remaining factor is training-set size, and the path to clinical-utility and improved AUC is clearly found to be a larger, multi-site, age-matched, ideally prospective training cohort. A transferable small-sample lesson is also reported: adaptive feature searches (evolutionary and self-calibrating-protocol handle search) artificially inflate cross-validation and collapse under whole-procedure permutation, whereas non-adaptive averaging survives, giving a robust scent signal obtainable from the headspace of urine samples and recorable by the RealNose device that keeps improving with expanding sample training set. Study at a glance: Design: retrospective, single-batch diagnostic-accuracy feasibility study on a biobanked urine repository, reported per STARD 2015. Setting: a single UK NHS urology service (Milton Keynes University Hospital; Lancaster REC 15/NW/0527); specimens biobanked at −80◦C. Participants: 80 men undergoing urological investigation (40 biopsy-/clinically-confirmed prostate cancer, 40 noncancer controls); 368 sensor runs (mean 4.6/patient). Index test: RealNose GPCR-Mach-Zehnder interferometer urine-headspace “scent” readout via chips with four or eight types of mammalian human olfactory receptors functionalizing 64 available spots for Mach-Zehnder Interferometry measurements, scored by an L2-regularised linear classifier. Reference standard: histopathological (biopsy)/clinical diagnosis. Main outcome: patient-level area under the ROC curve (AUC) under patient-grouped cross-validation, with label-permutation significance and bootstrap confidence intervals.
- Open Access
- 30 May 2025
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 20 (5) , e0314742
Towards robust medical machine olfaction: Debiasing GC-MS data enhances prostate cancer diagnosis from urine volatiles
Prostate cancer (PCa) is a major, and increasingly global, health concern with current screening and diagnostic tools’ severe limitations causing unnecessary, invasive biopsy procedures. While gas chromatography–mass spectrometry (GC-MS) has been used to detect urinary volatile organic compounds (VOCs) associated with PCa, efforts to identify consistent molecular biomarkers have failed to generalize across studies. Inspired by the olfactory diagnostic capabilities of medical detection dogs, we do not reduce chromatograms to a list of compounds and concentrations. Instead, we deploy a machine learning approach that bypasses molecular identification: PCa “scent character" signatures are extracted from raw time series data transformed into image representations for classification via convolutional neural networks. To address confounding factors such as sample-source bias, we implement a multi-step pre-processing and debiasing pipeline, including empirical Bayes correction, baseline drift removal, and domain adversarial learning. The resulting model achieves classification performance on par with similarly trained canines, achieving a recall of 88% and an F1-score of 0.78. These findings demonstrate that, at least in the context of PCa detection from urine, machine learning-based scent signature analysis can serve as a fully non-invasive diagnostic alternative, with these early results being also relevant to the wider emergent field of medical machine olfaction.
- 30 May 2025
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 20 (5) , e0314742
Open AccessTowards robust medical machine olfaction: Debiasing GC-MS data enhances prostate cancer diagnosis from urine volatiles
Prostate cancer (PCa) is a major, and increasingly global, health concern with current screening and diagnostic tools’ severe limitations causing unnecessary, invasive biopsy procedures. While gas chromatography–mass spectrometry (GC-MS) has been used to detect urinary volatile organic compounds (VOCs) associated with PCa, efforts to identify consistent molecular biomarkers have failed to generalize across studies. Inspired by the olfactory diagnostic capabilities of medical detection dogs, we do not reduce chromatograms to a list of compounds and concentrations. Instead, we deploy a machine learning approach that bypasses molecular identification: PCa “scent character" signatures are extracted from raw time series data transformed into image representations for classification via convolutional neural networks. To address confounding factors such as sample-source bias, we implement a multi-step pre-processing and debiasing pipeline, including empirical Bayes correction, baseline drift removal, and domain adversarial learning. The resulting model achieves classification performance on par with similarly trained canines, achieving a recall of 88% and an F1-score of 0.78. These findings demonstrate that, at least in the context of PCa detection from urine, machine learning-based scent signature analysis can serve as a fully non-invasive diagnostic alternative, with these early results being also relevant to the wider emergent field of medical machine olfaction.
