Toshiyo Tamura
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Toshiyo Tamura has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
- Masaki Sekine
Osaka Electro-Communication University, Faculty of Biomedical Engineering /18-8, Hatsu-Cho, Neyagawa, Osaka 572-8530, Japan
4 shared publications Toshiro Fujimoto
3 shared publicationsA. Kohdabashi
2 shared publicationsKen-Ichi Kameyama
2 shared publicationsM. Mitsuyama
Daigo Hospital, Miyazaki Japan
2 shared publicationsM. Sekine
Member, IEEE, Department of Biomedical Engineering, School of Engineering, Chiba University, Chiba 263-8522 JAPAN
2 shared publications
Latest Publications
- 1 May 2012
- Vol. 55 (3) , 259-60
Current activities of the Japan society of medical and biological engineering.
- 1 May 2012
- Vol. 55 (3) , 259-60
Current activities of the Japan society of medical and biological engineering.
- 1 January 2011
- Published by The Society of Life Support Technology in Journal of Life Support Engineering
- Vol. 23 (3) , 124-129
Position Dependency in Photoplethysmographic sensor -Comparison of adjoining PPG signals in Light Sources and Measurement Sites-
- 1 January 2011
- Published by The Society of Life Support Technology in Journal of Life Support Engineering
- Vol. 23 (3) , 124-129
Position Dependency in Photoplethysmographic sensor -Comparison of adjoining PPG signals in Light Sources and Measurement Sites-
- 13 October 2010
- Published by Springer Nature in Journal of Medical Systems
- Vol. 36 (3) , 1425-1439
Application of Bayesian Classifier for the Diagnosis of Dental Pain
Toothache is the most common symptom encountered in dental practice. It is subjective and hence, there is a possibility of under or over diagnosis of oral pathologies where patients present with only toothache. Addressing the issue, the paper proposes a methodology to develop a Bayesian classifier for diagnosing some common dental diseases (D = 10) using a set of 14 pain parameters (P = 14). A questionnaire is developed using these variables and filled up by ten dentists (n = 10) with various levels of expertise. Each questionnaire is consisted of 40 real-world cases. Total 14*10*10 combinations of data are hence collected. The reliability of the data (P and D sets) has been tested by measuring (Cronbach’s alpha). One-way ANOVA has been used to note the intra and intergroup mean differences. Multiple linear regressions are used for extracting the significant predictors among P and D sets as well as finding the goodness of the model fit. A naïve Bayesian classifier (NBC) is then designed initially that predicts either presence/absence of diseases given a set of pain parameters. The most informative and highest quality datasheet is used for training of NBC and the remaining sheets are used for testing the performance of the classifier. Hill climbing algorithm is used to design a Learned Bayes’ classifier (LBC), which learns the conditional probability table (CPT) entries optimally. The developed LBC showed an average accuracy of 72%, which is clinically encouraging to the dentists.
- 13 October 2010
- Published by Springer Nature in Journal of Medical Systems
- Vol. 36 (3) , 1425-1439
Application of Bayesian Classifier for the Diagnosis of Dental Pain
Toothache is the most common symptom encountered in dental practice. It is subjective and hence, there is a possibility of under or over diagnosis of oral pathologies where patients present with only toothache. Addressing the issue, the paper proposes a methodology to develop a Bayesian classifier for diagnosing some common dental diseases (D = 10) using a set of 14 pain parameters (P = 14). A questionnaire is developed using these variables and filled up by ten dentists (n = 10) with various levels of expertise. Each questionnaire is consisted of 40 real-world cases. Total 14*10*10 combinations of data are hence collected. The reliability of the data (P and D sets) has been tested by measuring (Cronbach’s alpha). One-way ANOVA has been used to note the intra and intergroup mean differences. Multiple linear regressions are used for extracting the significant predictors among P and D sets as well as finding the goodness of the model fit. A naïve Bayesian classifier (NBC) is then designed initially that predicts either presence/absence of diseases given a set of pain parameters. The most informative and highest quality datasheet is used for training of NBC and the remaining sheets are used for testing the performance of the classifier. Hill climbing algorithm is used to design a Learned Bayes’ classifier (LBC), which learns the conditional probability table (CPT) entries optimally. The developed LBC showed an average accuracy of 72%, which is clinically encouraging to the dentists.
- 26 May 2010
- Published by IGI Global Scientific Publishing
- p. 282-294
Designing Pervasive Healthcare Applications in the Home
The authors propose a new home health care system for the acquisition and transmission of data from ordinary home health care appliances, such as blood pressure monitors and weight balances. In this chapter, they briefly explain a standard protocol for data collection and a simple interface to accommodate different monitoring systems that make use of different data protocols. The system provides for one-way data transmission, thus saving power and extending to CCITT. Their standardized protocol was verified during a 1-year field test involving 20 households in Japan. Data transmission errors between home health care devices and the home gateway were 4.21/day with their newly developed standard protocol. Over a 1-year period, they collected and analyzed data from 241,000 separate sources associated with both healthy, home-based patients and chronically ill, clinic-based patients, the latter with physician intervention. They evaluated some possible applications for collecting daily health care data and introduce some of their findings, relating primarily to body weight and blood pressure monitoring for elderly subjects in their own homes.
