Daniele S. Lantagne
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Daniele S. Lantagne has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Kelsey Preston
Department of Civil and Environmental Engineering , Lehigh University , Bethlehem , Pennsylvania , USA
2 shared publicationsKristen Jellison
Department of Civil and Environmental Engineering , Lehigh University , Bethlehem , Pennsylvania , USA
2 shared publicationsAlly Mayer
Department of Civil and Environmental Engineering , Lehigh University , Bethlehem , Pennsylvania , USA
1 shared publicationB. C. Blount
Division of Laboratory Sciences, National Center for Environmental Health, U.S. Centers for Disease Control and Prevention, Atlanta, GA 30341, USA
1 shared publicationBen C. Blount
1 shared publicationE. Blanton
Public Health Engineer, Enteric Diseases Epidemiology Branch, Centers for Disease Control and Prevention, 1600 Clifton Rd., MS-A38, Atlanta, GA 30333
1 shared publication
Latest Publications
- 1 February 2011
- Published by American Society of Civil Engineers (ASCE) in Journal of Environmental Engineering
- Vol. 137 (2) , 131-136
Hypochlorite Solution Expiration and Stability in Household Water Treatment in Developing Countries
Household water treatment with dilute hypochlorite solution has been shown to improve microbiological water quality and reduce diarrheal disease in developing countries. One concern raised by governmental agencies, implementers, and nongovernmental organizations is whether the hypochlorite solution remains stable during distribution and after the bottle is opened and usage begins. In this study, laboratory and field research was conducted to determine the expiration date and stability in the home of hypochlorite solution. Expiration-date testing found that pH-stabilized ∼1.25% hypochlorite solution made using various production techniques in Ethiopia, Guinea, and Nigeria was stable for a minimum of 12 months in temperatures less than 35°C . Stability testing during laboratory simulated normal usage showed no degradation, and 77–91% of bottles collected from households tested met standards. Hypochlorite solution concentration drops rapidly when pH is not stabilized, when pH levels fall, and when solution i...
- 1 February 2011
- Published by American Society of Civil Engineers (ASCE) in Journal of Environmental Engineering
- Vol. 137 (2) , 131-136
Hypochlorite Solution Expiration and Stability in Household Water Treatment in Developing Countries
Household water treatment with dilute hypochlorite solution has been shown to improve microbiological water quality and reduce diarrheal disease in developing countries. One concern raised by governmental agencies, implementers, and nongovernmental organizations is whether the hypochlorite solution remains stable during distribution and after the bottle is opened and usage begins. In this study, laboratory and field research was conducted to determine the expiration date and stability in the home of hypochlorite solution. Expiration-date testing found that pH-stabilized ∼1.25% hypochlorite solution made using various production techniques in Ethiopia, Guinea, and Nigeria was stable for a minimum of 12 months in temperatures less than 35°C . Stability testing during laboratory simulated normal usage showed no degradation, and 77–91% of bottles collected from households tested met standards. Hypochlorite solution concentration drops rapidly when pH is not stabilized, when pH levels fall, and when solution i...
- 1 July 2010
- Published by American Society of Tropical Medicine and Hygiene in The American Journal of Tropical Medicine and Hygiene
- Vol. 83 (1) , 135-143
Disinfection By-Product Formation and Mitigation Strategies in Point-of-Use Chlorination with Sodium Dichloroisocyanurate in Tanzania
Almost a billion persons lack access to improved drinking water, and diarrheal diseases cause an estimated 1.87 million deaths per year. Sodium dichloroisocyanurate (NaDCC) tablets are widely recommended for household water treatment to reduce diarrhea. Because NaDCC is directly added to untreated water sources, concerns have been raised about the potential health impact of disinfection by-products. This study investigated trihalomethane (THM) production in water from six sources used for drinking (0.6–888.5 nephelometric turbidity units) near Arusha, Tanzania. No sample collected at 1, 8, and 24 hours after NaDCC addition exceeded the World Health Organization guideline values for either individual or total THMs. Ceramic filtration, sand filtration, cloth filtration, and settling and decanting were not effective mitigation strategies to reduce THM formation. Chlorine residual and THM formation were not significantly different in NaDCC and sodium hypochlorite treatment. Household chlorination of turbid and non-turbid waters did not create THM concentrations that exceeded health risk guidelines.
