Dalton Marques Chaves
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Dalton Marques Chaves has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
P. Sakai
4 shared publicationsS. Ishioka
3 shared publications- Eduardo Guimarães Hourneaux de Moura
Hospital das Clinicas da Faculdade de Medicina da Universidade de São Paulo, São Paulo, Brazil
2 shared publications - Fauze Maluf-Filho
Department of Gastrointestinal Endoscopy, University of São Paulo, São Paulo, Brazil
2 shared publications Paulo Sakai
II Cancer Institute of São Paulo - São Paulo/SP, Brazil., Tel.: 55 11 3069.6221
2 shared publicationsS. Matuguma
2 shared publications
Latest Publications
- 10 February 2012
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 44 (S 02) , E99-E100
Splenic artery pseudoaneurysm treated with thrombin injection guided by endoscopic ultrasound
Thrombin was first described as an aneurysmal occlusion agent in 1986. Since that time its therapeutic potential has been increasingly recognized. Percutaneous injection of thrombin has been reported as effective in the management of femoral pseudoaneurysms [ 1 ] [ 2 ]. We present a case of pancreatic pseudoaneurysm of the splenic artery, which was successfully treated using a new approach that consisted of thrombin injection under endoscopic ultrasound (EUS) guidance. A 29-year-old man with a history of multiple episodes of acute pancreatitis, heavy alcohol consumption, and heavy smoking for 15 years complained of abdominal pain that worsened after meals. Examination by EUS of the pancreas identified a pseudoaneurysm at the level of the pancreatic body, which was represented by a well-defined, 4.5-cm maximal diameter echogenic lesion containing an anechoic area of 2 cm with flow detected by Doppler, which communicated with the splenic artery by a 4.5-mm neck ([ Fig. 1 ]). A complementary three-dimensional (3D) computed tomography (CT) angiogram was performed, which confirmed the EUS findings ([ Fig. 2 ]). Under EUS control 1 mL of thrombin (500 UI/mL) was injected into the lesion through the posterior gastric wall via a 22-G Echotip needle (Wilson Cook, Winston-Salem, North Carolina, USA), and instantaneous obliteration occurred ([ Fig. 3 ] and [ 4 ]). A small focal splenic infarction without clinical relevance was identified on a CT scan performed 1 week later, which was probably due distal embolization. A repeat CT angiogram and EUS performed 4 months later confirmed persistence of the occlusion ([ Fig. 5 ]). Fig. 1 Color Doppler image of the pseudoaneurysm. Fig. 2 Three-dimensional (3D) computed tomography (CT) angiogram showing the pseudoaneurysm of the splenic artery. Fig. 3 EUS image showing the needle inside the pseudoaneurysm. Fig. 4 EUS image taken immediately after the occurrence of thrombosis showing lack of flow within the splenic artery. Fig. 5 Three-dimensional (3D) computed tomography (CT) angiogram taken 4 months later showing the splenic artery without the pseudoaneurysm sac. There have been few reports published that describe the procedure of thrombin injection into visceral pseudoaneurysms under EUS guidance [ 3 ]. An important point to be considered is the presence of a small neck forming the communication between the pseudoaneurysm and the artery, which increases the success of the treatment and decreases the risk of distant embolization. EUS-guided treatment of visceral pseudoaneurysms with thrombin injection can be successfully performed. Although long-term follow-up is not yet available, the technique seems to be promising. Endoscopy_UCTN_Code_TTT_1AS_2AG
- 10 February 2012
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 44 (S 02) , E99-E100
Splenic artery pseudoaneurysm treated with thrombin injection guided by endoscopic ultrasound
