RERichard Edlich

Richard Edlich

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Richard Edlich has a total of 46 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Revolutionary advances in enhancing patient comfort on patients transported on a backboard

    by Richard F. Edlich, Shelley S. Mason, Rober J. Vissers, K. Dean Gubler, John G. Thacker, Paul Pharr, Mark Anderson, William B. Long


  • Open Access

    Guardian ad litem, a potentially expensive invitation to either the mismanagement or management of patients with cognitive disorders

    by Richard Edlich

    Peer reviewed article authored by (Richard F Edlich). Read article or submit your manuscript for publishing.


  • A Need for Reorganization of the Food and Drug Administration

    by Richard Edlich, Shelley S. Mason, Jill S. Reddig, K. Dean Gubler, William B. Long Iii

    The associate director for science and medicine in the Office of Drug Safety at the Food and Drug Administration (FDA), Dr. David Graham, reported that the FDA was incapable of protecting Americans from unsafe drugs. In testimony to the Senate Finance Committee, he stated that the FDA has let the American people down and betrayed public trust. Drastic changes and measures within the FDA must be made to ensure the safety of American consumers of drugs, products, and medical devices. Efforts such as the introduction of the Grassley-Dodd Bill, allowing the FDA to order immediate drug recall or increased risk warnings, followed by the FDA Safety Act of 2007, are still not enough to ensure the safety and efficacy of drugs, biological products, and medical devices that the American public use every day. In this report, we describe past and present efforts by congressional leaders, FDA representatives, and American citizens to effect changes within the FDA in order to protect America from unsafe drugs and medical devices. We describe our own struggles in passing a citizen’s petition to ban cornstarch in medical gloves, and the lack of response and responsibility that the FDA has displayed.

  • Revolutionary Advances in the Diagnosis of Vitamin D Deficiency

    by Richard Edlich, Shelley S. Mason, Jill S. Reddig, K. Dean Gubler, William B. Long Iii

    Vitamin D deficiency has bee associated with bone diseases, cardiovascular diseases, cancer, and multiple sclerosis. Recent clinical studies have pointed out that these diseases could be prevented by either adequate sun exposure or oral vitamin D3 supplementation. In an effort to prevent these illnesses, emergency physicians and other clinicians must be aware of technological advances in the measurement of serum concentrations of 25-hydroxyvitamin D. Realizing the importance of diagnosing vitamin D deficiency, we reviewed the following advanced diagnostic techniques: liquid chromatography tandem mass spectrometry, radioimmunoassay, and DiaSorin’s immunochemiluminometric automated analyzer LIASION®. On the basis of this review, we have found that each of these diagnostic tests has documented limitations, and therefore we recommend an international standardization of these assays to accurately diagnose vitamin D deficiency.


  • An Injury Prevention Program to Prevent Gymnastic Injuries in Children and Teenagers

    by Richard Edlich, Erin M. Swainston, Jill J. Dahlstrom, K. Dean Gubler, William B. Long Iii, Jeffrey Beaton

    There are more than 5 million participants in 1 of 6 gymnastic disciplines that are prone to spinal cord injuries. Working with the gifted scholar and attorney, Jeffrey Beaton, the authors have participated in developing an injury prevention program for children and teenagers who participate in gymnastics. This program includes the following components: (1) a gymnastics center that complies with the e-Book design of gymnasticszone.com; (2) all teachers and students in gymnastics should be members of USA Gymnastics (USAG) and purchase a copy of the USA Gymnastics Safety Manual, the official manual of the United States Gymnastics Safety Association; (3) trampolines should be sunk in the ground with the bed level with the floor; and finally, (4) immediate emergency access of the injured gymnast to either a skilled orthopedic or neurosurgeon.


  • Nursing Home Fractures: A Challenge and a Solution

    by Richard Edlich, Shelley S. Mason, Erin M. Swainston, Jill J. Dahlstrom, K. Dean Gubler, William B. Long Iii

    Hip fracture occurrences in nursing homes are associated with high morbidity, mortality, and high health care costs in elderly people. In the United States, approximately 340,000 hip fractures occur each year, while more then 90% are associated with falls. Osteoporosis is a skeletal disorder causing impaired bone strength that increases the risk of fracture. In the United States alone, osteoporosis affects < 10 million individuals aged > or =50. The American Association of Clinical Endocrinologists (AACE), North American Menopause Society (NAMS), and National Osteoporosis Foundation (NOF) have developed recommendations for the identification of patients with osteoporosis who need therapy. Good nutrition with adequate supplements of calcium and vitamin D3 is considered one of the most important lifestyle factors for maintaining adequate bone mineral density. Only a combination of calcium and vitamin D therapy has been shown to increase the bone mineral density as well as a reduction in the nonvertebral fractures.

