ANAndrew L. Niles

Andrew L. Niles

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Andrew L. Niles has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A Nondestructive, Real-Time Annexin V Apoptosis Assay

    by Andrew L. Niles, Kevin R. Kupcho

    This chapter describes a simple, nondestructive, annexin V apoptosis detection method that can be employed in real time over a 48-h test exposure. The real-time functionality allows for temporal resolution of apoptotic and cell death responses during the test exposure and obviates the need for onerous sample preparation and time course protocols associated with other annexin V methods. Further, this technique is eminently accessible to a wide range of laboratories because it does not require flow cytometry or other cytometric methods. It was developed for use with a variety of microplate well densities and with standard multimodal plate readers. The central feature of this assay is that it continuously reports the residency status of phosphatidylserine (PS) on the exofacial surface of a cell as it is translocated from the inner membrane leaflet during the apoptotic process. This homogenous, no-wash assay is made possible by two optimized and distinct annexin V fusion proteins which contain complementing NanoBiT™ luciferase enzyme subunits, a time-released luciferase substrate, and a fluorescent membrane integrity reagent. During an apoptotic event, the luminescent signal arising from an assay well is proportional to the number of cells with PS exposure, and fluorescence intensity correlates with the degree of cell death (secondary necrosis). Conversely, untreated cells contribute negligible luminescent or fluorescent signals throughout the time course. The data collected from these assay measures provide for both standard potency determinations and kinetic characterization of dose- and agent-dependent apoptotic responses, from early through late phases. Key words Apoptosis Phosphatidylserine Annexin V Bioluminescent Real time Homogenous No-wash Add-mix-measure Multiplexed NanoBiT™ Necrosis


  • A Real-Time, Bioluminescent Apoptosis Assay

    by Kevin R. Kupcho, Andrew L. Niles

    This chapter describes a real-time, bioluminescent apoptosis assay technique, which circumvents the well-documented “timing condundrum” encountered when employing traditional apoptosis detection chemistries after exposures with inducers of unknown potential. The assay continuously reports the translocation of phosphatidylserine (PS) from the inner membrane leaflet of a cell to the exofacial surface during apoptosis. This homogenous, no-wash, plate-based assay is made possible by two different annexin V fusion proteins, which contain complementing NanoBiT™ luciferase enzyme subunits, a time-released luciferase substrate, and a fluorescent membrane integrity reagent. During apoptosis, luminescence signal is proportional to PS exposure and fluorescence intensity correlated with the degree of secondary necrosis. Altogether, the measures provide exquisite kinetic resolution of dose- and agent-dependent apoptotic responses, from early through late phases. At exposure termination, other compatible reagents can be applied to measure additional orthogonal correlates of cell health.


  • Open Access

    A real-time, bioluminescent annexin V assay for the assessment of apoptosis

    by Kevin Kupcho, John Shultz, Robin Hurst, Jim Hartnett, Wenhui Zhou, Thomas Machleidt, Jamison Grailer, Tracy Worzella, Terry Riss, Dan Lazar, et al.

    Apoptosis is an important and necessary cell death program which promotes homeostasis and organismal survival. When dysregulated, however, it can lead to a myriad of pathologies from neurodegenerative diseases to cancer. Apoptosis is therefore the subject of intense study aimed at dissecting its pathways and molecular mechanisms. Although many assay methods exist for confirming whether an apoptotic response has occurred in vitro, most methods are destructive and involve laborious operator effort or specialized instrumentation. Here we describe a real-time, no-wash, microplate method which utilizes recombinant annexin V fusion proteins containing evolved binary subunits of NanoBiT™ luciferase. The fusion proteins, a time-released enzymatic substrate, a necrosis detection dye and exogenous calcium ions are delivered via an optimized and physiologically inert reagent directly to cells in culture at the time of treatment or dosing. Luminescent signals proportional to phosphatidylserine (PS) exposure and fluorescent signals generated as a result of loss of membrane integrity are then collected using a standard multimode plate reader at scheduled intervals over the exposure. The resulting luminescent and fluorescent data are then used to define the kinetics and magnitude of an apoptotic response. This study details our efforts to develop, characterize, and demonstrate the features of the assay by providing relevant examples from diverse cell models for programmed cell death.


  • “Multiplexed Viability, Cytotoxicity, and Caspase Activity Assays”

    by Andrew L. Niles, Terry L. Riss

    Multiplexed assay chemistries provide for multiple measurements of cellular parameters within a single assay well. This experimental practice is not only more cost efficient, but also provides more information about a compound or treatment. The ability to combine the activity profiles within the same sample provides a level of normalization not possible with parallel assays. Furthermore, multiplexing caspase activity assays with viability and/or cytotoxicity assays can support conclusions regarding cytotoxic mechanism and provide normalization, which may help correct for differences in cell number.


  • Detection of Lysine Deacetylase Activities

    by Nathan J. Evans, Thomas A. Kirkland, Chad Zimprich, Andrew L. Niles

  • Open Access

    In Vitro Viability and Cytotoxicity Testing and Same-Well Multi-Parametric Combinations for High Throughput Screening

    by Andrew L. Niles, Richard A. Moravec, Terry L. Riss

    In Vitro Viability and Cytotoxicity Testing and Same-Well Multi-Parametric Combinations for High Throughput Screening


  • Update onin vitrocytotoxicity assays for drug development

    by Andrew L Niles, Richard A Moravec, Terry L Riss

    (2008). Update on in vitro cytotoxicity assays for drug development. Expert Opinion on Drug Discovery: Vol. 3, No. 6, pp. 655-669. doi: 10.1517/17460441.3.6.655


  • A homogeneous assay to measure live and dead cells in the same sample by detecting different protease markers

    by Andrew L. Niles, Richard A. Moravec, P. Eric Hesselberth, Michael A. Scurria, William J. Daily, Terry L. Riss