Thrombin was first described as an aneurysmal occlusion agent in 1986. Since that time its therapeutic potential has been increasingly recognized. Percutaneous injection of thrombin has been reported as effective in the management of femoral pseudoaneurysms [ 1 ] [ 2 ]. We present a case of pancreatic pseudoaneurysm of the splenic artery, which was successfully treated using a new approach that consisted of thrombin injection under endoscopic ultrasound (EUS) guidance. A 29-year-old man with a history of multiple episodes of acute pancreatitis, heavy alcohol consumption, and heavy smoking for 15 years complained of abdominal pain that worsened after meals. Examination by EUS of the pancreas identified a pseudoaneurysm at the level of the pancreatic body, which was represented by a well-defined, 4.5-cm maximal diameter echogenic lesion containing an anechoic area of 2 cm with flow detected by Doppler, which communicated with the splenic artery by a 4.5-mm neck ([ Fig. 1 ]). A complementary three-dimensional (3D) computed tomography (CT) angiogram was performed, which confirmed the EUS findings ([ Fig. 2 ]). Under EUS control 1 mL of thrombin (500 UI/mL) was injected into the lesion through the posterior gastric wall via a 22-G Echotip needle (Wilson Cook, Winston-Salem, North Carolina, USA), and instantaneous obliteration occurred ([ Fig. 3 ] and [ 4 ]). A small focal splenic infarction without clinical relevance was identified on a CT scan performed 1 week later, which was probably due distal embolization. A repeat CT angiogram and EUS performed 4 months later confirmed persistence of the occlusion ([ Fig. 5 ]). Fig. 1 Color Doppler image of the pseudoaneurysm. Fig. 2 Three-dimensional (3D) computed tomography (CT) angiogram showing the pseudoaneurysm of the splenic artery. Fig. 3 EUS image showing the needle inside the pseudoaneurysm. Fig. 4 EUS image taken immediately after the occurrence of thrombosis showing lack of flow within the splenic artery. Fig. 5 Three-dimensional (3D) computed tomography (CT) angiogram taken 4 months later showing the splenic artery without the pseudoaneurysm sac. There have been few reports published that describe the procedure of thrombin injection into visceral pseudoaneurysms under EUS guidance [ 3 ]. An important point to be considered is the presence of a small neck forming the communication between the pseudoaneurysm and the artery, which increases the success of the treatment and decreases the risk of distant embolization. EUS-guided treatment of visceral pseudoaneurysms with thrombin injection can be successfully performed. Although long-term follow-up is not yet available, the technique seems to be promising. Endoscopy_UCTN_Code_TTT_1AS_2AG
- Open Access
- 1 September 2006
- Published by FapUNIFESP (SciELO) in Arquivos de Gastroenterologia
- Vol. 43 (3) , 191-195
Watermelon stomach: clinical aspects and treatment with argon plasma coagulation
BACKGROUND: Gastric antral vascular ectasia is a disorder whose pathogenetic mechanism is unknown. The endoscopic treatment with argon plasma coagulation has been considered one of the best endoscopic therapeutic options. AIM: To analyze the endoscopic and clinical features of gastric antral vascular ectasia and its response to the argon plasma coagulation treatment. PATIENTS AND METHODS: Eighteen patients were studied and classified into two groups: group 1 - whose endoscopic aspect was striped (watermelon) or of the diffuse confluent type; group 2 - diffuse spotty nonconfluent endoscopic aspect. RESULTS: Group 1 with eight patients, all having autoimmune antibodies, but one, whose antibodies were not searched for. Three were cirrhotic and three had hypothyroidism. All had gastric mucosa atrophy. In group 2, with 10 patients, all had non-immune liver disease, with platelet levels below 90.000. Ten patients were submitted to argon plasma coagulation treatment, with 2 to 36 months of follow-up. Lesions recurred in all patients who remained in the follow-up program and one did not respond to treatment for acute bleeding control. CONCLUSION: There seem to be two distinct groups of patients with gastric antral vascular ectasia: one related to immunologic disorders and other to non-immune chronic liver disease and low platelets. The endoscopic treatment using argon plasma coagulation had a high recurrence in the long-term evaluation.
