Ralph S. DaCosta
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ralph S. DaCosta has a total of 80 co-authors. Here are the top co-authors by number of shared publications:
Azusa Maeda
Princess Margaret Cancer Centre, University Health Network, Toronto, Ontario, Canada; Department of Medical Biophysics, University of Toronto, Toronto, Ontario, Canada
6 shared publicationsJiachuan Bu
Princess Margaret Cancer Centre, University Health Network, Toronto, Ontario, Canada
4 shared publicationsYonghong Chen
Princess Margaret Cancer Centre, University Health Network, Toronto, Ontario, Canada
4 shared publications- Brian Campbell Wilson
Department of Medical Biophysics, University Health Network, University of Toronto, Toronto, ON M5G 1L7, Canada
3 shared publications Danielle Starr
Princess Margaret Cancer Centre and Techna Institute, University Health Network, Toronto, Canada
2 shared publications- David Anthony Jaffray
The University of Texas MD Anderson Cancer Center, Houston, TX
2 shared publications
Latest Publications
- 1 January 2017
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 97 (1) , 184-194
In Vivo Imaging Reveals Significant Tumor Vascular Dysfunction and Increased Tumor Hypoxia-Inducible Factor-1α Expression Induced by High Single-Dose Irradiation in a Pancreatic Tumor Model
- 1 January 2017
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 97 (1) , 184-194
In Vivo Imaging Reveals Significant Tumor Vascular Dysfunction and Increased Tumor Hypoxia-Inducible Factor-1α Expression Induced by High Single-Dose Irradiation in a Pancreatic Tumor Model
- Open Access
- 21 October 2016
- Published by Frontiers Media SA in Frontiers in Oncology
- Vol. 6, 221
The Necrosis-Avid Small Molecule HQ4-DTPA as a Multimodal Imaging Agent for Monitoring Radiation Therapy-Induced Tumor Cell Death
Purpose: Most effective antitumor therapies induce tumor cell death. Non-invasive, rapid and accurate quantitative imaging of cell death is essential for monitoring early response to antitumor therapies. To facilitate this, we previously developed a biocompatible necrosis-avid near-infrared fluorescence (NIRF) imaging probe, HQ4, which was radiolabelled with 111Indium-chloride (111In-Cl3) via the chelate diethylene triamine pentaacetic acid (DTPA), to enable clinical translation. The aim of the present study was to evaluate the application of HQ4-DTPA for monitoring tumor cell death induced by radiation therapy. Apart from its NIRF and radioactive properties, HQ4-DTPA was also tested as a photoacoustic imaging probe to evaluate its performance as a multimodal contrast agent for superficial and deep tissue imaging. Material/Methods: Radiation-induced tumor cell death was examined in a xenograft mouse model of human breast cancer (MCF7). Tumors were irradiated with three fractions of 9 Gy each. HQ4-DTPA was injected intravenously after the last irradiation, NIRF and photoacoustic imaging of the tumors were performed at 12, 20 and 40 h after injection. Changes in probe accumulation in the tumors were measured in vivo, and ex vivo histological analysis of excised tumors was performed at experimental endpoints. In addition, biodistribution of radiolabeled [111In]DTPA-HQ4 was assessed using hybrid single-photon emission computed tomography-computed tomography (SPECT-CT) at the same time points. Results: In vivo NIRF imaging demonstrated a significant difference in probe accumulation between control and irradiated tumors at all time points after injection. A similar trend was observed using in vivo photoacoustic imaging, which was validated by ex vivo tissue fluorescence and photoacoustic imaging. Serial quantitative radioactivity measurements of probe biodistribution further demonstrated increased probe accumulation in irradiated tumors. Conclusion: HQ4-DTPA has high specificity for dead cells in vivo, potentiating its use as a contrast agent for determining the relative level of tumor cell death following radiation therapy using NIRF, photoacoustic imaging and SPECT in vivo. Initial preclinical results are promising and indicate the need for further evaluation in larger cohorts. If successful, such studies may help develop a new multimodal method for non-invasive and dynamic deep-tissue imaging of treatment-induced cell death to quantitatively assess therapeutic response in patients.
