JKJoern W. Kuhbier

Joern W. Kuhbier

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Joern W. Kuhbier has a total of 18 co-authors. Here are the top co-authors by number of shared publications:

  • Christine Radtke

    Department of Plastic, Reconstructive and Aesthetic Surgery, Medical University of Vienna, Vienna, Austria

    3 shared publications
  • Cornelia Kasper

    Institute of Cell and Tissue Culture Technologies, University of Natural Resources and Life Sciences, Vienna, Austria

    3 shared publications
  • Kerstin Reimers

    Department of Plastic, Hand, and Reconstructive Surgery, Medical School Hannover, Carl‐Neuberg‐Strasse 1, 30625 Hannover, Germany

    3 shared publications
  • Peter M. Vogt

    Department of Plastic, Hand, and Reconstructive Surgery, Medical School Hannover, Carl‐Neuberg‐Strasse 1, 30625 Hannover, Germany

    3 shared publications
  • Anja Hillmer

    Department of Plastic, Hand, and Reconstructive Surgery, Medical School Hannover, Carl‐Neuberg‐Strasse 1, 30625 Hannover, Germany

    2 shared publications
  • Bjoern Menger

    2 shared publications

Latest Publications

  • Open Access

    Spider Silk-Augmented Scaffolds and Adipose-Derived Stromal Cells Loaded with Uniaxial Cyclic Strain: First Investigations of a Novel Approach for Tendon-Like Constructs

    by Frederik Schlottmann, Sarah Strauss, Christian Plaass, Bastian Welke, Peter M. Vogt, Joern W. Kuhbier

    Tendon injuries still pose a challenge to reconstructive surgeons. Tendon tissue is a bradytrophic tissue and has a poor tendency to heal. Autologous tendon grafts are, therefore, still the gold standard in restorative operations but are associated with significant donor side morbidity. The experimental approach of the present study focused on the use of the biomaterial spider silk as a biocompatible and very stable carrier matrix in combination with a collagen type I hydrogel and adipose-derived stromal cells. The constructs were differentiated by axial strain to tendon-like tissue using a custom-made bioreactor. Macroscopically, tendon-like tissue could be detected which histologically showed high cell vitality even in long-term cultivation. In addition, cell morphology comparable to tenocytes could be detected in the bioreactor-stimulated tendon-like constructs compared to the controls. Immunohistochemically, tendon tissue-specific markers could be detected. Therefore, the developed tendon-like construct represents a promising approach towards patient specific tendon reconstruction, but further studies are needed.


  • First investigation of spider silk as a braided microsurgical suture

    by Joern W. Kuhbier, Kerstin Reimers, Cornelia Kasper, Christina Allmeling, Anja Hillmer, Björn Menger, Peter M. Vogt, Christine Radtke

    Inhibition of axonal outgrowth accompanied by neuroma formation appears in microsurgical nerve repair as reaction to common microsuture materials like silk, nylon, or polyglycolic acid. In contrast, recent findings revealed advantages of spider silk fibers in guiding Schwann cells in nerve regeneration. Here, we asked if we could braid microsutures from native spider silk fibers. Microsutures braided of native spider dragline silk were manufactured, containing either 2 × 15 or 3 × 10 single fibres strands. Morphologic appearance was studied and tensile strength and stress‐strain ratio (SSR) were calculated. The constructed spider silk sutures showed a median thickness of 25 μm, matching the USP definition of 10‐0. Maximum load and tensile strength for both spider silk microsutures were significantly more than 2‐fold higher than for nylon suture; SSR was 1.5‐fold higher. All values except elasticity were higher in 3 × 10 strand sutures compared to 2 × 15 strand sutures, but not significantly. In this pilot study, we demonstrate the successful manufacture of microsutures from spider silk. With regards to the mechanical properties, these sutures were superior to nylon sutures. As spider silk displays high biocompatibility in nerve regeneration, its usage in microsurgical nerve repair should be considered. © 2011 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2011.


  • A novel and inexpensive retractor individually usable for microsurgical training

    by Joern W. Kuhbier, Kerstin Reimers, Bjoern Menger, Heiko Sorg, Peter M. Vogt, Christine Radtke


  • Open Access

    Interactions between Spider Silk and Cells – NIH/3T3 Fibroblasts Seeded on Miniature Weaving Frames

    by Joern W. Kuhbier, Christina Allmeling, Kerstin Reimers, Anja Hillmer, Cornelia Kasper, Bjoern Menger, Gudrun Brandes, Merlin Guggenheim, Peter M. Vogt

    Several materials have been used for tissue engineering purposes, since the ideal matrix depends on the desired tissue. Silk biomaterials have come to focus due to their great mechanical properties. As untreated silkworm silk has been found to be quite immunogenic, an alternative could be spider silk. Not only does it own unique mechanical properties, its biocompatibility has been shown already in vivo. In our study, we used native spider dragline silk which is known as the strongest fibre in nature. Steel frames were originally designed and manufactured and woven with spider silk, harvesting dragline silk directly out of the animal. After sterilization, scaffolds were seeded with fibroblasts to analyse cell proliferation and adhesion. Analysis of cell morphology and actin filament alignment clearly revealed adherence. Proliferation was measured by cell count as well as determination of relative fluorescence each after 1, 2, 3, and 5 days. Cell counts for native spider silk were also compared with those for trypsin-digested spider silk. Spider silk specimens displayed less proliferation than collagen- and fibronectin-coated cover slips, enzymatic treatment reduced adhesion and proliferation rates tendentially though not significantly. Nevertheless, proliferation could be proven with high significance (p<0.01). Native spider silk does not require any modification to its application as a biomaterial that can rival any artificial material in terms of cell growth promoting properties. We could show adhesion mechanics on intracellular level. Additionally, proliferation kinetics were higher than in enzymatically digested controls, indicating that spider silk does not require modification. Recent findings concerning reduction of cell proliferation after exposure could not be met. As biotechnological production of the hierarchical composition of native spider silk fibres is still a challenge, our study has a pioneer role in researching cellular mechanics on native spider silk fibres.


  • Isolation, Characterization, Differentiation, and Application of Adipose-Derived Stem Cells

    by Jörn W. Kuhbier, Birgit Weyand, Christine Radtke, Peter M. Vogt, Cornelia Kasper, Kerstin Reimers

    While bone marrow-derived mesenchymal stem cells are known and have been investigated for a long time, mesenchymal stem cells derived from the adipose tissue were identified as such by Zuk et al. in 2001. However, as subcutaneous fat tissue is a rich source which is much more easily accessible than bone marrow and thus can be reached by less invasive procedures, adipose-derived stem cells have moved into the research spotlight over the last 8 years. Isolation of stromal cell fractions involves centrifugation, digestion, and filtration, resulting in an adherent cell population containing mesenchymal stem cells; these can be subdivided by cell sorting and cultured under common conditions. They seem to have comparable properties to bone marrow-derived mesenchymal stem cells in their differentiation abilities as well as a favorable angiogenic and anti-inflammatory cytokine secretion profile and therefore have become widely used in tissue engineering and clinical regenerative medicine.