Jade S. Hiramoto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jade S. Hiramoto has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Linda M. Reilly
Department of Surgery, Division of Vascular Surgery, University of California, San Francisco, San Francisco, CA
6 shared publicationsDarren B. Schneider
Department of Surgery, Division of Vascular Surgery, University of California, San Francisco, San Francisco, CA
4 shared publicationsTimothy A.M. Chuter
Department of Surgery, Division of Vascular Surgery, University of California, San Francisco, San Francisco, CA
4 shared publications- Darren B. Schneider
Department of Surgery, Division of Vascular Surgery, University of California at San Francisco, California, USA
2 shared publications Joseph H. Rapp
Department of Surgery, Division of Vascular Surgery, University of California, San Francisco, San Francisco, CA
2 shared publicationsL.M. Reilly
Division of Vascular Surgery, Department of Surgery, University of California San Francisco, San Francisco, Californie, USA
2 shared publications
Latest Publications
- 1 April 2010
- Published by International Society of Endovascular Specialists in Journal of Endovascular Therapy
- Vol. 17 (2) , 222-223
Commentary: Multiple Chimney Grafts for Total Endovascular Revascularization of the Visceral Arteries in the Setting of Ruptured TAAA: Inventive but Let's Wait for the Smoke to Clear on This One
- 1 April 2010
- Published by International Society of Endovascular Specialists in Journal of Endovascular Therapy
- Vol. 17 (2) , 222-223
Commentary: Multiple Chimney Grafts for Total Endovascular Revascularization of the Visceral Arteries in the Setting of Ruptured TAAA: Inventive but Let's Wait for the Smoke to Clear on This One
- 1 April 2010
- Published by International Society of Endovascular Specialists in Journal of Endovascular Therapy
- Vol. 17 (2) , 266-267
Commentary: Surgeon-Modified Multi-Branched Stent-Grafts: The Options Abound
- 1 April 2010
- Published by International Society of Endovascular Specialists in Journal of Endovascular Therapy
- Vol. 17 (2) , 266-267
Commentary: Surgeon-Modified Multi-Branched Stent-Grafts: The Options Abound
- 1 April 2009
- Published by SAGE Publications in Vascular
- Vol. 17 (2) , 93-95
The Upside-Down Zenith Stent Graft Limb
None of the commercially available stent grafts are supplied in a tapered configuration suitable for the endovascular repair of common iliac artery aneurysms. We describe a simple technique for reversing the proximal and distal orientation of a standard flared bell-bottom stent graft limb from the Zenith system of abdominal aortic aneurym repair. When reloaded in this fashion, the stent graft is deployed just like any other Zenith (Cook, Inc., Bloomington, IN) stent graft limb. However, we caution that this departure from standard use introduces new sources of potential device failure, requires several additional precautions, and should not be attempted by those unfamiliar with the routine use of the unmodified device.
- 1 April 2009
- Published by SAGE Publications in Vascular
- Vol. 17 (2) , 93-95
The Upside-Down Zenith Stent Graft Limb
None of the commercially available stent grafts are supplied in a tapered configuration suitable for the endovascular repair of common iliac artery aneurysms. We describe a simple technique for reversing the proximal and distal orientation of a standard flared bell-bottom stent graft limb from the Zenith system of abdominal aortic aneurym repair. When reloaded in this fashion, the stent graft is deployed just like any other Zenith (Cook, Inc., Bloomington, IN) stent graft limb. However, we caution that this departure from standard use introduces new sources of potential device failure, requires several additional precautions, and should not be attempted by those unfamiliar with the routine use of the unmodified device.
