CBCharlotte J. Beurskens

Charlotte J. Beurskens

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Charlotte J. Beurskens has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The Potential of Heliox as a Therapy for Acute Respiratory Distress Syndrome in Adults and Children: A Descriptive Review

    by Charlotte J.P. Beurskens, Roelie M. Wösten-Van Asperen, Benedikt Preckel, Nicole P. Juffermans

    Background: In neonatal respiratory distress syndrome (RDS) and acute RDS (ARDS) mechanical ventilation is often necessary to manage hypoxia, whilst protecting the lungs through lower volume ventilation and permissive hypercapnia. Mechanical ventilation can, however, induce or aggravate the lung injury caused by the respiratory distress. Helium, in a gas mixture with oxygen (heliox), has a low density and can reduce the flow in narrow airways and allow for lower driving pressures. Objectives: The aim of this study was to review preclinical and clinical studies of the use of heliox ventilation in acute lung injury associated with respiratory failure. Methods: A systematic search was executed in the PubMed and EMBASE databases, with search terms referring to ARDS or an acute lung injury condition associated with respiratory failure and the corresponding intervention. Results: A total of 576 papers were retrieved. After the majority had been excluded 20 papers remained, of which 6 articles described animal models (3 paediatric; 3 adult animal models) and 14 were clinical studies, of which 12 described paediatric patient populations and 2 adult patient populations. In both paediatric and adult animal models, heliox improved gas exchange while allowing for less invasive ventilation in a wide variety of models using different ventilation modes. Clinical studies show a reduction in the work of breathing during heliox ventilation, with a concomitant increase in pH and decrease in PaCO2 levels compared to oxygen ventilation. Conclusions: Although evidence so far is limited, there may be a rationale for heliox ventilation in ARDS as an intervention to improve ventilation and reduce the work of breathing.


  • Open Access

    Cardiac arrest patients have an impaired immune response, which is not influenced by induced hypothermia

    by Charlotte J Beurskens, Janneke Horn, Anita M Tuip de Boer, Marcus J Schultz, Ester Mm van Leeuwen, Margreeth B Vroom, Nicole P Juffermans

    Introduction: Induced hypothermia is increasingly applied as a therapeutic intervention in ICUs. One of the underlying mechanisms of the beneficial effects of hypothermia is proposed to be reduction of the inflammatory response. However, a fear of reducing the inflammatory response is an increased infection risk. Therefore, we studied the effect of induced hypothermia on immune response after cardiac arrest. Methods: A prospective observational cohort study in a mixed surgical-medical ICU. Patients admitted at the ICU after surviving cardiac arrest were included and during 24 hours body temperature was strictly regulated at 33°C or 36°C. Blood was drawn at three time points: after reaching target temperature, at the end of the target temperature protocol and after rewarming to 37°C. Plasma cytokine levels and response of blood leucocytes to stimulation with toll-like receptor (TLR) ligands lipopolysaccharide (LPS) from Gram-negative bacteria and lipoteicoic acid (LTA) from Gram-positive bacteria were measured. Also, monocyte HLA-DR expression was determined. Results: In total, 20 patients were enrolled in the study. Compared to healthy controls, cardiac arrest patients kept at 36°C (n = 9) had increased plasma cytokines levels, which was not apparent in patients kept at 33°C (n = 11). Immune response to TLR ligands in patients after cardiac arrest was generally reduced and associated with lower HLA-DR expression. Patients kept at 33°C had preserved ability of immune cells to respond to LPS and LTA compared to patients kept at 36°C. These differences disappeared over time. HLA-DR expression did not differ between 33°C and 36°C. Conclusions: Patients after cardiac arrest have a modest systemic inflammatory response compared to healthy controls, associated with lower HLA-DR expression and attenuated immune response to Gram-negative and Gram-positive antigens, the latter indicative of an impaired immune response to bacteria. Patients with a body temperature of 33°C did not differ from patients with a body temperature of 36°C, suggesting induced hypothermia does not affect immune response in patients with cardiac arrest. Trial registration: ClinicalTrials.gov NCT01020916, registered 25 November 2009


  • Open Access

    Mechanical ventilation with heliox in an animal model of acute respiratory distress syndrome

    by Charlotte J Beurskens, Hamid Aslami, Friso M de Beer, Joris Jth Roelofs, Margreeth B Vroom, Nicole P Juffermans