- 26 May 2010
- Published by IGI Global Scientific Publishing
- p. 282-294
Designing Pervasive Healthcare Applications in the Home
The authors propose a new home health care system for the acquisition and transmission of data from ordinary home health care appliances, such as blood pressure monitors and weight balances. In this chapter, they briefly explain a standard protocol for data collection and a simple interface to accommodate different monitoring systems that make use of different data protocols. The system provides for one-way data transmission, thus saving power and extending to CCITT. Their standardized protocol was verified during a 1-year field test involving 20 households in Japan. Data transmission errors between home health care devices and the home gateway were 4.21/day with their newly developed standard protocol. Over a 1-year period, they collected and analyzed data from 241,000 separate sources associated with both healthy, home-based patients and chronically ill, clinic-based patients, the latter with physician intervention. They evaluated some possible applications for collecting daily health care data and introduce some of their findings, relating primarily to body weight and blood pressure monitoring for elderly subjects in their own homes.
- Open Access
- 9 October 2008
- Published by Bentham Science Publishers Ltd. in The Open Medical Informatics Journal
- Vol. 1 (1) , 1-7
E-Healthcare at an Experimental Welfare Techno House in Japan
An automated monitoring system for home health care has been designed for an experimental house in Japan called the Welfare Techno House (WTH). Automated electrocardiogram (ECG) measurements can be taken while in bed, in the bathtub, and on the toilet, without the subject's awareness, and without using body surface electrodes. In order to evaluate this automated health monitoring system, overnight measurements were performed to monitor health status during the daily lives of both young and elderly subjects.
- 9 October 2008
- Published by Bentham Science Publishers Ltd. in The Open Medical Informatics Journal
- Vol. 1 (1) , 1-7
Open AccessE-Healthcare at an Experimental Welfare Techno House in Japan
An automated monitoring system for home health care has been designed for an experimental house in Japan called the Welfare Techno House (WTH). Automated electrocardiogram (ECG) measurements can be taken while in bed, in the bathtub, and on the toilet, without the subject's awareness, and without using body surface electrodes. In order to evaluate this automated health monitoring system, overnight measurements were performed to monitor health status during the daily lives of both young and elderly subjects.
- 1 January 2008
- Published by The Society of Life Support Technology in Journal of Life Support Engineering
- Vol. 20 (Supplement) , 128
Development of new step count algorithm without positioning of the step counter
- 1 January 2008
- Published by The Society of Life Support Technology in Journal of Life Support Engineering
- Vol. 20 (Supplement) , 128
Development of new step count algorithm without positioning of the step counter
- 1 January 2008
- Published by The Society of Life Support Technology in Journal of Life Support Engineering
- Vol. 20 (Supplement) , 150
Neuropsychological examination with computer based testing(CBT)to elderly with dementia
- 1 January 2008
- Published by The Society of Life Support Technology in Journal of Life Support Engineering
- Vol. 20 (Supplement) , 150
Neuropsychological examination with computer based testing(CBT)to elderly with dementia
- 1 August 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 258 (1094687X) , 2964-2967
A New Non-invasive Method for Measuring Blood Glucose Using Instantaneous Differential Near Infrared Spectrophotometry
We describe further development of a novel method for non-invasive measurement of blood glucose concentration (BGL), named Pulse Glucometry, based on differential near infrared spectrophotometry. Sequential temporal differences of infrared transmittance spectra from the radiation intensity (Ilambda) emerging from a fingertip containing an arterial pulse component (DeltaIlambda) are analysed. To perform the measurements we developed a new high-speed spectrophotometer, covering the wavelength range from 900 to 1700 nm, scanning at a maximum spectral rate of 1800 spectra/s, with a minimum exposure time of 20 mus. Spectra related only to the pulsatile blood component are derived, thus minimising influences of basal components such as resting blood volume, skin, muscle and bone. We have now improved the performance of the spectrophotometer and in the present paper we describe new in vivo measurements carried out in 23 healthy volunteers undergoing glucose tolerance tests. Blood samples were collected from the cephalic vein simultaneously with radiation intensity measurements in the fingertip every 10 min before and after oral administration of glucose solution for 120 min. BGL values were then predicted using a PLS calibration model and compared with blood values determined by colorimetric assay. The precision and accuracy of the non-invasive determinations are encouraging.
- 1 August 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 258 (1094687X) , 2964-2967
A New Non-invasive Method for Measuring Blood Glucose Using Instantaneous Differential Near Infrared Spectrophotometry
We describe further development of a novel method for non-invasive measurement of blood glucose concentration (BGL), named Pulse Glucometry, based on differential near infrared spectrophotometry. Sequential temporal differences of infrared transmittance spectra from the radiation intensity (Ilambda) emerging from a fingertip containing an arterial pulse component (DeltaIlambda) are analysed. To perform the measurements we developed a new high-speed spectrophotometer, covering the wavelength range from 900 to 1700 nm, scanning at a maximum spectral rate of 1800 spectra/s, with a minimum exposure time of 20 mus. Spectra related only to the pulsatile blood component are derived, thus minimising influences of basal components such as resting blood volume, skin, muscle and bone. We have now improved the performance of the spectrophotometer and in the present paper we describe new in vivo measurements carried out in 23 healthy volunteers undergoing glucose tolerance tests. Blood samples were collected from the cephalic vein simultaneously with radiation intensity measurements in the fingertip every 10 min before and after oral administration of glucose solution for 120 min. BGL values were then predicted using a PLS calibration model and compared with blood values determined by colorimetric assay. The precision and accuracy of the non-invasive determinations are encouraging.
- 1 January 2007
- Published by The Society of Life Support Technology in Journal of Life Support Engineering
- Vol. 19 (Supplement) , 183
Performance evaluation of green photoplethysmography
- 1 January 2007
- Published by The Society of Life Support Technology in Journal of Life Support Engineering
- Vol. 19 (Supplement) , 183
Performance evaluation of green photoplethysmography
- 22 September 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 212-220
Motion analysis measurement
- 22 September 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 212-220
Motion analysis measurement