TKTakeshi Karino

Takeshi Karino

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Takeshi Karino has a total of 5 co-authors. Here are the top co-authors by number of shared publications:

  • Li-Jie Fan

    Laboratory of Biofluid Dynamics, Research Institute for Electronic Science, Hokkaido University, Sapporo 060-0812, Japan

    1 shared publication
  • Lijie Fan

    Laboratory of Biofluid Dynamics, Research Institute for Electronic Science, Hokkaido University, Sapporo, Japan

    1 shared publication
  • Nobuaki Kobayashi

    Sapporo Kita Neurosurgical Clinic, Sapporo, Japan

    1 shared publication
  • Nobuaki Kobayashi

    Cardiovascular Medicine, Nippon Medical School Chiba Hokusoh Hospital, Inzai 270-1694, Japan

    1 shared publication
  • Yoko Eguchi

    Laboratory of Biofluid Dynamics, Research Institute for Electronic Science, Hokkaido University, North 12, West 6, North District, Sapporo, 060-0812, Japan

    1 shared publication

Latest Publications

  • Flow patterns and velocity distributions in the human vertebrobasilar arterial system

    by Nobuaki Kobayashi, Takeshi Karino

    The authors conducted a study to elucidate the relationship between the flow patterns and the formation of aneurysms at the bifurcation of the basilar artery (BA). Six isolated, transparent vertebrobasilar arterial systems were prepared from humans postmortem, and flow patterns and velocity distributions were studied in detail using flow visualization and cinemicrographic techniques. The authors found that if the diameters of 2 vertebral arteries (VAs) were nearly equal and they formed a symmetrical inverted Y-shaped junction with the BA, the BA flow was also symmetrical. The fluid elements that flowed into the BA from 2 VAs traveled almost parallel to the vessel wall of the BA without mixing with each other, and then they flowed out through ipsilateral superior cerebellar and posterior cerebral arteries. In contrast to this, if the diameters of 2 VAs were very different or the BA was badly bent, the BA flow was disturbed as a result of the formation of swirling and secondary flows. The approaching velocity profile at the BA's terminal bifurcation was flattened if the inverted Y-junction was symmetrical, and it was sharpened if the junction was asymmetrical. Thus, in the latter case, fluid elements impinged on the vessel wall around the flow divider of the bifurcation with much larger velocities and, hence, larger kinetic energy, compared with the case of a symmetrical inverted Y-junction, exerting high fluid pressures, wall shear stresses, and wall tensions on the vessel wall there. The symmetrical structure of the inverted Y-junction in a normal vertebrobasilar arterial system provides a flattened approaching velocity profile at the terminal bifurcation of the BA, lowering the hemodynamic stresses (pressure, tension, and shear stress) exerted on the wall of the bifurcation. This may account for the relatively low incidence of aneurysm formation at this site.


  • Effect of a disturbed flow on proliferation of the cells of a hybrid vascular graft

    by Lijie Fan, Takeshi Karino

    Atherosclerotic lesions and intimal hyperplasia develop preferentially in regions where blood flow is disturbed by the formation of secondary and recirculation flows. Hence, to investigate the mechanism of the localization of these vascular diseases,


  • Effect of serum concentration on adhesion of monocytic THP-1 cells onto cultured EC monolayer and EC-SMC co-culture

    by Li-Jie Fan, Takeshi Karino

    The adhesion of monocytes to the endothelium following accumulation of low-density lipoprotein (LDL) in subendothelial spaces is an important step in the development of intimal hyperplasia in arterially implanted vein grafts and atherosclerosis in both animals and humans. However, it is not well known how serum factors affect the adhesion of monocytes. We have studied the effect of fetal calf serum (FCS), which we considered a source of LDL, on the adhesion of monocytes to endothelial cells (ECs) by using human monocytic THP-1 cells and both a monolayer of cultured bovine aortic endothelial cells (EC monoculture) and a co-culture with bovine aortic smooth muscle cells (EC-SMC co-culture). It was found that the addition of FCS to the medium greatly affected the adhesion of THP-1 cells, and the higher the concentration of FCS in the medium, the greater the adhesion of THP-1 cells to endothelial cells. Adhesion of THP-1 cells to an EC-SMC co-culture was approximately twofold greater than that to an EC monoculture, and after adhering to endothelial cells, many THP-1 cells transmigrated into the layer of smooth muscle cells. The results suggest that the elevation of the LDL (cholesterol) level in blood provides a favorable condition for the development of intimal hyperplasia and atherosclerosis by promoting the adhesion of monocytes to the endothelium and their subsequent migration into subendothelial spaces.


  • Measurement of Rheologic Property of Blood by a Falling-Ball Blood Viscometer

    by Yoko Eguchi, Takeshi Karino

    The viscosity of blood obtained by using a rotational viscometer decreases with the time elapsed from the beginning of measurement until it reaches a constant value determined by the magnitude of shear rate. It is not possible to obtain an initial value of viscosity at time t = 0 that is considered to exhibit an intrinsic property of the fluid by this method. Therefore, we devised a new method by which one can obtain the viscosity of various fluids that are not affected by both the time elapsed from the beginning of measurement and the magnitude of shear rate by considering the balance of the forces acting on a solid spherical particle freely falling in a quiescent viscous fluid. By using the new method, we studied the rheologic behavior of corn syrups, carboxy-methyl cellulose, and human blood; and compared the results with those obtained with a cone-and-plate viscometer. It was found that in the case of corn syrups and washed red cell suspensions in which no red cell aggregate (rouleau) was formed, the viscosity obtained with the two different methods were almost the same. In contrast to this, in the case of the whole blood in which massive aggregates were formed, the viscosity obtained with a falling-ball viscometer was much larger than that obtained with a cone-plate viscometer.