- Open Access
Towards robust medical machine olfaction: debiasing GC-MS data enhances prostate cancer diagnosis from urine volatiles
Prostate cancer (PCa) is a major, and increasingly global, health concern with current screening and diagnostic tools’ severe limitations causing unnecessary, invasive biopsy procedures. While gas chromatography–mass spectrometry (GC-MS) has been used to detect urinary volatile organic compounds (VOCs) associated with PCa, efforts to identify consistent molecular biomarkers have failed to generalize across studies. Inspired by the olfactory diagnostic capabilities of medical detection dogs, we do not reduce chromatograms to a list of compounds and concentrations. Instead, we deploy a machine learning approach that bypasses molecular identification: PCa “scent character” signatures are extracted from raw time series data transformed into image representations for classification via convolutional neural networks. To address confounding factors such as sample-source bias, we implement a multi-step pre-processing and debiasing pipeline, including empirical Bayes correction, baseline drift removal, and domain adversarial learning. The resulting model achieves classification performance on par with similarly trained canines, achieving a recall of 88% and an F1-score of 0.78. These findings demonstrate that, at least in the context of PCa detection from urine, machine learning-based scent signature analysis can serve as a fully non-invasive diagnostic alternative, with these early results being also relevant to the wider emergent field of medical machine olfaction.
Open AccessTowards robust medical machine olfaction: debiasing GC-MS data enhances prostate cancer diagnosis from urine volatiles
Prostate cancer (PCa) is a major, and increasingly global, health concern with current screening and diagnostic tools’ severe limitations causing unnecessary, invasive biopsy procedures. While gas chromatography–mass spectrometry (GC-MS) has been used to detect urinary volatile organic compounds (VOCs) associated with PCa, efforts to identify consistent molecular biomarkers have failed to generalize across studies. Inspired by the olfactory diagnostic capabilities of medical detection dogs, we do not reduce chromatograms to a list of compounds and concentrations. Instead, we deploy a machine learning approach that bypasses molecular identification: PCa “scent character” signatures are extracted from raw time series data transformed into image representations for classification via convolutional neural networks. To address confounding factors such as sample-source bias, we implement a multi-step pre-processing and debiasing pipeline, including empirical Bayes correction, baseline drift removal, and domain adversarial learning. The resulting model achieves classification performance on par with similarly trained canines, achieving a recall of 88% and an F1-score of 0.78. These findings demonstrate that, at least in the context of PCa detection from urine, machine learning-based scent signature analysis can serve as a fully non-invasive diagnostic alternative, with these early results being also relevant to the wider emergent field of medical machine olfaction.
- Open Access
- 17 February 2021
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 16 (2) , e0245530
Feasibility of integrating canine olfaction with chemical and microbial profiling of urine to detect lethal prostate cancer
Prostate cancer is the second leading cause of cancer death in men in the developed world. A more sensitive and specific detection strategy for lethal prostate cancer beyond serum prostate specific antigen (PSA) population screening is urgently needed. Diagnosis by canine olfaction, using dogs trained to detect cancer by smell, has been shown to be both specific and sensitive. While dogs themselves are impractical as scalable diagnostic sensors, machine olfaction for cancer detection is testable. However, studies bridging the divide between clinical diagnostic techniques, artificial intelligence, and molecular analysis remains difficult due to the significant divide between these disciplines. We tested the clinical feasibility of a cross-disciplinary, integrative approach to early prostate cancer biosensing in urine using trained canine olfaction, volatile organic compound (VOC) analysis by gas chromatography-mass spectroscopy (GC-MS) artificial neural network (ANN)-assisted examination, and microbial profiling in a double-blinded pilot study. Two dogs were trained to detect Gleason 9 prostate cancer in urine collected from biopsy-confirmed patients. Biopsy-negative controls were used to assess canine specificity as prostate cancer biodetectors. Urine samples were simultaneously analyzed for their VOC content in headspace via GC-MS and urinary microbiota content via 16S rDNA Illumina sequencing. In addition, the dogs’ diagnoses were used to train an ANN to detect significant peaks in the GC-MS data. The canine olfaction system was 71% sensitive and between 70–76% specific at detecting Gleason 9 prostate cancer. We have also confirmed VOC differences by GC-MS and microbiota differences by 16S rDNA sequencing between cancer positive and biopsy-negative controls. Furthermore, the trained ANN identified regions of interest in the GC-MS data, informed by the canine diagnoses. Methodology and feasibility are established to inform larger-scale studies using canine olfaction, urinary VOCs, and urinary microbiota profiling to develop machine olfaction diagnostic tools. Scalable multi-disciplinary tools may then be compared to PSA screening for earlier, non-invasive, more specific and sensitive detection of clinically aggressive prostate cancers in urine samples.