- 1 September 2006
- Published by FapUNIFESP (SciELO) in Arquivos de Gastroenterologia
- Vol. 43 (3) , 191-195
Open AccessWatermelon stomach: clinical aspects and treatment with argon plasma coagulation
BACKGROUND: Gastric antral vascular ectasia is a disorder whose pathogenetic mechanism is unknown. The endoscopic treatment with argon plasma coagulation has been considered one of the best endoscopic therapeutic options. AIM: To analyze the endoscopic and clinical features of gastric antral vascular ectasia and its response to the argon plasma coagulation treatment. PATIENTS AND METHODS: Eighteen patients were studied and classified into two groups: group 1 - whose endoscopic aspect was striped (watermelon) or of the diffuse confluent type; group 2 - diffuse spotty nonconfluent endoscopic aspect. RESULTS: Group 1 with eight patients, all having autoimmune antibodies, but one, whose antibodies were not searched for. Three were cirrhotic and three had hypothyroidism. All had gastric mucosa atrophy. In group 2, with 10 patients, all had non-immune liver disease, with platelet levels below 90.000. Ten patients were submitted to argon plasma coagulation treatment, with 2 to 36 months of follow-up. Lesions recurred in all patients who remained in the follow-up program and one did not respond to treatment for acute bleeding control. CONCLUSION: There seem to be two distinct groups of patients with gastric antral vascular ectasia: one related to immunologic disorders and other to non-immune chronic liver disease and low platelets. The endoscopic treatment using argon plasma coagulation had a high recurrence in the long-term evaluation.
- 23 September 2004
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 36 (10) , 887-892
Removal of a Foreign Body from the Upper Gastrointestinal Tract with a Flexible Endoscope: a Prospective Study
Background and Study Aims: There have so far been no prospective studies on the value of flexible endoscopy for removing foreign bodies in the upper gastrointestinal tract. This study presents a clinical analysis of accidents with foreign bodies and prospectively evaluates the effectiveness of flexible endoscopy for removing them. Patients and Methods: A total of 105 cases of foreign-body ingestion in the upper gastrointestinal tract were evaluated, 29 (27.6 %) in children and 76 (72.4 %) in adults. Thirty patients (28.5 %) had esophageal strictures. Results: Thirty-nine of the foreign bodies (37.1 %) consisted of food and 66 (62.9 %) were not food-related. The success rate of foreign-body extraction using only a conventional flexible endoscope and accessories for treatment was 98.0 %, and with only a polypectomy snare and rat-toothed forceps it was 91.2 %. Complications at the moment of foreign-body removal occurred in nine patients (8.6 %); there was only one (1 %) esophageal perforation. The incidence of complications related to the duration of foreign-body impaction was six (10.5 %) with foreign bodies impacted for up to 24 h, 13 (52.0 %) for those impacted for 24 - 48 h, and three (60.0 %) for those impacted for 48 - 72 h (P < 0.05). Conclusions: The flexible endoscope is an effective and safe device for removing foreign bodies from the upper gastrointestinal tract, with a high success rate using only the polypectomy snare and the rat-toothed forceps as accessories. If foreign-body impaction lasts for more than 24 h, there is a significant increase in the incidence of complications.