- 21 October 2016
- Published by Frontiers Media SA in Frontiers in Oncology
- Vol. 6, 221
Open AccessThe Necrosis-Avid Small Molecule HQ4-DTPA as a Multimodal Imaging Agent for Monitoring Radiation Therapy-Induced Tumor Cell Death
Purpose: Most effective antitumor therapies induce tumor cell death. Non-invasive, rapid and accurate quantitative imaging of cell death is essential for monitoring early response to antitumor therapies. To facilitate this, we previously developed a biocompatible necrosis-avid near-infrared fluorescence (NIRF) imaging probe, HQ4, which was radiolabelled with 111Indium-chloride (111In-Cl3) via the chelate diethylene triamine pentaacetic acid (DTPA), to enable clinical translation. The aim of the present study was to evaluate the application of HQ4-DTPA for monitoring tumor cell death induced by radiation therapy. Apart from its NIRF and radioactive properties, HQ4-DTPA was also tested as a photoacoustic imaging probe to evaluate its performance as a multimodal contrast agent for superficial and deep tissue imaging. Material/Methods: Radiation-induced tumor cell death was examined in a xenograft mouse model of human breast cancer (MCF7). Tumors were irradiated with three fractions of 9 Gy each. HQ4-DTPA was injected intravenously after the last irradiation, NIRF and photoacoustic imaging of the tumors were performed at 12, 20 and 40 h after injection. Changes in probe accumulation in the tumors were measured in vivo, and ex vivo histological analysis of excised tumors was performed at experimental endpoints. In addition, biodistribution of radiolabeled [111In]DTPA-HQ4 was assessed using hybrid single-photon emission computed tomography-computed tomography (SPECT-CT) at the same time points. Results: In vivo NIRF imaging demonstrated a significant difference in probe accumulation between control and irradiated tumors at all time points after injection. A similar trend was observed using in vivo photoacoustic imaging, which was validated by ex vivo tissue fluorescence and photoacoustic imaging. Serial quantitative radioactivity measurements of probe biodistribution further demonstrated increased probe accumulation in irradiated tumors. Conclusion: HQ4-DTPA has high specificity for dead cells in vivo, potentiating its use as a contrast agent for determining the relative level of tumor cell death following radiation therapy using NIRF, photoacoustic imaging and SPECT in vivo. Initial preclinical results are promising and indicate the need for further evaluation in larger cohorts. If successful, such studies may help develop a new multimodal method for non-invasive and dynamic deep-tissue imaging of treatment-induced cell death to quantitatively assess therapeutic response in patients.
- 1 August 2016
- Published by SAGE Publications in Advances in Wound Care
- Vol. 5 (8) , 329-331
Can Imaging Put the “ Advanced” Back in Advanced Wound Care?
An effective, scientifically validated, diagnostic tool helps clinicians make better, timely, and more objective medical decisions in the care of their patients. Today, the need for such tools is especially urgent in the field of wound care where patient-centric care is the goal, under ever tightening clinical budget constraints. In an era of countless “innovative” treatment options, that is, advanced dressings, negative pressure devices, and various debridement instruments available to the wound care clinical team, one area that has arguably languished in the past decade has been innovation in wound diagnostics. Whereas medical imaging is a mainstay in the diagnostic toolkit across many other medical fields (oncology, neurology, gastroenterology, orthopedics, etc.), the field of wound care has yet to realize the full potential that advances in imaging technologies have to offer the clinician. In this issue, the first of a series in wound imaging and diagnostics, four articles have been assembled, highlighting some of the recent advances in wound imaging technologies.
- 1 August 2016
- Published by SAGE Publications in Advances in Wound Care
- Vol. 5 (8) , 329-331
Can Imaging Put the “ Advanced” Back in Advanced Wound Care?
An effective, scientifically validated, diagnostic tool helps clinicians make better, timely, and more objective medical decisions in the care of their patients. Today, the need for such tools is especially urgent in the field of wound care where patient-centric care is the goal, under ever tightening clinical budget constraints. In an era of countless “innovative” treatment options, that is, advanced dressings, negative pressure devices, and various debridement instruments available to the wound care clinical team, one area that has arguably languished in the past decade has been innovation in wound diagnostics. Whereas medical imaging is a mainstay in the diagnostic toolkit across many other medical fields (oncology, neurology, gastroenterology, orthopedics, etc.), the field of wound care has yet to realize the full potential that advances in imaging technologies have to offer the clinician. In this issue, the first of a series in wound imaging and diagnostics, four articles have been assembled, highlighting some of the recent advances in wound imaging technologies.