- 17 February 2021
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 16 (2) , e0245530
Open AccessFeasibility of integrating canine olfaction with chemical and microbial profiling of urine to detect lethal prostate cancer
Prostate cancer is the second leading cause of cancer death in men in the developed world. A more sensitive and specific detection strategy for lethal prostate cancer beyond serum prostate specific antigen (PSA) population screening is urgently needed. Diagnosis by canine olfaction, using dogs trained to detect cancer by smell, has been shown to be both specific and sensitive. While dogs themselves are impractical as scalable diagnostic sensors, machine olfaction for cancer detection is testable. However, studies bridging the divide between clinical diagnostic techniques, artificial intelligence, and molecular analysis remains difficult due to the significant divide between these disciplines. We tested the clinical feasibility of a cross-disciplinary, integrative approach to early prostate cancer biosensing in urine using trained canine olfaction, volatile organic compound (VOC) analysis by gas chromatography-mass spectroscopy (GC-MS) artificial neural network (ANN)-assisted examination, and microbial profiling in a double-blinded pilot study. Two dogs were trained to detect Gleason 9 prostate cancer in urine collected from biopsy-confirmed patients. Biopsy-negative controls were used to assess canine specificity as prostate cancer biodetectors. Urine samples were simultaneously analyzed for their VOC content in headspace via GC-MS and urinary microbiota content via 16S rDNA Illumina sequencing. In addition, the dogs’ diagnoses were used to train an ANN to detect significant peaks in the GC-MS data. The canine olfaction system was 71% sensitive and between 70–76% specific at detecting Gleason 9 prostate cancer. We have also confirmed VOC differences by GC-MS and microbiota differences by 16S rDNA sequencing between cancer positive and biopsy-negative controls. Furthermore, the trained ANN identified regions of interest in the GC-MS data, informed by the canine diagnoses. Methodology and feasibility are established to inform larger-scale studies using canine olfaction, urinary VOCs, and urinary microbiota profiling to develop machine olfaction diagnostic tools. Scalable multi-disciplinary tools may then be compared to PSA screening for earlier, non-invasive, more specific and sensitive detection of clinically aggressive prostate cancers in urine samples.
- Open Access
Feasibility of Integrating Canine Olfaction with Chemical and Microbial Profiling of Urine to Detect Lethal Prostate Cancer
Prostate cancer is the second leading cause of cancer death in men in the developed world. A more sensitive and specific detection strategy for lethal prostate cancer beyond serum prostate specific antigen (PSA) population screening is urgently needed. Diagnosis by canine olfaction, using dogs trained to detect cancer by smell, has been shown to be both specific and sensitive. While dogs themselves are impractical as scalable diagnostic sensors, machine olfaction for cancer detection is testable. However, studies bridging the divide between clinical diagnostic techniques, artificial intelligence, and molecular analysis remains difficult due to the significant divide between these disciplines. We tested the clinical feasibility of a cross-disciplinary, integrative approach to early prostate cancer biosensing in urine using trained canine olfaction, volatile organic compound (VOC) analysis by gas chromatography-mass spectroscopy (GC-MS) artificial neural network (ANN)-assisted examination, and microbial profiling in a double-blinded pilot study. Two dogs were trained to detect Gleason 9 prostate cancer in urine collected from biopsy-confirmed patients. Biopsy-negative controls were used to assess canine specificity as prostate cancer biodetectors. Urine samples were simultaneously analyzed for their VOC content in headspace via GC-MS and urinary microbiota content via 16S rDNA Illumina sequencing. In addition, the dogs’ diagnoses were used to train an ANN to detect significant peaks in the GC-MS data. The canine olfaction system was 71% sensitive and between 70-76% specific at detecting Gleason 9 prostate cancer. We have also confirmed VOC differences by GC-MS and microbiota differences by 16S rDNA sequencing between cancer positive and biopsy-negative controls. Furthermore, the trained ANN identified regions of interest in the GC-MS data, informed by the canine diagnoses. Methodology and feasibility are established to inform larger-scale studies using canine olfaction, urinary VOCs, and urinary microbiota profiling to develop machine olfaction diagnostic tools. Scalable multi-disciplinary tools may then be compared to PSA screening for earlier, non-invasive, more specific and sensitive detection of clinically aggressive prostate cancers in urine samples.