    Heliox has a lower density and higher diffusion capacity compared to oxygen-in-air. We hypothesized that heliox ventilation allows for a reduction in minute volume ventilation and inspiratory pressures needed for adequate gas exchange in an animal model of an acute lung injury. After intratracheal instillation of lipopolysaccharide (10 mg/kg), adult rats were randomized to ventilation with either a gas mixture of helium/oxygen (50:50%) or oxygen/air (50:50%). They were mechanically ventilated according to the ARDSnet recommendations with tidal volumes of 6 ml/kg and monitored with a pneumotachometer. Bronchoalveolar lavage fluid was analyzed for markers of lung injury, and embedded lung sections were histologically scored for lung injury. Heliox limited the increase in driving pressures needed to achieve preset tidal volumes, with a concomitant decrease in loss of compliance. Heliox did neither allow for reduced minute volume ventilation in this model nor improve gas exchange. Also, heliox did not reduce lung injury. Heliox modestly improved respiratory mechanics but did not improve lung injury in this rat model of acute respiratory distress syndrome.


  • Open Access

    Heliox Improves Carbon Dioxide Removal during Lung Protective Mechanical Ventilation

    by Charlotte J. Beurskens, Daniel Brevoord, Wim K. Lagrand, Walter M. van Den Bergh, Margreeth B. Vroom, Benedikt Preckel, Janneke Horn, Nicole P. Juffermans

    Introduction. Helium is a noble gas with low density and increased carbon dioxide (CO2) diffusion capacity. This allows lower driving pressures in mechanical ventilation and increased CO2diffusion. We hypothesized that heliox facilitates ventilation in patients during lung-protective mechanical ventilation using low tidal volumes.Methods. This is an observational cohort substudy of a single arm intervention study. Twenty-four ICU patients were included, who were admitted after a cardiac arrest and mechanically ventilated for 3 hours with heliox (50% helium; 50% oxygen). A fixed protective ventilation protocol (6 mL/kg) was used, with prospective observation for changes in lung mechanics and gas exchange. Statistics was by Bonferroni post-hoc correction with statistical significance set atP<0.017.Results. During heliox ventilation, respiratory rate decreased (25±4versus23±5breaths min−1,P=0.010). Minute volume ventilation showed a trend to decrease compared to baseline (11.1±1.9versus9.9±2.1 L min−1,P=0.026), while reducing PaCO2levels (5.0±0.6versus4.5±0.6 kPa,P=0.011) and peak pressures (21.1±3.3versus19.8±3.2 cm H2O,P=0.024).Conclusions. Heliox improved CO2elimination while allowing reduced minute volume ventilation in adult patients during protective mechanical ventilation.


  • Open Access

    Heliox Allows for Lower Minute Volume Ventilation in an Animal Model of Ventilator-Induced Lung Injury

    by Charlotte J. Beurskens, Hamid Aslami, Friso M. de Beer, Margreeth B. Vroom, Benedikt Preckel, Janneke Horn, Nicole P. Juffermans

    Helium is a noble gas with a low density, allowing for lower driving pressures and increased carbon dioxide (CO2) diffusion. Since application of protective ventilation can be limited by the development of hypoxemia or acidosis, we hypothesized that therefore heliox facilitates ventilation in an animal model of ventilator–induced lung injury. Sprague-Dawley rats (N=8 per group) were mechanically ventilated with heliox (50% oxygen; 50% helium). Controls received a standard gas mixture (50% oxygen; 50% air). VILI was induced by application of tidal volumes of 15 mL kg-1; lung protective ventilated animals were ventilated with 6 mL kg-1. Respiratory parameters were monitored with a pneumotach system. Respiratory rate was adjusted to maintain arterial pCO2 within 4.5-5.5 kPa, according to hourly drawn arterial blood gases. After 4 hours, bronchoalveolar lavage fluid (BALF) was obtained. Data are mean (SD). VILI resulted in an increase in BALF protein compared to low tidal ventilation (629 (324) vs. 290 (181) μg mL-1; p-1; p-1, P2 levels and tidal volumes remained unchanged, according to protocol. There was no effect of heliox on inspiratory pressure, while compliance was reduced. In this mild lung injury model, heliox did not exert anti-inflammatory effects. Heliox allowed for a reduction in respiratory rate and respiratory minute volume during VILI, while maintaining normal acid-base balance. Use of heliox may be a useful approach when protective tidal volume ventilation is limited by the development of severe acidosis.