- 22 April 2015
- Published by Wiley in International Wound Journal
- Vol. 13 (4) , 449-453
Handheld fluorescence imaging device detects subclinical wound infection in an asymptomatic patient with chronic diabetic foot ulcer: a case report
Chronic wounds are a significant burden to global patient and health care infrastructures, and there is a need for better methods of early wound diagnosis and treatment. Traditional diagnosis of chronic wound infection by pathogenic bacteria, using clinical signs and symptoms, is based on visual inspection under white light and microbiological sampling (e.g. swabbing and/or biopsy) of the wound, which are subjective and suboptimal. Diagnosing microbial infection based on traditional clinical signs and symptoms in wounds of asymptomatic patients is especially challenging at the bedside. Bacteria are invisible to the unaided eye and wound sampling for diagnostic testing can cause unacceptable delays in diagnosis and treatment. To address this problem, we developed a new prototype handheld, portable fluorescence imaging device that enables non‐contact, real‐time, high‐resolution visualisation of pathogenic bacteria and tissues in wounds. Herein, we report the clinical use of this imaging device in detecting subsurface heavy bacterial load and subclinical local infection in an asymptomatic 50‐year‐old patient with a non‐healing diabetic foot ulcer.
- 22 April 2015
- Published by Wiley in International Wound Journal
- Vol. 13 (4) , 449-453
Handheld fluorescence imaging device detects subclinical wound infection in an asymptomatic patient with chronic diabetic foot ulcer: a case report
Chronic wounds are a significant burden to global patient and health care infrastructures, and there is a need for better methods of early wound diagnosis and treatment. Traditional diagnosis of chronic wound infection by pathogenic bacteria, using clinical signs and symptoms, is based on visual inspection under white light and microbiological sampling (e.g. swabbing and/or biopsy) of the wound, which are subjective and suboptimal. Diagnosing microbial infection based on traditional clinical signs and symptoms in wounds of asymptomatic patients is especially challenging at the bedside. Bacteria are invisible to the unaided eye and wound sampling for diagnostic testing can cause unacceptable delays in diagnosis and treatment. To address this problem, we developed a new prototype handheld, portable fluorescence imaging device that enables non‐contact, real‐time, high‐resolution visualisation of pathogenic bacteria and tissues in wounds. Herein, we report the clinical use of this imaging device in detecting subsurface heavy bacterial load and subclinical local infection in an asymptomatic 50‐year‐old patient with a non‐healing diabetic foot ulcer.
- Open Access
- 19 March 2015
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 10 (3) , e0116623
Point-of-Care Autofluorescence Imaging for Real-Time Sampling and Treatment Guidance of Bioburden in Chronic Wounds: First-in-Human Results
Traditionally, chronic wound infection is diagnosed by visual inspection under white light and microbiological sampling, which are subjective and suboptimal, respectively, thereby delaying diagnosis and treatment. To address this, we developed a novel handheld, fluorescence imaging device (PRODIGI) that enables non-contact, real-time, high-resolution visualization and differentiation of key pathogenic bacteria through their endogenous autofluorescence, as well as connective tissues in wounds. This was a two-part Phase I, single center, non-randomized trial of chronic wound patients (male and female, ≥18 years; UHN REB #09-0015-A for part 1; UHN REB #12-5003 for part 2; clinicaltrials.gov Identifier: NCT01378728 for part 1 and NCT01651845 for part 2). Part 1 (28 patients; 54% diabetic foot ulcers, 46% non-diabetic wounds) established the feasibility of autofluorescence imaging to accurately guide wound sampling, validated against blinded, gold standard swab-based microbiology. Part 2 (12 patients; 83.3% diabetic foot ulcers, 16.7% non-diabetic wounds) established the feasibility of autofluorescence imaging to guide wound treatment and quantitatively assess treatment response. We showed that PRODIGI can be used to guide and improve microbiological sampling and debridement of wounds in situ, enabling diagnosis, treatment guidance and response assessment in patients with chronic wounds. PRODIGI is safe, easy to use and integrates into the clinical workflow. Clinically significant bacterial burden can be detected in seconds, quantitatively tracked over days-to-months and their biodistribution mapped within the wound bed, periphery, and other remote areas. PRODIGI represents a technological advancement in wound sampling and treatment guidance for clinical wound care at the point-of-care. ClinicalTrials.gov NCT01651845; ClinicalTrials.gov NCT01378728