Open AccessFeasibility of Integrating Canine Olfaction with Chemical and Microbial Profiling of Urine to Detect Lethal Prostate Cancer
Prostate cancer is the second leading cause of cancer death in men in the developed world. A more sensitive and specific detection strategy for lethal prostate cancer beyond serum prostate specific antigen (PSA) population screening is urgently needed. Diagnosis by canine olfaction, using dogs trained to detect cancer by smell, has been shown to be both specific and sensitive. While dogs themselves are impractical as scalable diagnostic sensors, machine olfaction for cancer detection is testable. However, studies bridging the divide between clinical diagnostic techniques, artificial intelligence, and molecular analysis remains difficult due to the significant divide between these disciplines. We tested the clinical feasibility of a cross-disciplinary, integrative approach to early prostate cancer biosensing in urine using trained canine olfaction, volatile organic compound (VOC) analysis by gas chromatography-mass spectroscopy (GC-MS) artificial neural network (ANN)-assisted examination, and microbial profiling in a double-blinded pilot study. Two dogs were trained to detect Gleason 9 prostate cancer in urine collected from biopsy-confirmed patients. Biopsy-negative controls were used to assess canine specificity as prostate cancer biodetectors. Urine samples were simultaneously analyzed for their VOC content in headspace via GC-MS and urinary microbiota content via 16S rDNA Illumina sequencing. In addition, the dogs’ diagnoses were used to train an ANN to detect significant peaks in the GC-MS data. The canine olfaction system was 71% sensitive and between 70-76% specific at detecting Gleason 9 prostate cancer. We have also confirmed VOC differences by GC-MS and microbiota differences by 16S rDNA sequencing between cancer positive and biopsy-negative controls. Furthermore, the trained ANN identified regions of interest in the GC-MS data, informed by the canine diagnoses. Methodology and feasibility are established to inform larger-scale studies using canine olfaction, urinary VOCs, and urinary microbiota profiling to develop machine olfaction diagnostic tools. Scalable multi-disciplinary tools may then be compared to PSA screening for earlier, non-invasive, more specific and sensitive detection of clinically aggressive prostate cancers in urine samples.
- Open Access
- 2 February 2012
- Published by Springer Nature in Scientific Reports
- Vol. 2 (1) , 234
Self-assembled photosystem-I biophotovoltaics on nanostructured TiO2 and ZnO
The abundant pigment-protein membrane complex photosystem-I (PS-I) is at the heart of the Earth’s energy cycle. It is the central molecule in the “Z-scheme” of photosynthesis, converting sunlight into the chemical energy of life. Commandeering this intricately organized photosynthetic nanocircuitry and re-wiring it to produce electricity carries the promise of inexpensive and environmentally friendly solar power. We here report that dry PS-I stabilized by surfactant peptides functioned as both the light-harvester and charge separator in solar cells self-assembled on nanostructured semiconductors. Contrary to previous attempts at biophotovoltaics requiring elaborate surface chemistries, thin film deposition, and illumination concentrated into narrow wavelength ranges the devices described here are straightforward and inexpensive to fabricate and perform well under standard sunlight yielding open circuit photovoltage of 0.5 V, fill factor of 71%, electrical power density of 81 µW/cm2 and photocurrent density of 362 µA/cm2, over four orders of magnitude higher than any photosystem-based biophotovoltaic to date.
- 2 February 2012
- Published by Springer Nature in Scientific Reports
- Vol. 2 (1) , 234
Open AccessSelf-assembled photosystem-I biophotovoltaics on nanostructured TiO2 and ZnO
The abundant pigment-protein membrane complex photosystem-I (PS-I) is at the heart of the Earth’s energy cycle. It is the central molecule in the “Z-scheme” of photosynthesis, converting sunlight into the chemical energy of life. Commandeering this intricately organized photosynthetic nanocircuitry and re-wiring it to produce electricity carries the promise of inexpensive and environmentally friendly solar power. We here report that dry PS-I stabilized by surfactant peptides functioned as both the light-harvester and charge separator in solar cells self-assembled on nanostructured semiconductors. Contrary to previous attempts at biophotovoltaics requiring elaborate surface chemistries, thin film deposition, and illumination concentrated into narrow wavelength ranges the devices described here are straightforward and inexpensive to fabricate and perform well under standard sunlight yielding open circuit photovoltage of 0.5 V, fill factor of 71%, electrical power density of 81 µW/cm2 and photocurrent density of 362 µA/cm2, over four orders of magnitude higher than any photosystem-based biophotovoltaic to date.
- Open Access
- 13 August 2008
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 3 (8) , e2963
Source of Sustained Voltage Difference between the Xylem of a Potted Ficus benjamina Tree and Its Soil
It has long been known that there is a sustained electrical potential (voltage) difference between the xylem of many plants and their surrounding soil, but the mechanism behind this voltage has remained controversial. After eliminating any extraneous capacitive or inductive couplings and ground-mediated electric current flows, we have measured sustained differences of 50–200 mV between the xylem region of a Faraday-caged, intact, potted Ficus benjamina tree and its soil, as well as between its cut branches and soils and ionic solutions standardized to various pH values. Using identical platinum electrodes, no correlation between the voltage and time of day, illumination, sap flow, electrode elevation, or ionic composition of soil was found, suggesting no direct connection to simple dissimilar-metal redox reactions or transpirational activity. Instead, a clear relationship between the voltage polarity and magnitude and the pH difference between xylem and soil was observed. We attribute these sustained voltages to a biological concentration cell likely set up by the homeostatic mechanisms of the tree. Potential applications of this finding are briefly explored.