- 1 July 2010
- Published by American Society of Tropical Medicine and Hygiene in The American Journal of Tropical Medicine and Hygiene
- Vol. 83 (1) , 135-143
Disinfection By-Product Formation and Mitigation Strategies in Point-of-Use Chlorination with Sodium Dichloroisocyanurate in Tanzania
Almost a billion persons lack access to improved drinking water, and diarrheal diseases cause an estimated 1.87 million deaths per year. Sodium dichloroisocyanurate (NaDCC) tablets are widely recommended for household water treatment to reduce diarrhea. Because NaDCC is directly added to untreated water sources, concerns have been raised about the potential health impact of disinfection by-products. This study investigated trihalomethane (THM) production in water from six sources used for drinking (0.6–888.5 nephelometric turbidity units) near Arusha, Tanzania. No sample collected at 1, 8, and 24 hours after NaDCC addition exceeded the World Health Organization guideline values for either individual or total THMs. Ceramic filtration, sand filtration, cloth filtration, and settling and decanting were not effective mitigation strategies to reduce THM formation. Chlorine residual and THM formation were not significantly different in NaDCC and sodium hypochlorite treatment. Household chlorination of turbid and non-turbid waters did not create THM concentrations that exceeded health risk guidelines.
- 15 February 2010
- Published by Taylor & Francis in International Journal of Environmental Health Research
- Vol. 20 (3) , 171-187
Effect of production variables on microbiological removal in locally-produced ceramic filters for household water treatment
Diarrhoeal diseases cause an estimated 1.87 million child deaths per year. Point-of-use filtration using locally made ceramic filters improves microbiological quality of stored drinking water and prevents diarrhoeal disease. Scaling-up ceramic filtration is inhibited by lack of universal quality control standards. We investigated filter production variables to determine their affect on microbiological removal during 5–6 weeks of simulated normal use. Decreases in the clay:sawdust ratio and changes in the burnable decreased effectiveness of the filter. Method of silver application and shape of filter did not impact filter effectiveness. A maximum flow rate of 1.7 l−hr was established as a potential quality control measure for one particular filter to ensure 99% (2- log10) removal of total coliforms. Further research is indicated to determine additional production variables associated with filter effectiveness and develop standardized filter production procedures prior to scaling-up.
- 15 February 2010
- Published by Taylor & Francis in International Journal of Environmental Health Research
- Vol. 20 (3) , 171-187
Effect of production variables on microbiological removal in locally-produced ceramic filters for household water treatment
Diarrhoeal diseases cause an estimated 1.87 million child deaths per year. Point-of-use filtration using locally made ceramic filters improves microbiological quality of stored drinking water and prevents diarrhoeal disease. Scaling-up ceramic filtration is inhibited by lack of universal quality control standards. We investigated filter production variables to determine their affect on microbiological removal during 5–6 weeks of simulated normal use. Decreases in the clay:sawdust ratio and changes in the burnable decreased effectiveness of the filter. Method of silver application and shape of filter did not impact filter effectiveness. A maximum flow rate of 1.7 l−hr was established as a potential quality control measure for one particular filter to ensure 99% (2- log10) removal of total coliforms. Further research is indicated to determine additional production variables associated with filter effectiveness and develop standardized filter production procedures prior to scaling-up.
- 1 November 2009
- Published by American Public Health Association in American Journal of Public Health
- Vol. 99 (11) , 1975-1978
Viability of Commercially Available Bleach for Water Treatment in Developing Countries
Treating household water with low-cost, widely available commercial bleach is recommended by some organizations to improve water quality and reduce disease in developing countries. I analyzed the chlorine concentration of 32 bleaches from 12 developing countries; the average error between advertised and measured concentration was 35% (range = –45%–100%; standard deviation = 40%). Because of disparities between advertised and actual concentration, the use of commercial bleach for water treatment in developing countries is not recommended without ongoing quality control testing.
- 1 November 2009
- Published by American Public Health Association in American Journal of Public Health
- Vol. 99 (11) , 1975-1978
Viability of Commercially Available Bleach for Water Treatment in Developing Countries
Treating household water with low-cost, widely available commercial bleach is recommended by some organizations to improve water quality and reduce disease in developing countries. I analyzed the chlorine concentration of 32 bleaches from 12 developing countries; the average error between advertised and measured concentration was 35% (range = –45%–100%; standard deviation = 40%). Because of disparities between advertised and actual concentration, the use of commercial bleach for water treatment in developing countries is not recommended without ongoing quality control testing.
