ADAmro Daboul

Amro Daboul

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Amro Daboul has a total of 12 co-authors. Here are the top co-authors by number of shared publications:

  • Ahmad Al Jaghsi

    Clinical Sciences Department, College of Dentistry, Ajman University, Ajman, United Arab Emirates

    2 shared publications
  • Ralf Puls

    Institute of Diagnostics, Radiology and Neuroradiology, Greifswald University, Greifswald, Germany

    2 shared publications
  • Reiner Biffar

    Polyclinic of Prosthodontics and Biomaterials, Greifswald University, Greifswald, Germany

    2 shared publications
  • Thomas Klinke

    Polyclinic of Prosthodontics and Biomaterials, Greifswald University, Greifswald, Germany

    2 shared publications
  • Christian Schwahn

    Polyclinic of Prosthodontics and Biomaterials, Greifswald University, Greifswald, Germany

    1 shared publication
  • Grit Schaffner

    Polyclinic of Prosthodontics and Biomaterials, Greifswald University, Greifswald, Germany

    1 shared publication

Latest Publications

  • Open Access

    Reproducibility of Frankfort Horizontal Plane on 3D Multi-Planar Reconstructed MR Images

    by Amro Daboul, Christian Schwahn, Grit Schaffner, Silvia Soehnel, Stefanie Samietz, Ahmad Aljaghsi, Mohammad Habes, Katrin Hegenscheid, Ralf Puls, Thomas Klinke, et al.

    The purpose of this study was to determine the accuracy and reliability of Frankfort horizontal plane identification using displays of multi-planar reconstructed MRI images, and propose it as a sufficiently stable and standardized reference plane for craniofacial structures. MRI images of 43 subjects were obtained from the longitudinal population based cohort study SHIP-2 using a T1-weighted 3D sequence. Five examiners independently identified the three landmarks that form FH plane. Intra-examiner reproducibility and inter-examiner reliability, correlation coefficients (ICC), coefficient of variability and Bland-Altman plots were obtained for all landmarks coordinates to assess reproducibility. Intra-examiner reproducibility and inter-examiner reliability in terms of location and plane angulation were also assessed. Intra- and inter-examiner reliabilities for X, Y and Z coordinates of all three landmarks were excellent with ICC values ranging from 0.914 to 0.998. Differences among examiners were more in X and Z than in Y dimensions. The Bland–Altman analysis demonstrated excellent intra- as well as inter-examiner agreement between examiners in all coordinates for all landmarks. Intra-examiner reproducibility and inter-examiner reliability of the three landmarks in terms of distance showed mean differences between 1.3 to 2.9 mm, Mean differences in plane angulation were between 1.0° to 1.5° among examiners. This study revealed excellent intra-examiner reproducibility and inter-examiner reliability of Frankfort Horizontal plane through 3D landmark identification in MRI. Sufficiently stable landmark-based reference plane could be used for different treatments and studies.


  • Open Access

    Artifacts In Magnetic Resonance Imaging and Computed Tomography Caused By Dental Materials

    by Thomas Klinke, Amro Daboul, Juliane Maron, Tomasz Gredes, Ralf Puls, Ahmad Jaghsi, Reiner Biffar

    Artifacts caused by dental restorations, such as dental crowns, dental fillings and orthodontic appliances, are a common problem in MRI and CT scans of the head and neck. The aim of this in-vitro study was to identify and evaluate the artifacts produced by different dental restoration materials in CT and MRI images. Test samples of 44 materials (Metal and Non-Metal) commonly used in dental restorations were fabricated and embedded with reference specimens in gelatin moulds. MRI imaging of 1.5T and CT scan were performed on the samples and evaluated in two dimensions. Artifact size and distortions were measured using a digital image analysis software. In MRI, 13 out of 44 materials produced artifacts, while in CT 41 out of 44 materials showed artifacts. Artifacts produced in both MRI and CT images were categorized according to the size of the artifact. Metal based restoration materials had strong influence on CT and less artifacts in MRI images. Rare earth elements such as Ytterbium trifluoride found in composites caused artifacts in both MRI and CT. Recognizing these findings would help dental materials manufacturers and developers to produce materials which can cause less artifacts in MRI and CT images.