DWDavid H. Wilson

David H. Wilson

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


David H. Wilson has a total of 64 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Comparison of a multi‐analyte algorithmic immunoassay blood test with immunoprecipitation mass spectrometry for the detection of amyloid pathology

    by David Wilson, Karen Copeland, Lindsey Mette, Meenakshi Khare, Matt Polak, Jorge Marques Signes, Tim Skelton

    INTRODUCTION: Alzheimer's blood‐based biomarker (BBM) tests using single biomarkers or ratios are well characterized, but head‐to‐head comparisons of multi‐analyte algorithmic tests on shared cohorts are lacking. We compared a five‐biomarker algorithmic immunoassay (LucentAD Complete) with an algorithmic immunoprecipitation mass‐spectrometry (IP‐MS) benchmark on a shared plasma cohort. METHODS: Symptomatic individuals ( n = 192) with longitudinal samples from Alzheimer's Disease Neuroimaging Initiative (ADNI) were analyzed versus amyloid positron emission tomography (PET). Cross‐sectional ( n = 115) and longitudinal ( n = 179; 12‐year span) cohorts representing disease progression were used. RESULTS: The immunoassay amyloid risk score demonstrated a 0.94 area under the curve (AUC) and 92%–93% accuracy, achieving performance parity with IP‐MS metrics on shared samples. The two‐cutoff design yielded an intermediate zone of 10.4%–12.8%. DISCUSSION: These results establish diagnostic parity between algorithmic immunoassay and algorithmic IP‐MS assay. In addition, providing individual biomarker results alongside a validated risk score offers a more granular foundation for comprehensive management than amyloid status alone, supporting premium reimbursement for multi‐analyte algorithmic BBMs in clinical practice.

  • Open Access

    Clinical performance of scalable automated p‐tau 217 multi‐analyte algorithmic blood test with reduced intermediate zone using multiplexed digital immunoassay

    by David H. Wilson, Karen Copeland, Mike Miller, Ann‐Jeanette Vasko, Lyndal Hesterberg, Meenakshi Khare, Michele Wolfe, Patrick Sheehy, Inge Verberk, Charlotte Teunissen

    INTRODUCTION: To address an urgent need for a scalable, accurate blood test for brain amyloid pathology that provides a conclusive result for the greatest number of patients, we developed a multi‐analyte algorithmic test combining phosphorylated tau (p‐tau) 217 with four other biomarkers. METHODS: Multiplexed digital immunoassays measured p‐tau 217, amyloid beta 42/40, glial fibrillary acidic protein, and neurofilament light chain in 730 symptomatic individuals (training set) to establish an algorithm with cutoffs, and 1082 symptomatic individuals (validation set) from three independent cohorts to identify brain amyloid pathology. RESULTS: The algorithmic in validation gave an area under the curve = 0.92, yielding 90% agreement with amyloid positron emission tomography and cerebrospinal fluid. Positive predictive value was 92% at 55% prevalence. The multi‐marker algorithm reduced the intermediate zone ≈ 3‐fold from 34.4% to 11.9% versus p‐tau 217 alone. Diagnostic performance was similar across subgroups. DISCUSSION: The LucentAD Complete multi‐analyte blood test demonstrated high clinical validity for brain amyloid pathology detection while substantially reducing inconclusive intermediate results. Highlights: We developed a multi‐analyte blood test for assessing brain amyloid status that significantly minimizes the ambiguous “intermediate zone,” a key limitation of plasma phosphorylated tau (p‐tau) 217 alone. Our test combines plasma levels of p‐tau 217, amyloid beta 42/40 ratio, glial fibrillary acidic protein, and neurofilament light chain for a more comprehensive evaluation of amyloid status. We rigorously validated the test's clinical performance in > 1000 samples from symptomatic individuals across three independent cohorts, using cerebrospinal fluid biomarkers and amyloid positron emission tomography as comparators.


  • Open Access

    Analytical and clinical validation of a high accuracy fully automated digital immunoassay for plasma phospho-Tau 217 for clinical use in detecting amyloid pathology

    by David Wilson, Meenakshi Khare, Gallen Triana-Baltzer, Michele Wolfe, Patrick Sheehy, Karen Copeland, Lyndal Hesterberg, Ann-Jeanette Vasko, Wiesje M. van der Flier, Inge M. W. Verberk, et al.