- 19 March 2015
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 10 (3) , e0116623
Open AccessPoint-of-Care Autofluorescence Imaging for Real-Time Sampling and Treatment Guidance of Bioburden in Chronic Wounds: First-in-Human Results
Traditionally, chronic wound infection is diagnosed by visual inspection under white light and microbiological sampling, which are subjective and suboptimal, respectively, thereby delaying diagnosis and treatment. To address this, we developed a novel handheld, fluorescence imaging device (PRODIGI) that enables non-contact, real-time, high-resolution visualization and differentiation of key pathogenic bacteria through their endogenous autofluorescence, as well as connective tissues in wounds. This was a two-part Phase I, single center, non-randomized trial of chronic wound patients (male and female, ≥18 years; UHN REB #09-0015-A for part 1; UHN REB #12-5003 for part 2; clinicaltrials.gov Identifier: NCT01378728 for part 1 and NCT01651845 for part 2). Part 1 (28 patients; 54% diabetic foot ulcers, 46% non-diabetic wounds) established the feasibility of autofluorescence imaging to accurately guide wound sampling, validated against blinded, gold standard swab-based microbiology. Part 2 (12 patients; 83.3% diabetic foot ulcers, 16.7% non-diabetic wounds) established the feasibility of autofluorescence imaging to guide wound treatment and quantitatively assess treatment response. We showed that PRODIGI can be used to guide and improve microbiological sampling and debridement of wounds in situ, enabling diagnosis, treatment guidance and response assessment in patients with chronic wounds. PRODIGI is safe, easy to use and integrates into the clinical workflow. Clinically significant bacterial burden can be detected in seconds, quantitatively tracked over days-to-months and their biodistribution mapped within the wound bed, periphery, and other remote areas. PRODIGI represents a technological advancement in wound sampling and treatment guidance for clinical wound care at the point-of-care. ClinicalTrials.gov NCT01651845; ClinicalTrials.gov NCT01378728
- Open Access
- 1 January 2015
- Published by SAGE Publications in Molecular Imaging
- Vol. 14 (1)
Dual in vivo Photoacoustic and Fluorescence Imaging of HER2 Expression in Breast Tumors for Diagnosis, Margin Assessment, and Surgical Guidance
Biomarker-specific imaging probes offer ways to improve molecular diagnosis, intraoperative margin assessment, and tumor resection. Fluorescence and photoacoustic imaging probes are of particular interest for clinical applications because the combination enables deeper tissue penetration for tumor detection while maintaining imaging sensitivity compared to a single optical imaging modality. Here we describe the development of a human epidermal growth factor receptor 2 (HER2)-targeting imaging probe to visualize differential levels of HER2 expression in a breast cancer model. Specifically, we labeled trastuzumab with Black Hole Quencher 3 (BHQ3) and fluorescein for photoacoustic and fluorescence imaging of HER2 overexpression, respectively. The dual-labeled trastuzumab was tested for its ability to detect HER2 overexpression in vitro and in vivo. We demonstrated an over twofold increase in the signal intensity for HER2-overexpressing tumors in vivo, compared to low–HER2-expressing tumors, using photoacoustic imaging. Furthermore, we demonstrated the feasibility of detecting tumors and positive surgical margins by fluorescence imaging. These results suggest that multimodal HER2-specific imaging of breast cancer using the BHQ3-fluorescein trastuzumab enables molecular-level detection and surgical margin assessment of breast tumors in vivo. This technique may have future clinical impact for primary lesion detection, as well as intraoperative molecular-level surgical guidance in breast cancer.