- 1 May 2009
- Published by IWA Publishing in Journal of Water and Health
- Vol. 7 (3) , 497-506
Turbidity and chlorine demand reduction using locally available physical water clarification mechanisms before household chlorination in developing countries
Over 1.1 billion people in the world lack access to improved drinking water. Diarrhoeal and other waterborne diseases cause an estimated 1.9 million deaths per year. The Safe Water System (SWS) is a proven household water treatment intervention that reduces diarrhoeal disease incidence among users in developing countries. Turbid waters pose a particular challenge to implementation of SWS programmes; although research shows that a 3.75 mg l−1 sodium hypochlorite dose effectively treats turbid waters, users sometimes object to the strong chlorine taste and prefer to drink water that is more aesthetically pleasing. This study investigated the efficacy of three locally available water clarification mechanisms—cloth filtration, settling/decanting and sand filtration—to reduce turbidity and chlorine demand at turbidities of 10, 30, 70, 100 and 300 NTU. All three mechanisms reduced turbidity (cloth filtration −1–60%, settling/decanting 78–88% and sand filtration 57–99%). Sand filtration (P=0.002) and settling/decanting (P=0.004), but not cloth filtration (P=0.30), were effective at reducing chlorine demand compared with controls. Recommendations for implementing organizations based on these results are discussed.
- 1 May 2009
- Published by IWA Publishing in Journal of Water and Health
- Vol. 7 (3) , 497-506
Turbidity and chlorine demand reduction using locally available physical water clarification mechanisms before household chlorination in developing countries
Over 1.1 billion people in the world lack access to improved drinking water. Diarrhoeal and other waterborne diseases cause an estimated 1.9 million deaths per year. The Safe Water System (SWS) is a proven household water treatment intervention that reduces diarrhoeal disease incidence among users in developing countries. Turbid waters pose a particular challenge to implementation of SWS programmes; although research shows that a 3.75 mg l−1 sodium hypochlorite dose effectively treats turbid waters, users sometimes object to the strong chlorine taste and prefer to drink water that is more aesthetically pleasing. This study investigated the efficacy of three locally available water clarification mechanisms—cloth filtration, settling/decanting and sand filtration—to reduce turbidity and chlorine demand at turbidities of 10, 30, 70, 100 and 300 NTU. All three mechanisms reduced turbidity (cloth filtration −1–60%, settling/decanting 78–88% and sand filtration 57–99%). Sand filtration (P=0.002) and settling/decanting (P=0.004), but not cloth filtration (P=0.30), were effective at reducing chlorine demand compared with controls. Recommendations for implementing organizations based on these results are discussed.
- 1 November 2007
- Published by IWA Publishing in Journal of Water and Health
- Vol. 6 (1) , 67-82
Disinfection by-product formation and mitigation strategies in point-of-use chlorination of turbid and non-turbid waters in western Kenya
Over 1.1 billion people in the world lack access to improved drinking water. Diarrheal and other waterborne diseases cause an estimated 2.2 million deaths per year. The Safe Water System (SWS) is a proven household water treatment intervention that reduces diarrheal disease incidence in users in developing countries. Because the SWS recommends the addition of sodium hypochlorite to unfiltered water sources, concerns have been raised about the potential long-term health effects of disinfection by-products to SWS users. This study investigated the production of trihalomethanes (THMs) in water treated with sodium hypochlorite from six sources used for drinking water in western Kenya. The turbidity values of these sources ranged from 4.23 NTU to 305 NTU. THM concentrations were analysed at 1, 8, and 24 hours after addition of sodium hypochlorite. No sample exceeded the World Health Organization (WHO) guideline values for any of the four THMs: chloroform, bromodichloromethane, dibromochloromethane, or bromoform. In addition, no sample exceeded the WHO additive total THM guideline value. These results clearly show that point-of-use chlorination of a variety of realistic source waters used for drinking did not lead to THM concentrations that pose a significant health risk to SWS users.
- 1 November 2007
- Published by IWA Publishing in Journal of Water and Health
- Vol. 6 (1) , 67-82
Disinfection by-product formation and mitigation strategies in point-of-use chlorination of turbid and non-turbid waters in western Kenya
Over 1.1 billion people in the world lack access to improved drinking water. Diarrheal and other waterborne diseases cause an estimated 2.2 million deaths per year. The Safe Water System (SWS) is a proven household water treatment intervention that reduces diarrheal disease incidence in users in developing countries. Because the SWS recommends the addition of sodium hypochlorite to unfiltered water sources, concerns have been raised about the potential long-term health effects of disinfection by-products to SWS users. This study investigated the production of trihalomethanes (THMs) in water treated with sodium hypochlorite from six sources used for drinking water in western Kenya. The turbidity values of these sources ranged from 4.23 NTU to 305 NTU. THM concentrations were analysed at 1, 8, and 24 hours after addition of sodium hypochlorite. No sample exceeded the World Health Organization (WHO) guideline values for any of the four THMs: chloroform, bromodichloromethane, dibromochloromethane, or bromoform. In addition, no sample exceeded the WHO additive total THM guideline value. These results clearly show that point-of-use chlorination of a variety of realistic source waters used for drinking did not lead to THM concentrations that pose a significant health risk to SWS users.