    Background: With the emergence of disease-modifying therapies for Alzheimer’s disease (AD), there is an urgent need for scalable, accurate, and well-validated blood test alternatives to positron emission topography (PET) and lumbar punctures for identifying amyloid pathology to facilitate identification of candidates for therapy. Plasma p-Tau 217 has emerged as a plasma-based biomarker with sufficient sensitivity and specificity to both rule out and rule in amyloid pathology with high confidence, potentially serving as a readily scalable non-invasive test to aid AD diagnosis. In this report, we describe robust analytical and clinical validation of a lab developed test for plasma p-Tau 217 suitable for clinical diagnostic use.Methods: A high sensitivity digital immunoassay using single molecule array (Simoa) technology was developed for plasma p-Tau 217 utilizing a 2-cutoff approach. The assay was analytically validated with industry standard protocols and clinically validated across 873 symptomatic individuals from two independent clinical cohorts using PET or cerebrospinal fluid (CSF) biomarkers as comparators.Results: The assay exhibited acceptable analytical characteristics with an analytical sensitivity enabling measurement of plasma p-Tau 217 in all clinical samples. Excluding results between the two cutoffs, clinical sensitivity, specificity, and agreement with comparator methods (accuracy) were >90%, with 30.9% of the samples falling in the intermediate zone between the two cutoffs.Discussion: The performance characteristics of the Simoa p-Tau 217 assay align with current accuracy recommendations for blood-based biomarker test performance for diagnostic use, making the test suitable for clinical use under the Clinical Laboratory Improvement Act (CLIA) as a diagnostic plasma test to aid in Alzheimer’s diagnosis.


  • Open Access

    Multi‐Marker Approach to Reducing the Intermediate Range of a High Accuracy 2‐Cutoff Plasma p‐Tau 217 Test for Amyloid Detection

    by David H Wilson, Meenakshi Khare, Michele Wolfe, Patrick Sheehy, Karen Copeland, Lyndal Hesterberg, Ann‐Jeanette Vasko, Wiesje M. van der Flier, Argonde C. van Harten, Inge M.W. Verberk, et al.

    Background: p‐Tau 217 is considered the most accurate single plasma biomarker for detecting amyloid pathology. Recent draft Alzheimer’s Association criteria for diagnosing Alzheimer’s recommends that p‐Tau 217 tests be designed with two cut‐offs in recognition of signal overlap between diseased and non‐diseased subjects. Two cutoffs maximizes the accuracy of the test, but leaves a diagnostic intermediate zone with uncertainty of amyloid status. It is desirable to minimize the indeterminant zone to reduce the number of patients receiving uncertain results. We investigated whether the inclusion of plasma amyloid b42/40 ratio, NfL, and GFAP into a multi‐marker logistic regression model including p‐Tau 217 would enable amyloid classification of uncertain results from p‐Tau 217 alone.Method: We optimized diagnostic thresholds for the Simoa LucentAD p‐Tau 217 plasma test to achieve ≥90% accuracy for MCI and AD patients across 2 independent cohorts (Bio‐Hermes, n = 242, Amsterdam Dementia Cohort, n = 737) representing divergent clinical settings, comparator methods, and geographic/ethnic/racial/mean age samplings. Across these diverse cohorts, the intermediate zone was 32.9%. Next we tested all samples for amyloid ratio, NfL, and GFAP using the Simoa N4PE kit. Multivariate logistic regression modeling was performed on all biomarker results to arrive at a probability scale. Samples with uncertain p‐Tau 217 results were re‐classified based on their probabilities being outside 90% lower and upper boundaries of the multi‐marker intermediate zone.Result: Tables 1 and 2 exhibit preliminary amyloid classification results for p‐Tau 217 alone and the multi‐marker model respectively. “Amyloid Status” was determined by amyloid PET (Bio‐Hermes) or CSF biomarkers (Amsterdam). The multi‐marker model enabled amyloid classifications for 189 previously uncertain results. 137 uncertain results were re‐classified as positive (accuracy 88%), and 52 uncertain results were re‐classified as negative (accuracy 87%), reducing the intermediate zone 2.4‐fold from 32.9% to 13.7%.Conclusion: Previous studies have found no benefit to combining additional AD‐relevant biomarkers with p‐Tau 217 to enhance accuracy. We show for the first time that additional biomarkers reduces the intermediate zone of a 2‐cutoff p‐Tau 217 test while preserving high accuracy. This finding can help provide amyloid status certainty for a greater number of symptomatic patients undergoing evaluation for Alzheimer’s.