- 1 January 2015
- Published by SAGE Publications in Molecular Imaging
- Vol. 14 (1)
Open AccessDual in vivo Photoacoustic and Fluorescence Imaging of HER2 Expression in Breast Tumors for Diagnosis, Margin Assessment, and Surgical Guidance
Biomarker-specific imaging probes offer ways to improve molecular diagnosis, intraoperative margin assessment, and tumor resection. Fluorescence and photoacoustic imaging probes are of particular interest for clinical applications because the combination enables deeper tissue penetration for tumor detection while maintaining imaging sensitivity compared to a single optical imaging modality. Here we describe the development of a human epidermal growth factor receptor 2 (HER2)-targeting imaging probe to visualize differential levels of HER2 expression in a breast cancer model. Specifically, we labeled trastuzumab with Black Hole Quencher 3 (BHQ3) and fluorescein for photoacoustic and fluorescence imaging of HER2 overexpression, respectively. The dual-labeled trastuzumab was tested for its ability to detect HER2 overexpression in vitro and in vivo. We demonstrated an over twofold increase in the signal intensity for HER2-overexpressing tumors in vivo, compared to low–HER2-expressing tumors, using photoacoustic imaging. Furthermore, we demonstrated the feasibility of detecting tumors and positive surgical margins by fluorescence imaging. These results suggest that multimodal HER2-specific imaging of breast cancer using the BHQ3-fluorescein trastuzumab enables molecular-level detection and surgical margin assessment of breast tumors in vivo. This technique may have future clinical impact for primary lesion detection, as well as intraoperative molecular-level surgical guidance in breast cancer.
- Open Access
- 1 January 2014
- Published by Taylor & Francis in IntraVital
- Vol. 3 (1) , e27935
Optimization of the dorsal skinfold window chamber model and multi-parametric characterization of tumor-associated vasculature
The dorsal skinfold window chamber (DSWC) model is a unique tool that enables analysis of various aspects of tumor biology and therapeutic response. Although the protocol for the murine DSWC model is standardized, certain tumors fail to grow or require a particular environment to promote growth. Given such limitations, we optimized the DSWC model for a slow-growing tumor that regresses spontaneously in the standard protocol. We further characterized the vascular network in the tumor model compared with that of non-tumor-bearing mice and observed significant differences in multiple parameters related to vascular structure and function.
- 1 January 2014
- Published by Taylor & Francis in IntraVital
- Vol. 3 (1) , e27935
Open AccessOptimization of the dorsal skinfold window chamber model and multi-parametric characterization of tumor-associated vasculature
The dorsal skinfold window chamber (DSWC) model is a unique tool that enables analysis of various aspects of tumor biology and therapeutic response. Although the protocol for the murine DSWC model is standardized, certain tumors fail to grow or require a particular environment to promote growth. Given such limitations, we optimized the DSWC model for a slow-growing tumor that regresses spontaneously in the standard protocol. We further characterized the vascular network in the tumor model compared with that of non-tumor-bearing mice and observed significant differences in multiple parameters related to vascular structure and function.
- Open Access
- 14 March 2013
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 8 (3) , e58081
A Spinal Cord Window Chamber Model for In Vivo Longitudinal Multimodal Optical and Acoustic Imaging in a Murine Model
In vivo and direct imaging of the murine spinal cord and its vasculature using multimodal (optical and acoustic) imaging techniques could significantly advance preclinical studies of the spinal cord. Such intrinsically high resolution and complementary imaging technologies could provide a powerful means of quantitatively monitoring changes in anatomy, structure, physiology and function of the living cord over time after traumatic injury, onset of disease, or therapeutic intervention. However, longitudinal in vivo imaging of the intact spinal cord in rodent models has been challenging, requiring repeated surgeries to expose the cord for imaging or sacrifice of animals at various time points for ex vivo tissue analysis. To address these limitations, we have developed an implantable spinal cord window chamber (SCWC) device and procedures in mice for repeated multimodal intravital microscopic imaging of the cord and its vasculature in situ. We present methodology for using our SCWC to achieve spatially co-registered optical-acoustic imaging performed serially for up to four weeks, without damaging the cord or induction of locomotor deficits in implanted animals. To demonstrate the feasibility, we used the SCWC model to study the response of the normal spinal cord vasculature to ionizing radiation over time using white light and fluorescence microscopy combined with optical coherence tomography (OCT) in vivo. In vivo power Doppler ultrasound and photoacoustics were used to directly visualize the cord and vascular structures and to measure hemoglobin oxygen saturation through the complete spinal cord, respectively. The model was also used for intravital imaging of spinal micrometastases resulting from primary brain tumor using fluorescence and bioluminescence imaging. Our SCWC model overcomes previous in vivo imaging challenges, and our data provide evidence of the broader utility of hybridized optical-acoustic imaging methods for obtaining multiparametric and rich imaging data sets, including over extended periods, for preclinical in vivo spinal cord research.