- 23 September 2004
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 36 (10) , 887-892
Removal of a Foreign Body from the Upper Gastrointestinal Tract with a Flexible Endoscope: a Prospective Study
Background and Study Aims: There have so far been no prospective studies on the value of flexible endoscopy for removing foreign bodies in the upper gastrointestinal tract. This study presents a clinical analysis of accidents with foreign bodies and prospectively evaluates the effectiveness of flexible endoscopy for removing them. Patients and Methods: A total of 105 cases of foreign-body ingestion in the upper gastrointestinal tract were evaluated, 29 (27.6 %) in children and 76 (72.4 %) in adults. Thirty patients (28.5 %) had esophageal strictures. Results: Thirty-nine of the foreign bodies (37.1 %) consisted of food and 66 (62.9 %) were not food-related. The success rate of foreign-body extraction using only a conventional flexible endoscope and accessories for treatment was 98.0 %, and with only a polypectomy snare and rat-toothed forceps it was 91.2 %. Complications at the moment of foreign-body removal occurred in nine patients (8.6 %); there was only one (1 %) esophageal perforation. The incidence of complications related to the duration of foreign-body impaction was six (10.5 %) with foreign bodies impacted for up to 24 h, 13 (52.0 %) for those impacted for 24 - 48 h, and three (60.0 %) for those impacted for 48 - 72 h (P < 0.05). Conclusions: The flexible endoscope is an effective and safe device for removing foreign bodies from the upper gastrointestinal tract, with a high success rate using only the polypectomy snare and the rat-toothed forceps as accessories. If foreign-body impaction lasts for more than 24 h, there is a significant increase in the incidence of complications.
- 19 August 2003
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 35 (09) , 800-801
Hand-Made Loop Applied With Snare to Prevent Postpolypectomy Bleeding
Hemorrhage is the most common complication associated with resection of colorectal polyps. In large polyps specifically, the occurrence either during the procedure or afterwards as an early or late complication can be as high as 24 % overall [ 1 ]. To prevent postpolypectomy hemorrhage, we have devised a loop made of standard nylon fishing line which is applied using a polypectomy snare. To make the loop we used a nylon fishing line of gauge number 0.60, constructing a knot as illustrated in Fig. [ 1 ]. The size of the loop depended upon the size of the polyp. After constructing the loop we attached it to the end of a conventional polypectomy snare, which was introduced through the working channel with the device already assembled. The polyp stalk was correctly identified and then ligated with the nylon loop. Polypectomy using a conventional diathermic snare above the nylon loop was then carried out (Fig. [ 2 ]). In order to close the large loop it is necessary to disconnect the snare from the grip. We recommend the use of a diathermic snare with a high resistance catheter which should be elongated when tightening the loop. Figure 1 Construction of the loop. a Grasp the two ends of the line, and pass one of the ends around the held sections, as shown. b After the third turn, pass the end of the line inside the loop formed with the first turn. c Cut the ends of the the line, allowing a length of 0.5 cm for one end and 2.0 cm for the other, which is then bent round. d Attach the bent end to the polypectomy snare, anchoring the knot in the tip of the snare. Figure 2 Polyp resection after banding the pedicle using a loop. a Pedunculated polyp. b Ligating the pedicle with the loop. c Loop securing the pedicle after resection of the polyp. To date there are few studies about the efficacy of ligating the polyp stalk to prevent hemorrhage. When Iishi et al. [ 2 ] applied a loop in large polyps, no hemorrhage was observed during or after the procedure, whereas it occurred in 12 % of patients in the control group. Matsushita et al. [ 3 ] observed that the loop did not securely bind subpedunculated polyps, or vascular stumps after polypectomy. The hand-made loop described here has been shown to be practical and efficient in ligating the polyp stalk before polypectomy.