  • Open Access

    Analytical and Clinical Validation of a High Accuracy Fully Automated Digital Immunoassay for Plasma Phospho-Tau 217 for Clinical Use in Detecting Amyloid Pathology

    by David H. Wilson, Meenakshi Khare, Gallen Triana-Baltzer, Michele Wolfe, Patrick Sheehy, Karen Copeland, Lyndal Hesterberg, Ann-Jeanette Vasko, Wiesje M. van der Flier, Inge M.W. Verberk, et al.

    Objectives: Phospho-tau 217 (p-Tau 217) in plasma has emerged as a promising biomarker for detecting amyloid pathology in plasma as an aid in diagnosis of Alzheimer’s disease. Because of its low abundance in plasma, reliable quantitation in blood is challenging. Digital single molecule array (Simoa) technology provides higher analytical sensitivity than possible with conventional analog immunoassays, enabling precise measurement of plasma p-Tau 217. We report the analytical and clinical validation of a Simoa digital immunoassay for p-Tau 217 across highly diverse clinical cohorts that meets consensus criteria for confirmatory test performance to aid the diagnosis of Alzheimer’s disease in people with cognitive impairment. Methods: A Simoa p-Tau 217 assay utilizing a 2-cutoff approach was analytically validated using industry standard protocols, and diagnostic thresholds were clinically validated across 2 clinically diverse independent cohorts (total n = 873) using amyloid PET or CSF biomarkers as comparators. Results: The assay exhibited acceptable analytical characteristics, including analytical sensitivity enabling measurement of plasma p-Tau 217 in all clinical samples and a lower limit of quantitation of 0.006 pg/ml. For samples not in the intermediate zone between the 2 cutoffs, the assay gave a clinical sensitivity of 90.3%, a specificity of 91.3%, and overall accuracy of 90.7%. 30.9% of the samples fell into the intermediate zone between the lower and upper cutoffs (0.04 and 0.09 pg/mL respectively). With an amyloid prevalence of 50%, typical for mild cognitive impairment, the positive and negative predictive values were 91.4% and 90.4% respectively. Conclusions: The analytical characteristics are suitable for implementation of the Simoa p-Tau 217 assay as a lab developed test under the Clinical Laboratory Improvement Act (CLIA), and the clinical performance characteristics meet consensus criteria for a confirmatory plasma test to aid in Alzheimer’s diagnosis. RESEARCH IN CONTEXT: Evidence before this study: Following rapid advances in plasma testing for AD-related biomarkers, the field has coalesced around p-Tau 217 as the most accurate single blood-based biomarker for detecting the presence of amyloid pathology. There have been a number of recent reports and conference presentations on different tests for plasma p-Tau 217 including large head-to-head comparisons. To date, however, none of these reports examine the analytical and clinical performance characteristics of the test--or the methodologies by which these characteristics were determined--in sufficient detail for a critical evaluation of the fitness of the test for its intended clinical use. Indeed, it has been the lack of robust analytical and clinical validation reporting that has led some to question if some of these tests are ready for prime time. Added value of this study: Our work is the first to describe in detail the analytical and clinical performance characteristics of a high-accuracy laboratory developed test for plasma p-Tau 217 validated for clinical use. While the test is not currently FDA cleared, the validation studies were conducted with study protocols recommended by the FDA that generally exceed the standards required of LDTs developed and offered for clinical use under the Clinical Laboratory Improvement Act (CLIA). This report helps advance the field by describing the level of validation that is compatible with the FDA’s Final Rule (May 2024, FDA-2023-N-2177) in which LDTs were included as regulated in vitro diagnostic devices. Detailed validation reports like this can facilitate critical evaluation of whether a currently available LDT is fit for use as demonstrated by its validation robustness. More rigorous validation of these tests represents an important next step on the path toward widespread adoption and use of blood-based biomarkers for AD.


