AMAgnella Izzo Matic

Agnella Izzo Matic

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Agnella Izzo Matic has a total of 14 co-authors. Here are the top co-authors by number of shared publications:

  • Joseph T. Walsh

    Northwestern University, Department of Biomedical Engineering, 2145 Sheridan Road, Tech E310, Evanston, Illinois 60208

    3 shared publications
  • Claus-Peter Richter

    Department of Otolaryngology, Northwestern University, Chicago, Illinois 60611; †Department of Biomedical Engineering, Northwestern University, Evanston, Illinois 60208; ‡Aculight Corp., Bothell, Washington 98021; and §Auditory Physiology Laboratory (The Hugh Knowles Center), Department of Communication Sciences and Disorders, Northwestern University, Evanston, Illinois 60208

    2 shared publications
  • Claus-Peter Richter

    Department of Otolaryngology-Head and Neck Surgery, Feinberg School of Medicine, Northwestern University, Chicago, IL 60611, USA

    2 shared publications
  • E. Duco Jansen

    Vanderbilt University, Department of Biomedical Engineering, Nashville, Tennessee, United States

    2 shared publications
  • Heather Ralph

    Department of Otolaryngology, Northwestern University, Chicago, Illinois 60611; †Department of Biomedical Engineering, Northwestern University, Evanston, Illinois 60208; ‡Aculight Corp., Bothell, Washington 98021; and §Auditory Physiology Laboratory (The Hugh Knowles Center), Department of Communication Sciences and Disorders, Northwestern University, Evanston, Illinois 60208

    2 shared publications
  • Jim Webb

    Department of Otolaryngology, Northwestern University, Chicago, Illinois 60611; †Department of Biomedical Engineering, Northwestern University, Evanston, Illinois 60208; ‡Aculight Corp., Bothell, Washington 98021; and §Auditory Physiology Laboratory (The Hugh Knowles Center), Department of Communication Sciences and Disorders, Northwestern University, Evanston, Illinois 60208

    2 shared publications

Latest Publications

  • Spatial extent of cochlear infrared neural stimulation determined by tone-on-light masking

    by Agnella Izzo Matic, Joseph T. Walsh, Claus-Peter Richter

    Artificial neural stimulation is widely used in clinic, rehabilitation, and research. One of the limitations of electrical stimulation is the current spread in tissue. Recently, pulsed mid-infrared laser stimulation of nerves has been investigated as an alternative stimulation method. The likely benefits of infrared neural stimulation (INS) include spatial selectivity of stimulation, noncontact mode of operation, and the lack of stimulation artifact in simultaneous electrical recordings. The hypothesis for this study is that INS of the cochlear spiral ganglion at low pulse energy is as spatially selective as low-level tonal stimulation of the cochlea. Spatial selectivity was measured using a masking method. An optical pulse with fixed optical parameters was delivered through a 200-μm diameter optical fiber. An acoustic tone, variable in frequency and level, was presented simultaneously with the optical pulse. Tone-on-light masking in gerbils revealed tuning curves with best frequencies between 5.3 and 11.4 kHz. The width of the tone-on-light tuning curves was similar to the width of tone-on-tone tuning curves. The results indicate that the spatial area of INS in the gerbil cochlea is similar to the cochlear area excited by a low level acoustic tone, showing promising results for future use of INS in implantable cochlear prostheses.


  • Laser Stimulation of Auditory Neurons: Effect of Shorter Pulse Duration and Penetration Depth

    by Agnella D. Izzo, Joseph T. Walsh, Heather Ralph, Jim Webb, Mark Bendett, Jonathon Wells, Claus-Peter Richter


  • Optical Parameter Variability in Laser Nerve Stimulation: A Study of Pulse Duration, Repetition Rate, and Wavelength

    by Agnella D. Izzo, Joseph T. Walsh, E. Duco Jansen, Mark Bendett, Jim Webb, Heather Ralph, Claus-Peter Richter

    Pulsed lasers can evoke neural activity from motor as well as sensory neurons in vivo. Lasers allow more selective spatial resolution of stimulation than the conventional electrical stimulation. To date, few studies have examined pulsed, mid-infrared laser stimulation of nerves and very little of the available optical parameter space has been studied. In this study, a pulsed diode laser, with wavelength between 1.844-1.873 mum, was used to elicit compound action potentials (CAPs) from the auditory system of the gerbil. We found that pulse durations as short as 35 mus elicit a CAP from the cochlea. In addition, repetition rates up to 13Hz can continually stimulate cochlear spiral ganglion cells for extended periods of time. Varying the wavelength and, therefore, the optical penetration depth, allowed different populations of neurons to be stimulated. The technology of optical stimulation could significantly improve cochlear implants, which are hampered by a lack of spatial selectivity


  • Laser stimulation of auditory neurons at high repetition rate

    by Agnella D. Izzo, Philip Littlefield, Jr. Joseph T. Walsh, Jim Webb, Heather Ralph, Mark Bendett, E. Duco Jansen, Claus-Peter Richter

    Pulsed, mid-infrared lasers can evoke neural activity from motor as well as sensory neurons in vivo. Lasers allow more selective spatial resolution of stimulation than the conventional electrical stimulation. To date, few studies have examined pulsed, mid-infrared neural stimulation and very little of the available optical parameter space has been studied. We found that pulse durations as short as 20 ?s elicit a compound action potential from the gerbil cochlea. Moreover, stimulation thresholds are not a function of absolute energy or absolute power deposited. Compound action potential peak-to-peak amplitude remained constant over extended periods of stimulation. Stimulation occurred up six hours continuously and up to 50 Hz in repetition rate. Single fiber experiments were made using repetition rates of up to 1 kHz. Action potentials occurred 2.5-4 ms after the laser pulse. Maximum rates of discharge were up to 250 action potentials per second. With increasing stimulation rate (300 Hz), the action potentials did not respond strictly after the light pulse. The results from these experiments are important for designing the next generation of neuroprostheses, specifically cochlear implants.