- 31 December 2008
- Published by Elsevier in Annales de Chirurgie Vasculaire
- Vol. 22 (6) , 763-770
Technique de la double lumière pour préserver la perméabilité des troncs supra-aortiques au cours du traitement endovasculaire des lésions de l'aorte thoracique
- 31 December 2008
- Published by Elsevier in Annales de Chirurgie Vasculaire
- Vol. 22 (6) , 763-770
Technique de la double lumière pour préserver la perméabilité des troncs supra-aortiques au cours du traitement endovasculaire des lésions de l'aorte thoracique
- 1 December 2008
- Published by SAGE Publications in Vascular
- Vol. 16 (6) , 321-325
Effect of Systemic Blood Pressure on Aneurysm Size in the Presence of a Type II Endoleak
The objective of this study was to determine whether hypertension is a risk factor for aneurysm enlargement in patients with an untreated type II endoleak after endovascular abdominal aortic aneurysm repair (EVAR). Between January 2000 and December 2005, 296 patients underwent elective EVAR using a bifurcated Zenith stent graft. Forty-nine (17%) patients had a type II endoleak triaged to observation. Patient clinical data and data on endoleak status, aneurysm size, and endoleak intervention were collected prospectively. Aneurysm size remained the same or decreased in 39 of 49 (80%) patients. In the remaining 10 (20%) patients with aneurysm enlargement, 7 required intervention. There was no difference in initial aneurysm size, patient age, gender, or comorbidities between patients with enlarging aneurysms and those with stable or regressing aneurysms. However, patients with enlarging aneurysms had a mean systolic blood pressure (SBP) of 144 ± 14 mm Hg compared with 136 ± 13 mm Hg for patients with stable or regressing aneurysms (p = .08). Multivariate regression analysis demonstrated increased SBP to be an independent predictor of aneurysm enlargement (p = .05). Patients with systolic hypertension and an untreated type II endoleak are more likely to demonstrate aneurysm enlargement after EVAR. Aggressive blood pressure control may be an important adjunct in the management of patients with type II endoleak after EVAR.
- 1 December 2008
- Published by SAGE Publications in Vascular
- Vol. 16 (6) , 321-325
Effect of Systemic Blood Pressure on Aneurysm Size in the Presence of a Type II Endoleak
The objective of this study was to determine whether hypertension is a risk factor for aneurysm enlargement in patients with an untreated type II endoleak after endovascular abdominal aortic aneurysm repair (EVAR). Between January 2000 and December 2005, 296 patients underwent elective EVAR using a bifurcated Zenith stent graft. Forty-nine (17%) patients had a type II endoleak triaged to observation. Patient clinical data and data on endoleak status, aneurysm size, and endoleak intervention were collected prospectively. Aneurysm size remained the same or decreased in 39 of 49 (80%) patients. In the remaining 10 (20%) patients with aneurysm enlargement, 7 required intervention. There was no difference in initial aneurysm size, patient age, gender, or comorbidities between patients with enlarging aneurysms and those with stable or regressing aneurysms. However, patients with enlarging aneurysms had a mean systolic blood pressure (SBP) of 144 ± 14 mm Hg compared with 136 ± 13 mm Hg for patients with stable or regressing aneurysms (p = .08). Multivariate regression analysis demonstrated increased SBP to be an independent predictor of aneurysm enlargement (p = .05). Patients with systolic hypertension and an untreated type II endoleak are more likely to demonstrate aneurysm enlargement after EVAR. Aggressive blood pressure control may be an important adjunct in the management of patients with type II endoleak after EVAR.
- 1 November 2008
- Published by Elsevier in Anales de Cirugía Vascular
- Vol. 22 (6) , 761-768
Técnica en doble cañón para preservar las ramas del cayado aórtico durante la reparación endovascular de la aorta torácica
- 1 November 2008
- Published by Elsevier in Anales de Cirugía Vascular
- Vol. 22 (6) , 761-768
Técnica en doble cañón para preservar las ramas del cayado aórtico durante la reparación endovascular de la aorta torácica
- 1 June 2008
- Published by International Society of Endovascular Specialists in Journal of Endovascular Therapy
- Vol. 15 (3) , 356-362
Spinal Arterial Anatomy and Risk Factors for Lower Extremity Weakness Following Endovascular Thoracoabdominal Aortic Aneurysm Repair With Branched Stent-Grafts
Purpose: To evaluate spinal arterial anatomy and identify risk factors for lower extremity weakness (LEW) following endovascular thoracoabdominal aortic aneurysm (TAAA) repair. Methods: A retrospective review was conducted of 37 patients (27 men; mean age 74.8±7.1 years, range 58–86) undergoing endovascular TAAA repair with branched stent-grafts at a single academic institution from July 2005 to December 2007. Data were collected on preoperative comorbidities, duration of operation, blood loss, type of anesthesia, extent of aortic coverage, blood pressure, cerebrospinal fluid (CSF) pressure and drainage, and postoperative development of LEW. Pre- and postoperative contrast-enhanced computed tomographic angiograms (CTA) in a 26-patient subset were analyzed to evaluate the number of patent intercostal and lumbar arteries before and after repair. Results: All patients were neurologically intact at the end of the operation. Seven (19%) patients developed LEW postoperatively: 6 perioperatively and 1 after discharge. LEW was associated with postoperative hypotension, internal iliac artery (IIA) occlusion, and fewer patent segmental arteries on preoperative CTA. Lowest mean systolic blood pressure was Conclusion: Endovascular TAAA repair inevitably occludes direct inflow to lumbar and intercostal arteries. The distal segments of these arteries to the spine, however, are seen to remain patent through collaterals. Measures to preserve collateral pathways and increase perfusion pressure may help prevent or treat LEW.