- 13 August 2008
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 3 (8) , e2963
Open AccessSource of Sustained Voltage Difference between the Xylem of a Potted Ficus benjamina Tree and Its Soil
It has long been known that there is a sustained electrical potential (voltage) difference between the xylem of many plants and their surrounding soil, but the mechanism behind this voltage has remained controversial. After eliminating any extraneous capacitive or inductive couplings and ground-mediated electric current flows, we have measured sustained differences of 50–200 mV between the xylem region of a Faraday-caged, intact, potted Ficus benjamina tree and its soil, as well as between its cut branches and soils and ionic solutions standardized to various pH values. Using identical platinum electrodes, no correlation between the voltage and time of day, illumination, sap flow, electrode elevation, or ionic composition of soil was found, suggesting no direct connection to simple dissimilar-metal redox reactions or transpirational activity. Instead, a clear relationship between the voltage polarity and magnitude and the pH difference between xylem and soil was observed. We attribute these sustained voltages to a biological concentration cell likely set up by the homeostatic mechanisms of the tree. Potential applications of this finding are briefly explored.
- Open Access
Towards Experimental Tests of Quantum Effects in Cytoskeletal Proteins
It has become increasingly evident that fabrication of novel biomaterials through molecular self-assembly is going to play a significant role in material science and possibly the information technology of the future. Tubulin, microtubules (MTs) and the cytoskeleton are dynamic, self-assembling systems and we asked whether their structure and function contain the clues on how to fabricate biomolecular information processing devices. Here we review our neurobiological studies of transgenic Drosophila that strongly suggest the microtubular cytoskeleton is near the 'front lines' of intracellular information manipulation and storage. We also establish that spectroscopic techniques such as refractometry, surface plasmon resonance sensing and dielectric spectroscopy, coupled with molecular dynamic simulations and (quantum) electrodynamic analytical theory are useful tools in the study of the electrodynamic and possible quantum effects in cytoskeletal proteins. Implicit in our driving question is the possibility that if tubulin and MTs can indeed be cast as the basis of a classical or quantum computer, then perhaps nature has already done so and tubulin and MTs already play such a role in living neural and other cells. If quantum mechanics is found to be important in cellular function (through its involvement in proteins) it is natural to ask whether there are indeed quantum effects pertinent to consciousness. We conclude this work by suggesting a number of ways towards experimentally testing this "Quantum Consciousness Idea" (QCI), directly at the protein level.
Open AccessTowards Experimental Tests of Quantum Effects in Cytoskeletal Proteins
It has become increasingly evident that fabrication of novel biomaterials through molecular self-assembly is going to play a significant role in material science and possibly the information technology of the future. Tubulin, microtubules (MTs) and the cytoskeleton are dynamic, self-assembling systems and we asked whether their structure and function contain the clues on how to fabricate biomolecular information processing devices. Here we review our neurobiological studies of transgenic Drosophila that strongly suggest the microtubular cytoskeleton is near the 'front lines' of intracellular information manipulation and storage. We also establish that spectroscopic techniques such as refractometry, surface plasmon resonance sensing and dielectric spectroscopy, coupled with molecular dynamic simulations and (quantum) electrodynamic analytical theory are useful tools in the study of the electrodynamic and possible quantum effects in cytoskeletal proteins. Implicit in our driving question is the possibility that if tubulin and MTs can indeed be cast as the basis of a classical or quantum computer, then perhaps nature has already done so and tubulin and MTs already play such a role in living neural and other cells. If quantum mechanics is found to be important in cellular function (through its involvement in proteins) it is natural to ask whether there are indeed quantum effects pertinent to consciousness. We conclude this work by suggesting a number of ways towards experimentally testing this "Quantum Consciousness Idea" (QCI), directly at the protein level.
- 10 May 2005
- Published by Springer Nature
- p. 95-170
Towards Experimental Tests of Quantum Effects in Cytoskeletal Proteins
- 10 May 2005
- Published by Springer Nature
- p. 95-170
Towards Experimental Tests of Quantum Effects in Cytoskeletal Proteins