- 14 March 2013
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 8 (3) , e58081
Open AccessA Spinal Cord Window Chamber Model for In Vivo Longitudinal Multimodal Optical and Acoustic Imaging in a Murine Model
In vivo and direct imaging of the murine spinal cord and its vasculature using multimodal (optical and acoustic) imaging techniques could significantly advance preclinical studies of the spinal cord. Such intrinsically high resolution and complementary imaging technologies could provide a powerful means of quantitatively monitoring changes in anatomy, structure, physiology and function of the living cord over time after traumatic injury, onset of disease, or therapeutic intervention. However, longitudinal in vivo imaging of the intact spinal cord in rodent models has been challenging, requiring repeated surgeries to expose the cord for imaging or sacrifice of animals at various time points for ex vivo tissue analysis. To address these limitations, we have developed an implantable spinal cord window chamber (SCWC) device and procedures in mice for repeated multimodal intravital microscopic imaging of the cord and its vasculature in situ. We present methodology for using our SCWC to achieve spatially co-registered optical-acoustic imaging performed serially for up to four weeks, without damaging the cord or induction of locomotor deficits in implanted animals. To demonstrate the feasibility, we used the SCWC model to study the response of the normal spinal cord vasculature to ionizing radiation over time using white light and fluorescence microscopy combined with optical coherence tomography (OCT) in vivo. In vivo power Doppler ultrasound and photoacoustics were used to directly visualize the cord and vascular structures and to measure hemoglobin oxygen saturation through the complete spinal cord, respectively. The model was also used for intravital imaging of spinal micrometastases resulting from primary brain tumor using fluorescence and bioluminescence imaging. Our SCWC model overcomes previous in vivo imaging challenges, and our data provide evidence of the broader utility of hybridized optical-acoustic imaging methods for obtaining multiparametric and rich imaging data sets, including over extended periods, for preclinical in vivo spinal cord research.
- 25 September 2012
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 57 (20) , 6601-6614
Displaying 3D radiation dose on endoscopic video for therapeutic assessment and surgical guidance
We have developed a method to register and display 3D parametric data, in particular radiation dose, on two-dimensional endoscopic images. This registration of radiation dose to endoscopic or optical imaging may be valuable in assessment of normal tissue response to radiation, and visualization of radiated tissues in patients receiving post-radiation surgery. Electromagnetic sensors embedded in a flexible endoscope were used to track the position and orientation of the endoscope allowing registration of 2D endoscopic images to CT volumetric images and radiation doses planned with respect to these images. A surface was rendered from the CT image based on the air/tissue threshold, creating a virtual endoscopic view analogous to the real endoscopic view. Radiation dose at the surface or at known depth below the surface was assigned to each segment of the virtual surface. Dose could be displayed as either a colorwash on this surface or surface isodose lines. By assigning transparency levels to each surface segment based on dose or isoline location, the virtual dose display was overlaid onto the real endoscope image. Spatial accuracy of the dose display was tested using a cylindrical phantom with a treatment plan created for the phantom that matched dose levels with grid lines on the phantom surface. The accuracy of the dose display in these phantoms was 0.8-0.99 mm. To demonstrate clinical feasibility of this approach, the dose display was also tested on clinical data of a patient with laryngeal cancer treated with radiation therapy, with estimated display accuracy of ∼2-3 mm. The utility of the dose display for registration of radiation dose information to the surgical field was further demonstrated in a mock sarcoma case using a leg phantom. With direct overlay of radiation dose on endoscopic imaging, tissue toxicities and tumor response in endoluminal organs can be directly correlated with the actual tissue dose, offering a more nuanced assessment of normal tissue toxicities following radiation therapy and accurate registration of radiation dose to the surgical field.