  • Examining Inflammatory Cytokines in Serum and Plasma

    by Dandan Shan, David Wilson

    The only peer-reviewed journal focused on the rapidly moving field of 3D printing and related technologies, providing comprehensive coverage of academic research and industrial and commercial developments that have applications in medicine, education, food, and architecture.


  • Top Cited Papers
    Open Access

    The Simoa HD-1 Analyzer: A Novel Fully Automated Digital Immunoassay Analyzer with Single-Molecule Sensitivity and Multiplexing

    by David H. Wilson, David M. Rissin, Cheuk W. Kan, David R. Fournier, Tomasz Piech, Todd G. Campbell, Raymond E. Meyer, Matthew W. Fishburn, Carlos Cabrera, Purvish P. Patel, et al.


  • Rapid, Fully Automated Digital Immunoassay for p24 Protein with the Sensitivity of Nucleic Acid Amplification for Detecting Acute HIV Infection

    by Carlos Cabrera, Lei Chang, Mars Stone, Michael Busch, David H. Wilson

    BACKGROUND Nucleic acid testing (NAT) has become the standard for high sensitivity in detecting low levels of virus. However, adoption of NAT can be cost prohibitive in low-resource settings where access to extreme sensitivity could be clinically advantageous for early detection of infection. We report development and preliminary validation of a simple, low-cost, fully automated digital p24 antigen immunoassay with the sensitivity of quantitative NAT viral load (NAT-VL) methods for detection of acute HIV infection. METHODS We developed an investigational 69-min immunoassay for p24 capsid protein for use on a novel digital analyzer on the basis of single-molecule-array technology. We evaluated the assay for sensitivity by dilution of standardized preparations of p24, cultured HIV, and preseroconversion samples. We characterized analytical performance and concordance with 2 NAT-VL methods and 2 contemporary p24 Ag/Ab combination immunoassays with dilutions of viral isolates and samples from the earliest stages of HIV infection. RESULTS Analytical sensitivity was 0.0025 ng/L p24, equivalent to 60 HIV RNA copies/mL. The limit of quantification was 0.0076 ng/L, and imprecision across 10 runs was 4000-fold greater sensitivity than contemporary immunoassays for p24 and sensitivity equivalent to that of NAT methods for early detection of HIV. The data indicate that NAT-level sensitivity for acute HIV infection is possible with a simple, low-cost digital immunoassay.


  • Open Access

    Fully Automated Ultrasensitive Digital Immunoassay for Cardiac Troponin I Based on Single Molecule Array Technology

    by Petr Jarolim, Purvish P Patel, Michael J Conrad, Lei Chang, Vojtech Melenovsky, David H Wilson

    BACKGROUND: The association between increases in cardiac troponin and adverse cardiac outcomes is well established. There is a growing interest in exploring routine cardiac troponin monitoring as a potential early indicator of adverse heart health trends. Prognostic use of cardiac troponin measurements requires an assay with very high sensitivity and outstanding analytical performance. We report development and preliminary validation of an investigational assay meeting these requirements and demonstrate its applicability to cohorts of healthy individuals and patients with heart failure. METHODS: On the basis of single molecule array technology, we developed a 45-min immunoassay for cardiac troponin I (cTnI) for use on a novel, fully automated digital analyzer. We characterized its analytical performance and measured cTnI in healthy individuals and heart failure patients in a preliminary study of assay analytical efficacy. RESULTS: The assay exhibited a limit of detection of 0.01 ng/L, a limit of quantification of 0.08 ng/L, and a total CV of 10% at 2.0 ng/L. cTnI concentrations were well above the assay limit of detection for all samples tested, including samples from healthy individuals. cTnI was significantly higher in heart failure patients, and exhibited increasing median and interquartile concentrations with increasing New York Heart Association classification of heart failure severity. CONCLUSIONS: The robust 2-log increase in sensitivity relative to contemporary high-sensitivity cardiac troponin immunoassays, combined with full automation, make this assay suitable for exploring cTnI concentrations in cohorts of healthy individuals and for the potential prognostic application of serial cardiac troponin measurements in both apparently healthy and diseased individuals.


  • Open Access

    Plasma tau levels in Alzheimer's disease

    by Henrik Zetterberg, David Wilson, Ulf Andreasson, Lennart Minthon, Kaj Blennow, Jeffrey Randall, Oskar Hansson