- 19 August 2003
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 35 (09) , 800-801
Hand-Made Loop Applied With Snare to Prevent Postpolypectomy Bleeding
Hemorrhage is the most common complication associated with resection of colorectal polyps. In large polyps specifically, the occurrence either during the procedure or afterwards as an early or late complication can be as high as 24 % overall [ 1 ]. To prevent postpolypectomy hemorrhage, we have devised a loop made of standard nylon fishing line which is applied using a polypectomy snare. To make the loop we used a nylon fishing line of gauge number 0.60, constructing a knot as illustrated in Fig. [ 1 ]. The size of the loop depended upon the size of the polyp. After constructing the loop we attached it to the end of a conventional polypectomy snare, which was introduced through the working channel with the device already assembled. The polyp stalk was correctly identified and then ligated with the nylon loop. Polypectomy using a conventional diathermic snare above the nylon loop was then carried out (Fig. [ 2 ]). In order to close the large loop it is necessary to disconnect the snare from the grip. We recommend the use of a diathermic snare with a high resistance catheter which should be elongated when tightening the loop. Figure 1 Construction of the loop. a Grasp the two ends of the line, and pass one of the ends around the held sections, as shown. b After the third turn, pass the end of the line inside the loop formed with the first turn. c Cut the ends of the the line, allowing a length of 0.5 cm for one end and 2.0 cm for the other, which is then bent round. d Attach the bent end to the polypectomy snare, anchoring the knot in the tip of the snare. Figure 2 Polyp resection after banding the pedicle using a loop. a Pedunculated polyp. b Ligating the pedicle with the loop. c Loop securing the pedicle after resection of the polyp. To date there are few studies about the efficacy of ligating the polyp stalk to prevent hemorrhage. When Iishi et al. [ 2 ] applied a loop in large polyps, no hemorrhage was observed during or after the procedure, whereas it occurred in 12 % of patients in the control group. Matsushita et al. [ 3 ] observed that the loop did not securely bind subpedunculated polyps, or vascular stumps after polypectomy. The hand-made loop described here has been shown to be practical and efficient in ligating the polyp stalk before polypectomy.
- 22 February 2002
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 34 (03) , 199-202
Comparative Study of Portal Hypertensive Gastropathy in Schistosomiasis and Hepatic Cirrhosis
Background and Study Aims: Portal hypertensive gastropathy (PHG) is a common finding in chronic liver disease, but it has not been evaluated in hepatosplenic schistosomiasis, a significant cause of noncirrhotic portal hypertension worldwide. Our study was aimed at comparing cirrhosis with hepatosplenic schistosomiasis with regard to the endoscopic and histological findings of PHG. Patients and Methods: We included 43 patients with a history of upper digestive hemorrhage, 22 with cirrhosis and 21 with schistosomiasis, without previous surgical or endoscopic treatment. Upper digestive endoscopies with macrobiopsies of the gastric body were prospectively performed in all cases. Results: The endoscopic signs of PHG were more prevalent in cirrhosis than schistosomiasis (81.8 % vs. 33.3 %; P < 0.05), and the mosaic pattern was the main finding. Histological abnormalities were evenly distributed. Conclusions: In agreement with other investigations, this study shows a lower prevalence of endoscopic findings of portal hypertensive gastropathy in noncirrhotic diseases. This difference cannot be explained by the underlying microscopic alterations, which were similar in both groups, suggesting that other factors must play a role in its pathogenesis.
- 22 February 2002
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 34 (03) , 199-202
Comparative Study of Portal Hypertensive Gastropathy in Schistosomiasis and Hepatic Cirrhosis
Background and Study Aims: Portal hypertensive gastropathy (PHG) is a common finding in chronic liver disease, but it has not been evaluated in hepatosplenic schistosomiasis, a significant cause of noncirrhotic portal hypertension worldwide. Our study was aimed at comparing cirrhosis with hepatosplenic schistosomiasis with regard to the endoscopic and histological findings of PHG. Patients and Methods: We included 43 patients with a history of upper digestive hemorrhage, 22 with cirrhosis and 21 with schistosomiasis, without previous surgical or endoscopic treatment. Upper digestive endoscopies with macrobiopsies of the gastric body were prospectively performed in all cases. Results: The endoscopic signs of PHG were more prevalent in cirrhosis than schistosomiasis (81.8 % vs. 33.3 %; P < 0.05), and the mosaic pattern was the main finding. Histological abnormalities were evenly distributed. Conclusions: In agreement with other investigations, this study shows a lower prevalence of endoscopic findings of portal hypertensive gastropathy in noncirrhotic diseases. This difference cannot be explained by the underlying microscopic alterations, which were similar in both groups, suggesting that other factors must play a role in its pathogenesis.