- 25 September 2012
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 57 (20) , 6601-6614
Displaying 3D radiation dose on endoscopic video for therapeutic assessment and surgical guidance
We have developed a method to register and display 3D parametric data, in particular radiation dose, on two-dimensional endoscopic images. This registration of radiation dose to endoscopic or optical imaging may be valuable in assessment of normal tissue response to radiation, and visualization of radiated tissues in patients receiving post-radiation surgery. Electromagnetic sensors embedded in a flexible endoscope were used to track the position and orientation of the endoscope allowing registration of 2D endoscopic images to CT volumetric images and radiation doses planned with respect to these images. A surface was rendered from the CT image based on the air/tissue threshold, creating a virtual endoscopic view analogous to the real endoscopic view. Radiation dose at the surface or at known depth below the surface was assigned to each segment of the virtual surface. Dose could be displayed as either a colorwash on this surface or surface isodose lines. By assigning transparency levels to each surface segment based on dose or isoline location, the virtual dose display was overlaid onto the real endoscope image. Spatial accuracy of the dose display was tested using a cylindrical phantom with a treatment plan created for the phantom that matched dose levels with grid lines on the phantom surface. The accuracy of the dose display in these phantoms was 0.8-0.99 mm. To demonstrate clinical feasibility of this approach, the dose display was also tested on clinical data of a patient with laryngeal cancer treated with radiation therapy, with estimated display accuracy of ∼2-3 mm. The utility of the dose display for registration of radiation dose information to the surgical field was further demonstrated in a mock sarcoma case using a leg phantom. With direct overlay of radiation dose on endoscopic imaging, tissue toxicities and tumor response in endoluminal organs can be directly correlated with the actual tissue dose, offering a more nuanced assessment of normal tissue toxicities following radiation therapy and accurate registration of radiation dose to the surgical field.
- Open Access
- 22 August 2012
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 7 (8) , e42133
In Vivo Optical Imaging of Tumor and Microvascular Response to Ionizing Radiation
Radiotherapy is a widely used cancer treatment. However, understanding how ionizing radiation affects tumor cells and their vasculature, particularly at cellular, subcellular, genetic, and protein levels, has been limited by an inability to visualize the response of these interdependent components within solid tumors over time and in vivo. Here we describe a new preclinical experimental platform combining intravital multimodal optical microscopy for cellular-level longitudinal imaging, a small animal x-ray microirradiator for reproducible spatially-localized millimeter-scale irradiations, and laser-capture microdissection of ex vivo tissues for transcriptomic profiling. Using this platform, we have developed new methods that exploit the power of optically-enabled microscopic imaging techniques to reveal the important role of the tumor microvasculature in radiation response of tumors. Furthermore, we demonstrate the potential of this preclinical platform to study quantitatively - with cellular and sub-cellular details - the spatio-temporal dynamics of the biological response of solid tumors to ionizing radiation in vivo.
- 22 August 2012
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 7 (8) , e42133
Open AccessIn Vivo Optical Imaging of Tumor and Microvascular Response to Ionizing Radiation
Radiotherapy is a widely used cancer treatment. However, understanding how ionizing radiation affects tumor cells and their vasculature, particularly at cellular, subcellular, genetic, and protein levels, has been limited by an inability to visualize the response of these interdependent components within solid tumors over time and in vivo. Here we describe a new preclinical experimental platform combining intravital multimodal optical microscopy for cellular-level longitudinal imaging, a small animal x-ray microirradiator for reproducible spatially-localized millimeter-scale irradiations, and laser-capture microdissection of ex vivo tissues for transcriptomic profiling. Using this platform, we have developed new methods that exploit the power of optically-enabled microscopic imaging techniques to reveal the important role of the tumor microvasculature in radiation response of tumors. Furthermore, we demonstrate the potential of this preclinical platform to study quantitatively - with cellular and sub-cellular details - the spatio-temporal dynamics of the biological response of solid tumors to ionizing radiation in vivo.