  • Scientifi c Basis for the Selection of Vascular Closure Techniques

    by Richard Edlich, K. Dean Gubler, Anne G. Wallis, Jamie J. Clark, Jill J. Dahlstrom, William B. Long Iii

    If this educational program heightens the surgeon's, resident's, and student's interest in the biology of vascular wound closure and infection, the long years occupied in our search for improved methods of wound management would more than fulfill our expectations. As with any master surgeon, he/she must understand the tools of his/her profession. This linkage between a surgeon and surgical equipment is a closed kinematic chain in which the surgeon's power is converted into finely coordinated movements that result in vascular wound closure with the least possible scar and without infection. The description of wound repair of blood vessels will be confined to arterial surgery in which the surgeon attempts to establish a new non-wettable intima and to reestablish a strong elastic muscular media. Repair of vessel wall wounds is encountered in arteriotomy for vascular access as well as in artery-to-artery anastomoses. In both circumstances, wound repair is primarily at the suture line. The surgical needles of SynetureTM are produced from stainless steel alloys, which have excellent resistance to corrosion. A new high-nickel stainless steel, SURGALLOYTM, has been used recently by SynetureTM to manufacture surgical needles. We prefer a polybutester monofilament suture whose surface is coated with an absorbable polymer. This absorbable coating of the VASCUFILTM monofilament sutures markedly reduces its drag forces in vascular tissue. The surgeon can practice using these sutures in femoral arteriotomies in animals.

  • Scientifi c Basis for the Selection of Skin Closure Techniques

    by Richard Edlich, K. Dean Gubler, Anne G. Wallis, Jamie J. Clark, Jill J. Dahlstrom, William B. Long Iii

    This scientific article was designed to teach the individual reader the scientific basis for suture and needle selection as well as to illustrate the appropriate surgical techniques involved in wound repair of skin incisions. Because the US Food and Drug Administration permits 1.5% of the sterile surgical gloves to have holes, the operating room personnel should wear sterile surgical double-glove hole indication systems that detect holes in the outer glove. From the surgeon's point of view, the rate of gain of strength of the skin wound is a key determinant of many decisions including when the suture can be removed, the level of patient activity, and the selection of the incision. Important considerations in wound closure are type of suture and mechanical performance, in vivo and in vitro. Measurements of the in vivo degradation of sutures separate them into two general classes, absorbable and nonabsorbable. Sutures that undergo rapid degradation in tissues, losing their tensile strength within 60 days, are considered absorbable. Those that maintain their tensile strength for longer than 60 days are considered nonabsorbable. For skin closure with nonabsorbable suture, we favor the use of the polybutester suture that is coated with an absorbable polymer, VASCUFILTM. When absorbable sutures are used for a dermal skin closure, the synthetic monofilament MAXONTM is recommended. Absorption of the suture is complete between 90 and 110 days. In either case, we would recommend that the suture be attached by a swage attachment to a SURGALLOYTM reverse cutting stainless steel suture. Continuous percutaneous suture closure has definite, distinct advantages over interrupted suture closure. Although continuous dermal wound closure is technically more challenging for the surgeon than interrupted dermal suture closure, it has become an important wound closure technique. A monofilament absorbable synthetic MAXONTM attached to a reverse cutting edge SURGALLOYTM stainless steel needle is ideally suited for continuous dermal skin suture closure.


  • Wound Closure Sutures and Needles: A New Perspective

    by Richard Edlich, K. Dean Gubler, Anne G. Wallis, Jamie J. Clark, Jill J. Dahlstrom, William B. Long Iii

    Ideally, the choice of the suture material should be based on the biological interaction of the materials employed, the tissue configuration, and the biomechanical properties of the wound. Measurements of the in vivo degradation of sutures separate them into two general classes: absorbable and nonabsorbable sutures. The nonabsorbable sutures and absorbable sutures are classified according to their origin. When considering an absorbable suture’s tensile strength in vivo, we recommend that the manufacturer provides specific recommendations of its holding strength, rather than the percentage retained of its initial tensile strength. The newest advance in nonabsorbable sutures is polybutester suture, which is a block copolymer that contains butylene terephthalate (84%) and polytetramethylene ether glycol terephthalate (16%). The expanded polytetrafluoroethylene (ePTFE) suture has been expanded to produce a porous microstructure that is approximately 50% air by volume. The clinical performance of polybutester suture has been enhanced by coating its surface with a unique absorbable polymer. A search for a synthetic substitute for absorbable collagen sutures led to the development of the POLYSORBTM sutures that can reliably approximate tissues with a low risk for infection. The latest innovation in the development of monofilament absorbable sutures has been in the rapidly absorbing CAPROSYNTM suture. A new high-nickel stainless steel, SURGALLOYTM, has been used recently to manufacture surgical needles. Biomechanical performance studies of cutting edge needles made of S45500 stainless steel alloy and SURGALLOYTM stainless steel demonstrated that needles made of SURGALLOYTM had superior performance characteristics over those made of S45500.