- 1 June 2008
- Published by International Society of Endovascular Specialists in Journal of Endovascular Therapy
- Vol. 15 (3) , 356-362
Spinal Arterial Anatomy and Risk Factors for Lower Extremity Weakness Following Endovascular Thoracoabdominal Aortic Aneurysm Repair With Branched Stent-Grafts
Purpose: To evaluate spinal arterial anatomy and identify risk factors for lower extremity weakness (LEW) following endovascular thoracoabdominal aortic aneurysm (TAAA) repair. Methods: A retrospective review was conducted of 37 patients (27 men; mean age 74.8±7.1 years, range 58–86) undergoing endovascular TAAA repair with branched stent-grafts at a single academic institution from July 2005 to December 2007. Data were collected on preoperative comorbidities, duration of operation, blood loss, type of anesthesia, extent of aortic coverage, blood pressure, cerebrospinal fluid (CSF) pressure and drainage, and postoperative development of LEW. Pre- and postoperative contrast-enhanced computed tomographic angiograms (CTA) in a 26-patient subset were analyzed to evaluate the number of patent intercostal and lumbar arteries before and after repair. Results: All patients were neurologically intact at the end of the operation. Seven (19%) patients developed LEW postoperatively: 6 perioperatively and 1 after discharge. LEW was associated with postoperative hypotension, internal iliac artery (IIA) occlusion, and fewer patent segmental arteries on preoperative CTA. Lowest mean systolic blood pressure was Conclusion: Endovascular TAAA repair inevitably occludes direct inflow to lumbar and intercostal arteries. The distal segments of these arteries to the spine, however, are seen to remain patent through collaterals. Measures to preserve collateral pathways and increase perfusion pressure may help prevent or treat LEW.
- 31 March 2007
- Published by Elsevier in Journal of Vascular Surgery
- Vol. 45 (3) , 461-466
Long-term outcome and reintervention after endovascular abdominal aortic aneurysm repair using the Zenith stent graft
- 31 March 2007
- Published by Elsevier in Journal of Vascular Surgery
- Vol. 45 (3) , 461-466
Long-term outcome and reintervention after endovascular abdominal aortic aneurysm repair using the Zenith stent graft
- Open Access
- 26 January 2007
- Published by Elsevier in Journal of Vascular Surgery
- Vol. 45 (3) , 472-474
The effect of magnetic resonance imaging on stainless-steel Z-stent–based abdominal aortic prosthesis
- 26 January 2007
- Published by Elsevier in Journal of Vascular Surgery
- Vol. 45 (3) , 472-474
Open AccessThe effect of magnetic resonance imaging on stainless-steel Z-stent–based abdominal aortic prosthesis
- 1 February 2006
- Published by International Society of Endovascular Specialists in Journal of Endovascular Therapy
- Vol. 13 (1) , 72-76
A Double-Barrel Stent-Graft for Endovascular Repair of the Aortic Arch
Purpose: To extend the role of endovascular aneurysm repair in the presence of angulation and dilatation of the distal arch that compromise the proximal implantation site. Case Report: A 70-year-old man with an asymptomatic 7-cm thoracic aortic aneurysm was treated with a TAG stent-graft. However, attempts to gain secure hemostatic implantation of the endograft resulted in inadvertent coverage of the subclavian and left carotid arteries. Flow to the left carotid artery was re-established by transcarotid insertion of a self-expanding covered stent alongside the primary stent-graft. Conclusion: This technique may have a role as an intended part of endovascular repair when there is no suitable implantation site in the descending thoracic aorta.
- 1 February 2006
- Published by International Society of Endovascular Specialists in Journal of Endovascular Therapy
- Vol. 13 (1) , 72-76
A Double-Barrel Stent-Graft for Endovascular Repair of the Aortic Arch
Purpose: To extend the role of endovascular aneurysm repair in the presence of angulation and dilatation of the distal arch that compromise the proximal implantation site. Case Report: A 70-year-old man with an asymptomatic 7-cm thoracic aortic aneurysm was treated with a TAG stent-graft. However, attempts to gain secure hemostatic implantation of the endograft resulted in inadvertent coverage of the subclavian and left carotid arteries. Flow to the left carotid artery was re-established by transcarotid insertion of a self-expanding covered stent alongside the primary stent-graft. Conclusion: This technique may have a role as an intended part of endovascular repair when there is no suitable implantation site in the descending thoracic aorta.